MRV-IR-CHAR-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Counter32, Integer32, IpAddress FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC mrvLx, TrapSeverity FROM MRV-IR-SYSTEM-MIB; irCharMib MODULE-IDENTITY LAST-UPDATED "200711180000Z" -- 18 Nov 2007 (LX v5.2.1) ORGANIZATION "MRV Communications - BPD Division" CONTACT-INFO "Postal: MRV Communications, Inc. 295 Foster Street Littleton, MA 01460" DESCRIPTION "This is the MRV LX Character MIB module." ::= { mrvLx 2 } -- -- Textual conventions. -- IrContactState ::= INTEGER { open(1), closed(2) } -- -- Textual conventions. -- IrControlState ::= INTEGER { deassert(1), assert(2) } -- -- Port AccessType values. -- PortAccessType ::= INTEGER { local(1), remote(2), dynamic(3), power(4), sensor(5), apd(6), dataBuffer(7), tcpPipe(8), control(9), master(10), -- read-only slave(11), -- read-only ppp(12), -- read-only notify(13), -- read-only none(14), -- edap(15), hdam(16), ldam(17), lpd(18), ups(19) } -- -- Port speed values. -- PortSpeed ::= INTEGER { sp134(1), sp200(2), sp300(3), sp600(4), sp1200(5), sp2400(6), sp4800(7), sp9600(8), sp19200(9), sp38400(10), sp57600(11), sp115200(12), sp230400(13), sp460800(14), sp921600(15) } -- -- Port AuthType values. -- PortAuthType ::= INTEGER { none(1), securid(2), radius(3), tacacs(4), ldap(5), local(6) } -- -- Signal Status Values. -- SignalStatus ::= INTEGER { up(1), down(2) } -- -- Generic Group -- irCharNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of entries in irCharPortTable." ::= { irCharMib 1 } -- -- Character Port Table. -- irCharPortTable OBJECT-TYPE SYNTAX SEQUENCE OF IrCharPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of character port entries." ::= { irCharMib 2 } irCharPortEntry OBJECT-TYPE SYNTAX IrCharPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A character port entry." INDEX { irCharPortIndex } ::= { irCharPortTable 1 } IrCharPortEntry ::= SEQUENCE { irCharPortIndex INTEGER, irCharPortAccessType PortAccessType, irCharPortFlowControl INTEGER, irCharPortStopBits INTEGER, irCharPortParity INTEGER, irCharPortBitsPerChar INTEGER, irCharPortAutoDial INTEGER, irCharPortAutoHangup INTEGER, irCharPortAutobaud INTEGER, irCharPortAutobaudRetry INTEGER, irCharPortInSignalCts SignalStatus, irCharPortInSignalDsr SignalStatus, irCharPortInSignalDcd SignalStatus, irCharPortOutSignalRts SignalStatus, irCharPortOutSignalDtr SignalStatus, irCharPortSpeed PortSpeed, irCharPortPrompt DisplayString, irCharPortBreak INTEGER, irCharPortSpecialBreakString DisplayString, irCharPortSpecialBreak INTEGER, irCharPortInboundAuth PortAuthType, irCharPortOutboundAuth PortAuthType, irCharPortAuthFallback INTEGER, irCharPortRadiusAcct INTEGER, irCharPortTacacsAcct INTEGER, irCharPortTransparent INTEGER, irCharPortDataBufferSize INTEGER, irCharPortDataBufferSyslog INTEGER, irCharPortDataBufferDisplay INTEGER, irCharPortDataBufferTimeStamp INTEGER, irCharPortTelnetPort INTEGER, irCharPortSshPort INTEGER } irCharPortIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "An index value that uniquely identifies a port." ::= { irCharPortEntry 1 } irCharPortAccessType OBJECT-TYPE SYNTAX PortAccessType MAX-ACCESS read-write STATUS current DESCRIPTION "The access type value for the port." ::= { irCharPortEntry 2 } irCharPortFlowControl OBJECT-TYPE SYNTAX INTEGER { none(1), xon(2), cts(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The flow control mechanism configured for the port." ::= { irCharPortEntry 3 } irCharPortStopBits OBJECT-TYPE SYNTAX INTEGER(1..2) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of stop bits configured for the port." ::= { irCharPortEntry 4 } irCharPortParity OBJECT-TYPE SYNTAX INTEGER { none(1), odd(2), even(3), mark(4), space(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "The parity configured for the port." ::= { irCharPortEntry 5 } irCharPortBitsPerChar OBJECT-TYPE SYNTAX INTEGER(7..8) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of bits per character." ::= { irCharPortEntry 6 } irCharPortAutoDial OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The auto dial setting for the port. This object has been deprecated and will be removed in the next release." ::= { irCharPortEntry 7 } irCharPortAutoHangup OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The