RC-CFM-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter64, Counter32, Gauge32 FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString, MacAddress, TruthValue, RowStatus, DateAndTime FROM SNMPv2-TC InterfaceIndex, InterfaceIndexOrZero FROM IF-MIB VlanIdOrNone FROM Q-BRIDGE-MIB rcCfm, EnableValue, CfmNameString FROM RAPID-CITY; rcCfmMib MODULE-IDENTITY LAST-UPDATED "200904100000Z" ORGANIZATION "Nortel Networks" CONTACT-INFO " Mike Nguyen Postal: Nortel Networks, Inc. 600 Technology Park Billerica, MA 01821 E-mail: minguyen@nortel.com" DESCRIPTION "OE MIB for Connectivity Fault Management" REVISION "200904100000Z" -- 10 Apr 2009 DESCRIPTION "Version 19: Added rcCfmMaintenanceEndPointLabel, rcCfmStatsAccessDrops, rcCfmStatsAggregateUplinkDrops. Modified rcCfmMaintenanceEndPointIfIndex, rcCfmMaintenanceEndPointCcmVlanId, rcCfmStatsIfTlvTx, rcCfmRemoteMepStatsIfTlvRx." REVISION "200903250000Z" -- 25 Mar 2009 DESCRIPTION "Version 18: Added enum value nodal(7) under rcCfmMaintenanceDomainType." REVISION "200903160000Z" -- 16 Mar 2009 DESCRIPTION "Version 17: Added rcCfmTransmitLbmFrameSize under RcCfmTransmitLbmEntry. Modified: syntax for rcCfmTransmitLbmStatus, rcCfmTransmitLbmResult." REVISION "200902270000Z" -- 27 Feb 2009 DESCRIPTION "Version 16: rcCfmTransmitLbmInterFrameInt default changed to 500" REVISION "200902100000Z" -- 10 Feb 2009 DESCRIPTION "Version 15: Added lowerLayerDown to rcCfmRemoteMepStatsIfTlvRx." REVISION "200902090000Z" -- 09 Feb 2009 DESCRIPTION "Version 14: SMIv2 cleanup. Added rcCfmMaintenanceEndPointIfIndex, rcCfmMaintenanceEndPointCcmVlanId" REVISION "200811100000Z" -- 10 Nov 2008 DESCRIPTION "Version 13: Added rcCfmGlobalsCcmTrapDisplayEnable." REVISION "200810030000Z" -- 03 Oct 2008 DESCRIPTION "Version 12: Added rcCfmDhuId as Attribute 32 under rcCfmTrap Group " REVISION "200809260000Z" -- 26 Sept 2008 DESCRIPTION "Version 11: Modified rcCfmMaintenanceEndPointMepDirection, rcCfmTrunkOperStatus, rcCfmTransmitLtmTtl, rcCfmLtrTtl. " REVISION "200807140000Z" -- 14 July 2008 DESCRIPTION "Version 10: Modified rcCfmTransmitLbmVlanDropEnable, CfmRelayActionFieldValue, rcCfmMaintenanceEndPointAisTxEnable, rcCfmMaintenanceEndPointAisInterval, rcCfmTransmitLtmStatus, rcCfmTransmitLbmMessages, RcCfmLtrEntry, rcCfmTransmitLtmFlag Added rcCfmMaintenanceDomainClearAisStats, rcCfmMaintenanceAssociationClearAisStats, rcCfmMaintenanceEndPointClearAisStats" REVISION "200805090000Z" -- 09 May 2008 DESCRIPTION "Version 9: Fixed smilint errors." REVISION "200803140000Z" -- 14 March 2008 DESCRIPTION "Version 8: Modified rcCfmGlobalsPortVid, RcCfmMaintenanceIntermediatePointEntry, rcCfmGlobalsEtherType, rcCfmGlobalsPortVid, rcCfmGlobalsPbtDropTrapTimer, rcCfmTransmitLtmResult, Added rcCfmMaintenanceEndPointAisTxEnable, rcCfmMaintenanceEndPointAisInterval, rcCfmMaintenanceEndPointIfTlv, rcCfmStatsIfTlvTx, rcCfmRemoteMepStatsIfTlvRx, rcCfmMaintenanceEndPointMepDirection, rcCfmTransmitLtmFlag, rcCfmLtrTable" REVISION "200712040000Z" -- 04 Dec 2007 DESCRIPTION "Version 7: Added rcCfmMaintenanceEndPointMepStatus, rcCfmTrunkRemote, missing EnableValue to rcCfmMaintenanceDomainPmEnable, missing quote at CONTACT-INFO, rcCfmTrunkDualHomePartner, Modified rcCfmTransmitLbmSeqNumber, rcCfmTransmitLtmSeqNumber, Removed rcCfmMaintenanceEndPointUserLabel1, rcCfmMaintenanceEndPointUserLabel2, rcCfmTrunkRemote" REVISION "200708160000Z" -- 16 Aug 2007 DESCRIPTION "Version 6: Modified rcCfmFdPerformanceTarget, rcCfmFdFdvPerformanceTarget, rcCfmFdStatsCurrTarget, rcCfmFdStatsCurrAverage, rcCfmFdStatsCurrMinimum, rcCfmFdStatsCurrMaximum, rcCfmFdStatsCurrFdvTarget, rcCfmFdStatsCurrFdvAverage, rcCfmFdStatsCurrFdvMinimum, rcCfmFdStatsCurrFdvMaximum, rcCfmFdStatsHistTarget, rcCfmFdStatsHistAverage, rcCfmFdStatsHistMinimum, rcCfmFdStatsHistMaximum, rcCfmFdStatsHistFdvTarget, rcCfmFdStatsHistFdvAverage, rcCfmFdStatsHistFdvMinimum, rcCfmFdStatsHistFdvMaximum" REVISION "200705150000Z" -- 15 May 2007 DESCRIPTION "Version 5: Correct the INDEX rcCfmPbtTrunkStatsName to not-accessible" REVISION "200705140000Z" -- 14 May 2007 DESCRIPTION "Version 4: Correct the INDEX rcCfmPortStatsIndex to not-accessible Added rcCfmFdvTarget and rcCfmFdvAverage" REVISION "200704180000Z" -- 22 Apr 2007 DESCRIPTION "Version 3: Added rcCfmMaintenanceDomainType,rcCfmMaintenanceDomainEventTrapEnable, rcCfmMaintenanceDomainPmEnable,rcCfmMaintenanceAssociationNumOfRemoteMep, rcCfmMaintenanceAssociationRemoveAutoRmep, rcCfmMaintenanceAssociationCcmRdiEnable, rcCfmMaintenanceAssociationCcmMulticast, rcCfmMaintenanceAssociationEventTrapEnable, rcCfmMaintenanceAssociationPmEnable, rcCfmMaintenanceEndPointServiceDescription, rcCfmMaintenanceEndPointRemoveAutoRmep, rcCfmMaintenanceEndPointUserLabel1, rcCfmMaintenanceEndPointUserLabel2, rcCfmTrunkGroupLoopBackVlanId,rcCfmTrunkGroupUserLabel1,rcCfmTrunkGroupUserLabel2, rcCfmPbtMsti,rcCfmTrunkClearStats,rcCfmTrunkUserLabel1,rcCfmTrunkUserLabel2, rcCfmTrunkSubportQueueSet,rcCfmStatsDefect, Added Atrributes 12-28 for rcCfmTrap Group, Added cCfmGlobalsPortVid,rcCfmGlobalsPbtDropTrapTimer and rcCfmGlobalsPmEnable Removed rcCfmMaintenanceEndPointServiceId,rcCfmMaintenanceEndPointServiceName (Not used)" REVISION "200606210000Z" -- 21 June 2006 DESCRIPTION "Version 2: Added rcCfmTrunkGroupIndication, rcCfmTrunkGroupProtected, rcCfmRemoteMepId, rcCfmLocalMepId,rcCfmMepCcmIndication, rcCfmCvid, rcCfmRemoteMacAddr,rcCfmIsidId to rcCfmTrap. Added rcCfmMaintenanceDomainLevel, rcCfmMaintenanceDomainNumOfMip, to rcCfmMaintenanceDomainTable Corrected/Updated the rcCfmMaintenanceAssociationTable. Corrected/updated rcCfmMaintenanceEndPointTable. Added rcCfmTrunkSourceMac to rcCfmTrunkTable Added rcCfmRemoteMaintenanceEndPointTable Added rcCfmMepLearnStatsTable Added rcCfmGlobalsPbtMac to rcCfmGlobals Added rcCfmMaintenanceIntermediatePointTable" REVISION "200602030000Z" -- 03 February 2006 DESCRIPTION "Version 1: Initial version" ::= { rcCfm 0 } -- Maintenance Domain Table rcCfmMaintenanceDomainTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmMaintenanceDomainEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management Maintenance Domain table" ::= { rcCfm 1} rcCfmMaintenanceDomainEntry OBJECT-TYPE SYNTAX RcCfmMaintenanceDomainEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management Maintenance Domain entry." INDEX {rcCfmMaintenanceDomainIndex } ::= { rcCfmMaintenanceDomainTable 1} RcCfmMaintenanceDomainEntry ::= SEQUENCE { rcCfmMaintenanceDomainIndex Integer32, rcCfmMaintenanceDomainName DisplayString, rcCfmMaintenanceDomainRowStatus RowStatus, rcCfmMaintenanceDomainNumOfMa Integer32, rcCfmMaintenanceDomainClearStats TruthValue, rcCfmMaintenanceDomainLevel Integer32, rcCfmMaintenanceDomainNumOfMip Integer32, rcCfmMaintenanceDomainType INTEGER, rcCfmMaintenanceDomainEventTrapEnable EnableValue, rcCfmMaintenanceDomainPmEnable EnableValue, rcCfmMaintenanceDomainClearAisStats TruthValue } rcCfmMaintenanceDomainIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Domain index" ::= { rcCfmMaintenanceDomainEntry 1} rcCfmMaintenanceDomainName OBJECT-TYPE SYNTAX DisplayString(SIZE (1..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmMaintenanceDomainEntry 2} rcCfmMaintenanceDomainRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Used to create/delete entries" ::= { rcCfmMaintenanceDomainEntry 3} rcCfmMaintenanceDomainNumOfMa OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of MAs belong to this maintenance domain" ::= { rcCfmMaintenanceDomainEntry 4 } rcCfmMaintenanceDomainClearStats OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "To clear the MEPS CCM sending/receiving message counter un der this domain" DEFVAL { false } ::= { rcCfmMaintenanceDomainEntry 5 } rcCfmMaintenanceDomainLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "To set the maintenance level in this domain" DEFVAL {4} ::= { rcCfmMaintenanceDomainEntry 6 } rcCfmMaintenanceDomainNumOfMip OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of Mips belong to this maintenance domain" ::= { rcCfmMaintenanceDomainEntry 7 } rcCfmMaintenanceDomainType OBJECT-TYPE SYNTAX INTEGER { none(0), trunk(1), sg(2), endpt(3), vlan(4), port(5), mimencapvlan(6), nodal(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "To indicate the type of domain" ::= { rcCfmMaintenanceDomainEntry 8 } rcCfmMaintenanceDomainEventTrapEnable OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Event Trap enable" REFERENCE "MERS v4.2 PRD - R15" DEFVAL {enable} ::= { rcCfmMaintenanceDomainEntry 9 } rcCfmMaintenanceDomainPmEnable OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Performance monitor enable" REFERENCE "MERS v4.2 PRD" DEFVAL {disable} ::= { rcCfmMaintenanceDomainEntry 10 } rcCfmMaintenanceDomainClearAisStats OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "To clear the AIS CCM sending/receiving message counter un der this domain" DEFVAL { false } ::= { rcCfmMaintenanceDomainEntry 11 } -- Maintenance Association Table rcCfmMaintenanceAssociationTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmMaintenanceAssociationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management Maintenance Association table" ::= { rcCfm 2} rcCfmMaintenanceAssociationEntry OBJECT-TYPE SYNTAX RcCfmMaintenanceAssociationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management Maintenance Association entry." INDEX {rcCfmMaintenanceAssociationDomainIndex, rcCfmMaintenanceAssociationAssociationIndex } ::= { rcCfmMaintenanceAssociationTable 1} RcCfmMaintenanceAssociationEntry ::= SEQUENCE { rcCfmMaintenanceAssociationDomainIndex Integer32, rcCfmMaintenanceAssociationAssociationIndex Integer32, rcCfmMaintenanceAssociationDomainName DisplayString, rcCfmMaintenanceAssociationAssociationName DisplayString, rcCfmMaintenanceAssociationAdminState EnableValue, rcCfmMaintenanceAssociationRowStatus RowStatus, rcCfmMaintenanceAssociationCcmInterval Integer32, rcCfmMaintenanceAssociationCcmLifetime Integer32, rcCfmMaintenanceAssociationCcmPriority Integer32, rcCfmMaintenanceAssociationCcmTxEnable EnableValue, rcCfmMaintenanceAssociationCcmRxEnable EnableValue, rcCfmMaintenanceAssociationNumOfMep Integer32, rcCfmMaintenanceAssociationClearStats TruthValue, rcCfmMaintenanceAssociationAutoDetect EnableValue, rcCfmMaintenanceAssociationNumOfRemoteMep Integer32, rcCfmMaintenanceAssociationRemoveAutoRmep Integer32, rcCfmMaintenanceAssociationCcmRdiEnable EnableValue, rcCfmMaintenanceAssociationCcmMulticast EnableValue, rcCfmMaintenanceAssociationEventTrapEnable EnableValue, rcCfmMaintenanceAssociationPmEnable EnableValue, rcCfmMaintenanceAssociationClearAisStats TruthValue } rcCfmMaintenanceAssociationDomainIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Association Domain Index" ::= { rcCfmMaintenanceAssociationEntry 1} rcCfmMaintenanceAssociationAssociationIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Association Index" ::= { rcCfmMaintenanceAssociationEntry 2} rcCfmMaintenanceAssociationDomainName OBJECT-TYPE SYNTAX DisplayString(SIZE (1..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Association Domain Name" ::= { rcCfmMaintenanceAssociationEntry 3} rcCfmMaintenanceAssociationAssociationName OBJECT-TYPE SYNTAX DisplayString(SIZE (1..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmMaintenanceAssociationEntry 4} rcCfmMaintenanceAssociationAdminState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Administratively enable or disable a maintenance association." DEFVAL { disable } ::= { rcCfmMaintenanceAssociationEntry 5} rcCfmMaintenanceAssociationRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Used to create/delete entries" ::= { rcCfmMaintenanceAssociationEntry 6} rcCfmMaintenanceAssociationCcmInterval OBJECT-TYPE SYNTAX Integer32 (0..65535000) UNITS "milliseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "Interval of periodic Continuity Check Message to be transmitted" DEFVAL { 5000 } ::= { rcCfmMaintenanceAssociationEntry 7} rcCfmMaintenanceAssociationCcmLifetime OBJECT-TYPE SYNTAX Integer32 (0..655350) MAX-ACCESS read-create STATUS current DESCRIPTION "Lifetime of periodic Continuity Check Message" DEFVAL { 15000 } ::= { rcCfmMaintenanceAssociationEntry 8} rcCfmMaintenanceAssociationCcmPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-create STATUS current DESCRIPTION "Priority of Continuity Check Message to be transmitted" DEFVAL { 7 } ::= { rcCfmMaintenanceAssociationEntry 9} rcCfmMaintenanceAssociationCcmTxEnable OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Continuity Check Message transmit enable" DEFVAL { disable } ::= { rcCfmMaintenanceAssociationEntry 10} rcCfmMaintenanceAssociationCcmRxEnable OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Continuity Check Message receive enable" DEFVAL { disable } ::= { rcCfmMaintenanceAssociationEntry 11} rcCfmMaintenanceAssociationNumOfMep OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of MEPs belong to this maintenance association" ::= { rcCfmMaintenanceAssociationEntry 12 } rcCfmMaintenanceAssociationClearStats OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "To clear the MEPs CCM sending/receiving message counter under this MA" DEFVAL { false } ::= { rcCfmMaintenanceAssociationEntry 13 } rcCfmMaintenanceAssociationAutoDetect OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates whether MA allows auto-detect of remote MEPs" DEFVAL { disable } ::= { rcCfmMaintenanceAssociationEntry 14 } rcCfmMaintenanceAssociationNumOfRemoteMep OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of remote MEPs belong to this maintenance association" ::= { rcCfmMaintenanceAssociationEntry 15 } rcCfmMaintenanceAssociationRemoveAutoRmep OBJECT-TYPE SYNTAX Integer32 (0..8191) MAX-ACCESS read-create STATUS current DESCRIPTION "Remove auto learned Remote Maintenance Endpoint ID, or 0 for unspecified" ::= { rcCfmMaintenanceAssociationEntry 16 } rcCfmMaintenanceAssociationCcmRdiEnable OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Continuity Check Message RDI enable" REFERENCE "MERS v4.2 PRD - R21,R24,R29,R33,R61,R73" DEFVAL {enable} ::= { rcCfmMaintenanceAssociationEntry 17 } rcCfmMaintenanceAssociationCcmMulticast OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates whether MA sends Multicast or Unicast CCMs" DEFVAL { enable } ::= { rcCfmMaintenanceAssociationEntry 18 } rcCfmMaintenanceAssociationEventTrapEnable OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Event Trap enable This MA level setting overrides MD level setting." REFERENCE "MERS v4.2 PRD - R15" DEFVAL {enable} ::= { rcCfmMaintenanceAssociationEntry 19 } rcCfmMaintenanceAssociationPmEnable OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Performance monitor enable This MA level setting overrides MD level setting." REFERENCE "MERS v4.2 PRD" DEFVAL {disable} ::= { rcCfmMaintenanceAssociationEntry 20 } rcCfmMaintenanceAssociationClearAisStats OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "To clear the Ais CCM sending/receiving message counter under this MA" DEFVAL { false } ::= { rcCfmMaintenanceAssociationEntry 21 } -- Maintenance EndPoint Table rcCfmMaintenanceEndPointTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmMaintenanceEndPointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management Maintenance Association table" ::= { rcCfm 3} rcCfmMaintenanceEndPointEntry OBJECT-TYPE SYNTAX RcCfmMaintenanceEndPointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management Maintenance EndPoint entry." INDEX {rcCfmMaintenanceEndPointDomainIndex, rcCfmMaintenanceEndPointAssociationIndex, rcCfmMaintenanceEndPointId } ::= { rcCfmMaintenanceEndPointTable 1} RcCfmMaintenanceEndPointEntry ::= SEQUENCE { rcCfmMaintenanceEndPointDomainIndex Integer32, rcCfmMaintenanceEndPointAssociationIndex Integer32, rcCfmMaintenanceEndPointId Integer32, rcCfmMaintenanceEndPointDomainName DisplayString, rcCfmMaintenanceEndPointAssociationName DisplayString, rcCfmMaintenanceEndPointAdminState EnableValue, rcCfmMaintenanceEndPointRowStatus RowStatus, rcCfmMaintenanceEndPointCcmPriority Integer32, rcCfmMaintenanceEndPointCcmTxEnable EnableValue, rcCfmMaintenanceEndPointCcmRxEnable EnableValue, rcCfmMaintenanceEndPointMepType INTEGER, rcCfmMaintenanceEndPointClearStats TruthValue, rcCfmMaintenanceEndPointServiceDescription DisplayString, rcCfmMaintenanceEndPointRemoveAutoRmep Integer32, rcCfmMaintenanceEndPointMepStatus INTEGER, rcCfmMaintenanceEndPointAisTxEnable EnableValue, rcCfmMaintenanceEndPointAisInterval INTEGER, rcCfmMaintenanceEndPointIfTlv EnableValue, rcCfmMaintenanceEndPointMepDirection INTEGER, rcCfmMaintenanceEndPointClearAisStats TruthValue, rcCfmMaintenanceEndPointIfIndex InterfaceIndexOrZero, rcCfmMaintenanceEndPointCcmVlanId VlanIdOrNone, rcCfmMaintenanceEndPointLabel DisplayString } rcCfmMaintenanceEndPointDomainIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmMaintenanceEndPointEntry 1} rcCfmMaintenanceEndPointAssociationIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmMaintenanceEndPointEntry 2} rcCfmMaintenanceEndPointId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance EndPoint ID" ::= { rcCfmMaintenanceEndPointEntry 3} rcCfmMaintenanceEndPointDomainName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmMaintenanceEndPointEntry 4} rcCfmMaintenanceEndPointAssociationName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmMaintenanceEndPointEntry 5} rcCfmMaintenanceEndPointAdminState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Administratively enable or disable a maintenance EndPoint." DEFVAL { disable } ::= { rcCfmMaintenanceEndPointEntry 6} rcCfmMaintenanceEndPointRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Used to create/delete entries" ::= { rcCfmMaintenanceEndPointEntry 7} rcCfmMaintenanceEndPointCcmPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-create STATUS current DESCRIPTION "Priority of Continuity Check Message to be transmitted" DEFVAL { 7 } ::= { rcCfmMaintenanceEndPointEntry 8} rcCfmMaintenanceEndPointCcmTxEnable OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Continuity Check Message transmit enable" DEFVAL { disable } ::= { rcCfmMaintenanceEndPointEntry 9} rcCfmMaintenanceEndPointCcmRxEnable OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Continuity Check Message receive enable" DEFVAL { disable } ::= { rcCfmMaintenanceEndPointEntry 10} rcCfmMaintenanceEndPointMepType OBJECT-TYPE SYNTAX INTEGER { trunk(1), sg(2), endpt(4), unused(8), vlan(16), port(32), endptClient(64), remotetrunk(32769), remotesg(32770), remoteendpt(32772), remoteVlan(32784), remotePort(32800), remoteEndptClient(32832), nodal(3145728) } MAX-ACCESS read-only STATUS current DESCRIPTION "Mep Type" ::= { rcCfmMaintenanceEndPointEntry 11 } rcCfmMaintenanceEndPointClearStats OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "To clear the MEP CCM sending/receiving message counter" DEFVAL { false } ::= { rcCfmMaintenanceEndPointEntry 12 } rcCfmMaintenanceEndPointServiceDescription OBJECT-TYPE SYNTAX DisplayString(SIZE (0..48)) MAX-ACCESS read-only STATUS current DESCRIPTION "Used to specify what service this mep assigned to" ::= { rcCfmMaintenanceEndPointEntry 13} rcCfmMaintenanceEndPointRemoveAutoRmep OBJECT-TYPE SYNTAX Integer32 (0..8191) MAX-ACCESS read-create STATUS current DESCRIPTION "Remove auto learned Remote Maintenance Endpoint ID, or 0 for unspecified" ::= { rcCfmMaintenanceEndPointEntry 14 } rcCfmMaintenanceEndPointMepStatus OBJECT-TYPE SYNTAX INTEGER { active(1), inactive(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicating if the mep status is active or inactive. Only Dual-Home Ring endpoint client meps can have active/inactive status. All other mep types have active status." ::= { rcCfmMaintenanceEndPointEntry 15 } rcCfmMaintenanceEndPointAisTxEnable OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Alarm Indication Signal Message transmit enable" DEFVAL { disable } ::= { rcCfmMaintenanceEndPointEntry 16} rcCfmMaintenanceEndPointAisInterval OBJECT-TYPE SYNTAX INTEGER{ intv1000(1000), intv60000(60000) } UNITS "milliseconds" MAX-ACCESS read-create STATUS current DESCRIPTION "Interval of periodic Alarm Indication Signal Message to be transmitted. Unit in milliseconds." DEFVAL { intv60000 } ::= { rcCfmMaintenanceEndPointEntry 17} rcCfmMaintenanceEndPointIfTlv OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Admin control of the Interface-Status-Tlv in maintenanceEndpoint." DEFVAL { disable } ::= { rcCfmMaintenanceEndPointEntry 18 } rcCfmMaintenanceEndPointMepDirection OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the direction in which the Maintenance association faces on the bridge port." DEFVAL { unknown } ::= { rcCfmMaintenanceEndPointEntry 19 } rcCfmMaintenanceEndPointClearAisStats OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "To clear the AIS sending/receiving message counter" DEFVAL { false } ::= { rcCfmMaintenanceEndPointEntry 20 } rcCfmMaintenanceEndPointIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-create STATUS current DESCRIPTION "This object is the interface index of the interface either a bridge port, or an aggregated IEEE 802.1 link within a bridge port, to which the MEP is attached." DEFVAL { 0 } ::= { rcCfmMaintenanceEndPointEntry 21 } rcCfmMaintenanceEndPointCcmVlanId OBJECT-TYPE SYNTAX VlanIdOrNone MAX-ACCESS read-create STATUS current DESCRIPTION "Customer CCM VLAN ID" DEFVAL { 0 } ::= { rcCfmMaintenanceEndPointEntry 22 } rcCfmMaintenanceEndPointLabel OBJECT-TYPE SYNTAX DisplayString (SIZE(0..48)) MAX-ACCESS read-create STATUS current DESCRIPTION "User provided field. Used to give extra management information/data." ::= { rcCfmMaintenanceEndPointEntry 23 } -- Trunk Group Table rcCfmTrunkGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmTrunkGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault TrunkGroup table" ::= { rcCfm 4} rcCfmTrunkGroupEntry OBJECT-TYPE SYNTAX RcCfmTrunkGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management TrunkGroup entry." INDEX {rcCfmTrunkGroupName} ::= { rcCfmTrunkGroupTable 1} RcCfmTrunkGroupEntry ::= SEQUENCE { rcCfmTrunkGroupName CfmNameString, rcCfmTrunkGroupRowStatus RowStatus, rcCfmTrunkGroupPrimaryTrunk DisplayString, rcCfmTrunkGroupSecondaryTrunk DisplayString, rcCfmTrunkGroupActiveTrunk DisplayString, rcCfmTrunkGroupRevertive EnableValue, rcCfmTrunkGroupLoopBackVlanId Integer32, rcCfmTrunkGroupUserLabel1 OCTET STRING, rcCfmTrunkGroupUserLabel2 OCTET STRING } rcCfmTrunkGroupName OBJECT-TYPE SYNTAX CfmNameString MAX-ACCESS not-accessible STATUS current DESCRIPTION "Trunk Group Name" ::= { rcCfmTrunkGroupEntry 1} rcCfmTrunkGroupRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Used to create/delete entries" ::= { rcCfmTrunkGroupEntry 2} rcCfmTrunkGroupPrimaryTrunk OBJECT-TYPE SYNTAX DisplayString(SIZE(32)) MAX-ACCESS read-create STATUS current DESCRIPTION "Trunk Group PBT Primary Trunk Name" ::= { rcCfmTrunkGroupEntry 3} rcCfmTrunkGroupSecondaryTrunk OBJECT-TYPE SYNTAX DisplayString(SIZE(32)) MAX-ACCESS read-create STATUS current DESCRIPTION "Trunk Group PBT Secondary Trunk Name" ::= { rcCfmTrunkGroupEntry 4} rcCfmTrunkGroupActiveTrunk OBJECT-TYPE SYNTAX DisplayString(SIZE(32)) MAX-ACCESS read-create STATUS current DESCRIPTION "Trunk Group PBT Active Trunk Name" ::= { rcCfmTrunkGroupEntry 5} rcCfmTrunkGroupRevertive OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Revertive enable or disable" DEFVAL { disable } ::= { rcCfmTrunkGroupEntry 6} rcCfmTrunkGroupLoopBackVlanId OBJECT-TYPE SYNTAX Integer32 (0..4094) MAX-ACCESS read-create STATUS current DESCRIPTION "Loopback VLAN ID for local pbt switching" ::= { rcCfmTrunkGroupEntry 7} rcCfmTrunkGroupUserLabel1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..89)) MAX-ACCESS read-write STATUS current DESCRIPTION "User provided field. Used to give extra management information/data " ::= { rcCfmTrunkGroupEntry 8 } rcCfmTrunkGroupUserLabel2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..89)) MAX-ACCESS read-write STATUS current DESCRIPTION "User provided additional field. Used to give extra management information/data " ::= { rcCfmTrunkGroupEntry 9} -- Trunk Table rcCfmTrunkTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmTrunkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Trunk table" ::= { rcCfm 5} rcCfmTrunkEntry OBJECT-TYPE SYNTAX RcCfmTrunkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management Trunk entry." INDEX {rcCfmTrunkName} ::= { rcCfmTrunkTable 1} RcCfmTrunkEntry ::= SEQUENCE { rcCfmTrunkName CfmNameString, rcCfmTrunkPort InterfaceIndex, rcCfmTrunkAdminState EnableValue, rcCfmTrunkRowStatus RowStatus, rcCfmTrunkMac MacAddress, rcCfmTrunkMdName DisplayString, rcCfmTrunkMaName DisplayString, rcCfmTrunkVlanId Integer32, rcCfmTrunkReverseVlanId Integer32, rcCfmTrunkMepId Integer32, rcCfmTrunkHoldTimer Integer32, rcCfmTrunkOperStatus INTEGER, rcCfmTrunkSourceMac MacAddress, rcCfmTrunkClearStats TruthValue, rcCfmTrunkUserLabel1 OCTET STRING , rcCfmTrunkUserLabel2 OCTET STRING , rcCfmTrunkSubportQueueSet Integer32, rcCfmTrunkDualHomePartner EnableValue } rcCfmTrunkName OBJECT-TYPE SYNTAX CfmNameString MAX-ACCESS not-accessible STATUS current DESCRIPTION "PBT Trunk Name" ::= { rcCfmTrunkEntry 1} rcCfmTrunkPort OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "PBT Trunk Port" ::= { rcCfmTrunkEntry 2} rcCfmTrunkAdminState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Administratively enable or disable a PBT trunk." DEFVAL { disable } ::= { rcCfmTrunkEntry 3} rcCfmTrunkRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Used to create/delete entries" ::= { rcCfmTrunkEntry 4} rcCfmTrunkMac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Trunk Mac (remote CP mac)" ::= { rcCfmTrunkEntry 5} rcCfmTrunkMdName OBJECT-TYPE SYNTAX DisplayString(SIZE(255)) MAX-ACCESS read-create STATUS current DESCRIPTION "PBT Trunk Maintenance Domain Name" ::= { rcCfmTrunkEntry 6} rcCfmTrunkMaName OBJECT-TYPE SYNTAX DisplayString(SIZE(255)) MAX-ACCESS read-create STATUS current DESCRIPTION "PBT Trunk Maintenance Association Name" ::= { rcCfmTrunkEntry 7} rcCfmTrunkVlanId OBJECT-TYPE SYNTAX Integer32 (0..4095) MAX-ACCESS read-create STATUS current DESCRIPTION "PBT trunk VLAN ID" ::= { rcCfmTrunkEntry 8} rcCfmTrunkReverseVlanId OBJECT-TYPE SYNTAX Integer32 (0..4095) MAX-ACCESS read-create STATUS current DESCRIPTION "PBT trunk reverse VLAN ID" ::= { rcCfmTrunkEntry 9} rcCfmTrunkMepId OBJECT-TYPE SYNTAX Integer32 (0..8191) MAX-ACCESS read-create STATUS current DESCRIPTION "PBT trunk MEP ID. Range 1-8191 is a valid Mep ID to be assigned to the CFM Trunk. '0' means unassign the Med ID from the CFM Trunk" ::= { rcCfmTrunkEntry 10} rcCfmTrunkHoldTimer OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Trunk hold timer value." ::= { rcCfmTrunkEntry 11 } rcCfmTrunkOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), waiting(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current operational status of this trunk." DEFVAL { down } ::= { rcCfmTrunkEntry 12 } rcCfmTrunkSourceMac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Trunk Source Mac (local switch PBT mac)" ::= { rcCfmTrunkEntry 13} rcCfmTrunkClearStats OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "Action to clear the stats for all trunks" DEFVAL { false } ::= { rcCfmTrunkEntry 14} rcCfmTrunkUserLabel1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..89)) MAX-ACCESS read-write STATUS current DESCRIPTION "User provided field. Used to give extra management information/data " ::= { rcCfmTrunkEntry 15 } rcCfmTrunkUserLabel2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..89)) MAX-ACCESS read-write STATUS current DESCRIPTION "User provided additional field. Used to give extra management information/data " ::= { rcCfmTrunkEntry 16 } rcCfmTrunkSubportQueueSet OBJECT-TYPE SYNTAX Integer32 (1..80) MAX-ACCESS read-create STATUS current DESCRIPTION "Subport Queue Set Index Number" DEFVAL { 1 } ::= { rcCfmTrunkEntry 17} rcCfmTrunkDualHomePartner OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Enable PBT trunk as Dual Home Partner" DEFVAL { disable } ::= { rcCfmTrunkEntry 18} -- Service Group Table rcCfmServiceGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmServiceGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Service Group table" ::= { rcCfm 6} rcCfmServiceGroupEntry OBJECT-TYPE SYNTAX RcCfmServiceGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management ServiceGroup entry." INDEX {rcCfmServiceGroupName} ::= { rcCfmServiceGroupTable 1} RcCfmServiceGroupEntry ::= SEQUENCE { rcCfmServiceGroupName CfmNameString, rcCfmServiceGroupPort InterfaceIndex, rcCfmServiceGroupAdminState EnableValue, rcCfmServiceGroupRowStatus RowStatus, rcCfmServiceGroupMac MacAddress, rcCfmServiceGroupMdName DisplayString, rcCfmServiceGroupMaName DisplayString, rcCfmServiceGroupTgName DisplayString, rcCfmServiceGroupMepId Integer32, rcCfmServiceGroupRingId Integer32, rcCfmServiceGroupCcmOperStatus INTEGER } rcCfmServiceGroupName OBJECT-TYPE SYNTAX CfmNameString MAX-ACCESS not-accessible STATUS current DESCRIPTION "PBT ServiceGroup Name" ::= { rcCfmServiceGroupEntry 1} rcCfmServiceGroupPort OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "PBT ServiceGroup Port" ::= { rcCfmServiceGroupEntry 2} rcCfmServiceGroupAdminState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Administratively enable or disable a PBT Service Group." DEFVAL { disable } ::= { rcCfmServiceGroupEntry 3} rcCfmServiceGroupRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Used to create/delete entries" ::= { rcCfmServiceGroupEntry 4} rcCfmServiceGroupMac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "ServiceGroup Mac (remote mac of NPU)" ::= { rcCfmServiceGroupEntry 5} rcCfmServiceGroupMdName OBJECT-TYPE SYNTAX DisplayString(SIZE(255)) MAX-ACCESS read-create STATUS current DESCRIPTION "PBT ServiceGroup Maintenance Domain Name" ::= { rcCfmServiceGroupEntry 6} rcCfmServiceGroupMaName OBJECT-TYPE SYNTAX DisplayString(SIZE(255)) MAX-ACCESS read-create STATUS current DESCRIPTION "PBT ServiceGroup Maintenance Association Name" ::= { rcCfmServiceGroupEntry 7} rcCfmServiceGroupTgName OBJECT-TYPE SYNTAX DisplayString(SIZE(32)) MAX-ACCESS read-create STATUS current DESCRIPTION "PBT ServiceGroup Trunk Group Name" ::= { rcCfmServiceGroupEntry 8} rcCfmServiceGroupMepId OBJECT-TYPE SYNTAX Integer32 (0..8191) MAX-ACCESS read-create STATUS current DESCRIPTION "PBT ServiceGroup MEP ID. Range 1-8191 is a valid Mep ID to be assigned to the CFM Service group. '0' means unassign the Med ID from the CFM service group" ::= { rcCfmServiceGroupEntry 9} rcCfmServiceGroupRingId OBJECT-TYPE SYNTAX Integer32 (0..254) MAX-ACCESS read-create STATUS current DESCRIPTION "Ring ID associated with Service Group" DEFVAL { 0 } ::= { rcCfmServiceGroupEntry 10} rcCfmServiceGroupCcmOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current CCM operational status of this service group." ::= { rcCfmServiceGroupEntry 11 } -- PBT Vlans Table rcCfmPbt OBJECT IDENTIFIER ::= {rcCfm 7} rcCfmPbtVlans OBJECT-TYPE SYNTAX OCTET STRING(SIZE(512)) MAX-ACCESS read-write STATUS current DESCRIPTION "Connectivity Fault Management PBT vlan entry." ::= { rcCfmPbt 1} rcCfmPbtMsti OBJECT-TYPE SYNTAX Integer32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "MSTI instance ID for PBT VLANS" DEFVAL { 0 } ::= { rcCfmPbt 2} --- CFM Stats Table rcCfmStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM stats table" ::= { rcCfm 8 } rcCfmStatsEntry OBJECT-TYPE SYNTAX RcCfmStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Stats table entry. Contain CFM Message sending/receiving and missing counter" INDEX { rcCfmStatsDomainIndex, rcCfmStatsAssociationIndex, rcCfmStatsMepId} ::= { rcCfmStatsTable 1 } RcCfmStatsEntry ::= SEQUENCE { rcCfmStatsDomainIndex Integer32, rcCfmStatsAssociationIndex Integer32, rcCfmStatsDomainName DisplayString, rcCfmStatsAssociationName DisplayString, rcCfmStatsMepId Integer32, rcCfmStatsTxCnt Counter64, rcCfmStatsRxCnt Counter64, rcCfmStatsRxZeroCnt Counter64, rcCfmStatsMissedCnt Counter64, rcCfmStatsUpTimeCnt Counter64, rcCfmStatsDefect Integer32, rcCfmStatsAisTxCnt Counter64, rcCfmStatsAisRxCnt Counter64, rcCfmStatsAisOperState INTEGER, rcCfmStatsAisMipLevel Integer32, rcCfmStatsIfTlvTx INTEGER, rcCfmStatsAccessDrops Counter64, rcCfmStatsAggregateUplinkDrops Counter64 } rcCfmStatsDomainIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmStatsEntry 1} rcCfmStatsAssociationIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmStatsEntry 2} rcCfmStatsDomainName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmStatsEntry 3} rcCfmStatsAssociationName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmStatsEntry 4} rcCfmStatsMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance EndPoint ID" ::= { rcCfmStatsEntry 5} rcCfmStatsTxCnt OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of CFM messages are transmitted by trunk or ESM port" ::= { rcCfmStatsEntry 6} rcCfmStatsRxCnt OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of CFM messages are received by trunk or ESM port" ::= { rcCfmStatsEntry 7 } rcCfmStatsRxZeroCnt OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of CFM messages are received by trunk or ESM port" ::= { rcCfmStatsEntry 8 } rcCfmStatsMissedCnt OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of CFM messages are missing on trunk or ESM port" ::= { rcCfmStatsEntry 9 } rcCfmStatsUpTimeCnt OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Time of CFM messages are UP on trunk or ESM port in milliseconds" ::= { rcCfmStatsEntry 10 } rcCfmStatsDefect OBJECT-TYPE SYNTAX Integer32 (0..5) MAX-ACCESS read-only STATUS current DESCRIPTION "An enumerated value indicating the highest-priority defect that has been present since the MEP Fault Notification Generate State Machine was last in the FNG_RESET state, either: 1) DefRDICCM: The last CCM received by this MEP from some remote MEP contained the RDI bit. 2) DefMACstats: The last CCM received by this MEP from some remote MEP indicated that the transmitting MEP's associated MAC is reporting an error status. 3) DefRemoteCCM: This MEP is not receiving CCMs from some other MEP in its configured list. 4) DefErrorCCM: This MEP is receiving invalid CCMs. 5) DefXconCCM: This MEP is receiving CCMs that could be from some other MA. " ::= { rcCfmStatsEntry 11 } rcCfmStatsAisTxCnt OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of AIS messages transmitted by Client Mep on Port/MLT" ::= { rcCfmStatsEntry 12} rcCfmStatsAisRxCnt OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of AIS messages received by Client Mep on Port/MLT" ::= { rcCfmStatsEntry 13} rcCfmStatsAisOperState OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "To indicate the operational status of AIS. It is set to true when AIS is transmitted. It is set to false when AIS is cleared." ::= { rcCfmStatsEntry 14} rcCfmStatsAisMipLevel OBJECT-TYPE SYNTAX Integer32(0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "This is Maintenance Domain Level of the MIP on which the AIS is transmitted." ::= { rcCfmStatsEntry 15} rcCfmStatsIfTlvTx OBJECT-TYPE SYNTAX INTEGER { none(1), up(2), down(3), lowerLayerDown(4), testing(5), unknown(6), dormant(7), notpresent(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "To indicate the operational state of Interface Status TLV transmitted on MaintenanceEndpoint. This status indicates that the state of the local UNI Port." ::= { rcCfmStatsEntry 16 } rcCfmStatsAccessDrops OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets dropped on ingress to access port, for this MEP, due to same or lower MD level" ::= { rcCfmStatsEntry 17 } rcCfmStatsAggregateUplinkDrops OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets dropped on ingress to uplink port, for all MEPS, due to lower MD level" ::= { rcCfmStatsEntry 18 } -- CCM operational indication rcCfmTrap OBJECT IDENTIFIER ::= { rcCfm 9 } rcCfmTrunkCcmIndication OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " A Trunk CCM indication signifies that the trunk CCM operational status has changed state to UP or DOWN" ::= { rcCfmTrap 1 } rcCfmServiceGroupCcmIndication OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " A Service Group CCM indication signifies that the service group CCM operational status has changed state to UP or DOWN" ::= { rcCfmTrap 2 } rcCfmEndPointCcmIndication OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " A Endpoint CCM indication signifies that the endpoint CCM operational status has changed state to UP or DOWN" ::= { rcCfmTrap 3 } rcCfmTrunkGroupIndication OBJECT-TYPE SYNTAX INTEGER { majorFailure(1), primaryFailed(2), secondaryFailed(3), manualSwitched(4), reversion(5) } MAX-ACCESS read-only STATUS current DESCRIPTION " A Trunk group CCM indication signifies what kind of protection failure within the trunk group" ::= { rcCfmTrap 4 } rcCfmTrunkGroupProtected OBJECT-TYPE SYNTAX INTEGER { wasprotected(1), wasnotprotected(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " signifies trunk group was protected or was not protected" ::= { rcCfmTrap 5 } rcCfmRemoteMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Maintenance Endpoint ID" ::= {rcCfmTrap 6} rcCfmLocalMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS read-only STATUS current DESCRIPTION "Local Maintenance Endpoint ID" ::= {rcCfmTrap 7} rcCfmMepCcmIndication OBJECT-TYPE SYNTAX INTEGER { down(1), up(2), learned(3), update(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "CCM indication signifies that the MEP CCM operational status" ::= {rcCfmTrap 