snmp_mib_archive/cpqinfo.mib
Heston Snodgrass 89bf4b016e initial commit
2016-12-15 15:03:18 -07:00

3654 lines
134 KiB
Plaintext
Executable File
Raw Blame History

-- ****************************************************************************
-- :CPQ,DEV:
--
-- * COMPAQ SYSTEM INFORMATION SNMP MIB DEFINITIONS
--
-- * $Date: 2003-06-11 04:58:24 +0530 (Wed, 11 Jun 2003) $
-- * $Revision: 6049 $
--
-- Compaq Computer Corporation
-- Confidential - Need To Know
-- ****************************************************************************
-- :CPQ,ENDDEV:
--
-- Compaq System Information
-- Management Information Base for SNMP Network Management
--
--
-- Copyright 1992-2001 Compaq Computer Corporation.
-- All Rights Reserved.
--
-- The information in this document is subject to change without notice.
--
-- COMPAQ COMPUTER CORPORATION SHALL NOT BE LIABLE FOR TECHNICAL
-- OR EDITORIAL ERRORS OR OMISSIONS CONATINED HEREIN; NOR FOR INCIDENTAL
-- OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FURNISHING, PERFORMANCE,
-- OR USE OF THIS MATERIAL.
--
-- Refer to the READMIB.RDM file for more information about the
-- organization of the information in the Compaq Enterprise.
--
-- The Compaq Enterprise number is 232.
-- The ASN.1 prefix to, and including the Compaq Enterprise is:
-- 1.3.6.1.4.1.232
--
-- ****************************************************************************
CPQSINFO-MIB DEFINITIONS ::= BEGIN
IMPORTS
compaq FROM CPQHOST-MIB
enterprises FROM RFC1155-SMI
DisplayString FROM RFC1213-MIB
OBJECT-TYPE FROM RFC-1212
sysName FROM RFC1213-MIB
cpqHoTrapFlags FROM CPQHOST-MIB
TRAP-TYPE FROM RFC-1215;
-- compaq OBJECT IDENTIFIER ::= { enterprises 232 }
cpqSystemInfo OBJECT IDENTIFIER ::= { compaq 2 }
cpqSiMibRev OBJECT IDENTIFIER ::= { cpqSystemInfo 1 }
cpqSiComponent OBJECT IDENTIFIER ::= { cpqSystemInfo 2 }
cpqSiInterface OBJECT IDENTIFIER ::= { cpqSiComponent 1 }
cpqSiAsset OBJECT IDENTIFIER ::= { cpqSiComponent 2 }
cpqSiSecurity OBJECT IDENTIFIER ::= { cpqSiComponent 3 }
cpqSiSystemBoard OBJECT IDENTIFIER ::= { cpqSiComponent 4 }
cpqSiBoardRev OBJECT IDENTIFIER ::= { cpqSiComponent 5 }
cpqSiRackServer OBJECT IDENTIFIER ::= { cpqSiComponent 6 }
-- :CPQ,DEV:
-- cpqSiVideo deprecated in 3.40 release
-- :CPQ,ENDDEV:
cpqSiVideo OBJECT IDENTIFIER ::= { cpqSiComponent 7 }
cpqSiMonitor OBJECT IDENTIFIER ::= { cpqSiComponent 8 }
cpqSiHotPlugSlot OBJECT IDENTIFIER ::= { cpqSiComponent 9 }
cpqSiSystemBattery OBJECT IDENTIFIER ::= { cpqSiComponent 10 }
cpqSiDockingStation OBJECT IDENTIFIER ::= { cpqSiComponent 11 }
cpqSiFru OBJECT IDENTIFIER ::= { cpqSiComponent 12 }
cpqSiRackEnclosure OBJECT IDENTIFIER ::= { cpqSiComponent 13 }
cpqSiOsCommon OBJECT IDENTIFIER ::= { cpqSiInterface 4 }
-- ****************************************************************************
-- Compaq System Information MIB Revision
-- ======================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiMibRev Group (1.3.6.1.4.1.232.2.1)
--
-- Implementation of the MibRev group is mandatory for all Insight Agents
-- supporting the Compaq System Information MIB.
--
-- An Agent conforming to this document will return a
-- cpqSiMibRevMajor of one (1) and a cpqSiMibRevMinor of nineteen (19).
--
-- :CPQ,DEV:
-- MIB Rev of 1.3 is for AUGUSTA time frame
-- MIB Rev of 1.4 is for 2Q94 release time frame
-- MIB Rev of 1.5 is for 1Q95 release time frame
-- MIB Rev of 1.6 is for 2.50 release time frame.
-- MIB Rev of 1.7 is for 2.60 release time frame and implies support for:
-- - cpqSiAssetTag variable
-- - cpqSiVideo group
-- MIB Rev of 1.8 is for 3.00 release time frame - items added:
-- - cpqSiProcMicroPatchTable
-- MIB Rev of 1.9 is for 3.10 release time frame - items added:
-- - cpqSiHoodRemoved trap
-- - cpqSiPowerMgmtStatus
-- - cpqSiRebootFlags
-- - deprecated cpqSiReboot
-- - cpqSiHoodRemovedTime
-- MIB Rev of 1.10 is for 3.40 release time frame - items added:
-- - new cpqSiHotPlugSlot group
-- cpqSiHotPlugSlotTable
-- - new itmes in cpqSiSecurity Group
-- cpqSiHoodSensorConfiguration, cpqSiSmartCoverLockStatus
-- - new items in cpqSiMemModule Table:
-- cpqSiMemModuleTechnology, cpqSiMemModuleVendor
-- cpqSiMemModulePartNo, cpqSiMemModuleDate
-- cpqSiMemModuleSerialNo, cpqSiMemModuleECCStatus
-- - new items in cpqSiSystemBoard Group
-- cpqSiMemECCCondition, cpqSiMemErrorIndex,
-- cpqSiMemConfigChangeData
-- - deprecate cpqSiVideo Group (now cpqSiMonitorTable)
-- - new cpqSiMonitor Group
-- cqSiMonitorOverallCondition, cpqSiMonitorTable
-- - new traps
-- cpqSiMonitorConditionOK, cpqSiMonitorConditionDegraded
-- cpqSiMonitorConditionFailed,
-- cpqSiCorrMemErrStatusDegraded, cpqSiCorrMemErrStatusOk
-- cpqSiMemConfigChange
-- MIB Rev of 1.11 is for 3.50 release time frame - items added:
-- - new item in cpqSiAsset Group
-- cpqSiOwnershipTag
-- - new items in cpqSiSecurity Group
-- cpqSiUSBPortControl
-- - new group cpqSiSystemBattery
-- cpqSiSystemBatteryOverallCondition and
-- cpqSiSystemBatteryTable
-- - new cpqSiDockingStation with leafs
-- - new traps
-- cpqSiSysBatteryFailure
-- MIB Rev of 1.12 is for Koala (4.0/3.70) release time frame.
-- MIB Rev of 1.13 is for Dingo (4.20) release time frame.
-- - new item in cpqSiAsset Group
-- cpqSiSysServiceNum
-- - added cpqSiSysBatteryFirmwareRevision
-- - added cpqSiSysBatteryHardwareRevision
-- - added cpqSiSysBatteryFullCap and cpqSiSysBatteryDesignCap
-- - added capacityDegraded enum to cpqSiSysBatteryStatus
-- - added cpqSiSysBatteryChargingDegraded trap
-- - added cpqSiSysBatteryCalibrationError trap
-- MIB Rev of 1.14 is for Maremma (4.21) release time frame.
-- - added rimm and srimm enum to cpqSiMemModuleType
-- - added rdram enum to cpqSiMemModuleTechnology
-- MIB Rev of 1.15 is for release 4.23.
-- - deprecates cpqSiOsCommonModuleTable.
-- MIB Rev of 1.16 is for 4.30 release time frame.
-- NOTE: This revision also includes support for Digital Servers
-- - added support for cpqSiFirmwareRevTable
-- - added support for cpqSiFirmwareCfgTable
-- - added support for cpqSiFruTable
-- MIB Rev of 1.17 is for 4.50 release time frame.
-- - added new enumerations for cpqSiHotPlugSlotErrorStatus
-- - added cpqSiServerSystemId
-- MIB Rev of 1.18 is for 5.00 release time frame.
-- - addition of optional location table elements for partitioned
-- systems.
-- MIB Rev of 1.19 is for 5.30 release time frame.
-- - added cpqSiRackEnclosure information for rack and enclosure
-- managed systems.
--
-- ****************************************************************************
--
--
-- :CPQ,ENDDEV:
--
-- ****************************************************************************
cpqSiMibRevMajor OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The major revision level of the MIB.
A change in the major revision level represents a major change
in the architecture of the MIB. A change in the major revision
level may indicate a significant change in the information
supported and/or the meaning of the supported information,
correct interpretation of data may require a MIB document with
the same major revision level."
::= { cpqSiMibRev 1 }
cpqSiMibRevMinor OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minor revision level of the MIB.
A change in the minor revision level may represent some minor
additional support, no changes to any pre-existing information
has occurred."
::= { cpqSiMibRev 2 }
cpqSiMibCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2), -- default
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The overall condition.
This object represents the overall status of the Compaq server
information represented by this MIB."
::= { cpqSiMibRev 3 }
-- ****************************************************************************
-- Compaq System Information Common
-- ================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiInterface Group (1.3.6.1.4.1.232.2.2.1)
-- cpqSiOsCommon Group (1.3.6.1.4.1.232.2.2.1.4)
--
--
-- Implementation of the cpqSiOsCommon group is mandatory for all
-- Insight Agents that support the System Information MIB.
--
-- ****************************************************************************
cpqSiOsCommonPollFreq OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Insight Agent's polling frequency.
The frequency, in seconds, at which the Insight Agent requests
information from the device driver. A frequency of zero (0)
indicates that the Insight Agent retrieves the information upon
request of a management station, it does not poll the device
driver at a specific interval.
If the poll frequency is zero (0) all attempts to write to this
object will fail. If the poll frequency is non-zero,
setting this value will change the polling frequency of the
Insight Agent. Setting the poll frequency to zero (0) will
always fail, an agent may also choose to fail any request to
change the poll frequency to a value that would severely impact
system performance."
::= { cpqSiOsCommon 1 }
-- ****************************************************************************
-- Compaq System Information Common Module Table
-- =============================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiInterface Group (1.3.6.1.4.1.232.2.2.1)
-- cpqSiOsCommon Group (1.3.6.1.4.1.232.2.2.1.4)
-- cpqSiOsCommonModuleTable (1.3.6.1.4.1.232.2.2.1.4.2) deprecated
--
-- ****************************************************************************
cpqSiOsCommonModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSiOsCommonModuleEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A table of software modules that provide an interface to the
device this MIB describes."
