-- ciscoWanFrConnMIB
|
|
--
|
|
-- September 2002, Subra.Hegde
|
|
--
|
|
-- Copyright (c) 2002 by cisco Systems, Inc.
|
|
-- All rights reserved.
|
|
-- *****************************************************************
|
|
|
|
CISCO-WAN-FR-CONN-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Counter32,
|
|
Integer32
|
|
FROM SNMPv2-SMI
|
|
TruthValue FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP FROM SNMPv2-CONF
|
|
frChan, frameRelay FROM BASIS-MIB
|
|
ciscoWan FROM CISCOWAN-SMI;
|
|
|
|
ciscoWanFrConnMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200209180000Z"
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
CONTACT-INFO
|
|
" Cisco Systems
|
|
Customer Service
|
|
|
|
Postal: 170 W Tasman Drive
|
|
San Jose, CA 95134
|
|
USA
|
|
|
|
Tel: +1 800 553-NETS
|
|
|
|
E-mail: cs-wanatm@cisco.com"
|
|
DESCRIPTION
|
|
"The MIB module to configure the Frame Relay
|
|
connection configuration.
|
|
|
|
Terminologies Used:
|
|
|
|
SIW - Frame-Relay-to ATM Service Interworking.
|
|
In SIW, the ATM port connected to a frame
|
|
relay port does not need to be aware that
|
|
it is connected to an interworking function.
|
|
|
|
This is explained in document FRF.8.
|
|
|
|
NIW - Frame-Relay-to ATM Network Interworking.
|
|
In NIW, the ATM port connected to a frame
|
|
relay port does need to be aware that
|
|
it is connected to an interworking function.
|
|
|
|
PVC - Permanent Virtual Circuit OR
|
|
Permanent Virtual Connection
|
|
|
|
A frame relay logical link, whose endpoints
|
|
and class of service are defined by network
|
|
management. A PVC consists of the originating
|
|
frame relay network element address, originating
|
|
DLCI, terminating frame relay network element
|
|
address and terminating DLCI.
|
|
|
|
This is controlled by PAR(Portable Auto Route)
|
|
controller.
|
|
|
|
|
|
SPVC - Soft Permanent Virtual Circuits.
|
|
This is a PVC controlled by PNNI Controller.
|
|
|
|
Frame Relay PVC/SPVC end-point/Channel is referred to as
|
|
frame Relay connection in this MIB.
|
|
|
|
Traffic shaping parameters:
|
|
CIR, EIR, Bc, Be, DE, Tc, AR corresponding to
|
|
rate of the physical interface.
|
|
|
|
CIR - Committed Information Rate.
|
|
|
|
This is the rate of traffic that the PVC
|
|
will support as 'comitted' traffic.
|
|
|
|
The committed rate(in bits per second) at which
|
|
the ingress access interface trunk interfaces,
|
|
and egress access interface of a frame relay
|
|
network transfer information to the destination
|
|
frame relay end system under normal conditions.
|
|
The rate is averaged over a minimum time interval
|
|
Tc.
|
|
|
|
AR - Access Rate
|
|
The maximum number of bits per second that an end
|
|
station can transmit into the network is
|
|
bounded by the acess rate of the user-network
|
|
interface. The line speed of the user network
|
|
connection limits the access rate.
|
|
|
|
Bc - Committed Burst Size
|
|
The maximum amount of data(in bits) that the
|
|
network agrees to transfer, under normal conditions
|
|
during a time interval Tc.
|
|
The data is in bytes in the current implementation.
|
|
|
|
Be - Excess Burst Size
|
|
The maximum amount of uncommitted data(in bits)
|
|
in excess of BC that a frame relay network can
|
|
attempt to deliver during a time interval Tc.
|
|
This data generally is delivered with a low
|
|
probability than Bc. The network treats Be
|
|
data as discard eligible.
|
|
The data is in bytes in the current implementation.
|
|
|
|
Tc - The committed rate measurement interval.
|
|
The time interval during which the user can send
|
|
only BC committed amount of data and BE excess
|
|
amount of data.
|
|
|
|
EIR - Excess Information Rate
|
|
This is the bandwidth in excess of CIR
|
|
the PVC will be allowed to burst on a
|
|
a given PVC.
|
|
|
|
The average rate at which excess traffic is
|
|
to be policed. This number is computed based
|
|
on Bc, Be, CIR and Tc.
|
|
|
|
DE - Discard Eligibility
|
|
|
|
|
|
Frame Forwarding Port: Frame Forwarding Ports are identified
|
|
by portType = frame-forward(3).
|
|
|
|
NOTE: The objects related to frame relay ports are
|
|
available in ifTable,if ifTable is implemented
|
|
in service module/card.
|
|
|
|
Following Service Modules support ifTable:
|
|
FRSM-12
|
|
"
|
|
|
|
REVISION "200209180000Z"
|
|
DESCRIPTION
|
|
"Initial version of the MIB.
|
|
|
|
The content of this MIB was originally available
|
|
in CISCO-WAN-AXIPOP-MIB defined using SMIv1.
|
|
The applicable objects from CISCO-WAN-AXIPOP-MIB
|
|
are defined using SMIv2 in this MIB. Also the
|
|
descriptions of some of the objects have been
|
|
modified."
|
|
|
|
::= { ciscoWan 47 }
|
|
|
|
|
|
frChanCnfGrp OBJECT IDENTIFIER ::= { frChan 1 }
|
|
|
|
|
|
-- ------------------------------------------------------------------------
|
|
--
|
|
-- frChannelConfig group
|
|
-- Channel configurable parameters (VC)
|
|
--
|
|
-- ------------------------------------------------------------------------
|
|
|
|
|
|
frChanCnfGrpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrChanCnfGrpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is for configuring connection
|
|
parameters for frame relay connections."
|
|
::= { frChanCnfGrp 1 }
|
|
|
|
frChanCnfGrpEntry OBJECT-TYPE
|
|
SYNTAX FrChanCnfGrpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry for each frame relay connection."
|
|
INDEX { chanNum }
|
|
::= { frChanCnfGrpTable 1 }
|
|
|
|
FrChanCnfGrpEntry ::=
|
|
SEQUENCE {
|
|
chanNum Integer32,
|
|
chanRowStatus INTEGER,
|
|
chanPortNum Integer32,
|
|
dLCI Integer32,
|
|
egressQSelect INTEGER,
|
|
ingressQDepth Integer32,
|
|
ingressQDEThresh Integer32,
|
|
ingressQECNThresh Integer32,
|
|
egressQDepth Integer32,
|
|
egressQDEThresh Integer32,
|
|
egressQECNThresh Integer32,
|
|
deTaggingEnable INTEGER,
|
|
cir Integer32,
|
|
bc Integer32,
|
|
be Integer32,
|
|
ibs Integer32,
|
|
foreSightEnable INTEGER,
|
|
qir Integer32,
|
|
mir Integer32,
|
|
pir Integer32,
|
|
chanLocRmtLpbkState INTEGER,
|
|
chanTestType INTEGER,
|
|
chanTestState INTEGER,
|
|
chanRTDResult Integer32,
|
|
chanType INTEGER,
|
|
chanFECNconfig INTEGER,
|
|
chanDEtoCLPmap INTEGER,
|
|
chanCLPtoDEmap INTEGER,
|
|
-- CAC parameters (IngrPcr will be derived from foresightPIR )
|
|
chanIngrPercentUtil Integer32,
|
|
chanEgrPercentUtil Integer32,
|
|
chanEgrSrvRate Integer32,
|
|
chanOvrSubOvrRide INTEGER,
|
|
chanFrConnType INTEGER,
|
|
frCDRNumber Integer32,
|
|
-- Connection parameters, used by PXM
|
|
frLocalVpi Integer32,
|
|
frLocalVci Integer32,
|
|
frLocalNSAP OCTET STRING,
|
|
frRemoteVpi Integer32,
|
|
frRemoteVci Integer32,
|
|
frRemoteNSAP OCTET STRING,
|
|
frMastership INTEGER,
|
|
frVpcFlag INTEGER,
|
|
frConnServiceType INTEGER,
|
|
frRoutingPriority Integer32,
|
|
frMaxCost Integer32,
|
|
frRestrictTrunkType INTEGER,
|
|
frConnPCR Integer32,
|
|
frConnRemotePCR Integer32,
|
|
frConnMCR Integer32,
|
|
frConnRemoteMCR Integer32,
|
|
frConnPercentUtil Integer32,
|
|
frConnRemotePercentUtil Integer32,
|
|
frConnForeSightEnable INTEGER,
|
|
frConnFGCRAEnable INTEGER,
|
|
chanServType INTEGER,
|
|
chanServiceRateOverride INTEGER,
|
|
chanServiceRate Integer32,
|
|
zeroCirConEir Integer32,
|
|
chanReroute INTEGER,
|
|
frConnSCR Integer32,
|
|
frConnRemoteSCR Integer32,
|
|
frConnTemplateId Integer32,
|
|
frConnAdminStatus INTEGER,
|
|
frChanCnfChangeCount Counter32,
|
|
frChanCnfIgnoreIncomingDE INTEGER,
|
|
frChanOamCCEnable INTEGER,
|
|
frChanStatsEnable INTEGER,
|
|
frChanLocalLpbkEnable INTEGER,
|
|
frChanUpcEnable INTEGER,
|
|
frChanSlaveType INTEGER,
|
|
frConnRemoteMBS Integer32,
|
|
frChanPrefRouteId Integer32,
|
|
frChanDirectRoute TruthValue
|
|
|
|
}
|
|
|
|
chanNum OBJECT-TYPE
|
|
SYNTAX Integer32(1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies the
|
|
frame relay connection/channel index.
|
|
|
|
Note that the actual range of the index
|
|
supported by a card depends on the type of card.
