-- File: xylo-ports.mib
-- Bay Networks Remote Annex Private Enterprise MIB
--
-- Copyright 1991, 1993, 1994, 1995, 1996, 1997 Bay Networks, Inc.
-- ALL RIGHTS RESERVED.
--
-- ALL RIGHTS RESERVED. Licensed Material - Property of Bay Networks, Inc.
-- This software is made available solely pursuant to the terms of a
-- software license agreement which governs its use.
-- Unauthorized duplication, distribution or sale are strictly prohibited.
--
-- This information is subject to change without notice, and should
-- not be construed as a commitment by Bay Networks, Inc. Bay Networks, Inc.,
-- assumes no responsibility for any errors that may appear in this
-- document.
--
XYLO-PORTS-MIB DEFINITIONS ::= BEGIN
IMPORTS
TimeTicks, IpAddress, Counter
FROM RFC1155-SMI
DisplayString
FROM RFC1213-MIB
OBJECT-TYPE
FROM RFC-1212
ports, parallelport, anxsyncports, anxModem
FROM XYLO-MIB-SMI;
-- xylogics OBJECT IDENTIFIER ::= { enterprises 15 }
-- annex OBJECT IDENTIFIER ::= { xylogics 2 }
-- ports OBJECT IDENTIFIER ::= { annex 3 }
-- parallelport OBJECT IDENTIFIER ::= { annex 4 }
-- anxsyncports OBJECT IDENTIFIER ::= { annex 9 }
-- anxModem OBJECT IDENTIFIER ::= { annex 100 }
-- anxinterface OBJECT IDENTIFIER ::= { annex 13 }
-- the ports group
totalPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of serial ports on this Annex."
::= { ports 1 }
totalInChars OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total number of characters received on all
serial ports."
::= { ports 2 }
totalOutChars OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total number of characters transmitted on
all serial ports."
::= { ports 3 }
totalParityErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total number of parity errors detected
on all serial ports."
::= { ports 4 }
totalOverrunErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total number of overruns detected on all
serial ports."
::= { ports 5 }
totalFramingErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total number of framing errors detected
on all serial ports."
::= { ports 6 }
portTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Table of port entries."
::= { ports 7 }
portEntry OBJECT-TYPE
SYNTAX PortEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The port's configuration parameters."
INDEX { anxpPortIndex }
::= { portTable 1 }
PortEntry ::= SEQUENCE {
anxpPortIndex INTEGER,
anxpMode INTEGER,
anxpCtrlLines INTEGER,
anxpBidirModem INTEGER,
anxpAllowBcast INTEGER,
anxpBcastDirection INTEGER,
anxpInputStartChar DisplayString,
anxpInputStopChar DisplayString,
anxpOutputStartChar DisplayString,
anxpOutputStopChar DisplayString,
anxpIxanyFlowCtl INTEGER,
anxpLongBreak INTEGER,
anxpShortBreak INTEGER,
anxpForwardTimer INTEGER,
anxpForwardCount INTEGER,
anxpImask7Bits INTEGER,
anxpAttnChar DisplayString,
anxpInputBufSize INTEGER,
anxpInputIsActivity INTEGER,
anxpOutputIsActivity INTEGER,
anxpInactivityTimer INTEGER,
anxpResetIdleTimer INTEGER,
anxpCliInactivity INTEGER,
anxpCliSecurity INTEGER,
anxpConnectSecurity INTEGER,
anxpPortServerSecurity INTEGER,
anxpPortPassword DisplayString,
anxpUserName DisplayString,
anxpDedicatedAddr IpAddress,
anxpDedicatedPort DisplayString,
anxpPrompt DisplayString,
anxpTermVar DisplayString,
anxpNewLineTerm INTEGER,
anxpEcho INTEGER,
anxpMapToLower INTEGER,
anxpMapToUpper INTEGER,
anxpHardwareTabs INTEGER,
anxpCharErase INTEGER,
anxpLineErase INTEGER,
anxpEraseChar DisplayString,
anxpEraseWord DisplayString,
anxpEraseLine DisplayString,
anxpRedisplayLine DisplayString,
anxpToggleOutput DisplayString,
anxpTelnetEscape DisplayString,
anxpNeedDsr INTEGER,
anxpTelnetCRLF INTEGER,
anxpLatbEnable INTEGER,
anxpSlipSecure INTEGER,
anxpNetLocalAddr IpAddress,
anxpNetRemoteAddr IpAddress,
anxpSlipSubnetMask IpAddress,
anxpSlipLoadDumpHost IpAddress,
anxpNetMetric INTEGER,
anxpSlipAllowDump INTEGER,
anxpDoCompression INTEGER,
anxpAllowCompression INTEGER,
anxpSlipMtuSize INTEGER,
anxpSlipNoIcmp INTEGER,
anxpSlipTos INTEGER,
anxpPppMru INTEGER,
anxpPppAcm DisplayString,
anxpPppSecurityProto INTEGER,
anxpPppUserRemote DisplayString,
anxpPppPasswdRemote DisplayString,
anxpLatAuthGroupVal DisplayString,
anxpPppDialupAddr INTEGER,
anxpBanner INTEGER,
anxpPsHistory INTEGER,
anxpLocation DisplayString,
anxpType INTEGER,
anxpCliImask7 INTEGER,
anxpModemVar DisplayString,
anxpPppNcp INTEGER,
anxpPhoneNumber DisplayString,
anxpNetInactivity INTEGER,
anxpAtGuest INTEGER,
anxpAtNodeid DisplayString,
anxpAtSecurity INTEGER,
anxpArapV42bis INTEGER,
anxpTn3270PrinterHost IpAddress,
anxpTn3270PrinterName DisplayString,
anxpTcpKeepAlive INTEGER,
anxpDtrSignal INTEGER,
anxpRtsSignal INTEGER,
anxpCliInterface INTEGER,
anxpAutobaud INTEGER,
anxpDefSessMode INTEGER,
anxpIpxSecurity INTEGER,
anxpIpsoClass INTEGER,
anxpVciLoginPortPasswd INTEGER,
anxpVciLoginTimeout INTEGER,
anxpDedicatedArgs DisplayString,
anxpNetInactivityUnits INTEGER,
anxpResolveProtocol INTEGER,
anxpForwardKey DisplayString,
anxpBackwardKey DisplayString,
anxpPppIpxNetwork DisplayString,
anxpPppIpxNode DisplayString,
anxpLatAuthMap OCTET STRING,
anxpMultiSession INTEGER,
anxpAutoTimeout INTEGER,
anxpAutoPPPSecurity INTEGER
}
anxpPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"A unique number from 1 to totalPorts that
identifies each serial port."