::= { cpqSiOsCommon 2 }
cpqSiOsCommonModuleEntry OBJECT-TYPE
SYNTAX CpqSiOsCommonModuleEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A description of a software module that provides an interface
to the device this MIB describes."
INDEX { cpqSiOsCommonModuleIndex }
::= { cpqSiOsCommonModuleTable 1 }
CpqSiOsCommonModuleEntry ::= SEQUENCE {
cpqSiOsCommonModuleIndex INTEGER,
cpqSiOsCommonModuleName DisplayString,
cpqSiOsCommonModuleVersion DisplayString,
cpqSiOsCommonModuleDate OCTET STRING,
cpqSiOsCommonModulePurpose DisplayString
}
cpqSiOsCommonModuleIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"A unique index for this module description."
::= { cpqSiOsCommonModuleEntry 1 }
cpqSiOsCommonModuleName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The module name."
::= { cpqSiOsCommonModuleEntry 2 }
cpqSiOsCommonModuleVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..5))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The module version in XX.YY format.
Where XX is the major version number and YY is the minor version
number. This field will be a null (size 0) string if the agent
cannot provide the module version."
::= { cpqSiOsCommonModuleEntry 3 }
cpqSiOsCommonModuleDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The module date.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the module date. The hour, minute, and second field will be set
to zero (0) if they are not relevant. The year field is set
with the most significant octect first."
::= { cpqSiOsCommonModuleEntry 4 }
cpqSiOsCommonModulePurpose OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The purpose of the module described in this entry."
::= { cpqSiOsCommonModuleEntry 5 }
-- ****************************************************************************
-- Compaq System Information Asset Group
-- =====================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiAsset Group (1.3.6.1.4.1.232.2.2.2)
--
-- The cpqSiAsset group contains the serial numbers of any Compaq hardware
-- that supports asset management.
--
-- Implementation of the cpqSiAsset group is mandatory for all Insight
-- Agents that support the Compaq System Information MIB.
--
-- ****************************************************************************
cpqSiSysSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial number of the system unit.
The string will be empty if the system does not report the
serial number function."
::= { cpqSiAsset 1 }
cpqSiFormFactor OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
portable(2),
laptop(3),
desktop(4),
tower(5),
mini-tower(6),
rack-mount(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The form factor of the system. Setting this variable to
unknown will fail."
::= { cpqSiAsset 2 }
-- :CPQ,DEV:
-- This information comes out of the SIT's general peripheral and input
-- information ( ID 07h) byte 04h. Today there is no way to tell if the
-- system is raq-mount or not so the following system EV is defined:
-- CQHCIM:
-- BYTE 0 : Bit 0 : 0 - non-rackmount system
-- 1 - rackmount system
-- Bit 1-7 : reserved
-- Form factor Information in CQHCIM, if it exists, will always override
-- the form factor type in the SIT. The agent should set CQHCIM appropriately
-- when this variable is set to rack-mount(7).
--
-- :CPQ,ENDDEV:
cpqSiAssetTag OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The customer changeable identifier that is set to the system
serial number at the time of manufacture.
The string will be empty if the system does not report this
function."
::= { cpqSiAsset 3 }
cpqSiOwnershipTag OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..79))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a customer changeable identifier that will be
displayed by ROM at POST. This is an 80 byte standard
ASCII character string and is Administrator Password
protected.
An example could be:
Property of Compaq Computer Corporation
The string should be NULL terminated. This item will be
empty if the system does not report this function."
-- :CPQ,DEV:
--
-- This is for the Desktop Agents.
--
-- :CPQ,ENDDEV:
::= { cpqSiAsset 4 }
cpqSiSysServiceNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The service number of the system unit.
The string will be empty if the system does not report the
system service number."
-- :CPQ,DEV:
-- This number is taken from the CQHSRV ev.
-- :CPQ,ENDDEV:
::= { cpqSiAsset 5 }
-- ****************************************************************************
-- Compaq System Information Security Group
-- ========================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiSecurity Group (1.3.6.1.4.1.232.2.2.3)
--
-- The Security group describes how the security features on your Compaq
-- computer are currently configured.
--
-- Implementation of the security group is mandatory for all agents that
-- support the Compaq System Information MIB.
--
-- ****************************************************************************
cpqSiPowerOnPassword OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the power on password feature."
::= { cpqSiSecurity 1 }
cpqSiNetServerMode OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the network server mode feature."
::= { cpqSiSecurity 2 }
cpqSiQuickLockPassword OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the quicklock password feature."
::= { cpqSiSecurity 3 }
cpqSiQuickBlank OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the quick blank screen feature."
::= { cpqSiSecurity 4 }
cpqSiDisketteBootControl OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the diskette boot control feature."
::= { cpqSiSecurity 5 }
cpqSiSerialPortAControl OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the access control for the primary serial port
interface embedded in the Compaq system board."
::= { cpqSiSecurity 6 }
cpqSiSerialPortBControl OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the access control for the secondary serial port
interface embedded in the Compaq system board."
::= { cpqSiSecurity 7 }
cpqSiParallelPortControl OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the access control for the parallel port interface
embedded in the Compaq system board."
::= { cpqSiSecurity 8 }
cpqSiFloppyDiskControl OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the access control for the floppy diskette
interface embedded in the Compaq system board."
::= { cpqSiSecurity 9 }
cpqSiFixedDiskControl OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the access control for the fixed disk interface
embedded in the Compaq system board."
::= { cpqSiSecurity 10 }
cpqSiHoodRemovedTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Last detection of hood removed by Compaq Smart Hood Sensor."
-- :CPQ,DEV:
-- This is for the Desktop Agents. Server agents do not need to
-- support this variable in the 3.1 time frame.
--
-- Time and date format should be local specific and should include
-- MM/DD/YYYY HH:MM:SS
-- :CPQ,ENDDEV:
::= { cpqSiSecurity 11 }
cpqSiHoodSensorConfiguration OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
notifyUser(3),
adminPasswordProtected(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the current configuration of the Compaq Smart Cover
sensor.
The following values are currently defined:
other(1)
Smart Cover sensor is not supported on this system or cannot
be determined by the Insight Agent. You may need to upgrade
your software.
disabled(2)
Smart Cover sensor will not detect a hood removal and
cpqSiHoodRemovedTime will not be updated.
notifyUser(3)
Smart Cover sensor will detect a hood removal and will display
a message at POST for the user.
adminPasswordProtected(4)
Smart Cover sensor will detect a hood removal and will display
a message at POST for the user to enter the Admin Password.
The system will not boot until proper password is entered."
::= { cpqSiSecurity 12 }
cpqSiSmartCoverLockStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unlocked(2),
locked(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the current status of the Compaq Smart Cover
Lock. The following values are currently defined:
other(1)
Smart Cover Lock is not supported on this system or cannot
be determined by the Insight Agent. You may need to upgrade
your software.
unlocked(2)
Smart Cover Lock is not locked. The status will be set to
unlocked due to one of the following:
1. The system hood is removed, or
2. There is no administrator password set, or
3. The administrator manually sets status to unlock.
locked(3)
Smart Cover Lock is locked. The administrator password is
required to unlock the hood."
-- :CPQ,DEV:
-- This lock will be implemented in certain Desktops.
-- :CPQ,ENDDEV:
::= { cpqSiSecurity 13 }
cpqSiUSBPortControl OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the access control for the Universal
Serial Bus interface(s) embedded in the Compaq system
board."
::= { cpqSiSecurity 14 }
-- ****************************************************************************
-- Compaq System Information System Board Group
-- ============================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiSystemBoard Group (1.3.6.1.4.1.232.2.2.4)
--
-- The cpqSiSystemBoard group describe features of your Compaq computer
-- system board.
--
-- Implementation of the cpqSiSystemBoard group is mandatory for all agents
-- that support the Compaq System Information MIB.
--
-- ****************************************************************************
cpqSiProductId OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The machine product ID.
This value indicates the Compaq product type of the system board
in this system. The value 127 will be given if the machine ID
cannot be determined. A value of 127 will also be used for the
special case of a machine containing neither EISA nor ISA slots."
::= { cpqSiSystemBoard 1 }
cpqSiProductName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The machine product name.
The name of the Compaq machine used in this system."
-- :CPQ,DEV:
-- If the Compaq machine name cannot be determined, this item
-- should return the following generic string:
-- Compaq Personal Computer
--
-- :CPQ,ENDDEV:
::= { cpqSiSystemBoard 2 }
cpqSiAuxiliaryInput OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the auxiliary input (pointing) device."
::= { cpqSiSystemBoard 4 }
-- ****************************************************************************
-- Compaq System Information Memory Module Table
-- =============================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiSystemBoard Group (1.3.6.1.4.1.232.2.2.4)
-- cpqSiMemModuleTable (1.3.6.1.4.1.232.2.2.4.5)
-- cpqSiMemModuleEntry (1.3.6.1.4.1.232.2.2.4.5.1)
--
-- ****************************************************************************
cpqSiMemModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSiMemModuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of memory module descriptions."
::= { cpqSiSystemBoard 5 }
cpqSiMemModuleEntry OBJECT-TYPE
SYNTAX CpqSiMemModuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A memory module description."
INDEX { cpqSiMemBoardIndex , cpqSiMemModuleIndex }
::= { cpqSiMemModuleTable 1 }
CpqSiMemModuleEntry ::= SEQUENCE {
cpqSiMemBoardIndex INTEGER,
cpqSiMemModuleIndex INTEGER,
cpqSiMemModuleSize INTEGER,
cpqSiMemModuleType INTEGER,
cpqSiMemModuleSpeed INTEGER,
cpqSiMemModuleTechnology INTEGER,
cpqSiMemModuleManufacturer DisplayString,
cpqSiMemModulePartNo DisplayString,
cpqSiMemModuleDate OCTET STRING,
cpqSiMemModuleSerialNo DisplayString,
cpqSiMemModuleECCStatus INTEGER,
cpqSiMemModuleHwLocation DisplayString
}
cpqSiMemBoardIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot in which the memory board is installed."
::= { cpqSiMemModuleEntry 1 }
cpqSiMemModuleIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The memory module number."
::= { cpqSiMemModuleEntry 2 }
cpqSiMemModuleSize OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module memory size in kilobytes. A kilobyte of memory is
defined as 1024 bytes."
