snmp_mib_archive/RC-DIAG-MIB.mib
Heston Snodgrass 89bf4b016e initial commit
2016-12-15 15:03:18 -07:00

1484 lines
54 KiB
Plaintext

RC-DIAG-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, IpAddress
FROM SNMPv2-SMI
DisplayString, TruthValue, MacAddress, RowStatus
FROM SNMPv2-TC
InterfaceIndex
FROM IF-MIB
rcDiag, rcMirror, EnableValue
FROM RAPID-CITY;
rcDiagMib MODULE-IDENTITY
LAST-UPDATED "200510120000Z"
ORGANIZATION "Bay Networks, Rapid-City Group"
CONTACT-INFO "
Edwin Tsang
Postal: Bay Networks, Inc.
4401 Great America Parkway
Santa Clara, CA 95052-8185
Tel: 408-495-6159
Fax: 408-495-5215
E-mail: edwin_tsang@baynetworks.com
"
DESCRIPTION "Enterprise MIB for the Accelar product family."
REVISION "200510120000Z" -- 12 Oct. 2005
DESCRIPTION "Version 7: Add pairForce(7) to rcDiagVctPair*Status."
REVISION "200502010000Z" -- 01 Feb. 2005
DESCRIPTION "Version 6: Fixes to the new objects in rcDiagVctTable."
REVISION "200501140000Z" -- 14 Jan. 2005
DESCRIPTION "Version 5: Added new objects in rcDiagVctTable to
support use of broadcom chips for cable
testing."
REVISION "200412220000Z" -- 22 Dec. 2004
DESCRIPTION "Version 4: Modified rcDiagMirrorByPortMode For PR"
REVISION "200407200000Z" -- 20 July 2004
DESCRIPTION "Version 3: Added version info"
::= { rcDiag 0 }
-- Mirror Group
rcMirrorSaveConfig OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Control whether Mirror configuration information
should be saved to NVRAM so mirror settings can
be automatically reinstalled after a system
reboot.
Setting rcMirrorSaveConfig to true does not
immediately save the configuration information.
The save happens when the rcSysAction variable
is set to 'saveToNVRAM(4)'."
::= { rcMirror 1 }
rcMirrorByPort OBJECT IDENTIFIER ::= { rcMirror 2 }
rcMirrorByPortEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Used to indicate whether the mirror by port
feature is active. The system can only support
mirroring on two ports. When this feature is
active, all packets received on the port(s)
specified by rcMirrorSrcPortOne and/or
rcMirrorSrcPortTwo are copied to rcMirrorDstPort.
The mirroring operation is non-intrusive."
DEFVAL { false }
::= { rcMirrorByPort 1 }
rcMirrorByPortMirrorPort OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "The ifIndex of the port to forward mirrored frames to."
::= { rcMirrorByPort 2 }
rcMirrorByPortEnableMirroredPortOne OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Used to indicate whether the port specified in
rcMirrorByPortMirroredPortOne should be mirrored."
DEFVAL { false }
::= { rcMirrorByPort 3 }
rcMirrorByPortMirroredPortOne OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "The ifIndex of the port to be mirrored. That
is, traffic received on this port will be sent
to the mirror port."
::= { rcMirrorByPort 4 }
rcMirrorByPortEnableMirroredPortTwo OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Used to indicate whether the port specified in
rcMirrorByPortMirroredPortTwo should be mirrored."
DEFVAL { false }
::= { rcMirrorByPort 5 }
rcMirrorByPortMirroredPortTwo OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "The ifIndex of the port to be mirrored. That
is, traffic received on this port will be sent
to the mirror port."
::= { rcMirrorByPort 6 }
-- Diag Mirror by port Table
rcDiagMirrorByPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcDiagMirrorByPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table is used to configure the Mirror By
Port feature. This feature allows the device
to forward a copy of each packet seen on a
particular port to a different port."
::= { rcDiag 1 }
rcDiagMirrorByPortEntry OBJECT-TYPE
SYNTAX RcDiagMirrorByPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing mirror by port information."
INDEX { rcDiagMirrorByPortId }
::= { rcDiagMirrorByPortTable 1 }
RcDiagMirrorByPortEntry ::= SEQUENCE {
rcDiagMirrorByPortId INTEGER,
rcDiagMirrorByPortMirroredPort InterfaceIndex,
rcDiagMirrorByPortMirroringPort InterfaceIndex,
rcDiagMirrorByPortMode INTEGER,
rcDiagMirrorByPortEnable TruthValue,
rcDiagMirrorByPortRowStatus RowStatus,
rcDiagMirrorByPortOctapidId Integer32, --excluded
rcDiagMirrorByPortPid Integer32,
rcDiagMirrorRemoteMirrorVlanId INTEGER
}
rcDiagMirrorByPortId OBJECT-TYPE
SYNTAX INTEGER(1..383)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Entry id."
