-- CISCO-ATM-DUAL-PHY-MIB.my: Cisco atm dual phy MIB file
|
|
--
|
|
-- July 1996, Steve Garcia and David Battle
|
|
--
|
|
-- Copyright (c) 1996-1998 by cisco Systems, Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
|
|
|
|
|
|
|
|
CISCO-ATM-DUAL-PHY-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
NOTIFICATION-TYPE,
|
|
Counter32
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
TruthValue
|
|
FROM SNMPv2-TC
|
|
InterfaceIndexOrZero
|
|
FROM CISCO-TC
|
|
ifIndex,
|
|
InterfaceIndex
|
|
FROM IF-MIB
|
|
ciscoMgmt
|
|
FROM CISCO-SMI;
|
|
|
|
|
|
ciscoAtmDualPhyMIB MODULE-IDENTITY
|
|
LAST-UPDATED "9608300000Z"
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
CONTACT-INFO
|
|
" Cisco Systems
|
|
Customer Service
|
|
|
|
Postal: 170 W. Tasman Drive
|
|
San Jose, CA 95134-1706
|
|
USA
|
|
|
|
Tel: +1 800 553-NETS
|
|
|
|
E-mail: cs-atm@cisco.com"
|
|
DESCRIPTION
|
|
"Initial version of this MIB module.
|
|
|
|
|
|
Phy definition
|
|
|
|
Throughout this document phy is used as an abbreviation
|
|
for Physical Interface. In particular it refers to a
|
|
physical ATM jack on a Catalyst 5000 ATM card. This card
|
|
can be fitted with either one or two physical jacks, only
|
|
one of which may be active at any given moment. The second
|
|
phy serves as a redundant connector to the ATM backbone.
|
|
Note, however, that for logistical reasons, each phy has
|
|
a separate ifIndex.
|
|
|
|
|
|
Support of the phy by ifTable
|
|
|
|
The dual phy entity on the c5K ATM line card is managed
|
|
using the ifTable. Specific interpretations of ifTable
|
|
for the dual phy entity are as follows.
|
|
|
|
Object Use for dual phy entity
|
|
====== =======================
|
|
|
|
ifIndex Each phy entity is represented by an ifEntry.
|
|
|
|
ifDescr Description of the phy entity.
|
|
|
|
ifType The value for the phy entity is other(1).
|
|
|
|
ifSpeed See [1].
|
|
|
|
ifPhysAddress An octet string of zero length, per [1].
|
|
|
|
ifAdminStatus See [1].
|
|
|
|
ifOperStatus See [1]. In addition, note that a phy can
|
|
be in the up state but still not be the
|
|
active phy. However, the active phy will
|
|
always be up.
|
|
|
|
ifLastChange See [1].
|
|
|
|
ifName See [1].
|
|
|
|
ifLinkUpDownTrapEnable disabled(2).
|
|
|
|
ifHighSpeed See [1].
|
|
|
|
ifConnectorPresent true(1).
|
|
|
|
|
|
References
|
|
|
|
[1] McCloghrie, K. and F. Kastenholz, Evolution of the
|
|
Interfaces Group of MIB-II, RFC 1573, Hughes LAN Systems,
|
|
FTP Software, January 1994."
|
|
::= { ciscoMgmt 60 }
|
|
|
|
ciscoAtmDualPhyMIBObjects OBJECT IDENTIFIER ::= { ciscoAtmDualPhyMIB 1 }
|
|
|
|
cadpStatistics OBJECT IDENTIFIER ::= { ciscoAtmDualPhyMIBObjects 1 }
|
|
|
|
cadpStatTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CadpStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of status information about ATM phy."
|
|
::= { cadpStatistics 1 }
|
|
|
|
cadpStatEntry OBJECT-TYPE
|
|
SYNTAX CadpStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An Atm Phy table entry, containing information about
|
|
a phy on this ATM module."