::= { cpqSiMemModuleEntry 3 }
cpqSiMemModuleType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
board(2),
cpqSingleWidthModule(3),
cpqDoubleWidthModule(4),
simm(5),
pcmcia(6),
compaq-specific(7),
dimm(8),
smallOutlineDimm(9),
rimm(10),
srimm(11)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of memory module installed. The value other(1) will be
given if the type is not known. The value board(2) will be
given if the memory module is permanently mounted (not modular)
on a system board or memory expansion board."
::= { cpqSiMemModuleEntry 4 }
cpqSiMemModuleSpeed OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module memory speed in nanoseconds. The value zero (0) will
be given if the module speed cannot be determined."
::= { cpqSiMemModuleEntry 5 }
cpqSiMemModuleTechnology OBJECT-TYPE
SYNTAX INTEGER {
other(1),
fastPageMode(2),
edoPageMode(3),
burstEdoPageMode(4),
synchronous(5),
rdram(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Technology type of memory module installed. The value other(1)
will be given if the technology is not known."
::= { cpqSiMemModuleEntry 6 }
cpqSiMemModuleManufacturer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The memory module's manufacturer name.
This field will be a null (size 0) string if the manufacturer
name is not available."
::= { cpqSiMemModuleEntry 7 }
cpqSiMemModulePartNo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The memory module's manufacturer part number.
This field will be a null (size 0) string if the manufacturer
part number is not available."
::= { cpqSiMemModuleEntry 8 }
cpqSiMemModuleDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The memory module date of manufacture.
field octets contents range
===== ====== ====================== ========
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the date of manufacture
is not available. The hour, minute, and second field will
always be set to 0."
::= { cpqSiMemModuleEntry 9 }
cpqSiMemModuleSerialNo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The memory module's serial number.
This field will be a null (size 0) string if the serial number
is not available."
::= { cpqSiMemModuleEntry 10 }
cpqSiMemModuleECCStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3),
degradedModuleIndexUnknown(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This provides the current status of the correctable memory
errors for this memory module.
The following status values are supported:
other(1):
ECC is not supported on this memory module.
ok(2):
The correctable error count is below threshold.
degraded(3):
The correctable error count has exceeded threshold.
degradedModuleIndexUnknown(4):
The correctable error count has exceeded threshold.
The module index not available."
-- :CPQ,DEV:
-- This implementation of ECC is for Desktop systems.
--
-- If the memory modules do not support module indexing for ECC errors,
-- then all similar memory modules should be set to
-- "degradedModuleIndexUnknown" when any one of these modules
-- become degraded.
-- :CPQ,ENDDEV:
::= { cpqSiMemModuleEntry 11 }
cpqSiMemModuleHwLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS optional
DESCRIPTION
"A text description of the hardware location, on complex
multi SBB hardware only, for the memory module.
A NULL string indicates that the hardware location could not
be determined or is irrelevant."
::= { cpqSiMemModuleEntry 12 }
-- ****************************************************************************
-- Compaq System Information System Board Group
-- ============================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiSystemBoard Group (1.3.6.1.4.1.232.2.2.4)
--
--
-- ****************************************************************************
cpqSiSystemId OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Compaq System ID.
This value indicates the Compaq system ID of the system board
in this system. This ID replaces the product ID used in
older machines (cpqSiProductId). A value of 7Eh for the
cpqSiProductId indicates that the cpqSiSystemId should be
used to identify the Compaq system. A value of zero (0)
indicates that the system ID function is not supported on this
machine. In this case, the cpqSiProductId should be used to
identify the system."
::= { cpqSiSystemBoard 6 }
cpqSiSystemCpuId OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Compaq System ID : CPU Component.
This value indicates the CPU type of the system board
in this system. A value of zero (0) indicates that the CPU
type cannot be determined."
::= { cpqSiSystemBoard 7 }
cpqSiFlashRomSupport OBJECT-TYPE
SYNTAX INTEGER {
other(1),
notSupported(2),
supported(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if this system supports flash upgradable
system ROM."
::= { cpqSiSystemBoard 8 }
cpqSiQuickTestRomDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the date of the current quick test ROM
image.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if quick test ROM is not
present. The hour, minute, and second field will be set
to zero (0) if they are not relevant. The year field is set
with the most significant octect first."
::= { cpqSiSystemBoard 9 }
cpqSiReboot OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(1),
available(2),
defaultOnlyAvailable(3),
rebootToCpqUtils(2693),
rebootToDefault(8115),
autoShutdown(9037)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object may contain the following values:
notAvailable(1)
the system does not support the reboot functionality.
Setting this object to notAvailable(1) has no effect.
available(2)
the system supports the both reboot to functionalities.
Setting this object to available(2) has no effect.
defaultOnlyAvailable(3)
the system supports the only the default reboot functionality.
Setting this object to available(3) has no effect.
rebootToCpqUtils(2693)
the system will reboot to the Compaq Utilities if
the reboot functionality is available. If possible,
the agent will attempt to gracefully shutdown the
operating system before performing the reboot.
If this functionality is unavailable on this system
then all sets will have no effect.
rebootToDefault(8115)
the system will reboot and allow the default boot
process to occur if the reboot functionality is
available. If possible, the agent will attempt to
gracefully shutdown the operating system before
performing the reboot. If this functionality is
unavailable on this system then all sets will have
no effect.
autoShutdown(9037)
If possible, the agent will attempt to gracefully
shutdown the operating system. The agent will not
preform a reboot.
"
-- :CPQ,DEV:
--
-- defaultOnlyAvailable implies that the system partition is not present, or
-- cannot be rebooted to (for some reason.) The OS should determine this
-- status to the best of its ability.
--
-- Available or unavailable is intended to reflect whether this operation can
-- be performed by the management station getting this information at this
-- moment, as best the agent can determine this information. This should
-- take into account whether the machine supports this function and any agent
-- configuration parameters.
--
-- If reboot to Compaq utilities is selected the one-time boot EV should
-- be set for this action and then the CSM power cycle should be
-- performed.
-- If reboot to default is selected the CSM power cycle should be
-- performed.
-- A strategy for a consistent way to perform a graceful downing of the
-- server is to be determined.
-- :CPQ,ENDDEV:
::= { cpqSiSystemBoard 10 }
-- ****************************************************************************
-- Compaq System Information Processor Microcode Patch Table
-- =========================================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiSystemBoard Group (1.3.6.1.4.1.232.2.2.4)
-- cpqSiProcMicroPatchTable (1.3.6.1.4.1.232.2.2.4.11)
-- cpqSiProcMicroPatchEntry (1.3.6.1.4.1.232.2.2.4.11.1)
--
-- ****************************************************************************
cpqSiProcMicroPatchTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSiProcMicroPatchEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table lists the set of processor microcode patches that
the system ROM contains. During post, the ROM will apply the
appropriate patches to the CPU microcode. Scan this table to
ensure that a patch is being applied to a processor."
::= { cpqSiSystemBoard 11 }
cpqSiProcMicroPatchEntry OBJECT-TYPE
SYNTAX CpqSiProcMicroPatchEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry describing one microcode patch contained in the system
ROM."
INDEX { cpqSiProcMicroPatchIndex }
::= { cpqSiProcMicroPatchTable 1 }
CpqSiProcMicroPatchEntry ::= SEQUENCE {
cpqSiProcMicroPatchIndex INTEGER,
cpqSiProcMicroPatchId INTEGER,
cpqSiProcMicroPatchDate OCTET STRING,
cpqSiProcMicroPatchFamily OCTET STRING }
cpqSiProcMicroPatchIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index into the microcode patch table."
::= { cpqSiProcMicroPatchEntry 1 }
cpqSiProcMicroPatchId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ID of this particular CPU microcode patch."
::= { cpqSiProcMicroPatchEntry 2 }
cpqSiProcMicroPatchDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the date of this CPU microcode patch.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
NOTE: Year is stored in packed BCD. The most significant
part is in the second octet. For example:
1995 would be stored as 0x95 0x19.
The hour, minute, and second field will be set to zero (0)
if they are not relevant. The year field is set with the
most significant octet first."
::= { cpqSiProcMicroPatchEntry 3 }
cpqSiProcMicroPatchFamily OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (3))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The valid family/model/step of the processor that this CPU
microcode patch applies to.
field octets contents range
===== ====== ======= =====
1 1 CPU Step 0..255
2 2 CPU Model 0..255
3 3 CPU Family 0..255 "
::= { cpqSiProcMicroPatchEntry 4 }
-- ****************************************************************************
-- Compaq System Information System Board Group
-- ============================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiSystemBoard Group (1.3.6.1.4.1.232.2.2.4)
--
--
-- ****************************************************************************
cpqSiPowerMgmtStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of power management."
::= { cpqSiSystemBoard 12 }
cpqSiRebootFlags OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Reboot Flags.
This is a collection of flags used to indicate the re-boot
options available. This integer is a bitmap, with each bit
indicating the availability of an option. If the bit is set
to 1, the option is available; otherwise it is not. Multiple
options are allowed.
NOTE: bit 31 is the most significant bit, bit 0 is the least
significant.
Status This is a collection of flags. Each bit has the
following meaning when it is on (1):
Bit 31: Execute Set
Bit 30-4: RESERVED
Bit 3: Boot to OS
Bit 2: Boot to Utils
Bit 1: Warm Boot
Bit 0: Cold Boot
"
-- :CPQ,DEV:
-- Bit 31 is reserved for the Insight Manager console during a set
-- operation. When this bit is set to 1, the agent is to perform the
-- reboot operation designated by the combination of bits defined below:
--
-- 0x80000010 -> UPS multi-server shutdown functionality
--
-- 0x8000000A -> Warm boot back to OS
-- 0x80000009 -> Cold boot back to OS
-- 0x80000006 -> Warm boot to Utils
-- 0x80000005 -> Cold boot to Utils
--
-- This item deprecates cpqSiReboot. The enumerations for cpqSiReboot map
-- to the following bit settings:
--
-- notAvailable 0x00000000
-- available 0x0000001F
-- defaultOnlyAvailable 0x0000001B
-- rebootToCpqUtils 0x80000006
-- rebootToDefault 0x8000000A
--
-- Cold boot requires a power cycle via a hardware mechanism like CSM or OSB.
-- Reboot to Utils requires a set to the one-time boot EV.
--
-- UPS multi-server shutdown support:
-- Bit 4 is used for UPS multi-server shutdown functionality. Agents should
-- not report this bit on get operations. If a set is received with this bit set,
-- agent software should process as UPS multi-server shutdown.
-- :CPQ,ENDDEV:
::= { cpqSiSystemBoard 13 }
cpqSiMemErrorIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Placeholder for memory module number for ECC traps.