|
|
|
|
Supported Range for different Card Types:
|
|
|
|
FRSM-4T1/E1 : Range is 16..271 (256 entries)
|
|
FRSM-8T1/E1 : Range is 16..1015 (1000 entries)
|
|
FRSM-T3/E3/HS2/
|
|
/HS2B-HSSI/T3B/E3B : Range is 16..2015 (2000 entries)
|
|
FRSM-2CT3/HS2B-12IN1: Range is 16..4015 (4000 entries)
|
|
|
|
For FRSM12 Card : Range is 16..16015 for Lower 16 bits
|
|
Upper 16 bits contain Chassis Number
|
|
and logical slot number."
|
|
::= { frChanCnfGrpEntry 1}
|
|
|
|
chanRowStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
add(1),
|
|
del(2),
|
|
mod(3),
|
|
outOfService(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used for adding/modifying/deleting
|
|
the channel.
|
|
add(1) : For adding the frame relay connections.
|
|
delete(2): For deleting frame relay connections.
|
|
mod(3) : For Modifying frame relay connections.
|
|
This is also used for uping the connection.
|
|
|
|
outOfService(4) : Bring the Frame relay connection
|
|
down."
|
|
::= { frChanCnfGrpEntry 2 }
|
|
|
|
chanPortNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object refers to the frame relay
|
|
port on which channel is created.
|
|
This is a mandatory object for creating the channel.
|
|
|
|
For FRSM12 Card:
|
|
This object contains the port's ifIndex value.
|
|
"
|
|
::= { frChanCnfGrpEntry 3 }
|
|
|
|
dLCI OBJECT-TYPE
|
|
SYNTAX Integer32 (0..8388607)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is the DLCI number of the channel.
|
|
|
|
This is a mandatory object for creating the channel.
|
|
|
|
All the connections on the same port should have
|
|
a unique DLCI number.
|
|
|
|
Note that if we are adding a channel to a port that
|
|
has LMI signalling enabled, then we can not use DLCI
|
|
number 0(ANNEX A & D) and 1023(STRATA LMI).
|
|
|
|
The value of this object can be only 1000 if
|
|
the portType = frame-forward(3) on which the frame relay
|
|
connection is being created. That is, only one Frame Relay
|
|
Connection can be created on a Frame Forwarding Port.
|
|
|
|
For portHeaderLen = twoOctets(1) following restrictions apply.
|
|
Range supported is '0..1023'
|
|
DLCI values 0,1007, 1023 can not be used.
|
|
|
|
For portHeaderLen = fourOctets(2) following restrictions apply.
|
|
Range supported is '0..8388607'
|
|
DLCI values 0,8257535 can not be used.
|
|
"
|
|
::= { frChanCnfGrpEntry 4}
|
|
|
|
egressQSelect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
highPriority(1),
|
|
lowPriority(2),
|
|
notSupported(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects one out of two possible port queues.
|
|
The default port queue number is 1 which is the high
|
|
pririty queue.
|
|
1 = High priority queue
|
|
2 = Low priority queue
|
|
3 = Indicates that this entry is not used (eg: in FRSM-VHS,
|
|
chanServType indicates the channel service type and
|
|
would determine the queue to which the channel gets mapped)
|
|
For FRSM12 Card:
|
|
This object is used to select between the two ATM-COS queues
|
|
in the egress direction.
|
|
"
|
|
DEFVAL { lowPriority }
|
|
::= { frChanCnfGrpEntry 5}
|
|
|
|
ingressQDepth OBJECT-TYPE
|
|
SYNTAX Integer32 (4510..'1fffff'h)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable sets the max depth for queue, before
|
|
it starts dropping the cells. It is defined in
|
|
terms of number of bytes.
|
|
In all cards except the FRSM-VHS card, the range is
|
|
limited to (4510..'ffff'h).
|
|
|
|
ingressQDepth should be greater than ingressQECNThresh
|
|
and ingressQDEThresh
|
|
For FRSM12 Card: Not Supported
|
|
"
|
|
DEFVAL { 65535 }
|
|
::= { frChanCnfGrpEntry 6}
|
|
|
|
ingressQECNThresh OBJECT-TYPE
|
|
SYNTAX Integer32 (0..'1fffff'h)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable sets the max depth for queue, before
|
|
it starts flow control. It is defined in terms of
|
|
number of bytes.
|
|
In all cards except the FRSM-VHS card, the range is
|
|
limited to (0..'ffff'h).
|
|
For FRSM12 Card: Not Supported
|
|
"
|
|
DEFVAL { 6553 }
|
|
::= { frChanCnfGrpEntry 7}
|
|
|
|
ingressQDEThresh OBJECT-TYPE
|
|
SYNTAX Integer32 (0..'1fffff'h)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable sets the max depth for queue, before
|
|
they become discard eligible. It is defined in terms of
|
|
number of bytes.
|
|
In all cards except the FRSM-VHS card, the range is
|
|
limited to (0..'ffff'h).
|
|
For FRSM12 Card: Not Supported
|
|
"
|
|
DEFVAL { 32767 }
|
|
::= { frChanCnfGrpEntry 8}
|
|
|
|
egressQDepth OBJECT-TYPE
|
|
SYNTAX Integer32 (0..'1fffff'h)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable sets the max depth for queue, before
|
|
it starts dropping the cells. It is defined in terms of
|
|
number of bytes.
|
|
In all cards except the FRSM-VHS card, the range is
|
|
limited to (0..'ffff'h).
|
|
|
|
egressQDepth should be greater than egressQDEThresh
|
|
and egressQECNThresh
|
|
|
|
For FRSM12 Card: Not Supported
|
|
"
|
|
DEFVAL { 65535 }
|
|
::= { frChanCnfGrpEntry 9}
|
|
|
|
egressQDEThresh OBJECT-TYPE
|
|
SYNTAX Integer32 (0..'1fffff'h)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable sets the max depth for queue, before
|
|
they become discard eligible. It is defined in terms of
|
|
number of bytes.
|
|
In all cards except the FRSM-VHS card, the range is
|
|
limited to (0..'ffff'h).
|
|
|
|
For FRSM12 Card: Not Supported
|
|
"
|
|
DEFVAL { 32767 }
|
|
::= { frChanCnfGrpEntry 10}
|
|
|
|
egressQECNThresh OBJECT-TYPE
|
|
SYNTAX Integer32 (0..'1fffff'h)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable sets the max depth for queue, before
|
|
it starts flow control. It is defined in terms of
|
|
number of bytes.
|
|
In all cards except the FRSM-VHS card, the range is
|
|
limited to (0..'ffff'h).
|
|
For FRSM12 Card: Not Supported
|
|
"
|
|
DEFVAL { 6553 }
|
|
::= { frChanCnfGrpEntry 11}
|
|
|
|
deTaggingEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables/disables the DE tagging.
|
|
The tagging is enabled only in the ingress
|
|
direction.
|
|
|
|
For FRSM12 Card:
|
|
When this object is disabled, the ingress policer will never
|
|
set the DE bit to 1 in the Frame Relay frames even if
|
|
the incoming frame exceeds the Bc bucket.
|
|
"
|
|
DEFVAL { disable }
|
|
::= { frChanCnfGrpEntry 12}
|
|
|
|
cir OBJECT-TYPE
|
|
SYNTAX Integer32 (0..52000000)
|
|
UNITS "bps"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is equal to the CIR parameter
|
|
for this frame relay connection.
|
|
|
|
The CIR value have to be less than or equal to the port speed.
|
|
Any value from 1 to 2399 will be rounded off to 2400.
|
|
|
|
Range supported for different interfaces/card:
|
|
|
|
For E1 interface : Range is 0..2048000
|
|
For T1 interface : Range is 0..1536000
|
|
For E3 interface : Range is 0..34368000
|
|
For T3 interface : Range is 0..44736000
|
|
For HSSI : Range is 0..52000000
|
|
For FRSM-2CT3 : Range is 0..1536000
|
|
For FRSM-HS2B-12IN1: Range is 0..10240000
|
|
|
|
The CIR value can be 0 only for chanServType = uBR(5).
|
|
"
|
|
DEFVAL { 2400 }
|
|
::= { frChanCnfGrpEntry 13}
|
|
|
|
bc OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2097151)
|
|
UNITS "bytes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is equal to the
|
|
committed burst size(BC) parameter for this
|
|
PVC endpoint.
|
|
|
|
The value of bc can not be 0 when cir is non zero.
|
|
The value of bc has to be 0 if cir is 0.
|
|
|
|
The peak value for bc in FRSM-VHS cards is (2^21 -1),
|
|
i.e. 2097151 and for all other cards, it is 65535.
|
|
For FRSM-VHS cards, the relation between CIR and Bc should
|
|
be such that Tc is always less than 512 seconds.
|
|
"
|
|
DEFVAL { 5100 }
|
|
::= { frChanCnfGrpEntry 14}
|
|
|
|
be OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2097151)
|
|
UNITS "bytes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is euqal to the
|
|
excess burst size(Be) parameter for this PVC
|
|
endpoint.
|
|
|
|
The value be can not be 0 when cir is 0.
|
|
|
|
The peak value for be :
|
|
For FRSM-VHS and FRSM12 cards is (2^21 -1), i.e. 2097151 and
|
|
For all other cards, it is 65535.
|
|
|
|
For FRSM-VHS cards, setting the value of 2091751 will
|
|
cause the policing to be disabled. "
|
|
DEFVAL { 5100 }
|
|
::= { frChanCnfGrpEntry 15}
|
|
|
|
ibs OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2097151)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is euqal to the
|
|
excess burst size(Be) parameter for this PVC
|
|
endpoint.
|
|
|
|
The value of ibs should be less or equal to bc
|
|
when cir is greater than 0.