::= { portEntry 1 }
anxpMode OBJECT-TYPE
SYNTAX INTEGER {
cli(1),
slave(2),
adaptive(3),
unused(4),
slip(5),
dedicated(6),
ppp(7),
arap(8),
invalid(9),
auto-detect(10),
auto-adapt(11),
ndp(12),
ipx(13),
call(14),
connect(15),
rlogin(16),
telnet(17),
tn3270(18)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter defines the mode for access to
the serial line port. The default is cli.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'mode'."
::= { portEntry 2 }
anxpCtrlLines OBJECT-TYPE
SYNTAX INTEGER {
none(1),
flowcontrol(2),
modemcontrol(3),
both(4)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The type of hardware control used on the port:
none, modem control (dcd/dtr), flow control (cts/rts),
or both.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'control_lines'."
::= { portEntry 3 }
anxpBidirModem OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter controls whether the port is
configured for adaptive use with a bidirectional
modem.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'bidirectional_modem'."
::= { portEntry 4 }
anxpAllowBcast OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Controls whether the serial port can receive
administrative broadcast messages.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'allow_broadcast'."
::= { portEntry 5 }
anxpBcastDirection OBJECT-TYPE
SYNTAX INTEGER {
port(1),
network(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Defines the direction that an administrative
broadcast message is sent. This parameter is
valid only when the port is defined as a slave
port by the anxpMode parameter.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'broadcast_direction'."
::= { portEntry 6 }
anxpInputStartChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The control character sequence that restarts
input if the charPortInFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'input_start_char'."
::= { portEntry 7 }
anxpInputStopChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The control character sequence that stops
input if the charPortInFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'input_stop_char'."
::= { portEntry 8 }
anxpOutputStartChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The control character sequence that restarts
output if the charPortOutFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'output_start_char'."
::= { portEntry 9 }
anxpOutputStopChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The control character sequence that stops
output if the charPortOutFlowType parameter
(in the char MIB) is set to xonXoff.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'output_stop_char'."
::= { portEntry 10 }
anxpIxanyFlowCtl OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter specifies whether any input
character will be treated as a start (xon)
character when output has been suspended by
a stop (xoff) character.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'ixany_flow_control'."
::= { portEntry 11 }
anxpLongBreak OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter controls whether the Annex
returns the user to the CLI prompt after
receiving a break greater than two seconds.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'long_break'."
::= { portEntry 12 }
anxpShortBreak OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter controls whether the Annex
returns the user to the CLI prompt after
receiving a break shorter than two seconds.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'short_break'."
::= { portEntry 13 }
anxpForwardTimer OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter defines the inter-character
timer that sets the amount of time, in tens of
milliseconds, that will elapse before
forwarding the received data. The value of
5 turns off the timer. Setting this object
to 0 causes the default value of 5 to be used.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'forwarding_timer'."
::= { portEntry 14 }
anxpForwardCount OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Specifies the number of received characters
buffered for the port by the Annex before
forwarding the characters to the host or
network.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'forwarding_count'."
::= { portEntry 15 }
anxpImask7Bits OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"When enabled, instructs the Annex to ignore
the eighth bit of all received characters
on the port.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'imask_7bits'."
::= { portEntry 16 }
anxpAttnChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Defines a control character sequence as an
attention character to return the user to
the CLI prompt. The Annex-II only allows
a single control character (eg. ^A), while
the Annex3 and MicroAnnex allow a string
of control characters to be defined
(eg. ^A^B^Z).
This MIB object corresponds to the NA/admin
asynchronous port parameter 'attn_string'."
::= { portEntry 17 }
anxpInputBufSize OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The number of 256-byte blocks allocated to
receive input characters from this port.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'input_buffer_size'."
::= { portEntry 18 }
anxpInputIsActivity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Controls whether received input characters
are considered as activity for the port.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'input_is_activity'."
::= { portEntry 19 }
anxpOutputIsActivity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Controls whether transmitted output characters
are considered as activity for the port.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'output_is_activity'."
::= { portEntry 20 }
anxpInactivityTimer OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The amount of time, in minutes, which a port
can remain inactive before the Annex terminates
all sessions and resets the port. A value of
0 disables the timer.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'inactivity_timer'."
::= { portEntry 21 }
anxpResetIdleTimer OBJECT-TYPE
SYNTAX INTEGER {
input(1),
output(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Defines whether input or output resets the
idle timer for the port.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'reset_idle_time_on'."
::= { portEntry 22 }
anxpCliInactivity OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The amount of time, in minutes, that the Annex
waits before hanging up the serial port after
it becomes idle. A value of 0 turns off the
timer. A value of 255 means immediate, which
causes the Annex to hang up the port immediately
after exiting from the last job.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'cli_inactivity'."
::= { portEntry 23 }
anxpCliSecurity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter controls whether security is
enabled for the port.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'cli_security'."
::= { portEntry 24 }
anxpConnectSecurity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter controls whether the host-based
security policy is enabled for access from the
port to the network.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'connect_security'."
::= { portEntry 25 }
anxpPortServerSecurity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter controls whether the host-based
security policy is enabled for access to the
port from the port server.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'port_server_security'."
::= { portEntry 26 }
anxpPortPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter defines a password for the
port for local password protection.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'port_password'."
::= { portEntry 27 }
anxpUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"A string defining the default user name for
the user of this serial port.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'user_name'."
::= { portEntry 28 }
anxpDedicatedAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS deprecated
DESCRIPTION
"When the anxpMode parameter is set to dedicated,
this parameter defines the Internet address
of the host to which this port can connect to.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'dedicated_address'.
See also anxpDedicatedPort below. These objects
are being phased out in favor of the object
anxpDedicatedArgs."
::= { portEntry 29 }
anxpDedicatedPort OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The application name or TCP port number to
which this port can connect when the anxpMode
parameter is set to dedicated. The allowed
application names are 'telnet', 'rlogin',
and 'call'. If a number is specified, the
number must range between 0 and 65535.
Certain numeric values are translated to the
above names as follows:
Set value Get value
0 telnet
23 telnet
513 rlogin
1027 call
This MIB object corresponds to the NA/admin
asynchronous port parameter 'dedicated_port'.
See also anxpDedicatedAddr above. These objects
are being phased out in favor of the object
anxpDedicatedArgs."
::= { portEntry 30 }
anxpPrompt OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter defines a port-specific prompt
string. The prompt string consists of displayable
characters and embedded formatting codes. Each
formatting code is stored in a single character
in nonvolatile memory. The maximum number of
characters stored for the prompt string
is 16. Since the formatting codes consist of
a '%' prepended to a single character, the maximum
length string that may be entered for this object
is 32 characters. Strings less than 32
characters in length will be rejected as bad values
if they cannot be stored into 16 characters in
nonvolatile memory after the formatting codes are
compressed into single characters.