::= { rcDiagMirrorByPortEntry 1 }
rcDiagMirrorByPortMirroredPort OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to configure the 'mirrored' port. The port
where packets are copied from."
::= { rcDiagMirrorByPortEntry 2 }
rcDiagMirrorByPortMirroringPort OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to configure the 'mirroring' port. The port
where packets are copied to."
::= { rcDiagMirrorByPortEntry 3 }
rcDiagMirrorByPortMode OBJECT-TYPE
SYNTAX INTEGER {
tx(1),
rx(2),
both(3),
rxFilter(4),
txFilter(5),
bothFilter(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to configure the 'mode' of the mirror operation.
'tx' means packets being transmitted on the 'mirrored'
port will be copied. 'rx' means packets received on
the 'mirrored' port will be copied. 'both' means
all traffic on the 'mirrored' port will be copied.
'rxFilter' means packets received on the 'mirrored'
port is copied only if it macthes filter criteria.
'txFilter' means packets being transmitted on the
'mirrorred' port is copied only if it matches filter
criteria. 'bothFilter' means both ingress and egress
traffic will be copied if it matches either ingress or
egress filter on the 'mirrored' port."
DEFVAL { rx }
::= { rcDiagMirrorByPortEntry 4 }
rcDiagMirrorByPortEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to enable/disable this entry."
DEFVAL { true }
::= { rcDiagMirrorByPortEntry 5 }
rcDiagMirrorByPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Row status of this entry."
::= { rcDiagMirrorByPortEntry 6 }
rcDiagMirrorByPortOctapidId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Octapid Id for a port."
::= { rcDiagMirrorByPortEntry 7 }
rcDiagMirrorByPortPid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Pid for a port."
::= { rcDiagMirrorByPortEntry 8 }
rcDiagMirrorRemoteMirrorVlanId OBJECT-TYPE
SYNTAX INTEGER (0..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "vlan-id to which mirrored packets needs to
be send for remote mirroring. If set, this
vlan id is used in mirror tag of the remote
mirrored packet"
::= { rcDiagMirrorByPortEntry 9 }
-- Diag Port Conv Steering Table
rcDiagPortConvSteeringTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcDiagPortConvSteeringEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Diag Port Conv Steering Table"
::= { rcDiag 2 }
rcDiagPortConvSteeringEntry OBJECT-TYPE
SYNTAX RcDiagPortConvSteeringEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing infomation of Diag Port Conv Steering."
INDEX { rcDiagPortConvSteeringId }
::= { rcDiagPortConvSteeringTable 1 }
RcDiagPortConvSteeringEntry ::= SEQUENCE {
rcDiagPortConvSteeringId Integer32,
rcDiagPortConvSteeringPortOne Integer32,
rcDiagPortConvSteeringPortTwo Integer32,
rcDiagPortConvSteeringMode INTEGER,
rcDiagPortConvSteeringForwardPort Integer32,
rcDiagPortConvSteeringEnable TruthValue,
rcDiagPortConvSteeringRowStatus RowStatus
}
rcDiagPortConvSteeringId OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Entry id."
::= { rcDiagPortConvSteeringEntry 1 }
rcDiagPortConvSteeringPortOne OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "IfIndex for port one"
::= { rcDiagPortConvSteeringEntry 2 }
rcDiagPortConvSteeringPortTwo OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "IfIndex for port two"
::= { rcDiagPortConvSteeringEntry 3 }
rcDiagPortConvSteeringMode OBJECT-TYPE
SYNTAX INTEGER {
oneToTwo(1),
twoToOne(2),
both(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to specify the traffic flow that should be
captured between ports one and two."
::= { rcDiagPortConvSteeringEntry 4 }
rcDiagPortConvSteeringForwardPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "IfIndex of the port where captured traffic should
be forwarded to."
::= { rcDiagPortConvSteeringEntry 5 }
rcDiagPortConvSteeringEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable this entry."
DEFVAL { true }
::= { rcDiagPortConvSteeringEntry 6 }
rcDiagPortConvSteeringRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to create/delete entries in the rcDiagMirrorByPortTable."
::= { rcDiagPortConvSteeringEntry 7 }
-- Diag Mac Conv Steering Table
rcDiagMacConvSteeringTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcDiagMacConvSteeringEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Diag Mac Conv Steering Table"
::= { rcDiag 3 }
rcDiagMacConvSteeringEntry OBJECT-TYPE
SYNTAX RcDiagMacConvSteeringEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing infomation of Diag Mac Conv Steering."