|
|
INDEX { ifIndex }
|
|
::= { cadpStatTable 1 }
|
|
|
|
CadpStatEntry ::=
|
|
SEQUENCE {
|
|
-- index is ifIndex
|
|
-- status items
|
|
cadpStatLossOfSignal TruthValue,
|
|
cadpStatFarEndReceiveFailure TruthValue,
|
|
cadpStatActive TruthValue,
|
|
cadpStatSectionBIP8Errors Counter32,
|
|
cadpStatLineBIP824Errors Counter32,
|
|
cadpStatLineFEBErrors Counter32,
|
|
cadpStatPathBIP8Errors Counter32,
|
|
cadpStatPathFEBErrors Counter32,
|
|
cadpStatCorrectableHCSErrors Counter32,
|
|
cadpStatUncorrectableHCSErrors Counter32
|
|
}
|
|
|
|
cadpStatLossOfSignal OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set to true if the phy is currently experiencing a
|
|
loss of signal (LOS) from its connected port. Set to false
|
|
if the phy is not experiencing a loss of signal."
|
|
::= { cadpStatEntry 1 }
|
|
|
|
cadpStatFarEndReceiveFailure OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set to true if the phy is currently experiencing a far
|
|
end receive failure (FERF) with its connected port. Set to
|
|
false if the phy is not experiencing a far end receive
|
|
failure."
|
|
::= { cadpStatEntry 2 }
|
|
|
|
cadpStatActive OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set to true when this phy is currently the active phy.
|
|
Set to false when this phy is not the currently active phy."
|
|
::= { cadpStatEntry 5 }
|
|
|
|
cadpStatSectionBIP8Errors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bit Interleaved Parity 8 is an error checking code
|
|
applied for quick isolation of faults. Each bit in the
|
|
B octets is set to 1 or 0 as necessary to obtain even
|
|
parity over the previous frame. The calculated BIP-8
|
|
code for frame N is compared with the BIP-8 code extracted
|
|
from the B1 byte of frame N+1. Differences indicate that
|
|
a section level bit error has occurred.
|
|
|
|
Count of Section BIP-8 (Bit Interleaved Parity) errors
|
|
that have been detected on this phy. "
|
|
::= { cadpStatEntry 6 }
|
|
|
|
cadpStatLineBIP824Errors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bit Interleaved Parity 8/24 is an error checking code
|
|
based on even parity. The calculated BIP code for frame N
|
|
is compared with the BIP-8/24 code extracted from the B2
|
|
byte(s) of frame N+1. Any differences indicate that a
|
|
line layer bit error has occurred.
|
|
|
|
Count of line bit interleaved partiy (BIP-8/24) errors on
|
|
this phy. "
|
|
::= { cadpStatEntry 7 }
|
|
|
|
cadpStatLineFEBErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bits (binary 000 to 1000) in the previous
|
|
BIP-8 that didn't match the even parity check are inserted
|
|
by the transmitter. The receiver checks for this in the
|
|
M0/M1 byte of the frame. A non-zero value (legal range
|
|
is binary 0000 - 1000) indicates a line layer error in
|
|
the remote end. Any other value is treated as no error.
|
|
|
|
Count of Line Far End Bit Errors (FEBE) on this phy."
|
|
::= { cadpStatEntry 8 }
|
|
|
|
cadpStatPathBIP8Errors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bit Interleaved Parity 8 is an error checking code
|
|
applied for quick isolation of faults. Each bit in the
|
|
B octets is set to 1 or 0 as necessary to obtain even
|
|
parity over the previous frame.
|
|
|
|
The calculated BIP-8 code for frame N is compared with
|
|
the BIP-8 code extracted from the B3 byte of frame N+1.
|
|
Differences indicate that a Path level bit error has
|
|
occurred.
|
|
|
|
Count of Path BIP-8 (Bit Interleaved Parity) errors that
|
|
have been detected on this phy."
|
|
::= { cadpStatEntry 9 }
|
|
|
|
cadpStatPathFEBErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of B3 errors in the previous frame inserted
|
|
by the transmitter. The receiver checks for this in the
|
|
G1 byte of the frame. A non-zero value (legal range is
|
|
binary 0000 - 1000) indicates a line layer error in
|
|
the remote end. Any other value is treated as no error.
|
|
|
|
Count of Path Far End Bit Errors (FEBE) on this phy."
|
|
::= { cadpStatEntry 10 }
|
|
|
|
cadpStatCorrectableHCSErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Header Checksum (HCS) is a CRC-8 calculation over
|
|
the first 4 octets of the ATM cell header. The received
|
|
HCS is verified using the polynomial x^8 + x^2 + x + 1.
|
|
The coset polynomial x^6 + x^4 + x^2 + 1, is added
|
|
(modulo 2) to the received HCS octet before comparison
|
|
with the calculated result. Cells with single bit error
|
|
in the HCS byte are corrected. Cells with more than one
|
|
bit error in the HCS byte are uncorrectable.