The valid formatting codes are:
%a the string 'annex'
%c the string ': '
%d the date and time
%i the Annex's IP address
%j a newline character
%l port location, or 'port n'
%n the Annex's name
%p the port number
%r the string 'port'
%s a space
%t the time hh:mm:ss
%u the user name for port
%% the string '%'
This MIB object corresponds to the NA/admin
asynchronous port parameter 'prompt'."
::= { portEntry 31 }
anxpTermVar OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"A string defining the type of terminal attached
to the serial port.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'term_var'."
::= { portEntry 32 }
anxpNewLineTerm OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter controls whether a carriage
return is echoed as just a carriage return
(enabled), or whether the carriage return is
echoed as a carriage return and line feed.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'newline_terminal'."
::= { portEntry 33 }
anxpEcho OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter controls whether the Annex
echoes all characters as they are received
from the port.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'echo'."
::= { portEntry 34 }
anxpMapToLower OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"When enabled, the Annex translates all upper
case characters to lower case as they are
received from the port.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'map_to_lower'."
::= { portEntry 35 }
anxpMapToUpper OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"When enabled, the Annex translates all lower
case characters to upper case as they are
transmitted to the port.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'map_to_upper'."
::= { portEntry 36 }
anxpHardwareTabs OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"When enabled, this parameter allows the Annex
to expand ASCII tab characters.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'hardware_tabs'."
::= { portEntry 37 }
anxpCharErase OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter controls whether the Annex
echoes the character erase and word erase
characters for a video terminal (enabled)
or for a hard-copy terminal (disabled).
This MIB object corresponds to the NA/admin
asynchronous port parameter 'char_erase'."
::= { portEntry 38 }
anxpLineErase OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter controls whether the Annex
echoes the line erase character for a video
terminal (enabled) or for a hard-copy terminal
(disabled).
This MIB object corresponds to the NA/admin
asynchronous port parameter 'line_erase'."
::= { portEntry 39 }
anxpEraseChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Defines the character erase control character
sequence.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'erase_char'."
::= { portEntry 40 }
anxpEraseWord OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Defines the word erase control character
sequence.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'erase_word'."
::= { portEntry 41 }
anxpEraseLine OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Defines the line erase control character
sequence.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'erase_line'."
::= { portEntry 42 }
anxpRedisplayLine OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Defines the reprint line control character
sequence.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'redisplay_line'."
::= { portEntry 43 }
anxpToggleOutput OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Defines the flush control character used to
flush the output buffer.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'toggle_output'."
::= { portEntry 44 }
anxpTelnetEscape OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..2))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Defines the control character that returns the
user to the 'telnet:' prompt when running the
CLI telnet command.
This value of this object can be either a single
displayable character or two characters of the
form '^x', where '^x' is translated as 'Control-x'.
The value 'U' disables this feature on the
specified port.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'telnet_escape'."
::= { portEntry 45 }
anxpNeedDsr OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Specifies whether the DSR signal needs to be
asserted when connecting to a slave port.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'need_dsr'."
::= { portEntry 46 }
anxpTelnetCRLF OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Defines what characters are transmitted
out the port to the network when the
End-of-Line character is sensed. 'enabled'
means transmit Line-Feed and Carriage-Return.
'disabled' means transmit Carriage-Return
and NULL. The default is enabled.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'telnet_crlf'."
::= { portEntry 47 }
anxpLatbEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Controls interpretation of LAT Data-B packets
received from host.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'latb_enable'."
::= { portEntry 48 }
anxpSlipSecure OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"If anxEnableSecurity is not set, this
parameter selects slip session logging. If
anxEnableSecurity is set, this parameter
permits slip access only from secure ports.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'slip_ppp_security'."
::= { portEntry 49 }
anxpNetLocalAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Internet address for the Annex's side
of the point-to-point (SLIP or PPP) link.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'local_address'."
::= { portEntry 50 }
anxpNetRemoteAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Internet address for the host at the
remote end of the point-to-point (SLIP or PPP)
link.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'remote_address'."
::= { portEntry 51 }
anxpSlipSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The subnet mask for this SLIP interface.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'subnet_mask'."
::= { portEntry 52 }
anxpSlipLoadDumpHost OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Internet address of the host from which
the Annex receives a load or to which the
Annex sends a dump over the SLIP interface.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'slip_load_dump_host'."
::= { portEntry 53 }
anxpNetMetric OBJECT-TYPE
SYNTAX INTEGER (0..64)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter defines the hop count to
the remote end of the SLIP or PPP interface.
Setting this object to 0 defaults to a
value of 1.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'metric'."
::= { portEntry 54 }
anxpSlipAllowDump OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter defines whether the Annex is
allowed to dump across a SLIP link.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'slip_allow_dump'."
::= { portEntry 55 }
anxpDoCompression OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"When enabled, the Annex will attempt to negotiate
TCP/IP header compression on this serial link.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'do_compression'."
::= { portEntry 56 }
anxpAllowCompression OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"When enabled, the Annex will allow TCP/IP
header compression on this serial link only
if the other end of the serial link initiates
the compression.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'allow_compression'."
::= { portEntry 57 }
anxpSlipMtuSize OBJECT-TYPE
SYNTAX INTEGER {
large(1),
small(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Force the compressed SLIP interface to use
a Maximum Transmission Unit (MTU) of either
1024 bytes (large) or 256 bytes (small). The
default is large.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'slip_mtu_size'."
::= { portEntry 58 }
anxpSlipNoIcmp OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"When enabled, the Annex will discard any
ICMP packets directed to this SLIP link.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'slip_no_icmp'."
::= { portEntry 59 }
anxpSlipTos OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"When enabled, the Annex sends interactive
traffic over this SLIP link before any other
traffic.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'slip_tos'."
::= { portEntry 60 }
anxpPppMru OBJECT-TYPE
SYNTAX INTEGER (64..1500)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter defines the maximum receive
unit in bytes. The default value is 1500.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'ppp_mru'."
::= { portEntry 61 }
anxpPppAcm OBJECT-TYPE
SYNTAX DisplayString (SIZE (8..10))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter specifies which of the first
32 bytes (0x00, ... 0x1F) can be sent as
clear text and which need to be escaped. A
bit on in the mask indicates the character
must be escaped. The mask should be specified
as an 8 hex character string (0x1F000000 and
1F000000 are both acceptable).