Represents the number of the memory module for which an ECC status
change has occured. Set to 65535 if module number not available."
-- :CPQ,DEV:
-- This is currently only being implemented in Desktop agents. The current
-- definition assumes all memory is on a single memory board. For the server
-- agents to use this in the future, the index definition will probably have to
-- change to just INTEGER with the memory board index in the upper two bytes.
-- :CPQ,ENDDEV:
::= { cpqSiSystemBoard 14 }
cpqSiMemECCCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This provides the current condition of the correctable memory
errors for the entire memory.
The following status values are supported:
other(1) :
ECC is not supported.
ok(2) :
The correctable error count is below threshold.
degraded(3) :
The correctable error count has exceeded threshold."
::= { cpqSiSystemBoard 15 }
cpqSiMemConfigChangeData OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..383))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Text string for the memory configuration change trap."
-- :CPQ,DEV:
-- Desktop agents string format:
-- The trap message should be built based on the
-- memory modules that have changed. The following message
-- template should be used. This template has been calculated to
-- not exceed 380 bytes for worst case condition of all 8 modules
-- changing. Note that SIMM machines have 4 or 8 slots and
-- DIMM machines have 3 slots.
--
-- Message Template:
-- "Memory configuration change. The following has changed:<cr-lf>
-- Prev:<cr-lf>
-- <module_val>: <size_val> MB, <speed_val> ns, S/N <s/n_val><cr-lf>
-- Curr:<cr-lf>
-- <module_val>: <size_val> MB, <speed_val> ns, S/N <s/n_val><cr-lf>"
--
-- where:
-- <cr-lf> = (0x0D 0x0A)
-- <module_val> = 1..8
-- <size_val> = 0..9999
-- <speed_val> = 0..999
-- <s/n_val> = xxxxxxxx, if no s/n is available then do not display
--
-- Some possible examples are shown below:
--
-- "Memory configuration change. The following has changed:
-- Prev:
-- 1: 8 MB, 72 ns
-- 2: 8 MB, 72 ns
-- 3: 8 MB, 72 ns
-- 4: 8 MB, 72 ns
-- Curr:
-- 1: 4 MB, 72 ns
-- 2: 4 MB, 72 ns
-- 3: empty
-- 4: empty"
--
-- or
--
-- "Memory configuration change. The following has changed:
-- Prev:
-- 3: 16 MB, 72 ns, S/N XYZ123AB
-- Curr:
-- 3: empty"
--
-- :CPQ,ENDDEV:
::= { cpqSiSystemBoard 16 }
cpqSiServerSystemId OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A Server System ID.
This value is used to uniquely identify systems via a unique
ID on systems that do not support the EISA bus."
-- :CPQ,DEV:
-- This corresponds to the EISA id of SLOT 0 in systems which still
-- use System Config.
-- On SOS systems, this id is embedded in the option ROM space and
-- can be found by searching for '$', 0x0E, 0x11.
-- On newer SMBIOS systems use record 195 for the Server System ID.
-- :CPQ,ENDDEV:
::= { cpqSiSystemBoard 17 }
-- ****************************************************************************
-- Compaq System Information Board Revision Group
-- ==============================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiBoardRev Group (1.3.6.1.4.1.232.2.2.5)
--
-- The cpqSiBoardRev group describes the board revision information.
--
-- Implementation of the cpqSiBoardRev group is mandatory for all
-- agents that support the Compaq System Information MIB in a system that
-- supports the board revision feature.
--
-- ****************************************************************************
cpqSiCurRevDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current board revision configuration date in MM/DD/YY
format. This is the date that the EISA Configuration Utility
was used to define the current configuration. This value will
contain 'N/A' if this system does not support this feature."
::= { cpqSiBoardRev 1 }
cpqSiPrevRevDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The previous board revision configuration date in MM/DD/YY
format. This is the date that the EISA Configuration Utility
was used to define the previous configuration. This value will
contain 'N/A' if this system does not support this feature."
::= { cpqSiBoardRev 2 }
-- ****************************************************************************
-- Compaq System Information Board Revision Table
-- ==============================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiBoardRev Group (1.3.6.1.4.1.232.2.2.5)
-- cpqSiBoardRevTable (1.3.6.1.4.1.232.2.2.5.3)
--
-- ****************************************************************************
cpqSiBoardRevTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSiBoardRevEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of board revision descriptions."
::= { cpqSiBoardRev 3 }
cpqSiBoardRevEntry OBJECT-TYPE
SYNTAX CpqSiBoardRevEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A board revision description."
INDEX { cpqSiBoardRevSlotIndex, cpqSiBoardRevIndex }
::= { cpqSiBoardRevTable 1 }
CpqSiBoardRevEntry ::= SEQUENCE {
cpqSiBoardRevSlotIndex INTEGER,
cpqSiBoardRevIndex INTEGER,
cpqSiBoardRevId DisplayString,
cpqSiBoardRevCur DisplayString,
cpqSiBoardRevPrev DisplayString,
cpqSiBoardRevHwLocation DisplayString
}
cpqSiBoardRevSlotIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot in which the board described in this entry resides.
Zero (0) indicates the system board."
::= { cpqSiBoardRevEntry 1 }
cpqSiBoardRevIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A number that uniquely specifies which board in a specific slot
is described in this entry. Zero (0) indicates the main board
in this slot. Any other number indicates a daughter board or a
component of the main board."
::= { cpqSiBoardRevEntry 2 }
cpqSiBoardRevId OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A description of the board type. The defined types are:
Type
==============
System Board
Processor n (n = the processor number)
Memory n (n = the memory board number)
Slot n (n = the slot the board occupies)
Other types may be defined at a later date."
::= { cpqSiBoardRevEntry 3 }
cpqSiBoardRevCur OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current revision for the board described in this entry.
This value will be N/A if there is no current revision
information."
-- :CPQ,DEV:
-- The format for this field is 'AB ver:x' where AB is the
-- Board revision and x is the assembly version.
-- Obtain this information from EISA Type string in NVRAM.
-- It is updated by CF. See the latest Wellness spec.
-- System ROM issues will generate an F1 msg when a board is replaced
-- (not the same revision). Then CF will update NVRAM.
-- :CPQ,ENDDEV:
::= { cpqSiBoardRevEntry 4 }
cpqSiBoardRevPrev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The revision for the board described in this entry prior to the
current configuration. This value will be N/A if there is no
previous revision information."
-- :CPQ,DEV:
-- The format for this field is 'AB ver:x' where AB is the
-- Board revision and x is the assembly version.
-- Obtain this information from EISA Type string in NVRAM.
-- It is updated by CF. See the latest Wellness spec.
-- System ROM issues will generate an F1 msg when a board is replaced
-- (not the same revision). Then CF will update NVRAM.
-- :CPQ,ENDDEV:
::= { cpqSiBoardRevEntry 5 }
cpqSiBoardRevHwLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS optional
DESCRIPTION
"A text description of the hardware location, on complex
multi SBB hardware only, for the board.
A NULL string indicates that the hardware location could not
be determined or is irrelevant."
::= { cpqSiBoardRevEntry 6 }
-- ****************************************************************************
-- Compaq System Information Firmware Revision Table
-- =================================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiBoardRev Group (1.3.6.1.4.1.232.2.2.5)
-- cpqSiFirmwareRevTable (1.3.6.1.4.1.232.2.2.5.4)
--
-- ****************************************************************************
cpqSiFirmwareRevTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSiFirmwareRevEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of firmware revision descriptions."
::= { cpqSiBoardRev 4 }
cpqSiFirmwareRevEntry OBJECT-TYPE
SYNTAX CpqSiFirmwareRevEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A firmware revision description."
INDEX { cpqSiFirmwareRevIndex }
::= { cpqSiFirmwareRevTable 1 }
CpqSiFirmwareRevEntry ::= SEQUENCE {
cpqSiFirmwareRevIndex INTEGER,
cpqSiFirmwareRevDesc DisplayString,
cpqSiFirmwareRevString DisplayString
}
cpqSiFirmwareRevIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Locally-unique index for this entry."
::= { cpqSiFirmwareRevEntry 1 }
cpqSiFirmwareRevDesc OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Description, e.g. SRM console, ARC console, System BIOS, etc."
::= { cpqSiFirmwareRevEntry 2 }
cpqSiFirmwareRevString OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Version number, possibly of the form Vx.y or Vx.y-z."
::= { cpqSiFirmwareRevEntry 3 }
-- ****************************************************************************
-- Compaq System Information Firmware Configuration Table
-- ======================================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiBoardRev Group (1.3.6.1.4.1.232.2.2.5)
-- cpqSiFirmwareCfgTable (1.3.6.1.4.1.232.2.2.5.5)
--
-- ****************************************************************************
cpqSiFirmwareCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSiFirmwareCfgEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of soft switches and symbols maintained by the
firmware. May be operating system and/or option-specific
and will certainly be system-specific. This list is
intended to be easily extensible and support arbitrary
datatypes. It includes such switches as powerup options,
default dump device, etc.
Note - the string comparision for svrFwSymbolName is case
insensitive."
::= { cpqSiBoardRev 5 }
cpqSiFirmwareCfgEntry OBJECT-TYPE
SYNTAX CpqSiFirmwareCfgEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry represents one variable or symbol maintained by
or stored by some instance of firmware in the system."
INDEX { cpqSiFirmwareCfgName }
::= { cpqSiFirmwareCfgTable 1 }
CpqSiFirmwareCfgEntry ::= SEQUENCE {
cpqSiFirmwareCfgName DisplayString,
cpqSiFirmwareCfgValue DisplayString
}
cpqSiFirmwareCfgName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The firmware configuration symbol name as visible from the
console."
::= { cpqSiFirmwareCfgEntry 1 }
cpqSiFirmwareCfgValue OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The firmware configuration symbol value. Null if none
or unknown."
::= { cpqSiFirmwareCfgEntry 2 }
-- ****************************************************************************
-- Compaq System Information Ups Shutdown Group
-- ============================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiRackServer Group (1.3.6.1.4.1.232.2.2.6)
--
-- The cpqSiRackServer group describes this system's role in a rack
-- family.
--
-- Implementation of the cpqSiRackServer group is mandatory for all
-- agents that support the Compaq System Information MIB in a system that
-- supports Rack Server features.
--
-- ****************************************************************************
cpqSiRackServerShutdownRole OBJECT-TYPE
SYNTAX INTEGER {
other(1),
master(2),
slave(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This entry describes this system's role in a rack-mounted
uninterruptable power supply family. The master both
communicates with the UPS and derives its power from the
UPS. The slave derives its power from the UPS, but does
not communicate with it."