INDEX { rcDiagMacConvSteeringId }
::= { rcDiagMacConvSteeringTable 1 }
RcDiagMacConvSteeringEntry ::= SEQUENCE {
rcDiagMacConvSteeringId Integer32,
rcDiagMacConvSteeringSrcMac MacAddress,
rcDiagMacConvSteeringDstMac MacAddress,
rcDiagMacConvSteeringInPort Integer32,
rcDiagMacConvSteeringForwardPort Integer32,
rcDiagMacConvSteeringEnable TruthValue,
rcDiagMacConvSteeringRowStatus RowStatus
}
rcDiagMacConvSteeringId OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Entry id."
::= { rcDiagMacConvSteeringEntry 1 }
rcDiagMacConvSteeringSrcMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Source MAC address"
::= { rcDiagMacConvSteeringEntry 2 }
rcDiagMacConvSteeringDstMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Destination MAC address"
::= { rcDiagMacConvSteeringEntry 3 }
rcDiagMacConvSteeringInPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "IfIndex of ingress port."
::= { rcDiagMacConvSteeringEntry 4 }
rcDiagMacConvSteeringForwardPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "IfIndex of the port where captured traffic should
be forwarded to."
::= { rcDiagMacConvSteeringEntry 5 }
rcDiagMacConvSteeringEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable this entry."
DEFVAL { true }
::= { rcDiagMacConvSteeringEntry 6 }
rcDiagMacConvSteeringRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to create/delete entries in the rcDiagMirrorByPortTable."
::= { rcDiagMacConvSteeringEntry 7 }
-- Diag Vct Table
rcDiagVctTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcDiagVctEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Diag Vct Table"
::= { rcDiag 4 }
rcDiagVctEntry OBJECT-TYPE
SYNTAX RcDiagVctEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing cable infomation and test result."
INDEX { rcDiagVctIfIndex }
::= { rcDiagVctTable 1 }
RcDiagVctEntry ::= SEQUENCE {
rcDiagVctIfIndex InterfaceIndex,
rcDiagVctNormalCableLength INTEGER,
rcDiagVctPhyType INTEGER,
rcDiagVctCableStatus INTEGER,
rcDiagVctPair1Status INTEGER,
rcDiagVctPair1ErrLength INTEGER,
rcDiagVctPair2Status INTEGER,
rcDiagVctPair2ErrLength INTEGER,
rcDiagVctPair3Status INTEGER,
rcDiagVctPair3ErrLength INTEGER,
rcDiagVctPair4Status INTEGER,
rcDiagVctPair4ErrLength INTEGER,
rcDiagVctStartTest TruthValue,
rcDiagVctTestDone TruthValue,
rcDiagVctCableCategory INTEGER,
rcDiagVctCableLength Integer32,
rcDiagVctPair1Polarity INTEGER,
rcDiagVctPair1Swap INTEGER,
rcDiagVctPair1Skew Integer32,
rcDiagVctPair2Polarity INTEGER,
rcDiagVctPair2Swap INTEGER,
rcDiagVctPair2Skew Integer32,
rcDiagVctPair3Polarity INTEGER,
rcDiagVctPair3Swap INTEGER,
rcDiagVctPair3Skew Integer32,
rcDiagVctPair4Polarity INTEGER,
rcDiagVctPair4Swap INTEGER,
rcDiagVctPair4Skew Integer32
}
rcDiagVctIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Port IfIndex."
::= { rcDiagVctEntry 1 }
rcDiagVctNormalCableLength OBJECT-TYPE
SYNTAX INTEGER {
cableLT50M(1),
cable50M80M(2),
cable80M110M(3),
cable110M140M(4),
cableGT140M(5),
cableUnknown(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Cable length, this indicates a range in which the
actual length falls."
::= { rcDiagVctEntry 2 }
rcDiagVctPhyType OBJECT-TYPE
SYNTAX INTEGER {
phy100M(1),
phy1000M(2),
phy10000M(3),
phy100000M(4),
phyUnknown(5),
bcm5464(6),
bcm5464s(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Phy type, 100MHz throught 1 GHz, or broadcom phy."
::= { rcDiagVctEntry 3 }
rcDiagVctCableStatus OBJECT-TYPE
SYNTAX INTEGER {
cableFail(1),
cableNormal(2),
cableOpen(3),
cableShorted(4),
cableNotApplicable(5),
cableUntested(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Status of the cable as a whole. The status of a
cable is in a sense, a summation of the status of its
pairs. If all the pairs are normal, then the cable is
normal. If the cable consists of zero or more normal
pairs and one or more open pairs, then the cable is
considered open. If it consists of shorted pairs and
normal pairs, then the cable is considered shorted.
Any combination of open and shorted pairs is
considered simply FAILED."