|
|
|
|
Count of incoming cells on this phy with single bit error
|
|
in the Header Checksum (HCS) byte"
|
|
::= { cadpStatEntry 11 }
|
|
|
|
cadpStatUncorrectableHCSErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Header Checksum (HCS) is a CRC-8 calculation over
|
|
the first 4 octets of the ATM cell header. The received
|
|
HCS is verified using the polynomial x^8 + x^2 + x + 1.
|
|
The coset polynomial x^6 + x^4 + x^2 + 1, is added
|
|
(modulo 2) to the received HCS octet before comparison
|
|
with the calculated result. Cells with single bit error
|
|
in the HCS byte are corrected. Cells with more than one
|
|
bit error in the HCS byte are uncorrectable.
|
|
|
|
Count of uncorrectable Header Checksum (HCS) errors on
|
|
this phy."
|
|
::= { cadpStatEntry 12 }
|
|
|
|
|
|
-- end of cadpStatTable
|
|
|
|
cadpStatOperActivePhy OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the ifIndex of the phy which is currently the
|
|
active phy. A value of 0 indicates that no phy is
|
|
currently active."
|
|
::= { cadpStatistics 2 }
|
|
|
|
cadpStatAdminActivePhy OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Returns the ifIndex of the phy which is the preferred
|
|
active phy. A value of 0 indicates that no phy is
|
|
currently active.
|
|
|
|
Setting this object to a value different from its current
|
|
value causes the ATM module to make the indicated phy active,
|
|
and the active phy inactive.
|
|
|
|
Setting this object to its current value has no effect.
|
|
|
|
After performing the phy change, the agent will update
|
|
all phy information (including cadpStatOperActivePhy)
|
|
and send a ciscoAtmDualPhyChange trap."
|
|
::= { cadpStatistics 3 }
|
|
|
|
|
|
ciscoAtmDualPhyMIBTrapPrefix OBJECT IDENTIFIER ::= { ciscoAtmDualPhyMIB 2 }
|
|
ciscoAtmDualPhyMIBTraps OBJECT IDENTIFIER ::= { ciscoAtmDualPhyMIBTrapPrefix 0 }
|
|
|
|
ciscoAtmDualPhyChange NOTIFICATION-TYPE
|
|
OBJECTS { cadpStatOperActivePhy -- the new active phy, or 0
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ciscoAtmDualPhyChange trap is sent when the active phy
|
|
changes either because of a failure or because of user
|
|
intervention (setting cadpStatAdminActivePhy, for example)."
|
|
::= { ciscoAtmDualPhyMIBTraps 1 }
|
|
|
|
|
|
-- conformance information
|
|
|
|
ciscoAtmDualPhyMIBConformance OBJECT IDENTIFIER ::= { ciscoAtmDualPhyMIB 3 }
|
|
ciscoAtmDualPhyMIBCompliances OBJECT IDENTIFIER ::= { ciscoAtmDualPhyMIBConformance 1 }
|
|
ciscoAtmDualPhyMIBGroups OBJECT IDENTIFIER ::= { ciscoAtmDualPhyMIBConformance 2 }
|
|
|
|
|
|
-- compliance statements
|
|
|
|
ciscoAtmDualPhyMIBCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
the Cisco Atm Dual Phy MIB. This MIB is mandatory for
|
|
all Cisco ATM products with multiple phy."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ciscoAtmDualPhyMIBGroup }
|
|
::= { ciscoAtmDualPhyMIBCompliances 1 }
|
|
|
|
-- units of conformance
|
|
|
|
ciscoAtmDualPhyMIBGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cadpStatLossOfSignal,
|
|
cadpStatFarEndReceiveFailure,
|
|
cadpStatActive,
|
|
cadpStatSectionBIP8Errors,
|
|
cadpStatLineBIP824Errors,
|
|
cadpStatLineFEBErrors,
|
|
cadpStatPathBIP8Errors,
|
|
cadpStatPathFEBErrors,
|
|
cadpStatCorrectableHCSErrors,
|
|
cadpStatUncorrectableHCSErrors,
|
|
cadpStatAdminActivePhy,
|
|
cadpStatOperActivePhy
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing ATM dual phy monitoring."
|
|
::= { ciscoAtmDualPhyMIBGroups 1 }
|
|
|
|
END
|