::= { cpqSiRackServer 1 }
cpqSiRackServerMasterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This entry describes the name of the master server in a
rack-mounted uninterruptable power supply family. A slave
system would communicate with this server to derive UPS
status."
::= { cpqSiRackServer 2 }
-- ****************************************************************************
-- Compaq System Information Video Group
-- =====================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiVideo Group (1.3.6.1.4.1.232.2.2.7)
--
-- The Video group describes the Compaq manageable video displays that is
-- attached to the system.
--
-- Implementation of the video group is mandatory for all agents that
-- support the Compaq System Information MIB when a Compaq manageable
-- video display is in the system.
--
-- ****************************************************************************
cpqSiVideoEdidRaw OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (128))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The raw value returned from the video EDID function."
::= { cpqSiVideo 1 }
cpqSiVideoDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The manufacturer and model description of the video display."
::= { cpqSiVideo 2 }
cpqSiVideoSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The serial number of the video display."
::= { cpqSiVideo 3 }
cpqSiVideoManufactureDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The date of manufacture of the video display in the following
format:
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the date. The date information that is given resolves to a year
and week, so the hour, minute, and second field will be set to 0,
the month and day fields will give the monday of the week of
manufacture."
::= { cpqSiVideo 4 }
cpqSiVideoHeight OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The maximum image height of the video display in centimeters"
::= { cpqSiVideo 5 }
cpqSiVideoWidth OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The maximum image width of the video display in centimeters"
::= { cpqSiVideo 6 }
cpqSiVideoMaxHorPixel OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of horizontal pixels in the highest resolution video
mode supported."
::= { cpqSiVideo 7 }
cpqSiVideoMaxVertPixel OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of vertical pixels in the highest resolution video
mode supported."
::= { cpqSiVideo 8 }
cpqSiVideoMaxRefreshRate OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The video refresh rate in Hz of the highest resolution video
mode supported."
::= { cpqSiVideo 9 }
-- ****************************************************************************
-- Compaq System Information Monitor Group
-- =======================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiMonitor Group (1.3.6.1.4.1.232.2.2.8)
--
-- The Monitor group describes all Compaq manageable video displays
-- that are attached to the system.
--
-- Implementation of the monitor group is mandatory for all agents that
-- support the Compaq System Information MIB when a Compaq manageable
-- video display is in the system.
--
-- ****************************************************************************
cpqSiMonitorOverallCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value specifies the overall condition of the system's
monitor(s).
The following conditions are supported:
other(1)
The monitor does not support fault reporting or condition is
unknown.
ok(2)
The monitor is operating OK.
degraded(3)
The monitor has detected a fault. The monitor is still useable
but action should be taken to return the monitor to ok.
failed(4)
The monitor has detected a fault. The monitor will not
be useable. Action should be taken to replace the monitor."
-- :CPQ,DEV:
-- The cpqSiMonitorOverallCondition is set as follows:
--
-- other(1): if all cpqSiMonitorThermalCondition and
-- cpqSiMonitorOperationalCondition are "other."
--
-- OK(2): If all cpqSiMonitorThermalCondition and
-- cpqSiMonitorOperationalCondition are "OK"
--
-- degraded(3): If either cpqSiMonitorThermalCondition or
-- any cpqSiMonitorOperationalCondition is "degraded"
-- and no cpqMonitorOperationalCondition is "failed"
--
-- failed(4): If any cpqMonitorOperationalCondition is "failed"
--
-- This designed is for single or multiple monitor support.
-- :CPQ,ENDDEV:
::= { cpqSiMonitor 1 }
-- ****************************************************************************
-- Compaq System Information Monitor Group
-- =======================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiMonitor Group (1.3.6.1.4.1.232.2.2.8)
-- cpqSiMonitorTable (1.3.6.1.4.1.232.2.2.8.2)
-- cpqSiMonitorEntry (1.3.6.1.4.1.232.2.2.8.2.1)
--
-- The Monitor Table describes all Compaq manageable video displays
-- that are attached to the system.
--
-- ****************************************************************************
cpqSiMonitorTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSiMonitorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of all video monitor descriptions connected to this
system."
::= { cpqSiMonitor 2 }
cpqSiMonitorEntry OBJECT-TYPE
SYNTAX CpqSiMonitorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A video monitor description."
INDEX { cpqSiMonitorIndex }
::= { cpqSiMonitorTable 1 }
CpqSiMonitorEntry ::= SEQUENCE {
cpqSiMonitorIndex INTEGER,
cpqSiMonitorEdidRaw OCTET STRING,
cpqSiMonitorDesc DisplayString,
cpqSiMonitorSerialNumber DisplayString,
cpqSiMonitorManufactureDate OCTET STRING,
cpqSiMonitorHeight INTEGER,
cpqSiMonitorWidth INTEGER,
cpqSiMonitorMaxHorPixel INTEGER,
cpqSiMonitorMaxVertPixel INTEGER,
cpqSiMonitorMaxRefreshRate INTEGER,
cpqSiMonitorManufacturer DisplayString,
cpqSiMonitorThermalCondition INTEGER,
cpqSiMonitorOperationalCondition INTEGER,
cpqSiMonitorStatus INTEGER
}
cpqSiMonitorIndex OBJECT-TYPE
SYNTAX INTEGER (0..15)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique index for each video display connected to the system."
-- :CPQ,DEV:
-- If there is only one monitor in the system, then cppSiMonitorIndex should
-- equal zero (0).
-- :CPQ,ENDDEV:
::= { cpqSiMonitorEntry 1 }
cpqSiMonitorEdidRaw OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The raw value returned from the video EDID function."
::= { cpqSiMonitorEntry 2 }
cpqSiMonitorDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The manufacturer and model description of the video display."
::= { cpqSiMonitorEntry 3 }
cpqSiMonitorSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial number of the video display."
::= { cpqSiMonitorEntry 4 }
cpqSiMonitorManufactureDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date of manufacture of the video display in the following
format:
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the date. The date information that is given resolves to a year
and week, so the hour, minute, and second field will be set to 0,
the month and day fields will give the monday of the week of
manufacture."
::= { cpqSiMonitorEntry 5 }
cpqSiMonitorHeight OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum image height of the video display in centimeters"
::= { cpqSiMonitorEntry 6}
cpqSiMonitorWidth OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum image width of the video display in centimeters"
::= { cpqSiMonitorEntry 7 }
cpqSiMonitorMaxHorPixel OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of horizontal pixels in the highest resolution video
mode supported."
::= { cpqSiMonitorEntry 8 }
cpqSiMonitorMaxVertPixel OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of vertical pixels in the highest resolution video mode
supported."
::= { cpqSiMonitorEntry 9 }
cpqSiMonitorMaxRefreshRate OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The video refresh rate in Hz of the highest resolution video mode
supported."
::= { cpqSiMonitorEntry 10 }
cpqSiMonitorManufacturer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The manufacturer of the video display."
::= { cpqSiMonitorEntry 11 }
cpqSiMonitorThermalCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This provides the condition of the monitor<6F>s internal temperature.
This value will be one of the following:
other(1)
Monitor thermal fault reporting is not supported by this monitor
or the Insight Agent does not recognize the status. You may
need to upgrade your software.
ok(2)
The internal temperature is within normal limits.
degraded(3)
The internal temperature is outside normal operating range."
::= { cpqSiMonitorEntry 12 }
cpqSiMonitorOperationalCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This provides the condition of the monitor's operational features.
This condition value will be one of the following:
other(1)
Monitor operational fault reporting is not supported by this
monitor or the Insight Agent does not recognize the status.
You may need to upgrade your software.
ok(2)
The monitor is operating within normal limits.
degraded(3)
The monitor is not functioning within normal operating limits.
At least one of the opertional features has become degraded.
failed(4)
The monitor is not functioning within normal operating limits.
At least one of the operational features has failed causing the
monitor to not be usable. The monitor should be replaced."
::= { cpqSiMonitorEntry 13 }
cpqSiMonitorStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
ok(3),
thermalDegraded(4),
operationalFailure(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This provides the status of the monitor's fault reporting features.
This status value will be one of the following:
other(1)
Monitor fault reporting is not supported by this monitor or the
Insight Agent does not recognize the status. You may need to
upgrade your software.
unknown(2)
The monitor status is unknown because the monitor is
either in power saving mode or it has been turned off.
ok(3)
The monitor is operating within normal limits.
thermalDegraded(4)
The monitor's internal temperature is not functioning within
normal operating limits.
operationalFailure(5)
The monitor is not functioning within normal operating limits.
At least one of the operational features has failed.
The monitor should be replaced."
-- :CPQ,DEV:
-- The current list of Monitor fault reporting features that should be
-- supported by the Insight Agent is shown below:
-- States
-- Fault Reporting Features OK Degraded Failed Unknown
-- =========================================== === ======== ====== =======
-- Internal Temperature outside normal range yes yes no yes
-- Power supply voltage outside normal range yes no yes yes
-- Power supply current outside normal range yes no yes yes
-- Horizontial deflection outside normal range yes no yes yes
-- Vertical deflection outside normal range yes no yes yes
-- I/O controller not responding. yes no yes yes
--
-- :CPQ,ENDDEV:
::= { cpqSiMonitorEntry 14 }
-- ****************************************************************************
-- System Information Hot Plug Slot Group
-- ======================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiHotPlugSlot Group (1.3.6.1.4.1.232.2.2.9)
--
-- The cpqSiHotPlugSlot group describes the System Information Hot Plug
-- slot information.
--
-- Implementation of the cpqSiHotPlugSlot group is mandatory for all
-- agents that support the Compaq System Information MIB.
--
-- ****************************************************************************
cpqSiHotPlugSlotSupported OBJECT-TYPE
SYNTAX INTEGER {
other(1),
notSupported(2),
supported(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value specifies if this system supports the Hot
Pluggable Slot feature."
::= { cpqSiHotPlugSlot 1 }
cpqSiHotPlugSlotCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value specifies the overall condition of the Hot Plug
Slot feature.
The Hot Plug condition is set as follows:
other(1)
When Hot Plug Slots are not supported or condition is unknown.
ok(2)
If there are no hot plug slots with a condition of degraded
or failed.
degraded(3)
If there are degraded slot entries but none failed.
failed(4)
If there are failed slot entries."
-- :CPQ,DEV:
--
-- cpqSiMibCondition needs to be updated to reflect the value of
-- this MIB.
--
-- Compaq Insigh Manager displays colored border around
-- Expansion Board button based on the value of this MIB.