auto hangup setting for the port." ::= { irCharPortEntry 8 } irCharPortAutobaud OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The autobaud status for the port." ::= { irCharPortEntry 9 } irCharPortAutobaudRetry OBJECT-TYPE SYNTAX INTEGER(0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The autobaud retry interval (in secods)." ::= { irCharPortEntry 10 } irCharPortInSignalCts OBJECT-TYPE SYNTAX SignalStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the input CTS signal." ::= { irCharPortEntry 11 } irCharPortInSignalDsr OBJECT-TYPE SYNTAX SignalStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the input DSR signal." ::= { irCharPortEntry 12 } irCharPortInSignalDcd OBJECT-TYPE SYNTAX SignalStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the input DCD signal." ::= { irCharPortEntry 13 } irCharPortOutSignalRts OBJECT-TYPE SYNTAX SignalStatus MAX-ACCESS read-write STATUS current DESCRIPTION "The current value of the output RTS signal." ::= { irCharPortEntry 14 } irCharPortOutSignalDtr OBJECT-TYPE SYNTAX SignalStatus MAX-ACCESS read-write STATUS current DESCRIPTION "The current value of the output DTR signal." ::= { irCharPortEntry 15 } irCharPortSpeed OBJECT-TYPE SYNTAX PortSpeed MAX-ACCESS read-write STATUS current DESCRIPTION "The port speed in bits per second." ::= { irCharPortEntry 16 } irCharPortPrompt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "An administratively assigned prompt for the port." ::= { irCharPortEntry 17 } irCharPortBreak OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The break status for the port." ::= { irCharPortEntry 18 } irCharPortSpecialBreakString OBJECT-TYPE SYNTAX DisplayString (SIZE (0..7)) MAX-ACCESS read-write STATUS current DESCRIPTION "An administratively assigned special break string for the port." ::= { irCharPortEntry 19 } irCharPortSpecialBreak OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The special break status for the port." ::= { irCharPortEntry 20 } irCharPortInboundAuth OBJECT-TYPE SYNTAX PortAuthType MAX-ACCESS read-write STATUS current DESCRIPTION "The inbound authentication status for the port." ::= { irCharPortEntry 21 } irCharPortOutboundAuth OBJECT-TYPE SYNTAX PortAuthType MAX-ACCESS read-write STATUS current DESCRIPTION "The outbound authentication status for the port." ::= { irCharPortEntry 22 } irCharPortAuthFallback OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The Authentication fallback attempts for the port." ::= { irCharPortEntry 23 } irCharPortRadiusAcct OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Radius accounting status for the port." ::= { irCharPortEntry 24 } irCharPortTacacsAcct OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Tacacs accounting status for the port." ::= { irCharPortEntry 25 } irCharPortTransparent OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The transparent status for the port." ::= { irCharPortEntry 26 } irCharPortDataBufferSize OBJECT-TYPE SYNTAX INTEGER (1024..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "An administratively assigned data buffer log size" ::= { irCharPortEntry 27 } irCharPortDataBufferSyslog OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The data buffer syslog status for the port." ::= { irCharPortEntry 28 } irCharPortDataBufferDisplay OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2), prompt(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The data buffer display status for the port." ::= { irCharPortEntry 29 } irCharPortDataBufferTimeStamp OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The data buffer time stamp status for the port." ::= { irCharPortEntry 30 } irCharPortTelnetPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The configured port used to telnet to the device attached to this port." ::= { irCharPortEntry 31 } irCharPortSshPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The configured port used to SSH to the device attached to this port." ::= { irCharPortEntry 32 } -- -- Character Port Stats Table. -- irCharPortStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF IrCharPortStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of character port stats entries." ::= { irCharMib 3 } irCharPortStatsEntry OBJECT-TYPE SYNTAX IrCharPortStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A character port stats entry." AUGMENTS { irCharPortEntry } ::= { irCharPortStatsTable 1 } IrCharPortStatsEntry ::= SEQUENCE { irCharPortTransmitBytes Counter32, irCharPortReceiveBytes Counter32, irCharPortFrameErrors Counter32, irCharPortOverrunErrors Counter32, irCharPortParityErrors Counter32 } irCharPortTransmitBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes transmitted on the port." ::= { irCharPortStatsEntry 1 } irCharPortReceiveBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes received on the port." ::= { irCharPortStatsEntry 2 } irCharPortFrameErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frame errors on the port." ::= { irCharPortStatsEntry 3 } irCharPortOverrunErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of overrun errors on the port." ::= { irCharPortStatsEntry 4 } irCharPortParityErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of parity errors on the port." ::= { irCharPortStatsEntry 5 } -- -- Temp. Sensor Table -- irTempSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF IrTempSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of temperature sensor entries." ::= { irCharMib 4 } irTempSensorEntry OBJECT-TYPE SYNTAX IrTempSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A temp sensor entry." INDEX { irTempPortIndex, irTempSensorIndex } ::= { irTempSensorTable 1 } IrTempSensorEntry ::= SEQUENCE { irTempPortIndex INTEGER, irTempSensorIndex INTEGER, irTempValue INTEGER, irTempValueUnits INTEGER, irTempThresholdHigh INTEGER, irTempThresholdLow INTEGER, irTempTrapSeverity TrapSeverity, irTempHysteresis INTEGER } irTempPortIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The port on which the temp sensor is configured." ::= { irTempSensorEntry 1 } irTempSensorIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value that identifies a specific configured temp sensor." ::= { irTempSensorEntry 2 } irTempValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The current temperature value." ::= { irTempSensorEntry 3 } irTempValueUnits OBJECT-TYPE SYNTAX INTEGER { celsius(1), fahrenheit(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the units for the temperature value." ::= { irTempSensorEntry 4 } irTempThresholdHigh OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The high temperature threhsold value." ::= { irTempSensorEntry 5 } irTempThresholdLow OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The low temperature threhsold value." ::= { irTempSensorEntry 6 } irTempTrapSeverity OBJECT-TYPE SYNTAX TrapSeverity MAX-ACCESS read-write STATUS current DESCRIPTION "The severity value to be sent in the threshold trap." ::= { irTempSensorEntry 7 } irTempHysteresis OBJECT-TYPE SYNTAX INTEGER (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "After crossing a threshold, the delta by which the caliberated value must drop within the normal range before the alarm condition is cleared (i.e. a cleared alarm is generated)." ::= { irTempSensorEntry 8 } -- -- Humidity Sensor Table. -- irHumiditySensorTable OBJECT-TYPE SYNTAX SEQUENCE OF IrHumiditySensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of humidity sensor entries." ::= { irCharMib 5 } irHumiditySensorEntry OBJECT-TYPE SYNTAX IrHumiditySensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A humidity sensor entry." INDEX { irHumidityPortIndex, irHumiditySensorIndex } ::= { irHumiditySensorTable 1 } IrHumiditySensorEntry ::= SEQUENCE { irHumidityPortIndex INTEGER, irHumiditySensorIndex INTEGER, irHumidityValue INTEGER, irHumidityThresholdHigh INTEGER, irHumidityThresholdLow INTEGER, irHumidityTrapSeverity TrapSeverity, irHumidityHysteresis INTEGER } irHumidityPortIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The port on which the humidity sensor is configured." ::= { irHumiditySensorEntry 1 } irHumiditySensorIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value that identifies a specific configured humidity sensor." ::= { irHumiditySensorEntry 2 } irHumidityValue OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The current humidity value (as a percentage)." ::= { irHumiditySensorEntry 3 } irHumidityThresholdHigh OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The high humidity