::= { rcDiagVctEntry 4 }
rcDiagVctPair1Status OBJECT-TYPE
SYNTAX INTEGER {
pairFail(1),
pairNormal(2),
pairOpen(3),
pairShorted(4),
pairNotApplicable(5),
pairNotTested(6),
pairForce(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The status of a single pair in the cable"
::= { rcDiagVctEntry 5 }
rcDiagVctPair1ErrLength OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Error Pair Length, in meters, measured by Time
Domain Reflectometry."
::= { rcDiagVctEntry 6 }
rcDiagVctPair2Status OBJECT-TYPE
SYNTAX INTEGER {
pairFail(1),
pairNormal(2),
pairOpen(3),
pairShorted(4),
pairNotApplicable(5),
pairNotTested(6),
pairForce(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The status of a single pair in the cable"
::= { rcDiagVctEntry 7 }
rcDiagVctPair2ErrLength OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Error Pair Length, in meters, measured by Time
Domain Reflectometry."
::= { rcDiagVctEntry 8 }
rcDiagVctPair3Status OBJECT-TYPE
SYNTAX INTEGER {
pairFail(1),
pairNormal(2),
pairOpen(3),
pairShorted(4),
pairNotApplicable(5),
pairNotTested(6),
pairForce(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The status of a single pair in the cable"
::= { rcDiagVctEntry 9 }
rcDiagVctPair3ErrLength OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Error Pair Length, in meters, measured by Time
Domain Reflectometry."
::= { rcDiagVctEntry 10 }
rcDiagVctPair4Status OBJECT-TYPE
SYNTAX INTEGER {
pairFail(1),
pairNormal(2),
pairOpen(3),
pairShorted(4),
pairNotApplicable(5),
pairNotTested(6),
pairForce(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The status of a single pair in the cable"
::= { rcDiagVctEntry 11 }
rcDiagVctPair4ErrLength OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Error Pair Length, in meters, measured by Time
Domain Reflectometry."
::= { rcDiagVctEntry 12 }
rcDiagVctStartTest OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Start VCT test, Set this object to TRUE to perform
a VCT test on the current port. A get on this
object produces an undefines value."
::= { rcDiagVctEntry 13 }
rcDiagVctTestDone OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "When a VCT test is started setting rcDiagVctStartTest,
this object is immediately set to FALSE by the switch
software. It remain FALSE until the test is completed,
when it is set to TRUE. When this object is TRUE,
then the management station can immediately perform
a GET on the test result for this port."
::= { rcDiagVctEntry 14 }
rcDiagVctCableCategory OBJECT-TYPE
SYNTAX INTEGER {
cat3(1),
cat5(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Cable type: CAT3 or CAT5."
::= { rcDiagVctEntry 15 }
rcDiagVctCableLength OBJECT-TYPE
SYNTAX Integer32 (0..255)
UNITS "Meters"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Length of cable in meters based on average electrical
length of 4 pairs. Measurement can be done when
traffic is live or not."
::= { rcDiagVctEntry 16 }
rcDiagVctPair1Polarity OBJECT-TYPE
SYNTAX INTEGER {
inversed(1),
normal(2),
invalid(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The polarity of a single pair in the cable."
::= { rcDiagVctEntry 17 }
rcDiagVctPair1Swap OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
swapped(2),
invalid(3),
error(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The pair swap in the cable."
::= { rcDiagVctEntry 18 }
rcDiagVctPair1Skew OBJECT-TYPE
SYNTAX Integer32 (-1..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Differential cable pair length in meters.
Skew measurement can only be performed when cable
gigabit link is up regardless of traffic activity.
A value of -1 means an error occured when trying
to get the length."
::= { rcDiagVctEntry 19 }
rcDiagVctPair2Polarity OBJECT-TYPE
SYNTAX INTEGER {
inversed(1),
normal(2),
invalid(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The polarity of a single pair in the cable."
::= { rcDiagVctEntry 20 }
rcDiagVctPair2Swap OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
swapped(2),
invalid(3),
error(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The pair swap in the cable."
::= { rcDiagVctEntry 21 }
rcDiagVctPair2Skew OBJECT-TYPE
SYNTAX Integer32 (-1..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Differential cable pair length in meters.
Skew measurement can only be performed when cable
gigabit link is up regardless of traffic activity.
A value of -1 means an error occured when trying
to get the length."
::= { rcDiagVctEntry 22 }
rcDiagVctPair3Polarity OBJECT-TYPE
SYNTAX INTEGER {
inversed(1),
normal(2),
invalid(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The polarity of a single pair in the cable."
::= { rcDiagVctEntry 23 }
rcDiagVctPair3Swap OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
swapped(2),
invalid(3),
error(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The pair swap in the cable."
::= { rcDiagVctEntry 24 }
rcDiagVctPair3Skew OBJECT-TYPE
SYNTAX Integer32 (-1..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Differential cable pair length in meters.