This MIB object corresponds to the NA/admin
asynchronous port parameter 'ppp_acm'."
::= { portEntry 62 }
anxpPppSecurityProto OBJECT-TYPE
SYNTAX INTEGER {
none(1),
pap(2),
chap(3),
chap-pap(4)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Defines which security protocol will be used
to authenticate the remote user. This
parameter must be set and the Annex
enable_security (anxEnableSecurity) must be
enabled before authentication is performed.
The default is none
This MIB object corresponds to the NA/admin
asynchronous port parameter 'ppp_security_protocol'."
::= { portEntry 63 }
anxpPppUserRemote OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The username used by the Annex to identify
itself if the remote PPP peer asks for
authentication.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'ppp_username_remote'."
::= { portEntry 64 }
anxpPppPasswdRemote OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The password used by the Annex to identify
itself if the remote PPP peer asks for
authentication. Reading this parameter
will return either <set> if the password is
defined or <unset> if the password is not
defined.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'ppp_password_remote'."
::= { portEntry 65 }
anxpLatAuthGroupVal OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..610))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This port parameter specifies which remote
group codes are accessible to a user on a
particular Annex port. Each port has its own
set of group codes. The syntax is a series
of numbers between 0 and 255, separated by
commas and dashes, such as 1,5,100-255.
The keywords 'all' and 'none' are also accepted
and will enable all or disable all groups,
respectively.
If the LAT protocol is not available on the
Annex, sets of this object are ignored.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'authorized_groups'.
Note: You may use either this object or
anxpLatAuthMap object to read or set the
'group_value' parameter.anxpLatAuthMap is
preferred."
::= { portEntry 66 }
anxpPppDialupAddr OBJECT-TYPE
SYNTAX INTEGER {
local(1),
authserver(2),
dhcp(3)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"
local(1) - Disabled.
authserver(2) - The Annex requests the
PPP dialup addresses from the host-based
ACP.
dhcp(3) - The Annex requests the
PPP dialup addresses from the host-based
DHCP.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'address_origin'."
::= { portEntry 67 }
anxpBanner OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
beforesec(3),
aftersec(4)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Specifies whether the Annex banner and message-
of-the-day are displayed on the port. The
default is enabled.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'banner'."
::= { portEntry 68 }
anxpPsHistory OBJECT-TYPE
SYNTAX INTEGER (0..32767)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Specifies how much data to buffer on a slave
port.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'ps_history_buffer'."
::= { portEntry 69 }
anxpLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"A descriptive string for a this port. This
string is displayed by the CLI who command.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'location'."
::= { portEntry 70 }
anxpType OBJECT-TYPE
SYNTAX INTEGER {
hardwired(1),
dialin(2),
x25(3),
tn3270(4),
pc(5),
terminal(6),
printer(7),
modem(8)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The type of device attached to the port. The
default is hardwired.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'type'."
::= { portEntry 71 }
anxpCliImask7 OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Defines whether input at the CLI is masked to
7 bits. The default is disabled.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'cli_imask7'."
::= { portEntry 72 }
anxpModemVar OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"A string defining the type of modem attached
to the serial port.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'type_of_modem'."
::= { portEntry 73 }
anxpPppNcp OBJECT-TYPE
SYNTAX INTEGER {
ipcp(1),
atcp(2),
all(3),
ipxcp(4),
ipcp-atcp(5),
ipcp-ipxcp(6),
atcp-ipxcp(7),
ipcp-atcp-ipxcp(8),
ipcp-ccp(9),
atcp-ccp(10),
ipxcp-ccp(11),
ipcp-atcp-ccp(12),
ipcp-ipxcp-ccp(13),
atcp-ipxcp-ccp(14),
ipcp-atcp-ipxcp-ccp(15)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The protocol running on the interface.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'ppp_ncp'.
Note that all and ipcp-atcp-ipxcp-ccp-mp are
identical and provided for backward compatibility."
::= { portEntry 74 }
-- { portEntry 75 } is reserved
anxpPhoneNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The phone number used for this port when doing
demand dialing.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'phone_number'."
::= { portEntry 76 }
anxpNetInactivity OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The number of units allowed for serial protocol
inactivity on the port. The type of unit, minutes
or seconds, is defined by the object
anxpNetInactivityUnits. If the type of units is
'seconds', the actual granularity is only 5
seconds. When the interval expires,
the port is automatically reset. A value of 0
disables the timer.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'net_inactivity'."
::= { portEntry 77 }
anxpAtGuest OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"If enabled, allows ARAP guest login service.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'at_guest'."
::= { portEntry 78 }
anxpAtNodeid OBJECT-TYPE
SYNTAX DisplayString (SIZE (3..11))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The default AppleTalk node ID hint that is
used by the Annex on this port. The address
consists of two parts separated by a dot. The
address may be in either hex or decimal format.
The first part is the network address and ranges from
0 to 65534 (0x0000 to 0xFFFE). The second part
is the node address and ranges from 0 to 254 (0x00
to 0xFE).
Example:
0x00BF.0xFD 191.253 0x00BF.253 191.0xFD
are all the same address.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'at_nodeid'."
::= { portEntry 79 }
anxpAtSecurity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Controls whether ACP service is enabled for
this port when establishing an AppleTalk
connection.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'at_security'."
::= { portEntry 80 }
anxpArapV42bis OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Controls whether V.42bis compression is done
during an ARAP session.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'arap_v42bis'."
::= { portEntry 81 }
anxpTn3270PrinterHost OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The IP address of the machine running a
Berkeley-style lpd server.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'tn3270_printer_name'."
::= { portEntry 82 }
anxpTn3270PrinterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"A valid printer name contained in the
/etc/printcap file on the remote host.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'tn3270_printer_name'."
::= { portEntry 83 }
anxpTcpKeepAlive OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The default keep-alive value for connections
to this serial port. If this is zero, use the
value specified by anxTcpKeepAlive.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'tcp_keepalive'."
::= { portEntry 84 }
-- { portEntry 85 } is reserved
anxpDtrSignal OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
high(2),
low(3)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Controls the DTR (Data Terminal Ready) output
control signal for this serial port. Valid set
values are high or low. Setting the value on an
idle port will produce an error."
::= { portEntry 86 }
anxpRtsSignal OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
high(2),
low(3)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Controls the RTS (Request to Send) output control
signal for this serial port. Valid set values are
high or low. Setting the value on an idle port will
produce an error."
::= { portEntry 87 }
anxpCliInterface OBJECT-TYPE
SYNTAX INTEGER {
uci(1),
vci(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Specifies either a Unix or VMS command line interface.
The default is uci.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'cli_interface'."
