snmp_mib_archive/hpipf02trap.cfg
Heston Snodgrass 89bf4b016e initial commit
2016-12-15 15:03:18 -07:00

875 lines
17 KiB
INI
Executable File

#-MIBFILE: hpipf02trap.mib
HPIPF02TRAP-MIB DEFINITIONS ::= BEGIN
DisplayString ::=
OCTET STRING
PhysAddress ::=
OCTET STRING
hp OBJECT IDENTIFIER ::= { enterprises 11 }
nm OBJECT IDENTIFIER ::= { hp 2 }
hpnsa OBJECT IDENTIFIER ::= { nm 23 }
hpIpfE0Events OBJECT IDENTIFIER ::= { hpnsa 35 }
hpIpf02Events OBJECT IDENTIFIER ::= { hpnsa 45 }
hpIpfEvtDetailStr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This string provides a detailed description of the Event along with variable information."
::= { hpIpf02Events 1 }
hpTempHighWarning752 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Temperature sensor crossed lower noncritical threshold"
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "One of the temperature sensors crossed its lower non-critical threshold."
::= 752
hpTempHighCritical753 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "A temperature inside the server went far outside the factory specified range"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "One of the temperature sensors crossed its upper critical threshold."
::= 753
hpTempHighNonRecoverable754 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Temperature sensor crossed upper nonrecoverable threshold."
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "One of the temperature sensors crossed its upper non-recoverable threshold."
::= 754
hpTemperature4 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "A temperature inside the server has gone outside the factory specified range."
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "One of the temperature sensors crossed its upper non-critical threshold."
::= 4
hpTemperature5 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "A temperature inside the server has gone far outside the factory specified range."
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "One of the temperature sensors crossed its upper critical threshold."
::= 5
hpTemperature6 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Temperature sensor crossed upper nonrecoverable threshold"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "One of the temperature sensors crossed its upper non-recoverable threshold."
::= 6
hpTemperature755 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "One of the temperature sensors crossed its upper noncritical threshold."
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "A temperature inside the server has gone outside the factory specified range."
::= 755
hpTemperature756 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "A temperature inside the server went far outside the factory specified range."
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "One of the temperature sensors crossed its upper critical threshold."
::= 756
hpEnvironment8 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "A measured voltage in the server has gone far outside the factory specified lower voltage range."
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "One of the voltage sensors crossed its lower critical threshold."
::= 8
hpEnvironment9 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Voltage sensor crossed lower nonrecoverable threshold"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "One of the voltage sensors crossed its lower non-recoverable threshold."
::= 9
hpEnvironment10 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "A measured voltage in the server has gone outside the factory specified upper voltage range."
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "One of the voltage sensors crossed its upper non-critical threshold."
::= 10
hpEnvironment12 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Voltage sensor crossed upper nonrecoverable threshold"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "One of the voltage sensors crossed its upper non-recoverable threshold - Check all boards with this voltage"
::= 12
hpEnvironment704 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Voltage insufficient"
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "Voltage fault - Check all boards with this voltage"
::= 704
hpEnvironment728 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Voltage reached critical level"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "Voltage degraded to critical level from less severe - Check all boards with this voltage"
::= 728
hpEnvironment705 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Voltage reached critical level"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "Voltage degraded to non-recoverable level from less severe - Check all boards with this voltage"
::= 705
hpEnvironment706 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Power Pod Voltage Fault"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "Voltage becomes non-recoverable from either critical level or less severe level - Check all boards with this voltage"
::= 706
hpEnvironment707 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Voltage absent"
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "Voltage absent"
::= 707
hpFan710 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Fan speed lags"
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "Fan speed lags"
::= 710
hpChassis26 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "The server's builtin sensors have detected an open chassis door."
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "The chassis has been opened."
::= 26
hpBmcFirmware730 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "The BMC firmware did not detect the system firmware boot"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "The BMC firmware did not detect the system firmware boot."
::= 730
hpRedundantPower720 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Power supply failure"
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "Power supply failed or disconnected"
::= 720
hpRedundantPower732 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "The power supply sensors detect a possible problem"
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "The Power supply's sensors detect possible problems"
::= 732
hpRedundantPower722 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Power supply AC lost"
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "Power supply AC lost"
::= 722
hpRedundantPower757 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "The AC voltage to the power supply was lost or is out of range."
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "The Power Supply AC voltage was lost or is out of range."
::= 757
hpRedundantPower758 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "The power supply AC voltage is out of range."
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "The AC voltage connected to the power supply is out of range."
::= 758
hpPowerSupply731 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "A/C Power failed, disconnected, or out of range"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "A/C Failed, disconnected, or out of range"
::= 731
hpPowerSupply726 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Power failure in power supply"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "A/C Failed, disconnected, or out of range"
::= 726
hpSystemHW733 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Cooling unit warning"
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "Cooling unit warning"
::= 733
hpSystemHW734 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Cooling unit failure"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "Cooling unit failure"
::= 734
hpECCMemory518 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Uncorrectable multibit ECC error has occurred"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "Uncorrectable multi-bit ECC error has occurred in memory module"
::= 518
hpSystemFW700 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Generic trap for Critical or Fatal type E0 event from system firmware"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "System firmware error"
::= 700
hpSystemHW744 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "System event log almost full"
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "System event log almost full"
::= 744
hpSystemHW735 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "BMC entering special mode"
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "BMC entering special mode"
::= 735
hpSystemHW729 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "System shutdown or reset caused by sensor reading"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "System shut-down or reset caused by sensor reading. "
::= 729
hpSystemHW745 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "TOC interrupt (crash dump)"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "TOC interrupt (crash dump)"
::= 745
hpSystemHW746 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "INIT Initiated"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "INIT Initiated"
::= 746
hpSystemHW751 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "PCI parity error detected"
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "PCI parity error detected"
::= 751
hpSystemHW747 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "PCI system error detected"
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "PCI system error detected"
::= 747
hpSystemFW699 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Machine Check Initiated"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "Machine Check Initiated"
::= 699
hpSystemHW113 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Hot Swap Cage: SCSI cable removed"
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "A SCSI cable has been removed from the hot swap cage."
::= 113
hpSystemHW748 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "OS runtime critical shutdown"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "OS run-time critical shutdown"
::= 748
hpSystemHW749 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "ACPI state S5 (softoff, entered by override)"
--#ARGUMENTS {}
--#SEVERITY WARNING
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "ACPI state S5 (soft-off, entered by override)"
::= 749
hpSystemHW736 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Watchdog timer expired hard reset"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "Watchdog timer expired - hard reset"
::= 736
hpSystemHW737 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Watchdog timer expired poweroff"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "Watchdog timer expired - power-off"
::= 737
hpSystemHW738 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Watchdog timer expired powercycle"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "Watchdog timer expired - power-cycle"
::= 738
hpSystemHW739 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Missing FRU device"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "Missing FRU device"
::= 739
hpSystemHW740 TRAP-TYPE
ENTERPRISE hpIpf02Events
VARIABLES { hpIpfEvtDetailStr }
--#SUMMARY "Missing Entity"
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 100
--#STATE OPERATIONAL
--#CATEGORY "Integrity Server Events"
DESCRIPTION "Missing Entity"
::= 740
END