Skew measurement can only be performed when cable
gigabit link is up regardless of traffic activity.
A value of -1 means an error occured when trying
to get the length."
::= { rcDiagVctEntry 25 }
rcDiagVctPair4Polarity OBJECT-TYPE
SYNTAX INTEGER {
inversed(1),
normal(2),
invalid(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The polarity of a single pair in the cable."
::= { rcDiagVctEntry 26 }
rcDiagVctPair4Swap OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
swapped(2),
invalid(3),
error(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The pair swap in the cable."
::= { rcDiagVctEntry 27 }
rcDiagVctPair4Skew OBJECT-TYPE
SYNTAX Integer32 (-1..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Differential cable pair length in meters.
Skew measurement can only be performed when cable
gigabit link is up regardless of traffic activity.
A value of -1 means an error occured when trying
to get the length."
::= { rcDiagVctEntry 28 }
rcDiagSaveConfig OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Used to configure whether the various mirror feature
settings should be saved and restored across system
reboot."
::= { rcDiag 10 }
rcDiagMirrorByPortTblSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate table size."
::= { rcDiag 11 }
rcDiagPortConvSteeringTblSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate table size."
::= { rcDiag 12 }
rcDiagMacConvSteeringTblSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate table size."
::= { rcDiag 13 }
rcDiagDiagnosticsEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Used to enable/disable the mirroring feature
for the entire device. This setting overrides
any setting in the various mirroring tables."
DEFVAL { false }
::= { rcDiag 14 }
-- rcDiagPcap Group
rcDiagPcap OBJECT IDENTIFIER ::= { rcDiag 15 }
rcDiagPcapEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To enable pcap in secondary CPU"
DEFVAL { false }
::= { rcDiagPcap 1 }
rcDiagPcapBufferWrap OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To enable buffer wrap-around when buffer is full.
If set, pcap will continue to capture pkts, otherwise
stops pkt storing"
DEFVAL { false }
::= { rcDiagPcap 2 }
rcDiagPcapPcmciaWrap OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To wrap around the PCMCIA when saving data in PCMCIA"
DEFVAL { false }
::= { rcDiagPcap 3 }
rcDiagPcapFrameSize OBJECT-TYPE
SYNTAX INTEGER (64..9600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Number of bytes of pkts needs to be stored"
DEFVAL { 64 }
::= { rcDiagPcap 4 }
rcDiagPcapBufferSize OBJECT-TYPE
SYNTAX INTEGER (2..256)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "memory to be allocated for capturing the pkt"
DEFVAL { 2 }
::= { rcDiagPcap 5 }
rcDiagPcapAutoSave OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To save data automatically when buffer is full"
DEFVAL { false }
::= { rcDiagPcap 6 }
rcDiagPcapAutoSaveFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Name of the file in which the pkt is to be stored"
::= { rcDiagPcap 7 }
rcDiagPcapAutoSaveDevice OBJECT-TYPE
SYNTAX INTEGER {
pcmcia(0),
network(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Where to store the captured pkts. If the option is
network, the user need to enter an IP address also"
::= { rcDiagPcap 8 }
rcDiagPcapAutoSaveNetworkIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "ip address of the remote host where the data
needs to be stored. This field is valid only
if the device is network"
::= { rcDiagPcap 9 }
rcDiagPcapFilterTableSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of entries in the
Filter table"
::= { rcDiagPcap 10 }
-- rcDiagPcapFilterTable
rcDiagPcapFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcDiagPcapFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table used to store pcap secondary filters"
::= { rcDiagPcap 11 }
rcDiagPcapFilterEntry OBJECT-TYPE
SYNTAX RcDiagPcapFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Pcap secondary filter desc"
INDEX {rcDiagPcapFilterId }
::= { rcDiagPcapFilterTable 1 }
RcDiagPcapFilterEntry ::= SEQUENCE {
rcDiagPcapFilterId INTEGER,
rcDiagPcapFilterEnable EnableValue,
rcDiagPcapFilterAction INTEGER,
rcDiagPcapFilterSrcMac MacAddress,
rcDiagPcapFilterSrcMask INTEGER,
rcDiagPcapFilterIsInverseSrcMac TruthValue,
rcDiagPcapFilterDstMac MacAddress,
rcDiagPcapFilterDstMask INTEGER,
rcDiagPcapFilterIsInverseDstMac TruthValue,