--
-- :CPQ,ENDDEV:
::= { cpqSiHotPlugSlot 2 }
cpqSiHotPlugSlotChangeCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value will be incremented each time a hot plug event
occurs resulting in a change in the hot plug slot table."
::= { cpqSiHotPlugSlot 3 }
-- ****************************************************************************
-- System Information Hot Plug Slot Table
-- ======================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiHotPlugSlot Group (1.3.6.1.4.1.232.2.2.9)
-- cpqSiHotPlugSlotTable (1.3.6.1.4.1.232.2.2.9.4)
--
-- The cpqSiHotPlugSlot group describes the Compaq manageable Hot Plug
-- Slots in the system. This table will be missing if the system does
-- not support hot plug slots.
--
-- ****************************************************************************
cpqSiHotPlugSlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSiHotPlugSlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of Hot Plug Slot information entries."
::= { cpqSiHotPlugSlot 4 }
cpqSiHotPlugSlotEntry OBJECT-TYPE
SYNTAX CpqSiHotPlugSlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of a Hot Plug Slot."
INDEX { cpqSiHotPlugSlotChassis, cpqSiHotPlugSlotIndex }
::= { cpqSiHotPlugSlotTable 1 }
CpqSiHotPlugSlotEntry ::= SEQUENCE {
cpqSiHotPlugSlotChassis INTEGER,
cpqSiHotPlugSlotIndex INTEGER,
cpqSiHotPlugSlotBoardPresent INTEGER,
cpqSiHotPlugSlotPowerState INTEGER,
cpqSiHotPlugSlotBoardCondition INTEGER,
cpqSiHotPlugSlotErrorStatus INTEGER,
cpqSiHotPlugSlotHwLocation DisplayString
}
cpqSiHotPlugSlotChassis OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Chassis where this hot plug slot resides."
::= { cpqSiHotPlugSlotEntry 1 }
cpqSiHotPlugSlotIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the chassis for this hot plug slot."
::= { cpqSiHotPlugSlotEntry 2 }
cpqSiHotPlugSlotBoardPresent OBJECT-TYPE
SYNTAX INTEGER {
other(1),
present(2),
absent(3),
presentButSuspended(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates whether a board is present(2) in or
absent(3) from the slot. A value of other(1) indicates
the information could not be obtained."
-- :CPQ,DEV:
--
-- Only UnixWare 7 (Gemini) implements "presentbutsuspended" starting
-- at Koala (3.70) release.
--
-- :CPQ,ENDDEV:
::= { cpqSiHotPlugSlotEntry 3 }
cpqSiHotPlugSlotPowerState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
powerOn(2),
powerOff(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value is set to powerOn(2) when power is being supplied
to the slot and powerOff(3) when power is not being supplied.
A value of other(1) indicates the information could not be
obtained."
::= { cpqSiHotPlugSlotEntry 4 }
cpqSiHotPlugSlotBoardCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value specifies the condition of the hot plug slot.
The hot plug condition is set as follows:
other(1)
When the condition could not be determined.
ok(2)
The slot is powered up and operating normally.
degraded(3)
If the board in the slot is not fully functioning.
failed(4)
If the slot is failed for any reason. See the status code
for more information on the failure."
-- :CPQ,DEV:
--
-- This MIB is set to degraded (3) only when one of the following conditions
-- is true:
-- 1. cpqSiHotPlugSlotBoardPresent is present (2) AND
-- cpqSiHotPlugSlotPowerState is poweroff (3).
-- 2. cpqSiHotPlugSlotBoardPresent is presentbutsuspended (4).
--
-- :CPQ,ENDDEV:
::= { cpqSiHotPlugSlotEntry 5 }
cpqSiHotPlugSlotErrorStatus OBJECT-TYPE
SYNTAX INTEGER {
noError(1),
generalError(2),
wrongRevision(3),
wrongBoard(4),
cannotConfig(5),
powerFault(6),
unexpectedPowerLoss(7),
wrongSpeed(8),
functionalFailure(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value specifies the status of the hot plug slot.
The hot plug slot status is set as follows:
noError(1)
The slot is operating normally.
generalError(2)
A general error occurred.
wrongRevision(3)
The revision of the replacement adapter was different from
the original adapter.
wrongBoard(4)
The model of the replacement adapter was different from the
original adapter.
cannotConfig(5)
The adapter could not be configured.
powerFault(6)
A power fault occurred for the slot.
unexpectedPowerLoss(7)
Power was unexpectedly lost from the slot.
wrongSpeed(8)
The adapter cannot be run at the current bus speed.
functionlFailure(9)
The adapter is not functioning correctly. This may
be caused by a cabling problem."
::= { cpqSiHotPlugSlotEntry 6 }
cpqSiHotPlugSlotHwLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS optional
DESCRIPTION
"A text description of the hardware location, on complex
multi SBB hardware only, for the hot plug slot.
A NULL string indicates that the hardware location could not
be determined or is irrelevant."
::= { cpqSiHotPlugSlotEntry 7 }
-- ****************************************************************************
-- System Information System Battery Group
-- =======================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiSystemBattery Group (1.3.6.1.4.1.232.2.2.10)
--
-- The cpqSiSystemBattery group describes information about the system
-- (protable) batteries that are used to power your system. These
-- are the rechargeable batteries.
--
--
-- Implementation of the cpqSiBattery group is mandatory for all
-- agents that support the Compaq System Information MIB.
--
-- ****************************************************************************
cpqSiSystemBatteryOverallCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value specifies the overall condition of all of the
system batteries.
The following conditions are supported:
other(1)
The system does not use system batteries or the battery
condition is unknown.
ok(2)
All System Batteries are operating OK.
degraded(3)
One or more of the System Batteries has degraded. The
degraded battery will continue to function but should be
replaced.
failed(4)
One of more of the System Batteries has failed. The failed
battery is no longer usable. Action should be taken to replace
the battery."
-- :CPQ,DEV:
-- The cpqSiSystemBatteryOverallCondition is set as follows:
--
-- other(1): If all cpqSiSysBatteryCondition equal unknown
--
-- ok(2): If all cpqSiSysBatteryCondition and ok.
--
-- degraded(3): If any cpqSiSysBatteryCondition equal to degraded
-- but not eqaul to failed
--
-- failed(4): If any cpqSiSysBatteryCondition equal to
-- failed.
--
-- :CPQ,ENDDEV:
::= { cpqSiSystemBattery 1 }
-- ****************************************************************************
-- System Information System Battery Group
-- =======================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiSystemBattery Group (1.3.6.1.4.1.232.2.2.10)
-- cpqSiSystemBatteryTable (1.3.6.1.4.1.232.2.2.10.2)
-- cpqSiSystemBatteryEntry (1.3.6.1.4.1.232.2.2.10.2.1)
--
-- The System Battery Table describes asset, physical, and status
-- information about the portable batteries powering your system.
--
-- ****************************************************************************
cpqSiSysBatteryTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSiSysBatteryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of System Batteries."
::= { cpqSiSystemBattery 2 }
cpqSiSysBatteryEntry OBJECT-TYPE
SYNTAX CpqSiSysBatteryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A system battery description."
INDEX { cpqSiSysBatteryIndex }
::= { cpqSiSysBatteryTable 1 }
CpqSiSysBatteryEntry ::= SEQUENCE {
cpqSiSysBatteryIndex INTEGER,
cpqSiSysBatteryModel DisplayString,
cpqSiSysBatterySerialNum DisplayString,
cpqSiSysBatteryAssetTag DisplayString,
cpqSiSysBatteryManufacturer DisplayString,
cpqSiSysBatteryDate OCTET STRING,
cpqSiSysBatterySmartVersion DisplayString,
cpqSiSysBatteryCondition INTEGER,
cpqSiSysBatteryStatus INTEGER,
cpqSiSysBatteryChemistry INTEGER,
cpqSiSysBatteryRemainingCap INTEGER,
cpqSiSysBatteryFirmwareRevision INTEGER,
cpqSiSysBatteryHardwareRevision INTEGER,
cpqSiSysBatteryFullCap INTEGER,
cpqSiSysBatteryDesignCap INTEGER,
cpqSiSysBatteryHwLocation DisplayString
}
cpqSiSysBatteryIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique index for this battery entry."
::= { cpqSiSysBatteryEntry 1 }
cpqSiSysBatteryModel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The model name for this battery."
::= { cpqSiSysBatteryEntry 2 }
cpqSiSysBatterySerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial number for this battery."
::= { cpqSiSysBatteryEntry 3 }
cpqSiSysBatteryAssetTag OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the customer changeable battery identifier that is set
to this system battery's serial number at the time of
manufacture.
The string will be empty if the battery does support
this function."
::= { cpqSiSysBatteryEntry 4 }
cpqSiSysBatteryManufacturer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The battery's manufacturer's name.
The string will be empty if the battery does support
this function."
::= { cpqSiSysBatteryEntry 5 }
cpqSiSysBatteryDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The battery's manufacture date.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the module date. The hour, minute, and second field will be set
to zero (0) if they are not relevant. The year field is set
with the most significant octect first.
The string will be empty if the battery does support
this function."
::= { cpqSiSysBatteryEntry 6 }
cpqSiSysBatterySmartVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Smart Battery Data Specification version number supported by this
battery.
The string will be empty if the system battery does support
this function."
::= { cpqSiSysBatteryEntry 7 }
cpqSiSysBatteryCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This provides the current condition of this system battery.
The following status values are supported:
other(1)
The battery does not support condition monitoring or
the Insight Agent cannot determine condition.
ok(2)
The battery is operating normally. No user action is
required.
degraded(3)
The battery is degraded. The battery is still usable
but should be replaced.
failed(4)
The battery has failed. The battery is no longer
usable and should be replaced soon."
::= { cpqSiSysBatteryEntry 8 }
cpqSiSysBatteryStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
capacityDegraded(3),
chargeFault(4),
batteryFailure(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This provides the current status of the battery.
The following status values are supported:
other(1):
This battery does not support status reporting.
ok(2):
The battery is operating ok.
User Action: No action required.
capacityDegraded(3):
Significant battery degradation has occurred.
The battery can no longer be fully recharged.
User Action:
If using multiple batteries, run Compaq Power
Conservation Utility to identify the battery
location. Contact your System Administrator or
Compaq Authorized Reseller to order a replacement
battery.
chargeFault(4):
One or more batteries are not functioning properly.
User Action:
Make sure all batteries are operating in the
recommended temperature range. Check for foreign
objects in the battery slots. Remove and reinsert all
batteries to resume normal battery operation.