threhsold value." ::= { irHumiditySensorEntry 4 } irHumidityThresholdLow OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The low humidity threhsold value." ::= { irHumiditySensorEntry 5 } irHumidityTrapSeverity OBJECT-TYPE SYNTAX TrapSeverity MAX-ACCESS read-write STATUS current DESCRIPTION "The severity value to be sent in the threshold trap." ::= { irHumiditySensorEntry 6 } irHumidityHysteresis OBJECT-TYPE SYNTAX INTEGER (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "After crossing a threshold, the delta by which the caliberated value must drop within the normal range before the alarm condition is cleared (i.e. a cleared alarm is generated)." ::= { irHumiditySensorEntry 7 } -- -- Power Port Table. -- irPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF IrPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of power port entries." ::= { irCharMib 6 } irPowerEntry OBJECT-TYPE SYNTAX IrPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A power port config entry." AUGMENTS { irCharPortEntry } ::= { irPowerTable 1 } IrPowerEntry ::= SEQUENCE { irPowerModuleType INTEGER, irPowerCurrentLoad DisplayString, irPowerOutletCount INTEGER, irPowerCurrentLoadA DisplayString, irPowerCurrentLoadB DisplayString, irPowerCurrentLoadC DisplayString } irPowerModuleType OBJECT-TYPE SYNTAX INTEGER { module5150(1), module4800(2), module5250(3), moduleOther(4), module5210(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of power module attached to the power port." ::= { irPowerEntry 1 } irPowerCurrentLoad OBJECT-TYPE SYNTAX DisplayString(SIZE(0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "An Ascii string indicating the total unit current load, in Amps." ::= { irPowerEntry 2 } -- ::= { irPowerEntry 3 } not used irPowerOutletCount OBJECT-TYPE SYNTAX INTEGER(0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of power outlets on the module." ::= { irPowerEntry 4 } irPowerCurrentLoadA OBJECT-TYPE SYNTAX DisplayString(SIZE(0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "An Ascii string indicating the current load, in Amps, of input feed A. Note that this info is available only on certain models. A value of 'N/A' indicates that this information is not available." ::= { irPowerEntry 5 } irPowerCurrentLoadB OBJECT-TYPE SYNTAX DisplayString(SIZE(0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "An Ascii string indicating the current load, in Amps, of input feed B. Note that this info is available only on certain models. A value of 'N/A' indicates that this information is not available." ::= { irPowerEntry 6 } irPowerCurrentLoadC OBJECT-TYPE SYNTAX DisplayString(SIZE(0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "An Ascii string indicating the current load, in Amps, of input feed C. Note that this info is available only on certain models. A value of 'N/A' indicates that this information is not available." ::= { irPowerEntry 7 } -- -- Power Outlet Table. -- irPowerOutletTable OBJECT-TYPE SYNTAX SEQUENCE OF IrPowerOutletEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of Power Outlet entries." ::= { irCharMib 7 } irPowerOutletEntry OBJECT-TYPE SYNTAX IrPowerOutletEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A power outlet entry." INDEX { irPowerPortIndex, irPowerOutletIndex } ::= { irPowerOutletTable 1 } IrPowerOutletEntry ::= SEQUENCE { irPowerPortIndex INTEGER, irPowerOutletIndex INTEGER, irPowerOutletName DisplayString, irPowerOutletStatus INTEGER, irPowerOutletAction INTEGER, irPowerOutletCurrentLoad DisplayString } irPowerPortIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "An index which uniquely identifies a physical power port." ::= { irPowerOutletEntry 1 } irPowerOutletIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "An index which uniquely identifies an outlet on a power outlet port." ::= { irPowerOutletEntry 2 } irPowerOutletName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "A name used to identify this power outlet." ::= { irPowerOutletEntry 3 } irPowerOutletStatus OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the power outlet." ::= { irPowerOutletEntry 4 } irPowerOutletAction OBJECT-TYPE SYNTAX INTEGER { other(1), on(2), off(3), reboot(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "A read of this object