rcDiagPcapFilterVlanId INTEGER,
rcDiagPcapFilterToVlanId INTEGER,
rcDiagPcapFilterIsInverseVlanId TruthValue,
rcDiagPcapFilterPbit INTEGER,
rcDiagPcapFilterToPbit INTEGER,
rcDiagPcapFilterIsInversePbit TruthValue,
rcDiagPcapFilterEtherType INTEGER,
rcDiagPcapFilterToEtherType INTEGER,
rcDiagPcapFilterIsInverseEtherType TruthValue,
rcDiagPcapFilterProtocolType INTEGER,
rcDiagPcapFilterToProtocolType INTEGER,
rcDiagPcapFilterIsInverseProtocolType TruthValue,
rcDiagPcapFilterSrcIp IpAddress,
rcDiagPcapFilterToSrcIp IpAddress,
rcDiagPcapFilterIsInverseSrcIp TruthValue,
rcDiagPcapFilterDstIp IpAddress,
rcDiagPcapFilterToDstIp IpAddress,
rcDiagPcapFilterIsInverseDstIp TruthValue,
rcDiagPcapFilterDscp INTEGER,
rcDiagPcapFilterToDscp INTEGER,
rcDiagPcapFilterIsInverseDscp TruthValue,
rcDiagPcapFilterRowStatus RowStatus,
rcDiagPcapFilterDscpMatchZero TruthValue,
rcDiagPcapFilterPbitMatchZero TruthValue
}
rcDiagPcapFilterId OBJECT-TYPE
SYNTAX INTEGER (1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Unique ID that represents the filter"
::= { rcDiagPcapFilterEntry 1 }
rcDiagPcapFilterEnable OBJECT-TYPE
SYNTAX EnableValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Filter is enabled or not"
DEFVAL { disable }
::= { rcDiagPcapFilterEntry 2 }
rcDiagPcapFilterAction OBJECT-TYPE
SYNTAX INTEGER {
drop(0),
capture(1),
trigger-on(2),
trigger-off(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Action to be takesn when policy is matched"
DEFVAL { capture }
::= { rcDiagPcapFilterEntry 3 }
rcDiagPcapFilterSrcMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Soruce mac address to match"
::= { rcDiagPcapFilterEntry 4 }
rcDiagPcapFilterSrcMask OBJECT-TYPE
SYNTAX INTEGER (1..6)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Soruce mac address mask. Used to specify a range"
DEFVAL { 6 }
::= { rcDiagPcapFilterEntry 5 }
rcDiagPcapFilterIsInverseSrcMac OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Soruce mac address Inverse. when set the mac
addresses otherthan specified is matched"
DEFVAL { false }
::= { rcDiagPcapFilterEntry 6 }
rcDiagPcapFilterDstMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Destination mac address"
::= { rcDiagPcapFilterEntry 7 }
rcDiagPcapFilterDstMask OBJECT-TYPE
SYNTAX INTEGER (1..6)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Destination mac address mask. Used to specify a range"
DEFVAL { 6 }
::= { rcDiagPcapFilterEntry 8 }
rcDiagPcapFilterIsInverseDstMac OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Destination mac address Inverse. when set the mac
addresses otherthan specified is matched"
DEFVAL { false }
::= { rcDiagPcapFilterEntry 9 }
rcDiagPcapFilterVlanId OBJECT-TYPE
SYNTAX INTEGER (0..4092)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Vlan-id of the packet to be matched"
DEFVAL { 0 }
::= { rcDiagPcapFilterEntry 10 }
rcDiagPcapFilterToVlanId OBJECT-TYPE
SYNTAX INTEGER (0..4092)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To Vlan-id. Used to specify a range"
DEFVAL { 0 }
::= { rcDiagPcapFilterEntry 11 }
rcDiagPcapFilterIsInverseVlanId OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Vlan-Id Inverse. when set the Vlan-Id
otherthan specified range is matched"
DEFVAL { false }
::= { rcDiagPcapFilterEntry 12 }
rcDiagPcapFilterPbit OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "pBit of the packet to be matched"
DEFVAL { 0 }
::= { rcDiagPcapFilterEntry 13 }
rcDiagPcapFilterToPbit OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To pBit. Used to specify a range"
DEFVAL { 0 }
::= { rcDiagPcapFilterEntry 14 }
rcDiagPcapFilterIsInversePbit OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "pBit Inverse. when set the pBit
otherthan specified range is matched"
DEFVAL { false }
::= { rcDiagPcapFilterEntry 15 }
rcDiagPcapFilterEtherType OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "EtherType of the packet to be matched"
DEFVAL { 0 }
::= { rcDiagPcapFilterEntry 16 }
rcDiagPcapFilterToEtherType OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To EtherType. Used to specify a range"
DEFVAL { 0 }
::= { rcDiagPcapFilterEntry 17 }
rcDiagPcapFilterIsInverseEtherType OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "EtherType Inverse. when set the EtherType
otherthan specified range is matched"
DEFVAL { false }
::= { rcDiagPcapFilterEntry 18 }
rcDiagPcapFilterProtocolType OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "ProtocolType of the packet to be matched"