Contact your System Administrator or Compaq Authorized
Reseller if you are still experiencing problems.
batteryFailure(5):
The battery has failed and must be replaced.
User Action:
Contact your System Administrator or Compaq Authorized
Reseller to order a replacement battery. Recycle your
old battery. For proper disposal information, refer
to the documentation that came with your computer."
::= { cpqSiSysBatteryEntry 9 }
cpqSiSysBatteryChemistry OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
lead-Acid(3),
nickel-Cadmium(4),
nickel-Metal-Hydride(5),
lithium-Ion(6),
zinc-Air(7),
lithium-Polymer(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The chemistry of the battery."
::= { cpqSiSysBatteryEntry 10 }
cpqSiSysBatteryRemainingCap OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a percentage of the battery's remaining capacity
from its design capacity.
If this attribute is not supported, 65535 is returned."
::= { cpqSiSysBatteryEntry 11 }
cpqSiSysBatteryFirmwareRevision OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the revision level of the firmware on the battery.
If this attribute is not supported, 255 is returned."
::= { cpqSiSysBatteryEntry 12 }
cpqSiSysBatteryHardwareRevision OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the revision level of the hardware on the battery.
If this attribute is not supported, 255 is returned."
::= { cpqSiSysBatteryEntry 13 }
cpqSiSysBatteryFullCap OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the mWatt-Hours of the battery's Full capacity on
the current charge.
If this attribute is not supported, 65535 is returned."
::= { cpqSiSysBatteryEntry 14 }
cpqSiSysBatteryDesignCap OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the mWatt-Hours of the battery's design capacity as
specified by the manufacturer.
If this attribute is not supported, 65535 is returned."
::= { cpqSiSysBatteryEntry 15 }
cpqSiSysBatteryHwLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS optional
DESCRIPTION
"A text description of the hardware location, on complex
multi SBB hardware only, for the battery.
A NULL string indicates that the hardware location could not
be determined or is irrelevant."
::= { cpqSiSysBatteryEntry 16 }
-- ****************************************************************************
-- System Information Docking Station Group
-- ========================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiDockingStation Group (1.3.6.1.4.1.232.2.2.11)
--
-- The cpqsiDockingStation group describes the asset information
-- about portable docking stations.
--
--
-- Implementation of the cpqSiDockingStation group is mandatory for all
-- agents that support the Compaq System Information MIB.
--
-- ****************************************************************************
cpqSiDockingStationStatus OBJECT-TYPE
SYNTAX INTEGER {
notSupported(1),
docked(2),
undocked(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value specifies the connection of the computer
system to a docking station.
The following connection states are supported:
notSupported(1)
This system does not interface to a docking station.
docked(2)
This system is connected to a docking station.
undocked(3)
This system is not connect to a docking station."
::= { cpqSiDockingStation 1}
cpqSiDockingStationSerialNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial number of the docking station.
The string will be empty if the docking station does not support a
serial or the system does not interface to a docking station."
::= { cpqSiDockingStation 2 }
cpqSiDockingStationModel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The model name of the docking station.
The string will be empty if the docking station does not report the
model name or the system does not interface to a docking station."
::= { cpqSiDockingStation 3 }
cpqSiDockingStationAssetTag OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a customer changeable identifier that is set to the docking
station serial number at the time of manufacture.
The string will be empty if the docking station does not report an
asset tag or the system does not interface to a docking station."
::= { cpqSiDockingStation 4}
-- ****************************************************************************
-- System Information FRU Group
-- ============================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiFru Group (1.3.6.1.4.1.232.2.2.12)
--
-- The cpqsiFru group describes the Field Replaceable Units in the
-- server system.
--
--
-- Implementation of the cpqSiFru group is mandatory for all
-- Server Agents that support the Compaq System Information MIB.
--
-- ****************************************************************************
cpqSiFruTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSiFruEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of Field Replaceable Units of system, providing
inventory and asset control information. This table is
referenced from logical hardware descriptions elsewhere in
the MIB."
::= { cpqSiFru 1 }
cpqSiFruEntry OBJECT-TYPE
SYNTAX CpqSiFruEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry represents a Field Replaceable Unit (FRU) of hardware."
INDEX { cpqSiFruIndex }
::= { cpqSiFruTable 1 }
CpqSiFruEntry ::=
SEQUENCE {
cpqSiFruIndex INTEGER,
cpqSiFruType INTEGER,
cpqSiFruDescr DisplayString,
cpqSiFruVendor DisplayString,
cpqSiFruPartNumber DisplayString,
cpqSiFruRevision DisplayString,
cpqSiFruFirmwareRevision DisplayString,
cpqSiFruSerialNumber DisplayString,
cpqSiFruAssetNo DisplayString,
cpqSiFruClass INTEGER,
cpqSiFruSlotNumber DisplayString,
cpqSiFruSubAssemblyNumber INTEGER,
cpqSiFruAssemblyNumber INTEGER,
cpqSiFruChassisNumber INTEGER,
cpqSiFruPositionNumber INTEGER,
cpqSiFruCabinetIDNumber INTEGER,
cpqSiFruSiteLocation INTEGER,
cpqSiFruDiagStatus INTEGER,
cpqSiFruExtendedDiagStatus INTEGER
}
cpqSiFruIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A locally-unique index value."
::= { cpqSiFruEntry 1 }
cpqSiFruType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1) ,
other(2) ,
motherBoard(3) ,
processor(4) ,
memoryCard(5) ,
memoryModule(6) ,
peripheralDevice(7) ,
systemBusBridge(8) ,
powerSupply(9) ,
chassis(10) ,
fan(11) ,
ioCard(12)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"General category of the type of FRU that this is."
::= { cpqSiFruEntry 2 }
cpqSiFruDescr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"More detailed description of FRU type, if known."
::= { cpqSiFruEntry 3 }
cpqSiFruVendor OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Manufacturer name or ID."
::= { cpqSiFruEntry 4 }
cpqSiFruPartNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number by which this unit is orderable."
::= { cpqSiFruEntry 5 }
cpqSiFruRevision OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Version number of this unit. If artwork level is available, it will
appear as 'Artwork: XXX' following FRU version portion."
::= { cpqSiFruEntry 6 }
cpqSiFruFirmwareRevision OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The revision of the firmware, if any. Otherwise null."
::= { cpqSiFruEntry 7 }
cpqSiFruSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial number of this unit's instance."
::= { cpqSiFruEntry 8 }
cpqSiFruAssetNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The asset number for this unit. This string may be limited."
::= { cpqSiFruEntry 9 }
cpqSiFruClass OBJECT-TYPE
SYNTAX INTEGER {
unknown(1) ,
other(2) ,
currentBoardInSlot(3) ,
priorBoardInSlot(4) ,
parentBoard(5) ,
priorParentBoard(6) ,
priorParentSystem(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Represents the status category of the unit."
::= { cpqSiFruEntry 10 }
cpqSiFruSlotNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Physical slot number of FRU."
::= { cpqSiFruEntry 11 }
cpqSiFruSubAssemblyNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Subassembly containing this FRU. From FRU V5.0."
::= { cpqSiFruEntry 12 }
cpqSiFruAssemblyNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Assembly containing this FRU. From FRU V5.0."
::= { cpqSiFruEntry 13 }
cpqSiFruChassisNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Chassis containing this FRU. From FRU V5.0."
::= { cpqSiFruEntry 14 }
cpqSiFruPositionNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Position in Chassis to help locate FRU. From FRU V5.0."
::= { cpqSiFruEntry 15 }
cpqSiFruCabinetIDNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Cabinet number containing this FRU. From FRU V5.0."
::= { cpqSiFruEntry 16 }
cpqSiFruSiteLocation OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Site code for system containing this FRU. From FRU V5.0."
::= { cpqSiFruEntry 17 }
cpqSiFruDiagStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ok(2),
degraded(3),
failed(4),
disabled(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Use system status values to describe current state of the
FRU."
::= { cpqSiFruEntry 18 }
cpqSiFruExtendedDiagStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Diagnostic Status value returned by Device Specific
diagnostics. Usually through a diagnostic status register
on the device. See product manual for bit descriptions."
::= { cpqSiFruEntry 19 }
-- ****************************************************************************
-- System Information Rack and Enclosure Group
-- ===========================================
--
-- The compaq enterprise (1.3.6.1.4.1.232)
-- cpqSystemInfo Group (1.3.6.1.4.1.232.2)
-- cpqSiComponent Group (1.3.6.1.4.1.232.2.2)
-- cpqSiRackEnclosure Group (1.3.6.1.4.1.232.2.2.13)
--
-- The cpqSiRackEnclosure group indicates the availability of rack and/or
-- enclosure based systems.
--
-- :CPQ,DEV:
-- This table will be empty for stand-alone servers.
-- ICE systems will have one entry for noEnclosureManagement(2).
-- GARdian systems will have one entry for enclosureManagement(3).
-- :CPQ,ENDDEV:
-- ****************************************************************************
cpqSiRackEnclosureMgrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSiRackEnclosureMgrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of possible rack and/or enclosure based systems."
::= { cpqSiRackEnclosure 2 }
cpqSiRackEnclosureMgrEntry OBJECT-TYPE
SYNTAX CpqSiRackEnclosureMgrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A entry for a rack and/or enclosure based system."
INDEX { cpqSiRackEnclosureMgrIndex }
::= { cpqSiRackEnclosureMgrTable 1 }
CpqSiRackEnclosureMgrEntry ::=
SEQUENCE {
cpqSiRackEnclosureMgrIndex INTEGER,
cpqSiRackEnclosureMgrType INTEGER,
cpqSiRackEnclosureMgrIpAddr DisplayString,
cpqSiRackEnclosureMgrWebLink DisplayString,
cpqSiRackEnclosureMgrCondition INTEGER
}
cpqSiRackEnclosureMgrIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A locally-unique index value."
::= { cpqSiRackEnclosureMgrEntry 1 }
cpqSiRackEnclosureMgrType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
noEnclosureManagement(2),
enclosureManagement(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value specifies the type of enclosure management.
other(1)
When the type not be determined.
noEnclosureManagement(2)
The server is part of a rack/enclosure managed system, but there
is no dedicated enclosure manager.
enclosureManagement(3)
The server is part of a rack/enclosure managed system with a
dedicated enclosure manager."
::= { cpqSiRackEnclosureMgrEntry 2 }
cpqSiRackEnclosureMgrIpAddr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address of the rack enclosure manager.
The string will be empty if the enclosure does not report the
information or it could not be determined."