|
|
|
|
The value of ibs has to be 0 when cir is 0.
|
|
|
|
The peak value for ibs in FRSM-VHS cards is (2^21 -1),
|
|
i.e. 2097151 and for all other cards, it is 65535.
|
|
|
|
For FRSM12 Card: Not Supported
|
|
"
|
|
DEFVAL { 100 }
|
|
::= { frChanCnfGrpEntry 16}
|
|
|
|
foreSightEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable enables/disables foreSight option.
|
|
|
|
Following objects can be modified only when this
|
|
object is set to enable(1):
|
|
|
|
qir, mir, pir
|
|
|
|
The RATE CONTROL FEATURE has to be ON in order to enable
|
|
foresight and also modify its parameter.
|
|
|
|
For FRSM12 Card: Not Supported
|
|
"
|
|
DEFVAL { disable }
|
|
::= { frChanCnfGrpEntry 17}
|
|
|
|
qir OBJECT-TYPE
|
|
SYNTAX Integer32 (160..6400000)
|
|
UNITS "fastpackets-per-second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is euqal to the
|
|
quiescent information rate for Foresight.
|
|
|
|
The unit is 1 Cell/Sec = 16 fastpackets/sec.
|
|
|
|
Following information about cps is for reference only:
|
|
The peak value for qir in FRSM-VHS cards is 285714 cps and
|
|
for all other cards, it is 10000 cps.
|
|
For FRSM-VHS cards, cell will be the ATM cell (48 byte payload).
|
|
|
|
For FRSM12 Card: Not Supported"
|
|
DEFVAL { 160 }
|
|
::= { frChanCnfGrpEntry 18}
|
|
|
|
mir OBJECT-TYPE
|
|
SYNTAX Integer32 (160..6400000)
|
|
UNITS "fastpackets-per-second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is euqal to the
|
|
minimum information rate for Foresight.
|
|
|
|
The unit is 1 Cell/Sec = 16 fastpackets/sec.
|
|
is equal to 16 fastpackets/sec.
|
|
|
|
Following information about cps is for reference only:
|
|
The peak value for qir in FRSM-VHS cards is 285714 cps and
|
|
for all other cards, it is 10000 cps.
|
|
For FRSM-VHS cards, cell will be the ATM cell (48 byte payload).
|
|
|
|
For FRSM12 Card: Not Supported
|
|
"
|
|
DEFVAL { 160 }
|
|
::= { frChanCnfGrpEntry 19}
|
|
|
|
pir OBJECT-TYPE
|
|
SYNTAX Integer32 (160..6400000)
|
|
UNITS "fastpackets-per-second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is euqal to the
|
|
peak information rate for Foresight.
|
|
|
|
The unit is 1 Cell/Sec = 16 fastpackets/sec.
|
|
is equal to 16 fastpackets/sec.
|
|
|
|
Following information about cps is for reference only:
|
|
The peak value for qir in FRSM-VHS cards is 285714 cps and
|
|
for all other cards, it is 10000 cps.
|
|
For FRSM-VHS cards, cell will be the ATM cell (48 byte payload).
|
|
|
|
For FRSM12 Card: Not Supported
|
|
"
|
|
DEFVAL { 160 }
|
|
::= { frChanCnfGrpEntry 20}
|
|
|
|
|
|
chanLocRmtLpbkState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable enables or disables the remote loopback for each
|
|
channel.
|
|
When you enable this option on a connection (channel) then all the
|
|
cells that are coming from the network side would be looped back
|
|
toward the network and all the frames coming from the user side
|
|
would be dropped.
|
|
This channel remote loopback has nothing to do with the chanTestType
|
|
option, each one does a different function.
|
|
For example, the channel remote loopback is used for looping the data
|
|
toward the network and if this connection is terminated on an IPX
|
|
then they can put a test equipment and measure some of the
|
|
characteristics of the network.
|
|
|
|
For FRSM12 Card: Not Supported
|
|
"
|
|
DEFVAL { disable }
|
|
::= { frChanCnfGrpEntry 21}
|
|
|
|
chanTestType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testcon(1),
|
|
testdelay(2),
|
|
notest(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The chanTestType starts testing the continuity
|
|
or delay of a connection.
|
|
It sends specific cell patterns toward the network
|
|
and the terminating end of this connection has to be an
|
|
MGX8220 or ASI of a BPX in order for this test to be working.
|
|
|
|
The receiving node would loop back when it receives these
|
|
cells. The test should be done in about couple of seconds.
|
|
The testcon tests the continuity of the connection and
|
|
testdelay uses the same test except that it measures for
|
|
delay through the network.
|
|
To test the delay follow this procedure:
|
|
a- set chanTestType to testdelay
|
|
b- read chanTestState till it is Pass or Fail
|
|
c- Read chanRTDResult for the delay if it is Pass
|
|
*Note that the chanTestType would go back to notest when the
|
|
test is completed
|
|
To test the continuity follow this procedure:
|
|
a- set chanTestType to testcon
|
|
b- read chanTestState till it is Pass or Fail
|
|
*Note that the chanTestType would go back to notest when the
|
|
test is completed
|
|
You CAN NOT select 2 tests back to back,
|
|
you have to select one and wait for
|
|
the result and then start the other one.
|
|
SYNTAX
|
|
When you select testdelay
|
|
|
|
This is the type of the test
|
|
1 = Test Continuity
|
|
2 = Test Delay
|
|
3 = No Test
|
|
"
|
|
DEFVAL { notest }
|
|
::= { frChanCnfGrpEntry 22}
|
|
|
|
chanTestState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
passed(1),
|
|
failed(2),
|
|
inprogress(3),
|
|
notinprogress(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This shows the state of the test
|
|
When you add a connection then the chanTestState becomes notinprogress
|
|
and when you select any test, it would go to inprogress state and after
|
|
it completes the test, it will go to failed or passed state.
|
|
1 = Passed
|
|
2 = Failed
|
|
3 = In Progress
|
|
4 = Not In Progress
|
|
"
|
|
DEFVAL { notinprogress }
|
|
::= { frChanCnfGrpEntry 23}
|
|
|
|
chanRTDResult OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is round trip delay in milliseconds.
|
|
When you select testdelay option for the chanTestType, the result of
|
|
the test that is measured in milliseconds can be read in chanRTDResult.
|
|
"
|
|
DEFVAL { 65535 }
|
|
::= { frChanCnfGrpEntry 24}
|
|
|
|
chanType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
frNIW(1),
|
|
frSIW-transparent(2),
|
|
frSIW-translate(3),
|
|
frFUNI(4),
|
|
frForward(5),
|
|
frNIWReplace(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is used for setting the
|
|
channel type of a frame relay connection. If set
|
|
with values frSIW-transparent(2) and frSIW-translate(3),
|
|
all PVC data is subject to service interworking translation
|
|
and mapping in both Frame Relay-to-ATM and ATM-to-Frame relay
|
|
directions.
|
|
|
|
The possible values are :
|
|
|
|
frNIW(1) : Frame-Relay-to ATM Network
|
|
Interworking(NIW-unicast).
|
|
The traffic crosses the network as
|
|
ATM Cells.
|
|
|
|
frSIW-transparent(2): Service InterWorking with out any
|
|
SDU translation. In transparent mode,
|
|
the service module does not translate.
|
|
|
|
frSIW-translate(3) : Service InterWorking with SDU translation.
|
|
In translation mode, service module
|
|
translates protocol between the FR NLPID
|
|
encapsulation(RFC 1490) and ATM LCC
|
|
encapsulation(RFC 1483). Translation mode
|
|
support includes address resolution by
|
|
transforming address resolution protocol
|
|
(ARP, RFC 826) and inverse ARP(RFC 1293)
|
|
between the frame relay and ATM Formats.
|
|
|
|
frFUNI(4) : Frame based UNI: mode-1a which is ALL5.
|
|
|
|
frForward(5) : frame forwarding. Frame forwarding operates
|
|
same as standard frame relay except:
|
|
* 2 byte Q.922 header is not assumed
|
|
or interpreted.
|
|
* All frames received are mapped to a
|
|
specific connection if it exists. Otherwise
|
|
the frames are dropped.
|
|
* No DE/CLP or FECN/EFCI mapping is performed.
|
|
* 'llegal Header count' and 'invalid DLCI'
|
|
statistics are not kept/applicable.
|
|
|
|
frNIWReplace(6) : Frame Relay network interworking
|
|
with DLCI in FR-SSCS(Frame Relay Specific
|
|
Convergence Sublayer)PDU always
|
|
set to 1022.
|
|
"
|
|
REFERENCE
|
|
"FRF.8"
|
|
::= { frChanCnfGrpEntry 25 }
|
|
|
|
chanFECNconfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
mapEFCI(1),
|
|
setEFCIzero(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object specifies how to map
|
|
from FECN field in the frame Relay PDU to
|
|
the EFCI field in the ATM cells.
|
|
|
|
This object does not apply to NIW.
|
|
This is applicable only
|
|
for SIW.
|
|
|
|
mapEFCI(1) : Maps the FECN bits in frame-relay
|
|
to EFCI bit in the ATM cells.
|
|
This value is valid only for SIW.
|
|
setEFCIzero(2): Set EFCI = 0. Do not map FECN to EFCI."
|
|
REFERENCE
|
|
"FRF.8, section 4.3.1.1"
|
|
::= { frChanCnfGrpEntry 26 }
|
|
|
|
chanDEtoCLPmap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
mapCLP(1),
|
|
setCLPzero(2),
|
|
setCLPone(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object specifies how to map
|
|
from DE bit on the Frame Relay side to CLP
|
|
bit on the ATM side.
|
|
|
|
mapCLP(1) : Map DE bit to CLP bit in ATM cell.
|
|
setCLPzero(2) : Ignore DE bit. Set CLP to 0.