8} rcCfmCvid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "A value that uniquely identifies the Customer Vlan Id in i-sid endpt." ::= { rcCfmTrap 9 } rcCfmRemoteMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "remote MAC address" ::= { rcCfmTrap 10} rcCfmIsidId OBJECT-TYPE SYNTAX Integer32 (1..16777215) MAX-ACCESS read-only STATUS current DESCRIPTION "Service Instance ID of the I component" ::= { rcCfmTrap 11 } rcCfmTrapTrunkName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "PBT Trunk Name" ::= { rcCfmTrap 12} rcCfmPbitNum OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION " p-bit value used to queue packets" ::= { rcCfmTrap 13 } rcCfmUserLabel1 OBJECT-TYPE SYNTAX DisplayString(SIZE(0..80)) MAX-ACCESS read-only STATUS current DESCRIPTION "Memo field " REFERENCE "MERS v4.2 PRD" ::= { rcCfmTrap 14} rcCfmUserLabel2 OBJECT-TYPE SYNTAX DisplayString(SIZE(0..80)) MAX-ACCESS read-only STATUS current DESCRIPTION "Memo field " REFERENCE "MERS v4.2 PRD" ::= { rcCfmTrap 15} rcCfmMonitorCosPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Monitor customer traffic on COS priority" ::= {rcCfmTrap 16} rcCfmThresholdIndication OBJECT-TYPE SYNTAX INTEGER { exceeded(1), recovered(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " A threshold indication is: alarm - when the set-threshold has been exceeded clear - when the clear-threshold level has been reached after an alarm condition " ::= { rcCfmTrap 17 } rcCfmActualPercentage OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured Percentage in 1 percent increments" ::= { rcCfmTrap 18} rcCfmActualSubPercentage OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured Sub percentage in 1/100 percent increments" ::= { rcCfmTrap 19} rcCfmAlarmThreshold OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Configured alarm percentage threshold" ::= { rcCfmTrap 20} rcCfmAlarmSubThreshold OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Configured alarm sub percentage threshold" ::= { rcCfmTrap 21} rcCfmClearThreshold OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Configured clear percentage threshold" ::= { rcCfmTrap 22} rcCfmClearSubThreshold OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Configured clear sub percentage threshold" ::= { rcCfmTrap 23} rcCfmFdTarget OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "frame delay target" ::= { rcCfmTrap 24} rcCfmFdAverage OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "frame delay average" ::= { rcCfmTrap 25} rcCfmTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time stamp." ::= { rcCfmTrap 26} rcCfmTrapTrunkGroupName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "trunk group name." ::= { rcCfmTrap 27} rcCfmVid OBJECT-TYPE SYNTAX Integer32 (0..4096) MAX-ACCESS read-only STATUS current DESCRIPTION "A value that uniquely identifies the Customer Vlan Id in i-sid endpt." ::= { rcCfmTrap 28 } rcCfmFdvTarget OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "frame delay variation target" ::= { rcCfmTrap 29} rcCfmFdvAverage OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "frame delay variation average" ::= { rcCfmTrap 30} rcCfmDirection OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " MEP direction" ::= { rcCfmTrap 31 } rcCfmDhuId OBJECT-TYPE SYNTAX Integer32 (1..254) MAX-ACCESS read-only STATUS current DESCRIPTION "A value that uniquely identifies the DH Uni Id in i-sid endpt." ::= { rcCfmTrap 32 } rcCfmIftlvIndication OBJECT-TYPE SYNTAX INTEGER { down(1), up(2) } MAX-ACCESS read-only STATUS current DESCRIPTION " A Iftlv indication signifies that the operational status of CCM that is sent or received with iftlv has changed state to UP or DOWN" ::= { rcCfmTrap 33 } rcCfmGlobals OBJECT IDENTIFIER ::= { rcCfm 10 } rcCfmGlobalsEtherType OBJECT-TYPE SYNTAX Integer32 (1..'FFFF'h) MAX-ACCESS read-write STATUS current DESCRIPTION "CFM Ether Type" DEFVAL { '8902'h } ::= { rcCfmGlobals 1 } rcCfmGlobalsPbtMac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "PBT base MAC address" ::= { rcCfmGlobals 2 } rcCfmGlobalsPortVid OBJECT-TYPE SYNTAX Integer32 (0..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "CFM default port vid, 4095 is used for untagged." ::= { rcCfmGlobals 3 } rcCfmGlobalsPbtDropTrapTimer OBJECT-TYPE SYNTAX Integer32 (1..1440) MAX-ACCESS read-write STATUS current DESCRIPTION "The timer settings for traps being sent on discard of packets with unknown destination MAC in minutes" DEFVAL { 900 } ::= { rcCfmGlobals 4 } rcCfmGlobalsPmEnable OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "Performance monitor enable" REFERENCE "MERS v4.2 PRD" DEFVAL {enable} ::= { rcCfmGlobals 5 } rcCfmGlobalsCcmTrapDisplayEnable OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "CCM trap display enable" DEFVAL {enable} ::= { rcCfmGlobals 6 } rcCfmGlobalsPmLogEnable OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable PM Auto Logging" DEFVAL {disable} ::= { rcCfmGlobals 7 } -- Remote Maintenance EndPoint Table rcCfmRemoteMepConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmRemoteMepConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management Remote Maintenance Association table" ::= { rcCfm 11} rcCfmRemoteMepConfigEntry OBJECT-TYPE SYNTAX RcCfmRemoteMepConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management Remote Maintenance EndPoint entry." INDEX {rcCfmRemoteMepConfigDomainIndex, rcCfmRemoteMepConfigAssociationIndex, rcCfmRemoteMepConfigId } ::= { rcCfmRemoteMepConfigTable 1} RcCfmRemoteMepConfigEntry ::= SEQUENCE { rcCfmRemoteMepConfigDomainIndex Integer32, rcCfmRemoteMepConfigAssociationIndex Integer32, rcCfmRemoteMepConfigId Integer32, rcCfmRemoteMepConfigDomainName DisplayString, rcCfmRemoteMepConfigAssociationName DisplayString, rcCfmRemoteMepConfigMacAddr MacAddress, rcCfmRemoteMepConfigRowStatus RowStatus } rcCfmRemoteMepConfigDomainIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Remote Maintenance Domain Name" ::= { rcCfmRemoteMepConfigEntry 1} rcCfmRemoteMepConfigAssociationIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Remote Maintenance Association Name" ::= { rcCfmRemoteMepConfigEntry 2} rcCfmRemoteMepConfigId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Remote Maintenance EndPoint ID" ::= { rcCfmRemoteMepConfigEntry 3} rcCfmRemoteMepConfigDomainName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Maintenance Domain Name" ::= { rcCfmRemoteMepConfigEntry 4} rcCfmRemoteMepConfigAssociationName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Remote Maintenance Association Name" ::= { rcCfmRemoteMepConfigEntry 5} rcCfmRemoteMepConfigMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Mac address of remote maintenance endpoint" ::= { rcCfmRemoteMepConfigEntry 6} rcCfmRemoteMepConfigRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Used to create/delete entries" ::= { rcCfmRemoteMepConfigEntry 7} -- Remote Mep Learn Stats RcCfmRemoteMepState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Operational state of the remote MEP state machine" REFERENCE "802.1ag clauses 12.14.7.6.3 b), 20.16 and 20.17" SYNTAX INTEGER { rMepIdle (1), rMepStart (2), rMepFailed (3), rMepOk (4) } RcCfmPmOperState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Operational state of the Performance Montitor form mep-rmep pair" SYNTAX INTEGER { rPmUp (1), rPmDown (2), rPmError (3), rPmSync (4) } rcCfmRemoteMepStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmRemoteMepStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Mep Learn stats table contains the local and remote mep Tx and Rx statistics" ::= { rcCfm 12 } rcCfmRemoteMepStatsEntry OBJECT-TYPE SYNTAX RcCfmRemoteMepStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Stats table entry. Contain CFM Message sending/receiving and missing counter. Entry indicate the CCM message still alive" INDEX { rcCfmRemoteMepStatsDomainIndex, rcCfmRemoteMepStatsAssociationIndex, rcCfmRemoteMepStatsMepId, rcCfmRemoteMepStatsRemoteMepId} ::= { rcCfmRemoteMepStatsTable 1 } RcCfmRemoteMepStatsEntry ::= SEQUENCE { rcCfmRemoteMepStatsDomainIndex Integer32, rcCfmRemoteMepStatsAssociationIndex Integer32, rcCfmRemoteMepStatsMepId Integer32, rcCfmRemoteMepStatsRemoteMepId Integer32, rcCfmRemoteMepStatsDomainName DisplayString, rcCfmRemoteMepStatsAssociationName DisplayString, rcCfmRemoteMepStatsLearnType INTEGER, rcCfmRemoteMepStatsRemoteMacAddr MacAddress, rcCfmRemoteMepStatsRxCnt Counter64, rcCfmRemoteMepStatsSeqErrCnt Counter64, rcCfmRemoteMepStatsOperState INTEGER, rcCfmRemoteMepStatsClearStats TruthValue, rcCfmRemoteMepStatsDbRdi TruthValue, rcCfmRemoteMepStatsIfTlvRx INTEGER } rcCfmRemoteMepStatsDomainIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Domain Name index" ::= { rcCfmRemoteMepStatsEntry 1} rcCfmRemoteMepStatsAssociationIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Association Name index" ::= { rcCfmRemoteMepStatsEntry 2} rcCfmRemoteMepStatsMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Local MEP (Maintenance EndPoint) ID" ::= { rcCfmRemoteMepStatsEntry 3} rcCfmRemoteMepStatsRemoteMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Remote Mep Id which the local mep rx CCM message from" ::= { rcCfmRemoteMepStatsEntry 4} rcCfmRemoteMepStatsDomainName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmRemoteMepStatsEntry 5} rcCfmRemoteMepStatsAssociationName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmRemoteMepStatsEntry 6} rcCfmRemoteMepStatsLearnType OBJECT-TYPE SYNTAX INTEGER { static(1), dynamic(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate the learning remote Mep is static created or dynamic learn" ::= { rcCfmRemoteMepStatsEntry 7} rcCfmRemoteMepStatsRemoteMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "A remote MAC address" ::= { rcCfmRemoteMepStatsEntry 8 } rcCfmRemoteMepStatsRxCnt OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of CFM messages are received by trunk or ESM port" ::= { rcCfmRemoteMepStatsEntry 9 } rcCfmRemoteMepStatsSeqErrCnt OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of Sequence errors" ::= { rcCfmRemoteMepStatsEntry 10} rcCfmRemoteMepStatsOperState OBJECT-TYPE SYNTAX INTEGER { start(1), up(2), down(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "To indicate the operational state of remote maintenance endpoint" ::= { rcCfmRemoteMepStatsEntry 11 } rcCfmRemoteMepStatsClearStats OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "To clear the CCM messages counter" DEFVAL { false } ::= { rcCfmRemoteMepStatsEntry 12 } rcCfmRemoteMepStatsDbRdi OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "State of the RDI bit in the last received CCM (true for RDI=1), or false if none has been received." REFERENCE "802.1ag clauses 12.14.7.6.3 and 20.15.2" ::= { rcCfmRemoteMepStatsEntry 13 } rcCfmRemoteMepStatsIfTlvRx OBJECT-TYPE SYNTAX INTEGER { none(1), up(2), down(3), lowerLayerDown(4), testing(5), unknown(6), dormant(7), notpresent(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "To indicate the operational state of Interface Status TLV received on MaintenanceEndpoint. This status indicates that the state of the remote UNI Port" ::= { rcCfmRemoteMepStatsEntry 14 } -- Maintenance Intermediate Point Table -- Maintenance Intermediate Point Table rcCfmMaintenanceIntermediatePointTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmMaintenanceIntermediatePointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management Maintenance Intermediate Point table" ::= { rcCfm 13} rcCfmMaintenanceIntermediatePointEntry OBJECT-TYPE SYNTAX RcCfmMaintenanceIntermediatePointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management Maintenance Intermediate Point entry." INDEX {rcCfmMaintenanceIntermediatePointDomainIndex, rcCfmMaintenanceIntermediatePointId } ::= { rcCfmMaintenanceIntermediatePointTable 1} RcCfmMaintenanceIntermediatePointEntry ::= SEQUENCE { rcCfmMaintenanceIntermediatePointDomainIndex Integer32, rcCfmMaintenanceIntermediatePointId Integer32, rcCfmMaintenanceIntermediatePointDomainName DisplayString, rcCfmMaintenanceIntermediatePointRowStatus RowStatus, rcCfmMaintenanceIntermediatePointMipType INTEGER, rcCfmMaintenanceIntermediatePointClearStats TruthValue, rcCfmMaintenanceIntermediatePointServiceDescription DisplayString } rcCfmMaintenanceIntermediatePointDomainIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmMaintenanceIntermediatePointEntry 1} rcCfmMaintenanceIntermediatePointId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance IntermediatePoint ID" ::= { rcCfmMaintenanceIntermediatePointEntry 2} rcCfmMaintenanceIntermediatePointDomainName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmMaintenanceIntermediatePointEntry 3} rcCfmMaintenanceIntermediatePointRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Used to create/delete entries" ::= { rcCfmMaintenanceIntermediatePointEntry 4} rcCfmMaintenanceIntermediatePointMipType OBJECT-TYPE SYNTAX INTEGER { vlan(1), unused(2), endptClient(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Mip Type" ::= { rcCfmMaintenanceIntermediatePointEntry 5 } rcCfmMaintenanceIntermediatePointClearStats OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "To clear the MIP CCM sending/receiving message counter" DEFVAL { false } ::= { rcCfmMaintenanceIntermediatePointEntry 6 } rcCfmMaintenanceIntermediatePointServiceDescription OBJECT-TYPE SYNTAX DisplayString(SIZE (0..48)) MAX-ACCESS read-only STATUS current DESCRIPTION "Used to specify what service this mip assigned to" ::= { rcCfmMaintenanceIntermediatePointEntry 7} --- CFM NNI Table rcCfmNniTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmNniEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM NNI table" ::= { rcCfm 14 } rcCfmNniEntry OBJECT-TYPE SYNTAX RcCfmNniEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM NNI table entry" INDEX { rcCfmNniPort, rcCfmNniServiceId, rcCfmNniPwIndex, rcCfmNniTlsIndex} ::= { rcCfmNniTable 1 } RcCfmNniEntry ::= SEQUENCE { rcCfmNniPort InterfaceIndex, rcCfmNniServiceId Integer32, rcCfmNniPwIndex Integer32, rcCfmNniTlsIndex Integer32, rcCfmNniTgName DisplayString } rcCfmNniPort OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "PBT Trunk Port" ::= { rcCfmNniEntry 1} rcCfmNniServiceId OBJECT-TYPE SYNTAX Integer32 (0..16777215) MAX-ACCESS not-accessible STATUS current DESCRIPTION "TDI or MIM" ::= { rcCfmNniEntry 2} rcCfmNniPwIndex OBJECT-TYPE SYNTAX Integer32 (0..16777215) MAX-ACCESS not-accessible STATUS current DESCRIPTION "PW index" ::= { rcCfmNniEntry 3} rcCfmNniTlsIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Access Port" ::= { rcCfmNniEntry 4} rcCfmNniTgName OBJECT-TYPE SYNTAX DisplayString(SIZE(32)) MAX-ACCESS read-only STATUS current DESCRIPTION "PBT Trunk Group Name" ::= { rcCfmNniEntry 5} --- PBT NNI Stats Table rcCfmNniStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmNniStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM NNI stats table" ::= { rcCfm 15 } rcCfmNniStatsEntry OBJECT-TYPE SYNTAX RcCfmNniStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM NNI Stats table entry. Contain bytes processed and dropped due to lookup failure in the SDT table" INDEX { rcCfmNniStatsPort} ::= { rcCfmNniStatsTable 1 } RcCfmNniStatsEntry ::= SEQUENCE { rcCfmNniStatsPort InterfaceIndex, rcCfmNniStatsOel2RxOctets Counter64, rcCfmNniStatsOel2RxDroppedOctets Counter64, rcCfmNniStatsMimRxOctets Counter64, rcCfmNniStatsMimRxDroppedOctets Counter64, rcCfmNniStatsPweRxOctets Counter64, rcCfmNniStatsPweRxDroppedOctets Counter64 } rcCfmNniStatsPort OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "PBT Trunk Port" ::= { rcCfmNniStatsEntry 1} rcCfmNniStatsOel2RxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of bytes (OEL2 encapsulation) processed on ingress NNI port" ::= { rcCfmNniStatsEntry 2} rcCfmNniStatsOel2RxDroppedOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of bytes (OEL2 encapsulation) dropped on ingress NNI port" ::= { rcCfmNniStatsEntry 3} rcCfmNniStatsMimRxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of bytes (MIM encapsulation) processed on ingress NNI port" ::= { rcCfmNniStatsEntry 4} rcCfmNniStatsMimRxDroppedOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of bytes (MIM encapsulation) dropped on ingress NNI port" ::= { rcCfmNniStatsEntry 5} rcCfmNniStatsPweRxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of bytes (PWE encapsulation) processed on ingress NNI port" ::= { rcCfmNniStatsEntry 6} rcCfmNniStatsPweRxDroppedOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of bytes (PWE encapsulation) dropped on ingress NNI port" ::= { rcCfmNniStatsEntry 7} rcCfmMipStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmMipStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Mip stats table" ::= { rcCfm 16 } rcCfmMipStatsEntry OBJECT-TYPE SYNTAX RcCfmMipStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Mip Stats table entry. Contain CFM Mip message number of receiving/replying loopback & linktrace." INDEX { rcCfmMipStatsDomainIndex, rcCfmMipStatsMipId} ::= { rcCfmMipStatsTable 1 } RcCfmMipStatsEntry ::= SEQUENCE { rcCfmMipStatsDomainIndex Integer32, rcCfmMipStatsDomainName DisplayString, rcCfmMipStatsMipId Integer32, rcCfmMipStatsLoopbackReceived Counter64, rcCfmMipStatsLoopbackReplied Counter64, rcCfmMipStatsLinktraceReceived Counter64, rcCfmMipStatsLinktraceReplied Counter64 } rcCfmMipStatsDomainIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmMipStatsEntry 1} rcCfmMipStatsDomainName OBJECT-TYPE SYNTAX DisplayString(SIZE (22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmMipStatsEntry 2} rcCfmMipStatsMipId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Intermediate Point ID" ::= { rcCfmMipStatsEntry 3} rcCfmMipStatsLoopbackReceived OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of CFM loopback messages received." ::= { rcCfmMipStatsEntry 4 } rcCfmMipStatsLoopbackReplied OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of CFM loopback messages replied." ::= { rcCfmMipStatsEntry 5 } rcCfmMipStatsLinktraceReceived OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of CFM linktrace messages received." ::= { rcCfmMipStatsEntry 6 } rcCfmMipStatsLinktraceReplied OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of CFM linktrace messages replied." ::= { rcCfmMipStatsEntry 7 } -- The Transmit Loopback Table rcCfmTransmitLbmTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmTransmitLbmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management transmit LBM table" ::= { rcCfm 17} rcCfmTransmitLbmEntry OBJECT-TYPE SYNTAX RcCfmTransmitLbmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management Maintenance EndPoint LBM entry." INDEX {rcCfmTransmitLbmDomainIndex, rcCfmTransmitLbmAssociationIndex, rcCfmTransmitLbmIndex } ::= { rcCfmTransmitLbmTable 1} RcCfmTransmitLbmEntry ::= SEQUENCE { rcCfmTransmitLbmDomainIndex Integer32, rcCfmTransmitLbmAssociationIndex Integer32, rcCfmTransmitLbmIndex Integer32, rcCfmTransmitLbmDomainName DisplayString, rcCfmTransmitLbmAssociationName DisplayString, rcCfmTransmitLbmDestMacAddress MacAddress, rcCfmTransmitLbmDestMepId Integer32, rcCfmTransmitLbmDestIsMepId TruthValue, rcCfmTransmitLbmMessages Integer32, rcCfmTransmitLbmVlanPriority Integer32, rcCfmTransmitLbmVlanDropEnable TruthValue, rcCfmTransmitLbmSeqNumber Integer32, rcCfmTransmitLbmResultOk TruthValue, rcCfmTransmitLbmStatus INTEGER, rcCfmTransmitLbmResult DisplayString, rcCfmTransmitLbmMode INTEGER, rcCfmTransmitLbmTimeoutInt Integer32, rcCfmTransmitLbmInterFrameInt Integer32, rcCfmTransmitLbmTestPattern INTEGER, rcCfmTransmitLbmDataSize Integer32, rcCfmTransmitLbmFrameSize Integer32 } rcCfmTransmitLbmDomainIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmTransmitLbmEntry 1} rcCfmTransmitLbmAssociationIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmTransmitLbmEntry 2} rcCfmTransmitLbmIndex OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance EndPoint Index" ::= { rcCfmTransmitLbmEntry 3} rcCfmTransmitLbmDomainName OBJECT-TYPE SYNTAX DisplayString(SIZE (1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmTransmitLbmEntry 4} rcCfmTransmitLbmAssociationName OBJECT-TYPE SYNTAX DisplayString(SIZE (1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmTransmitLbmEntry 5} rcCfmTransmitLbmDestMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "An indication of the target MAC Address Field to be transmitted, either: A unicast destination MAC address." ::= { rcCfmTransmitLbmEntry 6} rcCfmTransmitLbmDestMepId OBJECT-TYPE SYNTAX Integer32 (0..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "An indication of the target MAC Address Field to be transmitted, either: The Maintenance Assiciation End Point identifier of another MEP in the same Maintenance Association" ::= { rcCfmTransmitLbmEntry 7} rcCfmTransmitLbmDestIsMepId OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "True indicates that MepId of the target MEP is used for Loopback transmission. False indicates that unicast destination MAC address of the target MEP is used for Loopback transmission." ::= { rcCfmTransmitLbmEntry 8} rcCfmTransmitLbmMessages OBJECT-TYPE SYNTAX Integer32(1..10000) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of loopback messages to be transmitted." DEFVAL {1} ::= { rcCfmTransmitLbmEntry 9} rcCfmTransmitLbmVlanPriority OBJECT-TYPE SYNTAX Integer32(0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Priority. 3 bit value to be used in the VLAN tsg, if present in the transmitted frame." DEFVAL {7} ::= { rcCfmTransmitLbmEntry 11} rcCfmTransmitLbmVlanDropEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Drop Enable bit value to be used in the VLAN tag, if present in the transmitted frame." DEFVAL {false} ::= { rcCfmTransmitLbmEntry 12} rcCfmTransmitLbmSeqNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transaction identifier/sequence number of the first loopback message (to be) sent." DEFVAL {0} ::= { rcCfmTransmitLbmEntry 13} rcCfmTransmitLbmResultOk OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the result of the operation: -true. The Loopback Message(s) will be (or have been) sent. -false. The Loopback Message(s) will not be sent." DEFVAL {true} ::= { rcCfmTransmitLbmEntry 14} rcCfmTransmitLbmStatus OBJECT-TYPE SYNTAX INTEGER { ready(1), transmit(2), abort(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Status of the transmit loopback service: -ready. The service is available. -transmit. The service is transmitting, or about to transmit, the Loopback messages. -abort The service is aborted or about to abort the Loopback messages. This column will also be used to avoid concurrency or race condition problems that could occur if two or more management entities try to use the service at the sane time. " REFERENCE "Delete notReady status due to CR Q01482201" DEFVAL {ready} ::= { rcCfmTransmitLbmEntry 15} rcCfmTransmitLbmResult OBJECT-TYPE SYNTAX DisplayString(SIZE (1..799)) MAX-ACCESS read-only STATUS current DESCRIPTION "Display the LBM result." ::= { rcCfmTransmitLbmEntry 16} rcCfmTransmitLbmMode OBJECT-TYPE SYNTAX INTEGER { throughput(1), roundTripTime(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Modes of the transmit loopback service: throughput: The throughput mode of operation. LBM Frame will be sent out at the configured transmit interval rate for the burst-count number. roundTripTime: The RoundTripTime mode of operation. LBM Frame will be sent out one at a time and the transmit time will be recorded locally. " DEFVAL {throughput} ::= { rcCfmTransmitLbmEntry 17} rcCfmTransmitLbmTimeoutInt OBJECT-TYPE SYNTAX Integer32(1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "The interval to wait for an LBM time-out with a range of (1..10) seconds with a default value of 3 seconds." DEFVAL {3} ::= { rcCfmTransmitLbmEntry 18} rcCfmTransmitLbmInterFrameInt OBJECT-TYPE SYNTAX Integer32(0..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "The interval between LBM frames with a range of (0..1000) msecs with a default value of 500 msecs. The value of 0 msecs indicates to send the frames as fast as possible." DEFVAL {500} ::= { rcCfmTransmitLbmEntry 19} rcCfmTransmitLbmTestPattern OBJECT-TYPE SYNTAX INTEGER { allZero(0), allZeroCrc(1), pseudoRandomBitSequence(2), pseudoRandomBitSequenceCrc(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The test pattern to use in the LBM PDU with range of values namely allZero, allZeroCrc, pseudoRandomBitSequence and pseudoRandomBitSequenceCrc and with a default value of allZero. value meaning -------- ------- allZero(0) Null signal without CRC-32 allZeroCrc(1) Null signal with CRC-32 pseudoRandomBitSequence(2) PRBS 1/2^31-1 without CRC-32 pseudoRandomBitSequenceCrc(3) PBRS 1/2^31-1 with CRC-32" DEFVAL {allZero} ::= { rcCfmTransmitLbmEntry 20} rcCfmTransmitLbmDataSize OBJECT-TYPE SYNTAX Integer32(0..400) MAX-ACCESS read-write STATUS current DESCRIPTION "An arbitrary amount of data to be included in the data TLV, if the Data Size is selected to be sent." DEFVAL {0} ::= { rcCfmTransmitLbmEntry 21} rcCfmTransmitLbmFrameSize OBJECT-TYPE SYNTAX Integer32(0..9600) MAX-ACCESS read-write STATUS current DESCRIPTION "If the frame size (64-500 for R-Mod and 64-9600 for RC-Mod)is specified then the data size shall be internally calculated and the calculated data size shall be included in the data TLV." DEFVAL {0} ::= { rcCfmTransmitLbmEntry 22} -- The Transmit Linktrace Table rcCfmTransmitLtmTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmTransmitLtmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management transmit LBM table" ::= { rcCfm 18} rcCfmTransmitLtmEntry OBJECT-TYPE SYNTAX RcCfmTransmitLtmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management Maintenance EndPoint LTM entry." INDEX {rcCfmTransmitLtmDomainIndex, rcCfmTransmitLtmAssociationIndex, rcCfmTransmitLtmIndex } ::= { rcCfmTransmitLtmTable 1} RcCfmTransmitLtmEntry ::= SEQUENCE { rcCfmTransmitLtmDomainIndex Integer32, rcCfmTransmitLtmAssociationIndex Integer32, rcCfmTransmitLtmIndex Integer32, rcCfmTransmitLtmDomainName DisplayString, rcCfmTransmitLtmAssociationName DisplayString, rcCfmTransmitLtmVlanPriority Integer32, rcCfmTransmitLtmDestMacAddress MacAddress, rcCfmTransmitLtmDestMepId Integer32, rcCfmTransmitLtmDestIsMepId TruthValue, rcCfmTransmitLtmTtl Integer32, rcCfmTransmitLtmSeqNumber Integer32, rcCfmTransmitLtmResultOk TruthValue, rcCfmTransmitLtmStatus INTEGER, rcCfmTransmitLtmResult DisplayString, rcCfmTransmitLtmFlag INTEGER } rcCfmTransmitLtmDomainIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmTransmitLtmEntry 1} rcCfmTransmitLtmAssociationIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmTransmitLtmEntry 2} rcCfmTransmitLtmIndex OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance EndPoint Index" ::= { rcCfmTransmitLtmEntry 3} rcCfmTransmitLtmDomainName OBJECT-TYPE SYNTAX DisplayString(SIZE (1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmTransmitLtmEntry 4} rcCfmTransmitLtmAssociationName OBJECT-TYPE SYNTAX DisplayString(SIZE (1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmTransmitLtmEntry 5} rcCfmTransmitLtmVlanPriority OBJECT-TYPE SYNTAX Integer32(0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Priority. 3 bit value to be used in the VLAN tag, if present in the transmitted frame." DEFVAL {7} ::= { rcCfmTransmitLtmEntry 6} rcCfmTransmitLtmDestMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "An indication of the target MAC Address Field to be transmitted, either: A unicast destination MAC address." ::= { rcCfmTransmitLtmEntry 7} rcCfmTransmitLtmDestMepId OBJECT-TYPE SYNTAX Integer32 (0..