DEFVAL { 0 }
::= { rcDiagPcapFilterEntry 19 }
rcDiagPcapFilterToProtocolType OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To ProtocolType. Used to specify a range"
DEFVAL { 0 }
::= { rcDiagPcapFilterEntry 20 }
rcDiagPcapFilterIsInverseProtocolType OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "ProtocolType Inverse. when set the ProtocolType
otherthan specified range is matched"
DEFVAL { false }
::= { rcDiagPcapFilterEntry 21 }
rcDiagPcapFilterSrcIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Source IP address of the packet to be matched"
::= { rcDiagPcapFilterEntry 22 }
rcDiagPcapFilterToSrcIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To Source IP address. Used to specify a range"
::= { rcDiagPcapFilterEntry 23 }
rcDiagPcapFilterIsInverseSrcIp OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Source IP address Inverse. when set the source IP
otherthan specified range is matched"
DEFVAL { false }
::= { rcDiagPcapFilterEntry 24 }
rcDiagPcapFilterDstIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Destination IP address of the packet to be matched"
::= { rcDiagPcapFilterEntry 25 }
rcDiagPcapFilterToDstIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To Destination IP address. Used to specify a range"
::= { rcDiagPcapFilterEntry 26 }
rcDiagPcapFilterIsInverseDstIp OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Destination IP address Inverse. when set the
Destination IP other than specified is range
matched"
DEFVAL { false }
::= { rcDiagPcapFilterEntry 27 }
rcDiagPcapFilterDscp OBJECT-TYPE
SYNTAX INTEGER (0..63)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "DSCP value of the packet to be matched"
DEFVAL { 0 }
::= { rcDiagPcapFilterEntry 28 }
rcDiagPcapFilterToDscp OBJECT-TYPE
SYNTAX INTEGER (0..63)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To DSCP. Used to specify a range"
DEFVAL { 0 }
::= { rcDiagPcapFilterEntry 29 }
rcDiagPcapFilterIsInverseDscp OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "DSCP Inverse. when set the DSCP
otherthan specified range is matched"
DEFVAL { false }
::= { rcDiagPcapFilterEntry 30 }
rcDiagPcapFilterRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Row Status"
::= { rcDiagPcapFilterEntry 31 }
rcDiagPcapFilterDscpMatchZero OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "When this value is set to true, then 0 value of
Pbit is not taken as disable value. The user will
be allowed to capture packets with Pbit value of
0 also. Be default it would be set to FALSE"
DEFVAL { false }
::= { rcDiagPcapFilterEntry 32 }
rcDiagPcapFilterPbitMatchZero OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "When this value is set to true, then 0 value of
Pbit is not taken as disable value. The user will
be allowed to capture packets with Pbit value of
0 also. Be default it would be set to FALSE"
DEFVAL { false }
::= { rcDiagPcapFilterEntry 33 }
-- rcDiagPcapAdvancedFilterTable
rcDiagPcapAdvancedFilterTableSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of entries in the
Filter table advanced parameter"
::= { rcDiagPcap 12 }
rcDiagPcapAdvancedFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcDiagPcapAdvancedFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table used to store pcap secondary filters"
::= { rcDiagPcap 13 }
rcDiagPcapAdvancedFilterEntry OBJECT-TYPE
SYNTAX RcDiagPcapAdvancedFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Pcap secondary Advanced filter desc"
INDEX {rcDiagPcapAdvancedFilterId }
::= { rcDiagPcapAdvancedFilterTable 1 }
RcDiagPcapAdvancedFilterEntry ::= SEQUENCE {
rcDiagPcapAdvancedFilterId INTEGER,
rcDiagPcapAdvancedFilterUdpPort INTEGER,
rcDiagPcapAdvancedFilterToUdpPort INTEGER,
rcDiagPcapAdvancedFilterIsInverseUdpPort TruthValue,
rcDiagPcapAdvancedFilterTcpPort INTEGER,
rcDiagPcapAdvancedFilterToTcpPort INTEGER,
rcDiagPcapAdvancedFilterIsInverseTcpPort TruthValue,
rcDiagPcapAdvancedFilterUserDefinedData DisplayString,
rcDiagPcapAdvancedFilterUserDefinedDataSize INTEGER,
rcDiagPcapAdvancedFilterUserDefinedOffset INTEGER,
rcDiagPcapAdvancedFilterIsInverseUserDefined TruthValue,
rcDiagPcapAdvancedFilterTimer INTEGER,
rcDiagPcapAdvancedFilterPacketCount INTEGER,
rcDiagPcapAdvancedFilterRefreshTimer INTEGER,
rcDiagPcapAdvancedFilterRowStatus RowStatus
}
rcDiagPcapAdvancedFilterId OBJECT-TYPE