|
|
setCLPone(3) : Ignore DE bit. Set CLP to 1.
|
|
For FRSM12 Card:
|
|
Should not be mapCLP for chanType of frForward.
|
|
"
|
|
REFERENCE
|
|
"FRF.5, FRF.8"
|
|
::= { frChanCnfGrpEntry 27 }
|
|
|
|
chanCLPtoDEmap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
mapDE(1),
|
|
setDEzero(2),
|
|
setDEone(3),
|
|
ignoreCLP(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object enables mapping of
|
|
Cell Loss Priority(CLP) bit on the ATM Side
|
|
to Discard Eligibility(DE) bit on the Frame relay
|
|
side.
|
|
|
|
The possible values are :
|
|
|
|
mapDE(1) : Map CLP bit to DE bit.
|
|
Valid for SIW and NIW.
|
|
|
|
setDEzero(2) : Ignore CLP. Set DE bit to 0.
|
|
Valid for SIW.
|
|
|
|
setDEone(3) : Ignore CLP. Set DE bit to 1.
|
|
Valid for SIW.
|
|
|
|
ignoreCLP(4) : Ignore CLP. No change in receieved DE bit.
|
|
Valid for NIW.
|
|
|
|
For FRSM12 Card:
|
|
Should be ignoreCLP for chanType of frForward.
|
|
Should not be setDEzero/setDEone for chanType of frNIW
|
|
and frNIWReplace.
|
|
Should not be ignoreCLP for chanType of frSIW-transparent
|
|
and frSIW-translate.
|
|
"
|
|
REFERENCE
|
|
"FRF.8, section 4.2.2
|
|
FRF.5, section 4.4.2"
|
|
::= { frChanCnfGrpEntry 28 }
|
|
|
|
chanIngrPercentUtil OBJECT-TYPE
|
|
SYNTAX Integer32 (1..100)
|
|
UNITS "percentage"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ingress utilization on a
|
|
frame relay connection."
|
|
DEFVAL { 100 }
|
|
::= { frChanCnfGrpEntry 29 }
|
|
|
|
chanEgrPercentUtil OBJECT-TYPE
|
|
SYNTAX Integer32 (1..100)
|
|
UNITS "percentage"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The egress utilization on a
|
|
frame relay connection."
|
|
DEFVAL { 100 }
|
|
::= { frChanCnfGrpEntry 30 }
|
|
|
|
chanEgrSrvRate OBJECT-TYPE
|
|
SYNTAX Integer32 (2400..52000000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies egress CIR
|
|
value for a frame relay connection.
|
|
|
|
The value of this object must be less than or equal(<=)
|
|
to the port speed.
|
|
|
|
The value supported depends upon the interface
|
|
and service module(card) type.
|
|
|
|
For E1 Service Module : Range is 2400..2048000
|
|
For T1 Service Module : Range is 2400..1536000
|
|
2CT3 Module :
|
|
For E3 Service Module : Range is 2400..34368000
|
|
For T3 Service Module : Range is 2400..44736000
|
|
For HSSI Service Module : Range is 2400..52000000
|
|
|
|
For FRSM12 Card:
|
|
This object is used only for CAC and the range will be same
|
|
as the range for cir object. The Maximum value is 44736000m.
|
|
"
|
|
DEFVAL { 2400 }
|
|
::= { frChanCnfGrpEntry 31 }
|
|
|
|
chanOvrSubOvrRide OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object enables/disables the
|
|
oversubscription on a connection.
|
|
This object allows one to add a new connection on a port
|
|
even if it is over subscribed.
|
|
|
|
For FRSM12 Card: Not Supported."
|
|
DEFVAL { disable }
|
|
::= { frChanCnfGrpEntry 32 }
|
|
|
|
chanFrConnType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pvc(1),
|
|
svc(2),
|
|
spvc(3),
|
|
par(4),
|
|
pnni(5),
|
|
tag(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is used for configuring
|
|
connection type of a frame relay connection.
|
|
|
|
The possible values are :
|
|
|
|
pvc(1) : Permanent Virtual Connection
|
|
svc(2) : Switched Virtual Connection
|
|
spvc(3) : Soft PVC.
|
|
par(4) : Portable Auto Route Connection.
|
|
Valid only for trunk connection
|
|
pnni(5) : PNNI Connection
|
|
Valid only for trunk connection
|
|
tag(6) : Tag/MPLS Connection
|
|
Valid only for trunk connection
|
|
For FRSM12 Card: Not Supported."
|
|
DEFVAL { pvc }
|
|
::= { frChanCnfGrpEntry 33 }
|
|
|
|
frCDRNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies
|
|
the CDR(Call Detail Record) number.
|
|
This is the key to correlate
|
|
cell/frame counts, start/end record.
|
|
|
|
For FRSM12 Card: Not Supported
|
|
"
|
|
::= { frChanCnfGrpEntry 34 }
|
|
|
|
frLocalVpi OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object provides the VPI
|
|
value for the local endpoint.
|
|
This object in conjunction with frLocalVci and
|
|
frLocalNSAP represents the local end point of
|
|
this connection.
|
|
|
|
The service module sets this to value 0."
|
|
::= { frChanCnfGrpEntry 35 }
|
|
|
|
frLocalVci OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object provides the VCI
|
|
value for the local endpoint.
|
|
This object in conjunction with frLocalVpi and
|
|
frLocalNSAP represents the local end point of
|
|
this connection.
|
|
|
|
The service module assigns this value
|
|
specified in object 'dLCI'."
|
|
::= { frChanCnfGrpEntry 36 }
|
|
|
|
frLocalNSAP OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..20))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies the
|
|
NSAP address of the frame relay connection.
|
|
|
|
The value of this object follows the format:
|
|
Prefix : 13 Bytes
|
|
Cisco ID : 2 bytes
|
|
Reserved : 1 byte
|
|
Slot Number : 1 byte
|
|
Port Number : 2 bytes
|
|
ESL : 1 byte
|
|
|
|
For FRSM12 Card:
|
|
This object will have the NSAP format as required by the
|
|
PNNI controller
|
|
"
|
|
::= { frChanCnfGrpEntry 37 }
|
|
|
|
frRemoteVpi OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies the VPI value of remote
|
|
end point of this connection. The frRemoteVpi, frRemoteVci
|
|
and frRemoteNSAP identifies the remote end point of
|
|
this connection."
|
|
::= { frChanCnfGrpEntry 38 }
|
|
|
|
frRemoteVci OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies the VCI value of remote
|
|
end point of this connection. The frRemoteVpi, frRemoteVci
|
|
and frRemoteNSAP identifies the remote end point of
|
|
this connection."
|
|
::= { frChanCnfGrpEntry 39 }
|
|
|
|
frRemoteNSAP OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..20))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies the
|
|
NSAP address of the frame relay connection.
|
|
|
|
The value of this object follows the format:
|
|
|
|
Prefix : 13 Bytes
|
|
Cisco ID : 2 bytes
|
|
Reserved : 1 byte
|
|
Slot Number : 1 byte
|
|
Port Number : 2 bytes
|
|
ESL : 1 byte."
|
|
::= { frChanCnfGrpEntry 40 }
|
|
|
|
frMastership OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
master (1),
|
|
slave (2),
|
|
unknown (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This is used by PXM to determine if this end point is
|
|
master or slave, a new type unknown is added to identify
|
|
the SM in MGX8220 shelf and the SM in MGX shelf. In AXIS
|
|
shelf, user can still use addchan to add a channel without
|
|
specifying X/Y/P parameters. But in MGX shelf, if the
|
|
user uses addchan without X/Y/P set (based on this object
|
|
being set to type 3 unknown), SPM on PXM will reject
|
|
the request. It must be supplied in connection setup request.
|
|
In the feeder mode, this is always set to master.
|
|
"
|
|
::= { frChanCnfGrpEntry 41 }
|
|
|
|
frVpcFlag OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
vpc (1),
|
|
vcc (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This represents the connection type, used for PXM to
|
|
identify VPC/VCC but FRSM card doesn't use it
|
|
always set to vcc for FRSM card
|
|
For FRSM12 Card:
|
|
For chanFrConnType = pnni(5), this object is
|
|
set to vcc(2) always."
|
|
DEFVAL { vcc }
|
|
::= { frChanCnfGrpEntry 42 }
|
|
|
|
frConnServiceType OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
cbr (1),
|
|
vbr (2),
|
|
notUsed (3),
|
|
ubr (4),
|
|
atfr (5),
|
|
abrstd (6),
|
|
abrfst (7),
|
|
vbrrt (8),
|
|
cbr1 (21),
|
|
vbr1rt (22),
|
|
vbr2rt (23),
|
|
vbr3rt (24),
|
|
vbr1nrt(25),
|
|
vbr2nrt(26),
|
|
vbr3nrt(27),
|
|
ubr1 (28),
|
|
ubr2 (29),
|
|
stdabr (30),
|
|
cbr2 (31),
|
|
cbr3 (32)
|
|
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This specifies the service type
|
|
1 ==> Constant Bit Rate
|
|
2 ==> Variable Bit Rate
|
|
3 ==> Not used
|
|
4 ==> Unspecified Bit Rate
|
|
5 ==> ATM frame relay
|
|
6 ==> standard ABR
|
|
7 ==> foresight ABR
|
|
Note that this is used by PXM card, SV+ doesn't need to set it,
|
|
if not set in the connection setup request, it'll be defaulted
|
|
to ATFR type for FRSM.
|
|
Also to make it compatible with existing AUSM MIB definition,
|
|
value 3 is not used.
|
|
The following types are being added for PNNI support.