::= { cpqSiRackEnclosureMgrEntry 3 }
cpqSiRackEnclosureMgrWebLink OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The web link to the enclosure managers web based management
information for the enclosure.
The string will be empty if the enclosure does not report the
information or it could not be determined."
::= { cpqSiRackEnclosureMgrEntry 4 }
cpqSiRackEnclosureMgrCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The overall condition of the Enclosure Manager. For more detailed
status information, follow the cpqSiEnclosureMgrWebLink through
the Compaq Web Management Agent interface.
other(1)
This is the default condition for systems when
cpqSiRackEnclosureMgrType has a value of
noEnclosureManagement(2).
When cpqSiRackEnclosureMgrType has a value of
enclosureManagement(3), this indicates the status of the
enclosure manager could not be determined.
ok(2)
The enclosure manager is in an ok state. Follow the
cpqSiRackEnclosureMgrWebLink link in the Web Management Agents
to manage the enclosure.
degraded(3)
The enclosure manager is in a degraded state. Follow the
cpqSiRackEnclosureMgrWebLink link in the Web Management Agents
to manage the enclosure.
failed(4)
The enclosure manager is in a failed state. Follow the
cpqSiRackEnclosureMgrWebLink link in the Web Management Agents
to manage the enclosure."
::= { cpqSiRackEnclosureMgrEntry 5 }
-- ****************************************************************************
-- System Info MIB Trap Definitions
-- ================================
-- :CPQ,DEV:
-- System Info MIB trap definitions are based on the compaq (232)
-- enterprise and begin with 2001 through 2999.
-- :CPQ,ENDDEV:
--
-- The SNMP trap messages must not be bigger than 484 octets (bytes).
--
-- Trap support in an SNMP agent implementation is optional. An SNMP
-- agent implementation may support all, some, or none of the traps.
-- If traps are supported, The user should be provided with the option of
-- disabling traps.
-- **************************************************************************
cpqSiHoodRemoved TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags }
DESCRIPTION
"System hood is removed.
The hood status has been set to removed. The
system's hood is not in a properly installed state. This
situation may result in improper cooling of the system due
to air flow changes caused by the missing hood.
User Action: Replace the cover (hood), ensure the system's cover
is properly installed. Verify the system is in working order."
--#TYPE "System hood is removed"
--#SUMMARY "Hood is removed from unit."
--#ARGUMENTS {}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
::= 2001
cpqSiMonitorConditionOK TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
DESCRIPTION
"Fault reporting features have returned to within their normal
operating range for the monitor indicated by cpqSiMonitorIndex.
The monitor's condition has been set to OK.
User Action: None."
--#TYPE "Monitor Condition OK"
--#SUMMARY "The monitor's condition has been set to OK."
--#ARGUMENTS {}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
-- :CPQ,DEV:
-- This trap should be sent when should be sent when cpqSiMonitorStatus
-- transistions from thermalDegraded(4) or operationalFailure(5) to OK(2).
-- :CPQ,ENDDEV:
::= 2002
cpqSiMonitorConditionDegraded TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
DESCRIPTION
"A fault reporting feature has exceeded normal limits for
the monitor indicated by the cpqSiMonitorIndex. The monitor's
condition is degraded due to the internal temperature exceeding
normal operating limits. The monitor is still useable, but
action should be taken to return the condition to OK.
User Action: Physically check for obstructions to air flow around
the monitor. Check the thermostat in the room that the system
occupies. Allow the monitor to cool by turning off the monitor
for 5 minutes then turn the monitor back on. After the monitor
cools, another alarm indicating an improving condition, such as
Monitor OK, will be issued."
--#TYPE "Monitor Condition Degraded"
--#SUMMARY "The monitor's condition has been set to degraded."
--#ARGUMENTS {}
--#SEVERITY MINOR
--#TIMEINDEX 99
--#STATE DEGRADED
::= 2003
cpqSiMonitorConditionFailed TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqSiMonitorIndex }
DESCRIPTION
"A fault reporting feature has exceeded normal limits in the
monitor indicated by the cpqSiMonitorIndex. The monitor's
condition has been set to failed due to an operational feature
exceeding normal operating limits. The monitor will not be
useable and should be replaced.
User Action: Make a note of the monitor model number and serial
number. Replace the monitor.
Refer to the appropriate Maintenance and Service Guide for
detailed information on a component replacement."
--#TYPE "Monitor Condition Failed"
--#SUMMARY "The monitor's condition has been set to failed."
--#ARGUMENTS {}
--#SEVERITY CRITICAL
--#TIMEINDEX 99
--#STATE NONOPERATIONAL
::= 2004
cpqSiCorrMemErrStatusDegraded TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqSiMemErrorIndex }
DESCRIPTION
"Correctable memory error count has exceeded the threshold for the
memory module indicated by the 'cpqSiMemErrorIndex' variable.
The appropriate cpqSiMemModuleECCStatus has been set to degraded.
User Action: For Desktops, the System Administrator should run
the F10 Diagnostics on this system and select RAM LONG TEST. If
it is determined that a module needs replacing, schedule
maintenance for the system and replace the failed memory module.
Refer to the appropriate Maintenance and Service Guide for detailed
information on a component replacement."
--#TYPE "Excessive Correctable Memory Errors"
--#SUMMARY "The Memory Module %d ECC status has been set to degraded."
--#ARGUMENTS {3}
--#SEVERITY MINOR
--#TIMEINDEX 99
--#STATE DEGRADED
::= 2005
cpqSiCorrMemErrStatusOk TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqSiMemErrorIndex }
DESCRIPTION
"Correctable memory error count is now below the threshold for the
memory module indicated by the 'cpqSiMemErrorIndex' variable. The
appropriate cpqSiMemModuleECCStatus has been set to ok.
User Action: None."
--#TYPE "Correctable Memory Errors Count OK"
--#SUMMARY "The Memory Module %d ECC status has been set to OK."
--#ARGUMENTS {3}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 2006
cpqSiMemConfigChange TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqSiMemConfigChangeData }
DESCRIPTION
"A memory configuration change has occured. CpqSiMemConfigChangeData
will indicate which memory modules slots have changed.
User Action: You may want to verify a valid reason for a memory
configuration to have occurred. If system issuing the alert is
a Desktop running NT, the memory configuration change information
is also logged in the NT System Log."
--#TYPE "Memory modules have changed"
--#SUMMARY "The system's memory configuration has changed."
--#ARGUMENTS {}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
-- :CPQ,DEV:
-- This trap has been designed for the Desktop Agent.
-- See cpqSiMemConfigChangeData for a message template.
-- :CPQ,ENDDEV:
::= 2007
cpqSiHotPlugSlotBoardRemoved TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqSiHotPlugSlotChassis,
cpqSiHotPlugSlotIndex }
DESCRIPTION
"Hot Plug Slot Board Removed.
A Hot Plug Slot Board has been removed from the specified
chassis and slot.
User Action: None."
--#TYPE "Hot Plug Slot Board Removed"
--#SUMMARY "Hot Plug Slot Board Removed from Chassis %d, Slot %d."
--#ARGUMENTS {2, 3}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 2008
cpqSiHotPlugSlotBoardInserted TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqSiHotPlugSlotChassis,
cpqSiHotPlugSlotIndex }
DESCRIPTION
"Hot Plug Slot Board Inserted.
A Hot Plug Slot Board has been inserted into the specified
chassis and slot.
User Action: None."
--#TYPE "Hot Plug Slot Board Inserted"
--#SUMMARY "Hot Plug Slot Board Inserted into Chassis %d, Slot %d."
--#ARGUMENTS {2, 3}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 2009
cpqSiHotPlugSlotPowerUpFailed TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqSiHotPlugSlotChassis,
cpqSiHotPlugSlotIndex, cpqSiHotPlugSlotErrorStatus }
DESCRIPTION
"Hot Plug Slot Board Failed Power-Up.
A Hot Plug Slot Board has failed to power-up in the specified
chassis and slot.
User Action: Insure the board and all cables are installed
correctly and the board type and revision are the same as
the replaced board."
--#TYPE "Hot Plug Slot Board Failed"
--#SUMMARY "Hot Plug Slot Board Failed in Chassis %d, Slot %d, Error %d."
--#ARGUMENTS {2, 3, 4}
--#SEVERITY CRITICAL
--#TIMEINDEX 99
--#STATE FAILED
-- :CPQ,DEV:
-- One of the two traps, BoardInserted or BoardFailed will be generated
-- when a board is inserted depending of the success or failure of the
-- board to be powered up.
-- :CPQ,ENDDEV:
::= 2010
cpqSiSysBatteryFailure TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex,
cpqSiSysBatterySerialNum }
DESCRIPTION
"The battery indicated by cpqSiSysBatteryIndex has failed
and must be replaced.
User Action: Contact your System Administrator or
Compaq Authorized Reseller to order a replacement battery.
Recycle your old battery. For proper disposal information,
refer to the documentation that came with your computer."
--#TYPE "Battery Failure"
--#SUMMARY "Battery %d has failed."
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
-- :CPQ,DEV:
-- This trap should be generated when cpqSiSysBatteryStatus goes
-- from ok to permanentFailure.
--
-- :CPQ,ENDDEV:
::= 2011
cpqSiSysBatteryChargingDegraded TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex,
cpqSiSysBatterySerialNum }
DESCRIPTION
"Significant battery degradation has occurred with battery
indicated by cpqSiSysBatteryIndex. The battery can
no longer be fully recharged.
User Action: If using multiple batteries, run
Compaq Power Conservation Utility to identify the
battery location. Contact your System Administrator
or Compaq Authorized Reseller to order a replacement
battery."
--#TYPE "Battery Charging Degradation"
--#SUMMARY "Battery %d has degraded charging capacity."
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
-- :CPQ,DEV:
-- This trap should be generated when cpqSiSysBatteryStatus goes
-- from ok to capacityDegraded.
--
-- :CPQ,ENDDEV:
::= 2012
cpqSiSysBatteryCalibrationError TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqSiSysBatteryIndex,
cpqSiSysBatterySerialNum }
DESCRIPTION
"Calibration is needed with battery
indicated by cpqSiSysBatteryIndex. The battery can
not correctly indicate capacity.
User Action: Run Compaq Power Conservation Utility. Contact
your System Administrator or Compaq Authorized Reseller to
order a replacement battery."
--#TYPE "Battery Calibration Error"
--#SUMMARY "Battery %d has calibration error."
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
-- :CPQ,DEV:
-- This trap should be generated when cpqSiSysBatteryStatus goes
-- from ok to chargingCalibrationError.
--
-- :CPQ,ENDDEV:
::= 2013
END