SYNTAX INTEGER (1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Unique ID that represents the filter"
::= { rcDiagPcapAdvancedFilterEntry 1 }
rcDiagPcapAdvancedFilterUdpPort OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "UdpPort of the packet to be matched"
DEFVAL { 0 }
::= { rcDiagPcapAdvancedFilterEntry 2 }
rcDiagPcapAdvancedFilterToUdpPort OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To UdpPort. Used to specify a range"
DEFVAL { 0 }
::= { rcDiagPcapAdvancedFilterEntry 3 }
rcDiagPcapAdvancedFilterIsInverseUdpPort OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "UdpPort Inverse. when set the UdpPort
otherthan specified range is matched"
DEFVAL { false }
::= { rcDiagPcapAdvancedFilterEntry 4 }
rcDiagPcapAdvancedFilterTcpPort OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "TcpPort of the packet to be matched"
DEFVAL { 0 }
::= { rcDiagPcapAdvancedFilterEntry 5 }
rcDiagPcapAdvancedFilterToTcpPort OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To TcpPort. Used to specify a range"
DEFVAL { 0 }
::= { rcDiagPcapAdvancedFilterEntry 6 }
rcDiagPcapAdvancedFilterIsInverseTcpPort OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "TcpPort Inverse. when set the TcpPort
otherthan specified range is matched"
DEFVAL { false }
::= { rcDiagPcapAdvancedFilterEntry 7 }
rcDiagPcapAdvancedFilterUserDefinedData OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "User defined data to match with the packets received"
DEFVAL { "\0" }
::= { rcDiagPcapAdvancedFilterEntry 8 }
rcDiagPcapAdvancedFilterUserDefinedDataSize OBJECT-TYPE
SYNTAX INTEGER (0..50)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Length of user defined data"
DEFVAL { 0 }
::= { rcDiagPcapAdvancedFilterEntry 9 }
rcDiagPcapAdvancedFilterUserDefinedOffset OBJECT-TYPE
SYNTAX INTEGER (0..9600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Offset from which match has to start"
DEFVAL { 0 }
::= { rcDiagPcapAdvancedFilterEntry 10 }
rcDiagPcapAdvancedFilterIsInverseUserDefined OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "TcpPort Inverse. when set the Userdata
otherthan specified is matched"
DEFVAL { false }
::= { rcDiagPcapAdvancedFilterEntry 11 }
rcDiagPcapAdvancedFilterTimer OBJECT-TYPE
SYNTAX INTEGER (0..3600000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Timer to start the pcap capture window in ms"
DEFVAL { 0 }
::= { rcDiagPcapAdvancedFilterEntry 12 }
rcDiagPcapAdvancedFilterPacketCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Number of packets to be captured before disabling pcap"
DEFVAL { 0 }
::= { rcDiagPcapAdvancedFilterEntry 13 }
rcDiagPcapAdvancedFilterRefreshTimer OBJECT-TYPE
SYNTAX INTEGER (0..3600000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Refresh timer in ms"
DEFVAL { 0 }
::= { rcDiagPcapAdvancedFilterEntry 14 }
rcDiagPcapAdvancedFilterRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION "RowStatus"
::= { rcDiagPcapAdvancedFilterEntry 15 }
rcDiagPcapCopyFileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to indicate the file name. When set, the PCAP
data from PCAP engine RAM is stored into this file
in PCAP engine"
::= { rcDiagPcap 14 }
rcDiagPcapResetStat OBJECT-TYPE
SYNTAX INTEGER {
none(1),
resetStat(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To Reset PCAP statistics"
::= { rcDiagPcap 15 }
rcDiagPcapStatPacketCapacityCount OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Packet Capacity Count"
::= { rcDiagPcap 16 }
rcDiagPcapStatNumberOfPacketsReceived OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of packets received in PCAP engine"
::= { rcDiagPcap 17 }
rcDiagPcapStatNumberOfPacketsAccumulated OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of packets captured in PCAP engine"
::= { rcDiagPcap 18 }
rcDiagPcapStatNumberOfPacketsDroppedInPcapEngine OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of packets dropped in PCAP engine by filters"
::= { rcDiagPcap 19 }
rcDiagPcapStatNumberOfPacketsDroppedInHardware OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of packets dropped in Hardware"
::= { rcDiagPcap 20 }
rcDiagPcapDataValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A true/false value that indicate the return
data whether is valid."
::= { rcDiagPcap 21 }
rcDiagPcapEtherTypeForSvlanLevel OBJECT-TYPE
SYNTAX INTEGER ('05dd'h..'ffff'h)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "EtherType of svlan level."
::= { rcDiagPcap 22 }
END