|
|
and are based on UNI 4.0
|
|
cbr1 (21) - CBR.1
|
|
vbr1rt (22) - Real time VBR.1
|
|
vbr2rt (23) - Real time VBR.2
|
|
vbr3rt (24) - Real time VBR.3
|
|
vbr1nrt(25) - Non Real time VBR.1
|
|
vbr2nrt(26) - Non Real time VBR.2
|
|
vbr3nrt(27) - Non Real time VBR.3
|
|
ubr1 (28) - UBR.1
|
|
ubr2 (29) - UBR.2
|
|
stdabr (30) - TM 4.0 compliant standard ABR
|
|
cbr2 (31) - CBR.2
|
|
cbr3 (32) - CBR.3
|
|
|
|
For FRSM12 Card:
|
|
Not Supported. Derived from chanServType.
|
|
"
|
|
DEFVAL {atfr}
|
|
::= { frChanCnfGrpEntry 43 }
|
|
|
|
frRoutingPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (1..15)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This is used by PXM to determine how important this
|
|
connection is when selecting connections to route
|
|
"
|
|
DEFVAL {1}
|
|
::= { frChanCnfGrpEntry 44 }
|
|
|
|
frMaxCost OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object specifies the
|
|
Maximum allowed cost. It is related to Cost Based Routing.
|
|
This is used by PXM so that it won't choose a path with
|
|
a cost greater than this configured level. This is not
|
|
necessary to be provided in the connection setup request,
|
|
if not provided, the default value 255 will be used.
|
|
|
|
Also the range supported depends upon the controller
|
|
configured :
|
|
|
|
Controller Range Default Value
|
|
|
|
chanFrConnType = par(2) 1..65535 255
|
|
chanFrConnType = pnni(5) 1..2147483647 2147483647.
|
|
"
|
|
::= { frChanCnfGrpEntry 45 }
|
|
|
|
frRestrictTrunkType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
norestriction (1),
|
|
terrestrialTrunk (2),
|
|
sateliteTrunk (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Restricted trunk type for routing, used by PXM. It
|
|
specifies that the connection either cannot be routed over
|
|
satelite trunks, or terrestrial trunks, or it can be on
|
|
any type of trunk. It is not necessary to be provide in
|
|
the connection setup request, the default value is
|
|
norestriction(1).
|
|
|
|
For FRSM12 Card: Not Supported
|
|
"
|
|
DEFVAL {norestriction}
|
|
::= { frChanCnfGrpEntry 46 }
|
|
|
|
frConnPCR OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies
|
|
the PCR(Peak Cell Rate). If not provided in
|
|
the connection setup request, it'll be derived from
|
|
object 'pir'.
|
|
|
|
For FRSM12 Card:
|
|
Default value is (1.44 * CIR)
|
|
"
|
|
::= { frChanCnfGrpEntry 47 }
|
|
|
|
frConnRemotePCR OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Peak cell rate of the other end, if not set, will be
|
|
set to the same as local end PCR (frConnPCR). However,
|
|
note that if the CIRs for both local and remote end
|
|
are set to the different value (i.e., asymmetric conn),
|
|
then this should be set differently from local end PCR.
|
|
For FRSM12 Card:
|
|
Default value is frConnPCR
|
|
"
|
|
::= { frChanCnfGrpEntry 48 }
|
|
|
|
frConnMCR OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Minimum cell rate, if not provided in the connection setup
|
|
request, it'll be derived from object 'mir'.
|
|
For FRSM12 Card:
|
|
Default value is frConnPCR
|
|
"
|
|
::= { frChanCnfGrpEntry 49 }
|
|
|
|
frConnRemoteMCR OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Minimum cell rate of the other end, if not set, will be
|
|
set to the same as local end MCR (frConnMCR). However,
|
|
note that if the CIRs for both local and remote end
|
|
are set to the different value (i.e., asymmetric conn),
|
|
then this should be set differently from local end MCR.
|
|
For FRSM12 Card:
|
|
Default value is frConnMCR
|
|
"
|
|
::= { frChanCnfGrpEntry 50 }
|
|
|
|
frConnPercentUtil OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the expected long-term utilization of the
|
|
channel by this end-point. If this is not specified in
|
|
the connection setup request, it'll be defaulted to
|
|
100 percent
|
|
|
|
For FRSM12 Card: Not Supported
|
|
"
|
|
DEFVAL {100}
|
|
::= {frChanCnfGrpEntry 51 }
|
|
|
|
frConnRemotePercentUtil OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the expected long-term utilization of the
|
|
channel by the other end-point. If this is not specified in
|
|
the connection setup request, it'll be set to be the same
|
|
as the local end frConnPercentUtil value assuming that the
|
|
connection is symmetric. In a asymmetric connection, this
|
|
object is supposed to be set.
|
|
|
|
For FRSM12 Card: Not Supported."
|
|
::= { frChanCnfGrpEntry 52 }
|
|
|
|
frConnForeSightEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used by the controller(PAR/PNNI/TAG) to
|
|
set up the Qbin for the connection, if this is not set,
|
|
it'll be defaulted by SM to the same as foreSightEnable
|
|
in the end point parameters.
|
|
|
|
For FRSM12 Card: Not Supported."
|
|
::= { frChanCnfGrpEntry 53 }
|
|
|
|
frConnFGCRAEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is used for
|
|
enabling/disabling Frame based GCRA
|
|
(early packet discard).
|
|
|
|
For FRSM12 Card: Not Supported."
|
|
|
|
DEFVAL {disable}
|
|
::= { frChanCnfGrpEntry 54}
|
|
|
|
chanServType OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
highpriority(1),
|
|
rtVBR(2),
|
|
nrtVBR(3),
|
|
aBR(4),
|
|
uBR(5),
|
|
queue6(6),
|
|
queue7(7),
|
|
queue8(8),
|
|
stdABR(9)
|
|
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object indicates the
|
|
indicates the class of the connection.
|
|
1-High priority (typically CBR connections)
|
|
2- real-time VBR
|
|
3- non-real time VBR
|
|
4- Available Bit Rate
|
|
5- Unspecified Bit Rate
|
|
9- Standard ABR
|
|
There are 8 queues actually but only 4 are being used
|
|
(the 4 queues are for CBR, VBR-rt, <VBR-nrt and ABR>, UBR traffic).
|
|
This object is suported only in FRSM-VHS and FRSM-8T1E1.
|
|
For FRSM-8T1E1, a 0 indicates that the connections are of old model
|
|
type where chanServType object is unused.
|
|
|
|
For FRSM12 Card:
|
|
The types aBR, queue6, queue7, queue8 are not supported
|
|
|
|
This object can not be modified after a frame relay
|
|
connection has been created."
|
|
::= { frChanCnfGrpEntry 55 }
|
|
|
|
chanServiceRateOverride OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable sets the SAR IR programming option.
|
|
Foresight and chanServiceRateOverride are mutually exclusive.
|
|
|
|
For FRSM12 Card: Not Supported."
|
|
DEFVAL {disable}
|
|
::= { frChanCnfGrpEntry 56 }
|
|
|
|
chanServiceRate OBJECT-TYPE
|
|
SYNTAX Integer32 (160..6400000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the rate to which IR can be set to when
|
|
chanServiceRateOverride is set to enable(1). If
|
|
chanServiceRateOverride is disable(2) then this object
|
|
does not have any significance.
|
|
For FRSM-8T1/8E1,this is defined in fastpackets/sec.
|
|
For FRSM-VHS, this is defined in atm cells per second.
|
|
For VHS the range in cells per second will be 10 to 400000 cps.
|
|
|
|
For FRSM12 Card: Not Supported."
|
|
|
|
::= { frChanCnfGrpEntry 57 }
|
|
|
|
zeroCirConEir OBJECT-TYPE
|
|
SYNTAX Integer32 (0..52000000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object defines defines EIR
|
|
value for '0' CIR connection.
|
|
|
|
If the value is '0', EIR is set to port speed.
|
|
If zeroCirConEir is non-zero value, EIR is set
|
|
to value of this object, and this value
|
|
is used for policing in ingress direction.
|
|
|
|
This object is valid only for a zero cir connection.
|
|
zeroCirConEir has to be less than or equal to the port speed."
|
|
|
|
DEFVAL {0}
|
|
::= { frChanCnfGrpEntry 58}
|
|
|
|
chanReroute OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This is used by the administrator to trigger the re-routing
|
|
of the connection. The rerouting takes effect, when this object
|
|
is set to true(1). When set to false (2), no action is taken.
|
|
A get on this object always returns false (2).
|
|
This object is not applicable to MGX Release 1.x.
|
|
"
|
|
DEFVAL {false}
|
|
::= { frChanCnfGrpEntry 59 }
|
|
|
|
frConnSCR OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Sustained cell rate, Used for VBR connections setup with PNNI
|
|
controller.
|
|
For FRSM12 Card: Default value is frConnPCR
|
|
This object is not applicable to MGX Release 1.x."
|
|
::= { frChanCnfGrpEntry 60 }
|
|
|
|
frConnRemoteSCR OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Sustained cell rate of the other end, Used for VBR connections
|
|
setup with PNNI controller.
|
|
For FRSM12 Card: Default value is frConnSCR
|
|
This object is not applicable to MGX Release 1.x
|
|
"
|
|
::= { frChanCnfGrpEntry 61 }
|
|
|
|
frConnTemplateId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..17)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the template identifier for the connection
|
|
template associated with this connection.
|
|
The valid range for templates is 1..16.
|
|
A value of 17 indicates no template is associated with this
|
|
connection
|
|
For FRSM12 Card: Not Supported
|
|
This object is not applicable to MGX Release 1.x
|
|
"
|
|
DEFVAL {17}
|
|
::= { frChanCnfGrpEntry 62 }
|
|
|
|
frConnAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies channel admin status.
|
|
This object is not applicable to MGX Release 1.x."