::= { portEntry 88 }
anxpAutobaud OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"When enabled, specifies that the line speed should be
determined when opening the connection. The default
is disabled.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'autobaud'."
::= { portEntry 89 }
anxpDefSessMode OBJECT-TYPE
SYNTAX INTEGER {
interactive(1),
passthru(2),
passall(3),
transparent(4)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The default session mode when the DECServer command
interface is configured. The default is interactive.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'default_session_mode'."
::= { portEntry 90 }
anxpIpxSecurity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Controls whether IPX security is enabled on
this port. The default is disabled.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'ipx_security'."
::= { portEntry 91 }
anxpIpsoClass OBJECT-TYPE
SYNTAX INTEGER {
none(1),
secret(2),
topsecret(3),
confidential(4),
unclassified(5)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Defines the IP security classification for
packets sent and received on this port. The
default value is none.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'ipso_class'."
::= { portEntry 92 }
anxpVciLoginPortPasswd OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Enables the port password if the port is
configured as a DECServer interface port.
The default is disabled.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'login_port_password'."
::= { portEntry 93 }
anxpVciLoginTimeout OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Enables a login timer if the port is configured
as a DECServer interface port. The default
is disabled.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'login_port_timeout'."
::= { portEntry 94 }
anxpDedicatedArgs OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Command line arguments to be passed to process
started by a dedicated port with mode set to
'telnet', 'tn3270', 'rlogin', 'connect' (if LAT
is in use) or 'call'.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'dedicated_arguments'."
::= { portEntry 95 }
anxpNetInactivityUnits OBJECT-TYPE
SYNTAX INTEGER {
minutes(1),
seconds(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The type of units that are used for the
port's net inactivity timer. See also the
anxpNetInactivity object. The default value
is 'minutes'.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'net_inactivity_units'."
::= { portEntry 96 }
anxpResolveProtocol OBJECT-TYPE
SYNTAX INTEGER {
connect(15),
telnet(17),
any(19)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Default host protocol to use when starting a
dedicated port and the protocol is not explicitly
specified in the command. Is set to one of
'telnet', connect, or any. Any means to try LAT
(connect) first and if that fails, try telnet.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'resolve_protocol."
::= { portEntry 97 }
anxpForwardKey OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Defines a control character sequence as an
attention character to switch the user to
the next session. The Annex-II only allows
a single control character (eg. ^A), while
the Annex3 and MicroAnnex allow a string
of control characters to be defined
(eg. ^A^B^Z).
This MIB object corresponds to the NA/admin
asynchronous port parameter 'forward_key'."
::= { portEntry 98 }
anxpBackwardKey OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Defines a control character sequence as an
attention character to switch the user to
the previous session. The Annex-II only allows
a single control character (eg. ^A), while
the Annex3 and MicroAnnex allow a string
of control characters to be defined
(eg. ^A^B^Z).
This MIB object corresponds to the NA/admin
asynchronous port parameter 'Backward_key'."
::= { portEntry 99 }
anxpPppIpxNetwork OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..8))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The IPX network number for an IPX PPP connection
using this port. When the IPX PPP connection is
established the network number will be negotiated.
If one end of the connection is set to zero then
the value from the other end of the connection will
be used.
The value of this object is an 8 digit hexadecimal
number string representing the IPX network segment
assigned to this port. The value must be unique
across the network domain.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'ppp_ipx_network'."
::= { portEntry 100 }
anxpPppIpxNode OBJECT-TYPE
SYNTAX DisplayString (SIZE(11..17))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The IPX node number for an IPX PPP connection
using this port.
The value of this object is a 12 digit
hexadecimal number string representing the IPX
node number assigned to this port.
Note the string is expected in the form:
12-3a-4-7-89-23.Each part of the address
must be a hex value separated by a hyphen.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'ppp_ipx_node'."
::= { portEntry 101 }
anxpLatAuthMap OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..32))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This port parameter is functionally identical to
anxpLatAuthGroupVal and corresponds to the
NA/admin Annex parameter 'group_value'.
The syntax of this object is an octet string
32 bytes long, with the first byte
representing groups 0 through 7 and the last
byte representing groups 248 through 255.
For example, 0x40 0x25 ... means the groups
1,10,13,15 are valid for this port.
A returned value with all bits set to zero is the
same as setting 'group_value' to 'none'.
The object always returns a string 32 bytes long.
Note: You may use either this object or
anxpLatAuthVal object to read or set the
'group_value' parameter.anxpLatAuthMap is
preferred."
::= { portEntry 102 }
anxpMultiSession OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter allows multisession operation to
be managed on a per port basis. This MIB object
corresponds to the NA/admin port parameter
'multisessions'. To enable the multisession
capability on a port, it is also necessary to enable
the service at the Annex level by setting the object
anxMultiSession to the enable value. Only when the
service is enabled at the Annex and at the port level
will it take effect.
Note: The value of this object is written in the
non-volatile memory. Thus the value takes in effect
after reboot or resetting the port."
::= { portEntry 103 }
anxpAutoTimeout OBJECT-TYPE
SYNTAX INTEGER (1..60)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter allows a user to specify the
maximum amount of time the annex should wait
before dropping into cli mode. This parameter
will specify the amount of time in seconds that
the annex will wait for a auto-detect or
auto-adapt port client's to identify itself as a
PPP or CLI client before defaulting the user into
CLI mode.
The default is 30 seconds.
This MIB object corresponds to the NA/admin
asynchronous port parameter 'autodetect-timeout'."
::= { portEntry 104 }
anxpAutoPPPSecurity OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter should be used together with the
ppp_security_protocol parameter. If this object is
set to enable and if the user comes in as CLI and
then goes into PPP mode, the annex behaves as if
the ppp_security_protocol parameter was set to
'none'. If the user is auto-detected as PPP, the
annex will use ppp_security_protocol as specified.
Finally, settting this object to disable, will not
affect the annex operation.
The default is disable(2).
This MIB object corresponds to the NA/admin
asynchronous port parameter 'ppp_sec_auto'."
::= { portEntry 105 }
-- a table of current port status and statistics
portStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortStatsEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Table of current port status entries."
::= { ports 8 }
portStatsEntry OBJECT-TYPE
SYNTAX PortStatsEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The port's current status parameters.
If the port is not in use, no values are
returned for that port."
