snmp_mib_archive/atqbriu.mib
Heston Snodgrass 89bf4b016e initial commit
2016-12-15 15:03:18 -07:00

109 lines
3.1 KiB
Plaintext
Executable File

ADTRAN-ATLAS550-QUAD-BRI-U-MIB DEFINITIONS ::= BEGIN
-- TITLE: Atlas 550 Quad BRI-U Option Module MIB
-- FILENAME: atqbriu.mib
-- PARTNUMBER:
-- AUTHOR: Jason Schock
-- HISTORY:
-- 06/18/2002 Created.
-- This MIB supports the ATLAS 550 Quad BRI-U Option Module.
IMPORTS
enterprises, Counter
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
adATLASBRIIfIndex
FROM ADTRAN-ATLAS-BRI-MIB;
-- OBJECT IDENTIFIERS
adtran OBJECT IDENTIFIER ::= { enterprises 664 }
adMgmt OBJECT IDENTIFIER ::= { adtran 2 }
adATLAS550QuadBRIUmg OBJECT IDENTIFIER ::= { adMgmt 274 }
--___________________________________________________________
-- The ATLAS 550 Quad BRI-U Interface Status Table --
--___________________________________________________________
adATLAS550QuadBRIUIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AdATLAS550QuadBRIUIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The ATLAS 550 Quad BRI-U Interface Status Table."
::= { adATLAS550QuadBRIUmg 1 }
adATLAS550QuadBRIUIfEntry OBJECT-TYPE
SYNTAX AdATLAS550QuadBRIUIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the ATLAS 550 Quad BRI-U Interface Status Table"
INDEX { adATLAS550QuadBRIUIfIndex }
::= { adATLAS550QuadBRIUIfTable 1 }
AdATLAS550QuadBRIUIfEntry ::=
SEQUENCE {
adATLAS550QuadBRIUIfIndex
INTEGER,
adATLAS550QuadBRIUIfNEBE
Counter,
adATLAS550QuadBRIUIfFEBE
Counter,
adATLAS550QuadBRIUIfResetBECounts
INTEGER
}
-- Interface Number
adATLAS550QuadBRIUIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable indicates the interface number of a
particular port on the Quad BRI-U Option Module within
the ATLAS 550 product. This number will be the same as
the ifIndex located in the MIB-II interface table."
::= { adATLAS550QuadBRIUIfEntry 1 }
-- Near End Block Error Count
adATLAS550QuadBRIUIfNEBE OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable keeps count of the amount of blocks
with errors recieved at the local interface."
::= { adATLAS550QuadBRIUIfEntry 2 }
-- Far End Block Error Count
adATLAS550QuadBRIUIfFEBE OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable keeps count of the amount of blocks
with errors recieved at the far interface."
::= { adATLAS550QuadBRIUIfEntry 3 }
-- Reset NEBE and FEBE Counts
adATLAS550QuadBRIUIfResetBECounts OBJECT-TYPE
SYNTAX INTEGER {
resetCounts(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable is used to reset the NEBE and FEBE counters."
::= { adATLAS550QuadBRIUIfEntry 4 }
END