|
|
DEFVAL {down}
|
|
::= { frChanCnfGrpEntry 63 }
|
|
|
|
-- added for FRSM12
|
|
frChanCnfChangeCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is added only for FRSM12 card.
|
|
|
|
This counter tracks the number of configuration changes
|
|
that happen on a channel. The counter is
|
|
associated only with the end point and NOT with the
|
|
connection itself.
|
|
|
|
This counter is used by the NMS to determine if a connection
|
|
configuration had been modified and requires an upload.
|
|
This functionality is conventionally achieved by time
|
|
stamping using a time-of-day clock. However, in switches
|
|
where time-of-day clock is not available, the following
|
|
scheme is used:
|
|
|
|
The upload counter is incremented, when:
|
|
|
|
* assignment of connection to an end point channel. This
|
|
happens when a connection is added and assigned this
|
|
channel number.
|
|
* de-assignment of connection from a channel number. This
|
|
happens when a connection is deleted and the
|
|
end point resource is released.
|
|
* When there is a configuration change done to the connection
|
|
that is associated with this end point channel number.
|
|
|
|
In a new system, an unutilised resouce (channel number)
|
|
has a counter value of zero. When a connection is added to
|
|
this channel end point, the counter is incremented. And is
|
|
incremented for any of the above operations. When a connection
|
|
is deleted the value of this counter is incremented and
|
|
preserved till a new connection gets associated with this
|
|
channel end point.
|
|
|
|
This object is not applicable to MGX Release 1.x."
|
|
::= { frChanCnfGrpEntry 64 }
|
|
|
|
-- added for FRSM12
|
|
frChanCnfIgnoreIncomingDE OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is added for FRSM12 card.
|
|
When this object is enabled, the incoming frames with
|
|
DE(Discard Eligible) bit set to 1 are counted in the
|
|
Bc bucket instead of Be bucket
|
|
|
|
This object is not applicable to MGX Release 1.x."
|
|
::= { frChanCnfGrpEntry 65 }
|
|
|
|
-- FRSM12 Following Object is needed if channel Status Objects in MIB
|
|
-- "cardSpecificSM.my" on FRSM12 due to scalability issues, OAMCC per PVC
|
|
-- will be done as this is handled by HW (ATLAS). The OAM LoopBack as
|
|
-- on FRSM, will not be supported. FRSM12 will loop back incoming OAM loopback
|
|
-- cells originating from FRSM. But the test cannot be initiated
|
|
-- on FRSM12 (No HW support, will be too much CPU burning for 16K Conns.)
|
|
-- Instead of the FRSM TRAP "50311", "trapGenFrChanAlarm (50393)
|
|
-- will be used when OAM CC detects Chan Failure.
|
|
|
|
-- added for FRSM12
|
|
frChanOamCCEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is added for FRSM12 card.
|
|
|
|
This object serves to enable or disable continuity check(CC)
|
|
on a connection endpoint. When continuity check is enabled
|
|
on an endpoint, the endpoint anticipates OAM CC cells from its
|
|
peer endpoint. OAM CC cells are sent when the peer endpoint
|
|
does not have traffic cells to send. If the connection is
|
|
idle and this endpoint has not received OAM CC cells for a
|
|
period of 3.5 +/- 0.5 seconds, it declares continuity failure.
|
|
|
|
This object serves to administratively control the CC feature.
|
|
Typical implementations (of this feature) may choose to ignore
|
|
this control or impose other conditions to actually enable CC
|
|
cell flow. However, if this object is set to false(2), then this
|
|
feature should be disabled
|
|
|
|
This object is not applicable to MGX Release 1.x."
|
|
DEFVAL { disable }
|
|
::= { frChanCnfGrpEntry 66 }
|
|
|
|
frChanStatsEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This object serves the purpose of enabling/disabling statistics
|
|
collection on a per connection basis. In implementations which
|
|
do not have such limitations, this object can be set to enable(1)
|
|
for all connections.
|
|
|
|
Limits imposed by software or hardware implementations
|
|
could restrict the amount of statistical data that can be
|
|
maintained in a physical entity (like a service module card).
|
|
Hence there could be a need to restrict statistics collection
|
|
to a smaller subset.
|
|
|
|
This object is not applicable to MGX Release 1.x."
|
|
DEFVAL { disable }
|
|
::= { frChanCnfGrpEntry 67 }
|
|
|
|
-- added for FRSM12
|
|
frChanLocalLpbkEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is added for FRSM12 card.
|
|
This object when enabled adds a channel-level loopback
|
|
towards the port side. If the connection is in loopback,
|
|
Connection MIB (FrChanCnfGrpEntry) variables cannot be modified.
|
|
|
|
This object is not applicable to MGX Release 1.x.
|
|
"
|
|
DEFVAL { disable }
|
|
::= { frChanCnfGrpEntry 68 }
|
|
|
|
frChanUpcEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable (1),
|
|
disable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This object is added for FRSM12 card.
|
|
|
|
This object when disabled, disables Frame Relay policing.
|
|
|
|
This object is not applicable to MGX Release 1.x.
|
|
"
|
|
DEFVAL { enable }
|
|
::= { frChanCnfGrpEntry 69 }
|
|
|
|
frChanSlaveType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
persistentSlave (1),
|
|
nonPersistentSlave (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is added for FRSM12 card.
|
|
This object indicates whether a master endpoint has a persistent
|
|
slave or not. A connection with a master and a non-persistent
|
|
slave is considered a single-ended SPVC.
|
|
|
|
This object is only meaningful when 'frMastership'
|
|
contains the value of 'master(1)'. And this variable
|
|
must be used with 'frMastership' to decide
|
|
if a connection is single-ended or not.
|
|
|
|
This object is not applicable to MGX Release 1.x."
|
|
DEFVAL { persistentSlave }
|
|
::= { frChanCnfGrpEntry 70 }
|
|
|
|
frConnRemoteMBS OBJECT-TYPE
|
|
SYNTAX Integer32 (1..5000000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote Maximum Burst Size in terms of number of cells.
|
|
This object should be set by the user in cases when
|
|
the remote end of the connection is an ATM end-point
|
|
where the Local MBS can be explicitly specified. In such
|
|
cases, this element should be set to be equal to the
|
|
remote end-point's local MBS.
|
|
|
|
This object is not applicable to MGX Release 1.x.
|
|
"
|
|
DEFVAL {1024}
|
|
::= { frChanCnfGrpEntry 71 }
|
|
|
|
frChanPrefRouteId OBJECT-TYPE
|
|
SYNTAX Integer32(0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object serves to to associate a preferred
|
|
route with a connection.
|
|
|
|
The value '0' means no preferred route is associated with
|
|
this connection.
|
|
|
|
Usage:
|
|
- If the value of this set to 0, the object
|
|
frChanDirectRoute is automatically set to FALSE by
|
|
the switch.
|
|
- The preferred route is defined in cwaPrefRouteConfTable
|
|
object."
|
|
DEFVAL { 0 }
|
|
::= { frChanCnfGrpEntry 72 }
|
|
|
|
frChanDirectRoute OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object serves to associate a prefer
|
|
route as directed route (correspond to the prefer route
|
|
object frChanPrefRouteId).
|
|
|
|
A directed route specifies that the associated preferred
|
|
route is the only permission route for the connection to
|
|
take. Should the associated preferred route be unavailable,
|
|
the connection is failed.
|
|
|
|
The object is not applicable if there is no associated
|
|
preferred route with the connection."
|
|
DEFVAL { false }
|
|
::= { frChanCnfGrpEntry 73 }
|
|
|
|
--
|
|
-- Next available channel
|
|
--
|
|
|
|
chanNumNextAvailable OBJECT-TYPE
|
|
SYNTAX Integer32 (16..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable contains the next UNUSED channel number
|
|
of the maximum possible value(depends upon the
|
|
service module).
|
|
This number can be used in channel config table, the
|
|
ChanNumNextAvailable gets updated if the number gets
|
|
used to create a logical channel.
|
|
A '0' indicates that no more channels are available.
|
|
|
|
For FRSM12 Card: Not Supported."
|
|
::= { frChanCnfGrp 2 }
|
|
|
|
-- ------------------------------------------------------------------------
|
|
--
|
|
-- frstdABRConfig group
|
|
-- Channel configurable parameters (VC)
|
|
--
|
|
-- ------------------------------------------------------------------------
|
|
--
|
|
|
|
frstdABRCnfGrpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrstdABRCnfGrpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is used for configuring ABR parameters
|
|
on a frame relay connection.
|
|
"
|
|
::= { frChanCnfGrp 3 }
|
|
|
|
frstdABRCnfGrpEntry OBJECT-TYPE
|
|
SYNTAX FrstdABRCnfGrpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in ABR Configuration table."
|
|
INDEX { frstdABRcnfChanNum }
|
|
::= { frstdABRCnfGrpTable 1 }
|
|
|
|
FrstdABRCnfGrpEntry ::=
|
|
SEQUENCE {
|
|
frstdABRcnfChanNum Integer32,
|
|
frstdABRTBE Integer32,
|
|
frstdABRFRTT Integer32,
|
|
frstdABRRDF Integer32,
|
|
frstdABRRIF Integer32,
|
|
frstdABRNrm Integer32,
|
|
frstdABRTrm Integer32,
|
|
frstdABRCDF Integer32,
|
|
frstdABRADTF Integer32,
|
|
frstdABRICR Integer32,
|
|
frstdABRMCR Integer32,
|
|
frstdABRPCR Integer32
|
|
}
|
|
|
|
frstdABRcnfChanNum OBJECT-TYPE
|
|
SYNTAX Integer32(1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Refers to the virtual connection index.
|
|
|
|
The value supported depends upon the type
|
|
of service module.