INDEX { anxpPortStatsIndex }
::= { portStatsTable 1 }
PortStatsEntry ::= SEQUENCE {
anxpPortStatsIndex INTEGER,
anxpCurrentUserName DisplayString,
anxpPortIdleTime DisplayString,
anxpPortLoginTime DisplayString,
anxpPortProto INTEGER,
anxpPortJobs DisplayString
}
anxpPortStatsIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"A unique number from 1 to the sum of the
number of asynchronous ports, synchronous ports,
and virtual ports. The numbers from 1 to
totalPorts represent the asynchronous ports,
from totalPorts+1 to totalPorts+totalSyncPorts
represent the synchronous ports, and from
totalPorts+totalSyncPorts to
totalPorts+totalSyncPorts+128 represent the
virtual ports."
::= { portStatsEntry 1 }
anxpCurrentUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The name of the current user on this port. The
string '<unknown>' is returned if the port is in
use but the current user name cannot be determined."
::= { portStatsEntry 2 }
anxpPortIdleTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The length of time in DD:HH:MM since the
last activity on this port."
::= { portStatsEntry 3 }
anxpPortLoginTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Displays the time that the port was opened from the
Annex time-of-the-day clock."
::= { portStatsEntry 4 }
anxpPortProto OBJECT-TYPE
SYNTAX INTEGER {
cli(1),
psvr(2),
vcli(5),
dp(6),
slip(7),
lpd(8),
ppp(9),
arap(10),
ftp(11),
ndp(12),
ipx(13),
dyndial(14)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object returns the information that is similar
to when the command 'who' is typed on the CLI.
CLI - The port is a CLI port and was opened by
a device connected to the port or by a
connection from a host as a virtual CLI.
PSVR - The port is a slave port and was opened
via a network connection to the port
server.
VCLI - The port is a virtual port.
DP - The port is dedicated.
LPD- The port is the Annex line printer daemon.
PPP - The port is a PPP interface.
SLIP - The port is a SLIP interface.
ARAP - The port is a ARAP interface.
FTP - The port is a FTP interface.
IPX - The port is an IPX interface.
DYNDIAL - The port is a dynamic dial port.
Note: Values 3 and 4 are unused."
::= { portStatsEntry 5 }
anxpPortJobs OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Port Job list for this cli port."
::= { portStatsEntry 6 }
-- the parallel port parameters
anxpParaPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of parallel ports on this Annex."
::= { parallelport 1 }
-- The remainder of these parallel port objects are returned only
-- if the value of anxpParaPorts is non-zero.
anxpParaPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AnxpParaPortEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Table of parallel port parameters."
::= { parallelport 2 }
anxpParaPortEntry OBJECT-TYPE
SYNTAX AnxpParaPortEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The Annex parallel port configuration
parameters."
INDEX { anxpParaPortIndex }
::= { anxpParaPortTable 1 }
AnxpParaPortEntry ::= SEQUENCE {
anxpParaPortIndex INTEGER,
anxpParaPortHardwareTabs INTEGER,
anxpParaPortMapToUpper INTEGER,
anxpParaPortPrinterWidth INTEGER,
anxpParaPortInterface INTEGER,
anxpParaPortSpeed INTEGER,
anxpParaPortCRLF INTEGER,
anxpParaPortTcpKeepAlive INTEGER
}
anxpParaPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"A unique number from 1 to anxpParaPorts that
identifies each parallel port."
::= { anxpParaPortEntry 1 }
anxpParaPortHardwareTabs OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter controls whether the Annex
will send a tab character to the printer. If
disabled, the tab is replaced with spaces.
This MIB object corresponds to the NA/admin
parallel port parameter 'hardware_tabs'."
::= { anxpParaPortEntry 2 }
anxpParaPortMapToUpper OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"When enabled, the Annex translates all lower
case characters to upper case before
transmitting the characters to the printer
port.
This MIB object corresponds to the NA/admin
parallel port parameter 'map_to_upper'."
::= { anxpParaPortEntry 3 }
anxpParaPortPrinterWidth OBJECT-TYPE
SYNTAX INTEGER (0..132)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The defined maximum number of characters per
printer line. The Annex will insert a <newline>
character after the specified number of characters
are output on the parallel port. A value of 0
disables this feature.
This MIB object corresponds to the NA/admin
parallel port parameter 'printer_width'."
::= { anxpParaPortEntry 4 }
anxpParaPortInterface OBJECT-TYPE
SYNTAX INTEGER {
centronics(1),
dataproducts(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The type of printer attached to the port.
This MIB object corresponds to the NA/admin
parallel port parameter 'type'."
::= { anxpParaPortEntry 5 }
anxpParaPortSpeed OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
high-speed(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The printer speed on the Micro-Annex.
If this is an Annex-3 and the printer type is
Centronics, the default is 'normal'. It should
not be necessary to change the value of this
parameter.
This MIB object corresponds to the NA/admin
parallel port parameter 'printer_speed'."
::= { anxpParaPortEntry 6 }
anxpParaPortCRLF OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"When enabled, the Annex converts a carriage-return
character to carriage-return/line-feed.
This MIB object corresponds to the NA/admin
parallel port parameter 'printer_crlf'."
::= { anxpParaPortEntry 7 }
anxpParaPortTcpKeepAlive OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The default keep-alive value for connections
to this parallel port. If this is zero, use the
value specified by anxTcpKeepAlive.
This MIB object corresponds to the NA/admin
parallel port parameter 'tcp_keepalive'."
::= { anxpParaPortEntry 8 }
-- the synchronous ports group
totalSyncPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of synchronous ports on this Annex."
::= { anxsyncports 1 }
totalSyncInChars OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total number of characters received on all
synchronous ports."
::= { anxsyncports 2 }
totalSyncOutChars OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total number of characters transmitted on
all synchronous ports."
::= { anxsyncports 3 }
totalSyncFrameCheckErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total number of frame check errors detected
on all synchronous ports since the last boot."
::= { anxsyncports 4 }
totalSyncXmitUnderrunErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total number of transmit underrun errors
detected on all synchronous ports since the
last boot."
::= { anxsyncports 5 }
totalSyncRecvOverrunErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total number of receive overrun errors
detected on all synchronous ports since the
last boot."
::= { anxsyncports 6 }
-- table of synchronous port parameters
-- These objects are returned only if totalSyncPorts is non-zero.
anxSyncTable OBJECT-TYPE
SYNTAX SEQUENCE OF AnxSyncEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Table of synchronous port parameters."
::= { anxsyncports 7 }
anxSyncEntry OBJECT-TYPE
SYNTAX AnxSyncEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The synchronous port's parameters."