always returns the value other(1). Setting it to one of the other values causes the corresponding action to take place." ::= { irPowerOutletEntry 5 } irPowerOutletCurrentLoad OBJECT-TYPE SYNTAX DisplayString(SIZE(0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "An Ascii string indicating the current load, in Amps, for this outlet. A value of 'N/A' indicates that this information is not available." ::= { irPowerOutletEntry 6 } -- -- TcpPipe Port Table. -- irTcpPipeTable OBJECT-TYPE SYNTAX SEQUENCE OF IrTcpPipeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of TcpPipe port entries." ::= { irCharMib 8 } irTcpPipeEntry OBJECT-TYPE SYNTAX IrTcpPipeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A TcpPipe port config entry." AUGMENTS { irCharPortEntry } ::= { irTcpPipeTable 1 } IrTcpPipeEntry ::= SEQUENCE { irTcpPipeRemoteIpAddress IpAddress, irTcpPipeRemoteTcpPort INTEGER, irTcpPipeWindowSize INTEGER, irTcpPipeConnRetryCount INTEGER, irTcpPipeConnStatus INTEGER } irTcpPipeRemoteIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of the remote end of the TCP connection." ::= { irTcpPipeEntry 1 } irTcpPipeRemoteTcpPort OBJECT-TYPE SYNTAX INTEGER (2001..9999) MAX-ACCESS read-write STATUS current DESCRIPTION "The TCP port number for the remote end of the TCP connection." ::= { irTcpPipeEntry 2 } irTcpPipeWindowSize OBJECT-TYPE SYNTAX INTEGER (128..1400) MAX-ACCESS read-write STATUS current DESCRIPTION "The TCP window size to use for the TCP connection." ::= { irTcpPipeEntry 3 } irTcpPipeConnRetryCount OBJECT-TYPE SYNTAX INTEGER (0..60) MAX-ACCESS read-write STATUS current DESCRIPTION "The TCP connection retry count to use for the TCP connection." ::= { irTcpPipeEntry 4 } irTcpPipeConnStatus OBJECT-TYPE SYNTAX INTEGER { idle(0), connecting(1), connected(2), suspended(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The TCP connection status." ::= { irTcpPipeEntry 5 } -- -- Modem Group. -- irModem OBJECT IDENTIFIER ::= { irCharMib 9 } -- Modem Config Table. -- irModemCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF IrModemCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of modem config entries." ::= { irModem 1 } irModemCfgEntry OBJECT-TYPE SYNTAX IrModemCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A modem config entry." INDEX { irModemIndex } ::= { irModemCfgTable 1 } IrModemCfgEntry ::= SEQUENCE { irModemIndex INTEGER, irModemTimeout INTEGER, irModemRetry INTEGER, irModemState INTEGER, irModemPooling INTEGER, irModemDialNumber DisplayString, irModemInitString DisplayString } irModemIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "An index value that uniquely identifies a modem." ::= { irModemCfgEntry 1 } irModemTimeout OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The number of seconds to wait to detect remote end setting DSR signal high before giving up trying to establish a call." ::= { irModemCfgEntry 2 } irModemRetry OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "The number of times to try establishing a call." ::= { irModemCfgEntry 3 } irModemState OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This indicates whether the modem is enabled or disabled on a port." ::= { irModemCfgEntry 4 } irModemPooling OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This indicates whether modem pooling is enabled or disabled." ::= { irModemCfgEntry 5 } irModemDialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The phone number to dial when setting up a call." ::= { irModemCfgEntry 6 } irModemInitString OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The modem initialisation string." ::= { irModemCfgEntry 7 } irInternalModemPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The physical port to which an internal modem is attached. A value of 0 indicates there is no internal modem present." ::= { irModem 2 } irInternalModemType OBJECT-TYPE SYNTAX INTEGER { none(1), v90(2), rs485(3), gsmGprs(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of modem module installed in the system." ::= { irModem 3 } -- -- LD Alarm Config Table. -- irLdAlarmConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF IrLdAlarmConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ldam alarm port config entries." ::= { irCharMib 10 } irLdAlarmConfigEntry OBJECT-TYPE SYNTAX IrLdAlarmConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An ldam alarm port config entry." INDEX { irLdAlarmPortIndex, irLdAlarmPointIndex } ::= { irLdAlarmConfigTable 1 } IrLdAlarmConfigEntry ::= SEQUENCE { irLdAlarmPortIndex INTEGER, irLdAlarmPointIndex INTEGER, irLdAlarmName DisplayString, irLdAlarmDescription DisplayString, irLdAlarmContactState IrContactState, irLdAlarmContactFaultState IrContactState, irLdAlarmTrapStatus INTEGER, irLdAlarmTrapSeverity TrapSeverity, irLdAlarmCount Counter32, irLdAlarmTimestamp DisplayString } irLdAlarmPortIndex OBJECT-TYPE SYNTAX INTEGER (1..48) MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm port index." ::= { irLdAlarmConfigEntry 1 } irLdAlarmPointIndex OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "An integer which uniquely identifies an alarm point on this port." ::= { irLdAlarmConfigEntry 2 } irLdAlarmName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name assigned to the alarm point." ::= { irLdAlarmConfigEntry 3 } irLdAlarmDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "A user configurable alarm point description string." ::= { irLdAlarmConfigEntry 4 } irLdAlarmContactState OBJECT-TYPE SYNTAX IrContactState MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the alarm point contacts." ::= { irLdAlarmConfigEntry 5 } irLdAlarmContactFaultState OBJECT-TYPE SYNTAX IrContactState MAX-ACCESS read-write STATUS current DESCRIPTION "The contact state (open or closed) which indicates the fault condition. If the value of this object and irLdAlarmContactState is the same, then the alarm point has been triggered." ::= { irLdAlarmConfigEntry 6 } irLdAlarmTrapStatus OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This indicates whether an snmp trap will be generated when this alarm point is generated." ::= { irLdAlarmConfigEntry 7 } irLdAlarmTrapSeverity OBJECT-TYPE SYNTAX TrapSeverity MAX-ACCESS read-write STATUS current DESCRIPTION "The trap severity assigned to this alarm point. This value will be sent when an alarm fires and an snmp trap is generated." ::= { irLdAlarmConfigEntry 8 } irLdAlarmCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the alarm point has been generated since the LX was started." ::= { irLdAlarmConfigEntry 9 } irLdAlarmTimestamp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "A timestamp string indicating the time the last alarm was generated. A null string indicates that the alarm point has not been triggered." ::= { irLdAlarmConfigEntry 10 } -- -- LD Control Config Table. -- irLdControlConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF IrLdControlConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ldam control port config entries." ::= { irCharMib 11 } irLdControlConfigEntry OBJECT-TYPE SYNTAX IrLdControlConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An ldam control port config entry." INDEX { irLdControlPortIndex, irLdControlPointIndex } ::= { irLdControlConfigTable 1 } IrLdControlConfigEntry ::= SEQUENCE { irLdControlPortIndex INTEGER, irLdControlPointIndex INTEGER, irLdControlName DisplayString, irLdControlDescription DisplayString, irLdControlState IrControlState, irLdControlEnergizedState IrControlState } irLdControlPortIndex OBJECT-TYPE SYNTAX INTEGER (1..48) MAX-ACCESS read-only STATUS current DESCRIPTION "The control port index." ::= { irLdControlConfigEntry 1 } irLdControlPointIndex OBJECT-TYPE SYNTAX INTEGER (1) MAX-ACCESS read-only STATUS current DESCRIPTION "An integer which uniquely identifies a control point on this port." ::= { irLdControlConfigEntry 2 } irLdControlName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name assigned to the control point." ::= { irLdControlConfigEntry 3 } irLdControlDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "A user configurable control point description string." ::= { irLdControlConfigEntry 4 } irLdControlState OBJECT-TYPE SYNTAX IrControlState MAX-ACCESS read-write STATUS current DESCRIPTION "The configured control state (deassert or assert)." ::= { irLdControlConfigEntry 5 } irLdControlEnergizedState OBJECT-TYPE SYNTAX IrControlState MAX-ACCESS read-write STATUS current DESCRIPTION "The configured energized state (deassert or assert). If the value of this object