|
|
|
|
Supported Range for different Card Types:
|
|
|
|
FRSM-4T1/E1 : supported range is 16..271 (256 entries)
|
|
FRSM-8T1/E1 : supported range is 16..1015 (1000 entries)
|
|
FRSM-T3/E3/HS2/
|
|
/HS2B-HSSI/T3B/E3B : supported range is 16..2015 (2000 entries)
|
|
FRSM-2CT3/HS2B-12IN1: supported range is 16..4015 (4000 entries)
|
|
|
|
FRSM12 Card:
|
|
Byte 3 = Chassis Number, Byte 2 = Slot Number,
|
|
Byte 1 & 0 = channel Number.
|
|
Lower two bytes range from 16..16015 (16000 entries)
|
|
"
|
|
::= { frstdABRCnfGrpEntry 1}
|
|
|
|
frstdABRTBE OBJECT-TYPE
|
|
SYNTAX Integer32 (0..16777215)
|
|
UNITS "cells"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is equal to
|
|
Transient Buffer Exposure(TBE). The TBE is a negotiated
|
|
number of cells that the network would like to limit
|
|
the source to sending during startup periods, before the
|
|
first RM-cell returns."
|
|
DEFVAL {16777215}
|
|
::= { frstdABRCnfGrpEntry 2}
|
|
|
|
frstdABRFRTT OBJECT-TYPE
|
|
SYNTAX Integer32 (0..16700)
|
|
UNITS "milli-seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is equal to
|
|
Fixed Round-Trip Time(FRTT). The FRTT is
|
|
sum of the fixed propogation delays from
|
|
the source to a destination network.
|
|
|
|
The Value 0 signifies that FRTT is not available."
|
|
DEFVAL {0}
|
|
::= { frstdABRCnfGrpEntry 3 }
|
|
|
|
frstdABRRDF OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32768)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is equal to
|
|
Rate Decrease Factor(RDF). The RDF controls the
|
|
rate decrease which occurs when backward RM-cells
|
|
with CI=1 are received. Larger values lead to faster
|
|
rate decrease.
|
|
|
|
The value specified has to be inverted to
|
|
arrive at the actual value.
|
|
The valid values possible are only powers of 2;
|
|
i.e. 1, 2, 4, 8 ..... 32768.
|
|
The SNMP agent has to verify this compliance."
|
|
DEFVAL {16}
|
|
::= { frstdABRCnfGrpEntry 4 }
|
|
|
|
frstdABRRIF OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32768)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is equal to
|
|
Rate Increase Factor(RIF). The RIF controls the
|
|
rate increase which occurs when a backward RM-cell
|
|
is received with CI=0 and NI=0.
|
|
|
|
The value specified has to be inverted to arrive
|
|
at the actual value.
|
|
The valid values possible are only powers
|
|
of 2; i.e. 1, 2, 4, 8 ..... 32768.
|
|
The SNMP agent has to verify this
|
|
compliance."
|
|
DEFVAL {64}
|
|
::= { frstdABRCnfGrpEntry 5 }
|
|
|
|
frstdABRNrm OBJECT-TYPE
|
|
SYNTAX Integer32 (2..256)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is equal to
|
|
number of cells a source may send for each
|
|
forward RM cell.
|
|
The valid values possible are only powers of 2
|
|
starting from 2; i.e. 2, 4, 8 ..... 256.
|
|
The SNMP agent has to verify this compliance."
|
|
DEFVAL {64}
|
|
::= { frstdABRCnfGrpEntry 6 }
|
|
|
|
frstdABRTrm OBJECT-TYPE
|
|
SYNTAX Integer32 (3..255)
|
|
UNITS "milli-seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is equal to
|
|
Upper bound on the time between forward RM
|
|
cells for an active source."
|
|
DEFVAL {255}
|
|
::= { frstdABRCnfGrpEntry 7 }
|
|
|
|
frstdABRCDF OBJECT-TYPE
|
|
SYNTAX Integer32 (0..64)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is equal to
|
|
Cutoff Decrease Factor(CDF). The value specified
|
|
has to be inverted to arrive at the actual value.
|
|
The valid values possible are 0
|
|
and only powers of 2; i.e., 1, 2, 4, 8, 16, 32, 64.
|
|
The SNMP agent has to verify this compliance."
|
|
DEFVAL {16}
|
|
::= { frstdABRCnfGrpEntry 8 }
|
|
|
|
frstdABRADTF OBJECT-TYPE
|
|
SYNTAX Integer32 (10..10230)
|
|
UNITS "milli-seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is equal to
|
|
ACR Decrease Time Factor(ADTF).
|
|
The Granularity allowed is 10 milli seconds.
|
|
i.e. 10,20,30 etc.
|
|
The SNMP agent has to verify this compliance."
|
|
DEFVAL {500}
|
|
::= { frstdABRCnfGrpEntry 9 }
|
|
|
|
frstdABRICR OBJECT-TYPE
|
|
SYNTAX Integer32 (10..400000)
|
|
UNITS "cells-per-second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is equal to
|
|
Initial Cell Rate(ICR). The ICR is the rate at which
|
|
the source should send initially and after an idle period.
|
|
This includes the bandwidth allocated for both data cells
|
|
as well as all in-rate RM cells."
|
|
DEFVAL {10}
|
|
::= { frstdABRCnfGrpEntry 10 }
|
|
|
|
frstdABRMCR OBJECT-TYPE
|
|
SYNTAX Integer32 (10..400000)
|
|
UNITS "cells-per-second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is equal to
|
|
Minimum Cell Rate(MCR). The MCR is the rate at which
|
|
the source is allowed to send. This includes the bandwidth
|
|
allocated for both data cells as well as all in-rate RM cells."
|
|
DEFVAL {10}
|
|
::= { frstdABRCnfGrpEntry 11 }
|
|
|
|
frstdABRPCR OBJECT-TYPE
|
|
SYNTAX Integer32 (10..400000)
|
|
UNITS "cells-per-second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is equal to
|
|
Peak Cell Rate(PCR). The PCR is the rate at which
|
|
the source is allowed to send. This includes the
|
|
bandwidth allocated for both data cells as well as
|
|
all in-rate RM cells."
|
|
DEFVAL {10}
|
|
::= { frstdABRCnfGrpEntry 12 }
|
|
|
|
|
|
|
|
frChanStateGrp OBJECT IDENTIFIER ::= { frChan 2 }
|
|
|
|
-- ------------------------------------------------------------------------
|
|
--
|
|
-- Group frChannelState
|
|
-- Contains status information for channels(Frame relay Connections)
|
|
--
|
|
-- ------------------------------------------------------------------------
|
|
|
|
|
|
frChanStateGrpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrChanStateGrpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of transmit/receive states of channels."
|
|
::= { frChanStateGrp 1 }
|
|
|
|
frChanStateGrpEntry OBJECT-TYPE
|
|
SYNTAX FrChanStateGrpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry for FrChannelStateGrpEntry."
|
|
INDEX { stateChanNum }
|
|
::= { frChanStateGrpTable 1 }
|
|
|
|
FrChanStateGrpEntry ::=
|
|
SEQUENCE {
|
|
stateChanNum Integer32,
|
|
chanState INTEGER,
|
|
xmtAbitState INTEGER,
|
|
rcvAbitState INTEGER,
|
|
xmtATMState INTEGER,
|
|
rcvATMState INTEGER,
|
|
chanStatusBitMap Integer32
|
|
}
|
|
|
|
stateChanNum OBJECT-TYPE
|
|
SYNTAX Integer32(1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object refers to
|
|
frame relay connection.
|
|
|
|
The value must be same as the value of
|
|
the object 'chanNum' in frChanCnfGrpTable."
|
|
::= { frChanStateGrpEntry 1}
|
|
|
|
chanState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notConfigured(1),
|
|
okay(2),
|
|
alarm(3),
|
|
failed(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the LMI state of the
|
|
VC (channel).
|
|
The possible values are :
|
|
notConfigured(1): Connection Not configured
|
|
okay(2) : Connection is in Ok state
|
|
alarm(3) : Connection is in alarm
|
|
failed(4) : Connection is in failed state.
|
|
This is applicable only for PNNI."
|
|
::= { frChanStateGrpEntry 2}
|
|
|
|
xmtAbitState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
sendingAequal1(2),
|
|
sendingAequal0(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies the
|
|
A bit transmit state.
|
|
|
|
The possible values are :
|
|
|
|
off(1) : LMI is off
|
|
sendingAequal1(2) : LMI is on and connection is O.K.
|
|
sendingAequal0(3) : LMI is on and connection is failed."
|
|
::= { frChanStateGrpEntry 3}
|
|
|
|
rcvAbitState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
rcvingAequal1(2),
|
|
rcvingAequal0(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies the
|
|
A bit receive state.
|
|
|
|
The possible values are :
|
|
|
|
off(1) : LMI is off
|
|
rcvingAequal1(2) : LMI is on and connection is O.K.
|
|
rcvingAequal0(3) : LMI is on and connection is failed."
|
|
::= { frChanStateGrpEntry 4}
|
|
|
|
xmtATMState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notSending(1),
|
|
sendingAIS(2),
|
|
sendingFERF(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the transmit state of the
|
|
VC (channel) on the ATM side.
|
|
|
|
The possible values are :
|
|
|
|
notSending(1) : Not sending any state
|
|
sendingAIS(2) : Sending AIS OAM state
|
|
sendingFERF(2) : Sending FERF OAM state."
|
|
::= { frChanStateGrpEntry 5}
|
|
|
|
rcvATMState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notRcving(1),
|
|
rcvingAIS(2),
|
|
rcvingFERF(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the receive state of the
|
|
VC (channel) on the ATM side.
|
|
|
|
The possible values are :
|
|
|
|
notRcving(1) : Not receiving any state
|
|
rcvingAIS(2) : Receiving AIS OAM
|
|
rcvingFERF(2) : Receiving FERF OAM."