INDEX { anxSyncPortIndex }
::= { anxSyncTable 1 }
AnxSyncEntry ::= SEQUENCE {
anxSyncPortIndex INTEGER,
anxSyncMode INTEGER,
anxSyncClocking DisplayString,
anxSyncLocalUser DisplayString,
anxSyncPortPassword DisplayString,
anxSyncLocalAddr IpAddress,
anxSyncRemoteAddr IpAddress,
anxSyncMetric INTEGER,
anxSyncAllowCompression INTEGER,
anxSyncPppMru INTEGER,
anxSyncPppSecurityProto INTEGER,
anxSyncPppUserRemote DisplayString,
anxSyncPppPasswdRemote DisplayString,
anxSyncPppNcp INTEGER,
anxSyncLocation DisplayString,
anxSyncForceCTS INTEGER,
anxSyncSubNetMask IpAddress,
anxSyncDialupAddr INTEGER,
anxSyncPppSecurity INTEGER
}
anxSyncPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"A unique number from 1 to totalSyncPorts that
identifies each synchronous port."
::= { anxSyncEntry 1 }
anxSyncMode OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
ppp(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter defines the mode for access to
the synchronous port. The default is unused.
This MIB object corresponds to the NA/admin
synchronous port parameter 'mode'."
::= { anxSyncEntry 2 }
anxSyncClocking OBJECT-TYPE
SYNTAX DisplayString (SIZE (2..8))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The clock rate (in Kbps) supplied for this port.
The allowable values are '56', '64', '112', '128' or
'external'. The default value is 'external'.
This MIB object corresponds to the NA/admin
synchronous port parameter 'clocking'."
::= { anxSyncEntry 3 }
anxSyncLocalUser OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"A string specifying the default user name for
the port. The default value is a zero length
string.
This MIB object corresponds to the NA/admin
synchronous port parameter 'user_name'."
::= { anxSyncEntry 4 }
anxSyncPortPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The port password. The default value
is '<unset>'.
This MIB object corresponds to the NA/admin
synchronous port parameter 'port_password'."
::= { anxSyncEntry 5 }
anxSyncLocalAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Internet address for the Annex's side
of the point-to-point link.
This MIB object corresponds to the NA/admin
synchronous port parameter 'local_address'."
::= { anxSyncEntry 6 }
anxSyncRemoteAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Internet address for the host at the
remote end of the point-to-point link.
This MIB object corresponds to the NA/admin
synchronous port parameter 'remote_address'."
::= { anxSyncEntry 7 }
anxSyncMetric OBJECT-TYPE
SYNTAX INTEGER (1..15)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter defines the hop count to
the remote end of the synchronous interface.
This MIB object corresponds to the NA/admin
synchronous port parameter 'metric'."
::= { anxSyncEntry 8 }
anxSyncAllowCompression OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"When enabled, the Annex will use TCP/IP
header compression on this link only
if the other end of the link initiates
the compression.
This MIB object corresponds to the NA/admin
synchronous port parameter 'allow_compression'."
::= { anxSyncEntry 9 }
anxSyncPppMru OBJECT-TYPE
SYNTAX INTEGER (64..1500)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This parameter defines the maximum receive
unit in bytes. The default value is 1500.
This MIB object corresponds to the NA/admin
synchronous port parameter 'ppp_mru'."
::= { anxSyncEntry 10 }
anxSyncPppSecurityProto OBJECT-TYPE
SYNTAX INTEGER {
none(1),
pap(2),
chap(3),
chappap(4)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Defines which security protocol will be used
to authenticate the remote user. This
parameter must be set and the Annex
enable_security (anxEnableSecurity) must be
enabled before authentication is performed.
The default is none.
This MIB object corresponds to the NA/admin
synchronous port parameter 'ppp_security_protocol'."
::= { anxSyncEntry 11 }
anxSyncPppUserRemote OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The username used by the Annex to identify
itself if the remote PPP peer asks for
authentication. Reading this parameter
will return either <set> if the username is
defined or <unset> if the username is not
defined.
This MIB object corresponds to the NA/admin
synchronous port parameter 'ppp_username_remote'."
::= { anxSyncEntry 12 }
anxSyncPppPasswdRemote OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The username used by the Annex to identify
itself if the remote PPP peer asks for
authentication. Reading this parameter
will return either <set> if the password is
defined or <unset> if the password is not
defined.
This MIB object corresponds to the NA/admin
synchronous port parameter 'ppp_password_remote'."
::= { anxSyncEntry 13 }
anxSyncPppNcp OBJECT-TYPE
SYNTAX INTEGER {
ipcp(1),
atcp(2),
all(3),
ipxcp(4),
ipcp-atcp(5),
ipcp-ipxcp(6),
atcp-ipxcp(7),
ipcp-atcp-ipxcp(8),
ipcp-ccp(9),
atcp-ccp(10),
ipxcp-ccp(11),
ipcp-atcp-ccp(12),
ipcp-ipxcp-ccp(13),
atcp-ipxcp-ccp(14),
ipcp-atcp-ipxcp-ccp(15)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The protocol running on the interface.
This MIB object corresponds to the NA/admin
synchronous port parameter 'ppp_ncp'."
::= { anxSyncEntry 14 }
anxSyncLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"A string specifying location information for
the port. The default value is a zero length
string.
This MIB object corresponds to the NA/admin
synchronous port parameter 'location'."
::= { anxSyncEntry 15 }
anxSyncForceCTS OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Allows the control of CTS for the synchronous
port. If disabled, CTS will assume the level
of the interface. If the attached device does
not assert CTS, this parameter must be set to
enabled for proper operation. The default value
is 'disabled'.
This MIB object corresponds to the NA/admin
synchronous port parameter 'force_CTS'."
::= { anxSyncEntry 16 }
anxSyncSubNetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The subnet mask address for the
local end of the point-to-point link.
This MIB object corresponds to the NA/admin
synchronous port parameter 'subnet_mask'."
::= { anxSyncEntry 17 }
anxSyncDialupAddr OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"When enabled, the Annex requests the
PPP dialup addresses from the host-based
ACP for this synchronous port.
This MIB object corresponds to the NA/admin
synchronous port parameter 'dialup_addresses'."
::= { anxSyncEntry 18 }
anxSyncPppSecurity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The master security switch for this synchronous
port. When enabled, the value of the
anxSyncPppSecurityProto object determines the
security protocol to use.
This MIB object corresponds to the NA/admin
synchronous port parameter 'ppp_security'."
::= { anxSyncEntry 19 }
--
-- Modem MIB group(s)
--
-- The call accounting table. This is deprecated by the callHistTable.
anxmStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AnxmStatsEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Table of phone call statistics and accounting
parameters. This information is cleared each
time the Annex is rebooted. The maximum number
of entries is defined by the current value
of the object anxMaxModemCalls. When the
number of archived calls exceeds the defined
maximum, the oldest terminated call is replaced
by the new call information."