and irLdControlState is the same, then the operational state will be on." ::= { irLdControlConfigEntry 6 } -- -- RS485 Port Table. -- irRs485PortTable OBJECT-TYPE SYNTAX SEQUENCE OF IrRs485PortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of RS485 character port entries." ::= { irCharMib 12 } irRs485PortEntry OBJECT-TYPE SYNTAX IrRs485PortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An RS485 character port entry." INDEX { irRs485PortIndex } ::= { irRs485PortTable 1 } IrRs485PortEntry ::= SEQUENCE { irRs485PortIndex INTEGER, irRs485PortDuplexMode INTEGER, irRs485PortEchoMode INTEGER, irRs485PortTransmitter INTEGER } irRs485PortIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "An index value that uniquely identifies an RS485 port. This value maps to the same index in the irCharPortTable." ::= { irRs485PortEntry 1 } irRs485PortDuplexMode OBJECT-TYPE SYNTAX INTEGER { full(1), half(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The duplex mode for this RS485 port." ::= { irRs485PortEntry 2 } irRs485PortEchoMode OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The echo mode for this RS4585 port. This is used when irRs485PortDuplexMode object is set to half(2)." ::= { irRs485PortEntry 3 } irRs485PortTransmitter OBJECT-TYPE SYNTAX INTEGER { always(1), rts(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The transmitter setting for this RS4585 port. This is used when irRs485PortDuplexMode object is set to full(1)." ::= { irRs485PortEntry 4 } -- -- GSM/GPRS Port Table. -- irGsmPortTable OBJECT-TYPE SYNTAX SEQUENCE OF IrGsmPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of GSM/GPRS port entries." ::= { irCharMib 13 } irGsmPortEntry OBJECT-TYPE SYNTAX IrGsmPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An GSM/GPRS port entry." INDEX { irGsmPortIndex } ::= { irGsmPortTable 1 } IrGsmPortEntry ::= SEQUENCE { irGsmPortIndex INTEGER, irGsmPortRcvSigStrength INTEGER, irGsmPortBitErrorRate INTEGER } irGsmPortIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "An index value that uniquely identifies an GSM/GPRS port. This value maps to the same index in the irCharPortTable." ::= { irGsmPortEntry 1 } irGsmPortRcvSigStrength OBJECT-TYPE SYNTAX INTEGER (0..31) MAX-ACCESS read-only STATUS current DESCRIPTION "The received signal strenth." ::= { irGsmPortEntry 2 } irGsmPortBitErrorRate OBJECT-TYPE SYNTAX INTEGER (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "The port bit error rate." ::= { irGsmPortEntry 3 } -- -- UPS Table. -- irUpsTable OBJECT-TYPE SYNTAX SEQUENCE OF IrUpsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of ups entries." ::= { irCharMib 14 } irUpsEntry OBJECT-TYPE SYNTAX IrUpsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A ups entry." AUGMENTS { irCharPortEntry } ::= { irUpsTable 1 } IrUpsEntry ::= SEQUENCE { irUpsType INTEGER, irUpsStatus INTEGER, irUpsModel DisplayString, irUpsCharge DisplayString, irUpsLoad DisplayString, irUpsLife DisplayString } irUpsType OBJECT-TYPE SYNTAX INTEGER { smart(1), simple(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The ups type. It indicates the protocol used to communicate with the ups. A value of smart(1) means use Ascii based commands. A value of simple(2) means use RS232 signals (DTR, CTS). Note that, when irUpsType is simple, only irUpsStatus info is available." ::= { irUpsEntry 1 } irUpsStatus OBJECT-TYPE SYNTAX INTEGER { offline(1), online(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The ups status. A value of offline(1) indicates the ups is not providing power to the attached devices. A value of online(2) indicates the ups is providing power to the attached devices." ::= { irUpsEntry 2 } irUpsModel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The ups model." ::= { irUpsEntry 3 } irUpsCharge OBJECT-TYPE SYNTAX DisplayString (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "The ups charge, as a percentage." ::= { irUpsEntry 4 } irUpsLoad OBJECT-TYPE SYNTAX DisplayString (SIZE (0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "The current load, as a percentage." ::= { irUpsEntry 5 } irUpsLife OBJECT-TYPE SYNTAX DisplayString (SIZE (0..4)) MAX-ACCESS read-only STATUS current DESCRIPTION "The ups life (time remaining), in minutes." ::= { irUpsEntry 6 } END