|
|
::= { frChanStateGrpEntry 6}
|
|
|
|
chanStatusBitMap OBJECT-TYPE
|
|
SYNTAX Integer32 (0..'ff'h)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the consolidated bit map of the channel alarm
|
|
state.
|
|
|
|
Individual bit positions are as defined below.
|
|
|
|
Bit position Fail/Alarm Reason
|
|
------------ ---------- ------
|
|
0 Alarm Reserved
|
|
1 Alarm n/w side AIS/RDI Rx
|
|
2 Fail Conditioned(A bit from n/w)
|
|
3 Alarm Reserved
|
|
4 Fail CC failed/RAS failed
|
|
5 Fail Mismatch
|
|
6 Alarm ingress A bit (LMI)
|
|
7 Alarm Reserved
|
|
|
|
Fail bitmap mask : 0x34
|
|
Alarm bitmap mask: 0xCB
|
|
|
|
This object is not applicable to MGX Release 1.x.
|
|
"
|
|
|
|
::= { frChanStateGrpEntry 7}
|
|
|
|
|
|
frEndPtMapGrp OBJECT IDENTIFIER ::= { frameRelay 3 }
|
|
|
|
frEndPtMapGrpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrEndPtMapGrpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the Endpoint Mapping table for
|
|
Frame Relay connections."
|
|
::= { frEndPtMapGrp 1 }
|
|
|
|
frEndPtMapGrpEntry OBJECT-TYPE
|
|
SYNTAX FrEndPtMapGrpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the frame relay connection Endpoint
|
|
table."
|
|
INDEX { endPortNum, endDLCI }
|
|
::= { frEndPtMapGrpTable 1 }
|
|
|
|
FrEndPtMapGrpEntry ::=
|
|
SEQUENCE {
|
|
endPortNum Integer32,
|
|
endDLCI Integer32,
|
|
endChanNum Integer32,
|
|
endLineNum Integer32
|
|
}
|
|
|
|
endPortNum OBJECT-TYPE
|
|
SYNTAX Integer32(1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the frame relay logical port.
|
|
The value for this object must be same as 'portNum'
|
|
object in frPortCnfPortGrpTable.
|
|
|
|
If ifTable is is implemented in a service module,
|
|
this object must be same as the ifIndex of frame relay port."
|
|
::= { frEndPtMapGrpEntry 1}
|
|
|
|
endDLCI OBJECT-TYPE
|
|
SYNTAX Integer32 (0..8388607)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is equal to the
|
|
DLCI value for this PVC endpoint."
|
|
::= { frEndPtMapGrpEntry 2}
|
|
|
|
endChanNum OBJECT-TYPE
|
|
SYNTAX Integer32(1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies the
|
|
frame relay connection number.
|
|
|
|
The value of this object is same as the
|
|
value of 'chanNum' object in frChanCnfGrpTable.
|
|
|
|
This object contains value 0, if
|
|
port.dlci is a multicast group."
|
|
::= { frEndPtMapGrpEntry 3}
|
|
|
|
endLineNum OBJECT-TYPE
|
|
SYNTAX Integer32(1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is equal to the physical
|
|
line(for example T1/E1) or ifIndex on which connection
|
|
is provisioned.
|
|
|
|
If ifTable is not implemented in a service module,
|
|
then the range is from 1 to Maximum number of lines
|
|
supported.
|
|
|
|
If ifTable is is implemented in a service module,
|
|
this object must be same as the ifIndex of the
|
|
interface (ifType=ds1(18),ds3(30)).
|
|
|
|
The value supported for this object depends upon
|
|
the type of service module:
|
|
FRSM-4T1/E1 : Range is from 1..4
|
|
FRSM-8T1/E1 : Range is from 1..8
|
|
FRSM-T3/E3/HS2: Range is from 1..2
|
|
FRSM-2CT3 : Range is from 1..56
|
|
|
|
with ifTable Support: must refer to ifIndex
|
|
of the interface.
|
|
"
|
|
::= { frEndPtMapGrpEntry 4}
|
|
|
|
|
|
-- conformance information
|
|
|
|
ciscoWanFrConnMIBConformance OBJECT IDENTIFIER ::= { ciscoWanFrConnMIB 2 }
|
|
|
|
ciscoWanFrConnMIBGroups OBJECT IDENTIFIER ::= { ciscoWanFrConnMIBConformance 1 }
|
|
ciscoWanFrConnMIBCompliances OBJECT IDENTIFIER ::= { ciscoWanFrConnMIBConformance 2 }
|
|
|
|
|
|
-- compliance statements
|
|
|
|
ciscoWanFrConnCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for SNMP entities
|
|
which support Frame realy connection MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
ciscoWanFrConnGroup,
|
|
ciscoWanFrConnTestGroup,
|
|
ciscoWanFrConnStateGroup,
|
|
ciscoWanFrConnEndptGroup,
|
|
ciscoWanFrConnABRGroup
|
|
}
|
|
GROUP ciscoWanFrConnForesightGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for those systems where
|
|
foresight feature is supported."
|
|
GROUP ciscoWanFrConnQueueGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for those systems where
|
|
threshold configuration for queue is supported."
|
|
::= { ciscoWanFrConnMIBCompliances 1 }
|
|
|
|
ciscoWanFrConnGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
chanNum,
|
|
chanRowStatus,
|
|
chanPortNum,
|
|
dLCI,
|
|
egressQSelect,
|
|
deTaggingEnable,
|
|
cir,
|
|
bc,
|
|
be,
|
|
ibs,
|
|
chanLocRmtLpbkState,
|
|
chanType,
|
|
chanFECNconfig,
|
|
chanDEtoCLPmap,
|
|
chanCLPtoDEmap,
|
|
chanIngrPercentUtil,
|
|
chanEgrPercentUtil,
|
|
chanEgrSrvRate,
|
|
chanOvrSubOvrRide,
|
|
chanFrConnType,
|
|
frCDRNumber,
|
|
frLocalVpi,
|
|
frLocalVci,
|
|
frLocalNSAP,
|
|
frRemoteVpi,
|
|
frRemoteVci,
|
|
frRemoteNSAP,
|
|
frMastership,
|
|
frVpcFlag,
|
|
frConnServiceType,
|
|
frRoutingPriority,
|
|
frMaxCost,
|
|
frRestrictTrunkType,
|
|
frConnPCR,
|
|
frConnRemotePCR,
|
|
frConnMCR,
|
|
frConnRemoteMCR,
|
|
frConnPercentUtil,
|
|
frConnRemotePercentUtil,
|
|
frConnForeSightEnable,
|
|
frConnFGCRAEnable,
|
|
chanServType,
|
|
chanServiceRateOverride,
|
|
chanServiceRate,
|
|
zeroCirConEir,
|
|
chanReroute,
|
|
frConnSCR,
|
|
frConnRemoteSCR,
|
|
frConnTemplateId,
|
|
frConnAdminStatus,
|
|
frChanCnfChangeCount,
|
|
frChanCnfIgnoreIncomingDE,
|
|
frChanOamCCEnable,
|
|
frChanStatsEnable ,
|
|
frChanLocalLpbkEnable,
|
|
frChanUpcEnable,
|
|
frChanSlaveType,
|
|
frConnRemoteMBS,
|
|
chanNumNextAvailable,
|
|
frChanPrefRouteId,
|
|
frChanDirectRoute
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information
|
|
applicable to a Frame Relay Connection."
|
|
::= { ciscoWanFrConnMIBGroups 1 }
|
|
|
|
ciscoWanFrConnForesightGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
foreSightEnable,
|
|
qir,
|
|
mir,
|
|
pir
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects related to foresight
|
|
feature of a frame realay connection."
|
|
::= { ciscoWanFrConnMIBGroups 2 }
|
|
|
|
ciscoWanFrConnQueueGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ingressQDepth,
|
|
ingressQDEThresh,
|
|
ingressQECNThresh,
|
|
egressQDepth,
|
|
egressQDEThresh,
|
|
egressQECNThresh
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects related to queue depth
|
|
egress/ingress thresholds."
|
|
::= { ciscoWanFrConnMIBGroups 3 }
|
|
|
|
ciscoWanFrConnTestGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
chanTestType,
|
|
chanTestState,
|
|
chanRTDResult
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects related to testing
|
|
Frame relay connections."
|
|
::= { ciscoWanFrConnMIBGroups 4 }
|
|
|
|
ciscoWanFrConnStateGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
stateChanNum,
|
|
chanState,
|
|
xmtAbitState,
|
|
rcvAbitState,
|
|
xmtATMState,
|
|
rcvATMState,
|
|
chanStatusBitMap
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects related to state
|
|
of Frame Relay connections."
|
|
::= { ciscoWanFrConnMIBGroups 5 }
|
|
|
|
ciscoWanFrConnEndptGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
endPortNum,
|
|
endDLCI,
|
|
endChanNum,
|
|
endLineNum
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects related to Endpoint
|
|
mapping in Frame Relay Connections."
|
|
::= { ciscoWanFrConnMIBGroups 6 }
|
|
|
|
ciscoWanFrConnABRGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
|
|
frstdABRcnfChanNum,
|
|
frstdABRTBE,
|
|
frstdABRFRTT,
|
|
frstdABRRDF,
|
|
frstdABRRIF,
|
|
frstdABRNrm,
|
|
frstdABRTrm,
|
|
frstdABRCDF,
|
|
frstdABRADTF,
|
|
frstdABRICR,
|
|
frstdABRMCR,
|
|
frstdABRPCR
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects related to ABR
|
|
in a frame relay connection."
|
|
::= { ciscoWanFrConnMIBGroups 7 }
|
|
|
|