::= { anxModem 1 }
anxmStatsEntry OBJECT-TYPE
SYNTAX AnxmStatsEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The modem statistics and accounting parameter
objects."
INDEX { anxmStatsIndex }
::= { anxmStatsTable 1 }
AnxmStatsEntry ::= SEQUENCE {
anxmStatsIndex INTEGER,
anxmStatsPort INTEGER,
anxmStatsModemType DisplayString,
anxmStatsTime DisplayString,
anxmStatsNumber DisplayString,
anxmStatsDuration TimeTicks,
anxmStatsUsername DisplayString,
anxmStatsStatus INTEGER
}
anxmStatsIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"A unique number generated to identify the
particular call."
::= { anxmStatsEntry 1 }
anxmStatsPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The port number on which phone call took place."
::= { anxmStatsEntry 2 }
anxmStatsModemType OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..16))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The type of modem which was on the port at the
time of the call."
::= { anxmStatsEntry 3 }
anxmStatsTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The time when the phone call was initiated."
::= { anxmStatsEntry 4 }
anxmStatsNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..24))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number to which this call was made. If
the call was not initiated by the Annex, this
is value is returned as a zero length string."
::= { anxmStatsEntry 5 }
anxmStatsDuration OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Duration of the phone call."
::= { anxmStatsEntry 6 }
anxmStatsUsername OBJECT-TYPE
SYNTAX DisplayString (SIZE (2..32))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Name of the user associated with this port at
the time of the call."
::= { anxmStatsEntry 7 }
anxmStatsStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
exitNormal(2),
exitAbort(3)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Describes the status of the call; active,
normal termination, or aborted."
::= { anxmStatsEntry 8 }
-- This new object is a member of the async portEntry configuration
-- table. This should really be done via an AUGMENTS definition when
-- we support the SNMPv2 SMI. Please refer to the Annex MIB for more
-- information.
anxpModemTable OBJECT-TYPE
SYNTAX SEQUENCE OF AnxpModemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of modem configuration information
for the ports."
::= { anxModem 2 }
anxpModemEntry OBJECT-TYPE
SYNTAX AnxpModemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the port's modem configuration table."
INDEX { anxpModemIndex }
::= { anxpModemTable 1 }
AnxpModemEntry ::= SEQUENCE {
anxpModemIndex INTEGER,
anxpModemConfig INTEGER,
anxpModemReset INTEGER,
anxpModemStatus INTEGER,
anxpModemBChannel INTEGER,
anxpModemWhenBusy INTEGER,
anxpModemTotalCalls Counter,
anxpModemRingFail Counter,
anxpModemOffhookFail Counter,
anxpModemDcdFail Counter,
anxpModemConsecFail Counter,
anxpModemFirmware DisplayString
}
anxpModemIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number for this modem configuration."
::= { anxpModemEntry 1 }
anxpModemConfig OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
none(2),
dialinautobaud(3),
dialin(4),
dialinoutautobaud(5),
dialinout(6),
dialout(7),
autodetect(8),
autoadapt(9),
ipx(10)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The purpose for which this modem is configured.
When set, this object will change a set of parameters
to configure the modem for the specified purpose.
The value 'unknown' is read only, and may be returned
upon read if the modem is not configured to one of
the states listed above. Setting this object to
'unknown' will return an error.
The value 'none(2)' is not valid for hardware types
csmim-t1 and ra6100.
For RA6300, only valid option is dialin(4)."
::= { anxpModemEntry 2 }
anxpModemReset OBJECT-TYPE
SYNTAX INTEGER {
ready(1),
execute(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"A control to force the internal modem into a
clean, initial state, through a hardware
reset. In response to a get-request or
get-next-request, the agent always returns
'ready' as the value. Settingthe value to
execute(2) - Busy out modem. If the modem is
busy, then busy it after call is
completed.
For RA6300, this MIB object corresponds to the
NA/admin port parameter 'modem -u <modem number>'.
This is valid only for T1CSMIM and RA6300
boards."
::= { anxpModemEntry 3 }
anxpModemStatus OBJECT-TYPE
SYNTAX INTEGER {
available(1),
busied-out(2),
failed(3),
used(4)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object sets the status of the modem.
Explanation of the values are as follows:
1 - Make modem available if busied out.
2 - Busy out a modem.
3 - Boot-up diagnostic has marked this modem
as failed.
4 - Modem is handling a call.
This MIB object corresponds to the NA/admin
port parameter 'modem -m <modem number>'.
This object valid for RA6300 only."
::= { anxpModemEntry 4 }
anxpModemBChannel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object returns the B channel number
that is using the modem. This object is valid only if
the status of the modem is used.
This MIB object displays the similar information
as the NA/admin command 'modem -m <modem number>' and
the modem status is used.
This object valid for RA6300 only."
::= { anxpModemEntry 5 }
-- this object may be removed
anxpModemWhenBusy OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object returns when the modem was
busied out. This object is valid only when the modem
status is busied-out(2).
This MIB object displays the similar information
as the NA/admin command 'modem -m <modem number>' and
the modem status is busied out.
This object valid for RA6300 only."
::= { anxpModemEntry 6 }
-- the following 5 objects gives the statistics of call failures on a modem.
-- A call can fail at various stage. When a call arrives it is termed as line
-- seizure. After a line is seized the ring is asserted by the modem and then
-- the modem goes offhook. Finally when the modem accepts a call it asserts
-- (raises) the DCD.
-- These objects could be used to help to identify a bad modem.
anxpModemTotalCalls OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object maintains the count of number of times
the line is seized on a modem. The line is seized when a call
arrives on that line."
::= { anxpModemEntry 7 }
anxpModemRingFail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object maintains the count of number of times
the modem failed to ring on a call. The counter is maintained
since the last reboot."
::= { anxpModemEntry 8 }
anxpModemOffhookFail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object maintains the count of number of times
the modem failed to go offhook on a call. The counter is
maintained since the last reboot."
::= { anxpModemEntry 9 }
anxpModemDcdFail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object maintains the count of number of times
the modem failed to assert DCD on a call. The DCD is asserted
when a call is accepted by the modem. The counter is
maintained since the last reboot."
::= { anxpModemEntry 10 }
anxpModemConsecFail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object maintains the count of number of times
the modem failed to accept a call consecutively. The counter
gets initialized on every successfull call or when the counter
value reaches threshold and the modem is busyied out.
This object along with the above fail statistics objects could
help in isolating a bad modem."
::= { anxpModemEntry 11 }
anxpModemFirmware OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..80))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Modem firmware version string.
Note: If the object returns a Nosuchname then
it is possible that modem is being upgraded by
AFD or some other tool."
::= { anxpModemEntry 12 }