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "An indication of the target MAC Address Field to be transmitted, either: The Maintenance Assiciation End Point identifier of another MEP in the same Maintenance Association" ::= { rcCfmTransmitLtmEntry 8} rcCfmTransmitLtmDestIsMepId OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "True indicates that MepId of the target MEP is used for Loopback transmission. False indicates that unicast destination MAC address of the target MEP is used for Loopback transmission." ::= { rcCfmTransmitLtmEntry 9} rcCfmTransmitLtmTtl OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of hops remaining to this LTM. Decremented by 1 by each Bridge that handles the LTM. The decremented value is returned in the LTR. If 0 on output, the LTM is not transmitted to the next hop. The value of the TTL Field in the LTM transmitted by the originating MEP is controlled by a Managed Object; The default value if none is specified is 64." DEFVAL {64} ::= { rcCfmTransmitLtmEntry 10} rcCfmTransmitLtmSeqNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transaction identifier/sequence number of the first loopback message (to be) sent." DEFVAL {0} ::= { rcCfmTransmitLtmEntry 11} rcCfmTransmitLtmResultOk OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the result of the operation: -true. The Loopback Message(s) will be (or have been) sent. -false. The Loopback Message(s) will not be sent." DEFVAL {true} ::= { rcCfmTransmitLtmEntry 12} rcCfmTransmitLtmStatus OBJECT-TYPE SYNTAX INTEGER { ready(1), transmit(2), abort(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Status of the transmit loopback service: -ready. The service is available. -transmit. The service is transmitting, or about to transmit, the Loopback messages. -abort. The service is aborted, or about to abort the LTM message This column will also be used to avoid concurrency or race condition problems that could occur if two or more management entities try to use the service at the sane time. " REFERENCE "Delete notReady status due to CR Q01482201" DEFVAL {ready} ::= { rcCfmTransmitLtmEntry 13} rcCfmTransmitLtmResult OBJECT-TYPE SYNTAX DisplayString(SIZE (1..1023)) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Display the LTM result." ::= { rcCfmTransmitLtmEntry 14} rcCfmTransmitLtmFlag OBJECT-TYPE SYNTAX INTEGER { none(1), internalError(2), noRemoteMep(3), invalidRemoteMepMac(4), noRemoteMepMacLearned(5), mepDisabled(6), noLtrResponse(7), ltmToOwnMepMac(8), epDisabled(9), trunkDisabled(10), ltmComplete(11) } MAX-ACCESS read-only STATUS current DESCRIPTION "LTM result flag indicating LTM status or error code. Each enum value represents a status or error case. 1 - No error 2 - Ltm Internal Error 3 - Unknown Remote Maintenance End Point 4 - Invalid Remote Maintenance End Point Mac Address 5 - Unset Remote Maintenance End Point Mac Address 6 - Mep must be enabled in order to perform LTM 7 - No Ltr response received 8 - Linktrace to own Mep MAC is not sent 9 - Endpoint must be enabled in order to perform LTM 10 - Pbt-trunk must be enabled in order to perform LTM 11 - LTM completed" ::= { rcCfmTransmitLtmEntry 15} rcCfmPbtTrunkStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmPbtTrunkStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of PBT trunk statistics." ::= { rcCfm 19 } rcCfmPbtTrunkStatsEntry OBJECT-TYPE SYNTAX RcCfmPbtTrunkStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A PBT Trunk Statistics table entry." INDEX { rcCfmPbtTrunkStatsName } ::= { rcCfmPbtTrunkStatsTable 1 } RcCfmPbtTrunkStatsEntry ::= SEQUENCE { rcCfmPbtTrunkStatsName CfmNameString, rcCfmPbtTrunkStatsPort InterfaceIndex, rcCfmPbtTrunkStatsDA MacAddress, rcCfmPbtTrunkStatsVlanId Integer32, rcCfmPbtTrunkStatsRevVlanId Integer32, rcCfmPbtTrunkStatsSA MacAddress, rcCfmPbtTrunkStatsRxOctets Counter64, rcCfmPbtTrunkStatsRxFrames Counter64, rcCfmPbtTrunkStatsTxOctets Counter64, rcCfmPbtTrunkStatsTxFrames Counter64, rcCfmPbtTrunkStatsRxPbit0Octets Counter64, rcCfmPbtTrunkStatsRxPbit0Frames Counter64, rcCfmPbtTrunkStatsRxPbit1Octets Counter64, rcCfmPbtTrunkStatsRxPbit1Frames Counter64, rcCfmPbtTrunkStatsRxPbit2Octets Counter64, rcCfmPbtTrunkStatsRxPbit2Frames Counter64, rcCfmPbtTrunkStatsRxPbit3Octets Counter64, rcCfmPbtTrunkStatsRxPbit3Frames Counter64, rcCfmPbtTrunkStatsRxPbit4Octets Counter64, rcCfmPbtTrunkStatsRxPbit4Frames Counter64, rcCfmPbtTrunkStatsRxPbit5Octets Counter64, rcCfmPbtTrunkStatsRxPbit5Frames Counter64, rcCfmPbtTrunkStatsRxPbit6Octets Counter64, rcCfmPbtTrunkStatsRxPbit6Frames Counter64, rcCfmPbtTrunkStatsRxPbit7Octets Counter64, rcCfmPbtTrunkStatsRxPbit7Frames Counter64, rcCfmPbtTrunkStatsTxPbit0Octets Counter64, rcCfmPbtTrunkStatsTxPbit0Frames Counter64, rcCfmPbtTrunkStatsTxPbit1Octets Counter64, rcCfmPbtTrunkStatsTxPbit1Frames Counter64, rcCfmPbtTrunkStatsTxPbit2Octets Counter64, rcCfmPbtTrunkStatsTxPbit2Frames Counter64, rcCfmPbtTrunkStatsTxPbit3Octets Counter64, rcCfmPbtTrunkStatsTxPbit3Frames Counter64, rcCfmPbtTrunkStatsTxPbit4Octets Counter64, rcCfmPbtTrunkStatsTxPbit4Frames Counter64, rcCfmPbtTrunkStatsTxPbit5Octets Counter64, rcCfmPbtTrunkStatsTxPbit5Frames Counter64, rcCfmPbtTrunkStatsTxPbit6Octets Counter64, rcCfmPbtTrunkStatsTxPbit6Frames Counter64, rcCfmPbtTrunkStatsTxPbit7Octets Counter64, rcCfmPbtTrunkStatsTxPbit7Frames Counter64 } rcCfmPbtTrunkStatsName OBJECT-TYPE SYNTAX CfmNameString MAX-ACCESS not-accessible STATUS current DESCRIPTION "PBT Trunk Name." ::= { rcCfmPbtTrunkStatsEntry 1 } rcCfmPbtTrunkStatsPort OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "PBT Trunk Port" ::= { rcCfmPbtTrunkStatsEntry 2} rcCfmPbtTrunkStatsDA OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Trunk Mac (remote CP mac)" ::= { rcCfmPbtTrunkStatsEntry 3} rcCfmPbtTrunkStatsVlanId OBJECT-TYPE SYNTAX Integer32 (0..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "PBT trunk VLAN ID" ::= { rcCfmPbtTrunkStatsEntry 4} rcCfmPbtTrunkStatsRevVlanId OBJECT-TYPE SYNTAX Integer32 (0..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "PBT trunk reverse VLAN ID" ::= { rcCfmPbtTrunkStatsEntry 5} rcCfmPbtTrunkStatsSA OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Trunk Source Mac (local switch PBT mac)" ::= { rcCfmPbtTrunkStatsEntry 6} rcCfmPbtTrunkStatsRxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Octets received by the trunk.This does not include trunk CCM messag (control) packets." ::= { rcCfmPbtTrunkStatsEntry 7 } rcCfmPbtTrunkStatsRxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Packets received by the trunk.This does not include trunk CCM messag (control) packets." ::= { rcCfmPbtTrunkStatsEntry 8 } rcCfmPbtTrunkStatsTxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Octets transmitted by the trunk.This does not include trunk CCM messag (control) packets." ::= { rcCfmPbtTrunkStatsEntry 9 } rcCfmPbtTrunkStatsTxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Packets transmitted by the trunk.This does not include trunk CCM messag (control) packets." ::= { rcCfmPbtTrunkStatsEntry 10 } rcCfmPbtTrunkStatsRxPbit0Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Pbit 0 Octets received by the trunk." ::= { rcCfmPbtTrunkStatsEntry 11 } rcCfmPbtTrunkStatsRxPbit0Frames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of P-Bit 0 Packets received by the trunk." ::= { rcCfmPbtTrunkStatsEntry 12 } rcCfmPbtTrunkStatsRxPbit1Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Pbit 1 Octets received by the trunk." ::= { rcCfmPbtTrunkStatsEntry 13 } rcCfmPbtTrunkStatsRxPbit1Frames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of P-Bit 1 Packets received by the trunk." ::= { rcCfmPbtTrunkStatsEntry 14 } rcCfmPbtTrunkStatsRxPbit2Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Pbit 2 Octets received by the trunk." ::= { rcCfmPbtTrunkStatsEntry 15 } rcCfmPbtTrunkStatsRxPbit2Frames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of P-Bit 2 Packets received by the trunk." ::= { rcCfmPbtTrunkStatsEntry 16 } rcCfmPbtTrunkStatsRxPbit3Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Pbit 3 Octets received by the trunk." ::= { rcCfmPbtTrunkStatsEntry 17 } rcCfmPbtTrunkStatsRxPbit3Frames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of P-Bit 3 Packets received by the trunk." ::= { rcCfmPbtTrunkStatsEntry 18 } rcCfmPbtTrunkStatsRxPbit4Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Pbit 4 Octets received by the trunk." ::= { rcCfmPbtTrunkStatsEntry 19 } rcCfmPbtTrunkStatsRxPbit4Frames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of P-Bit 4 Packets received by the trunk." ::= { rcCfmPbtTrunkStatsEntry 20 } rcCfmPbtTrunkStatsRxPbit5Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Pbit 5 Octets received by the trunk." ::= { rcCfmPbtTrunkStatsEntry 21 } rcCfmPbtTrunkStatsRxPbit5Frames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of P-Bit 5 Packets received by the trunk." ::= { rcCfmPbtTrunkStatsEntry 22 } rcCfmPbtTrunkStatsRxPbit6Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Pbit64 Octets received by the trunk." ::= { rcCfmPbtTrunkStatsEntry 23 } rcCfmPbtTrunkStatsRxPbit6Frames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of P-Bit 6 Packets received by the trunk." ::= { rcCfmPbtTrunkStatsEntry 24 } rcCfmPbtTrunkStatsRxPbit7Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Pbit64 Octets received by the trunk." ::= { rcCfmPbtTrunkStatsEntry 25 } rcCfmPbtTrunkStatsRxPbit7Frames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of P-Bit 6 Packets received by the trunk." ::= { rcCfmPbtTrunkStatsEntry 26 } rcCfmPbtTrunkStatsTxPbit0Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Pbit 0 Octets transmitted by the trunk." ::= { rcCfmPbtTrunkStatsEntry 27 } rcCfmPbtTrunkStatsTxPbit0Frames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of P-Bit 0 Packets transmitted by the trunk." ::= { rcCfmPbtTrunkStatsEntry 28 } rcCfmPbtTrunkStatsTxPbit1Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Pbit 1 Octets transmitted by the trunk." ::= { rcCfmPbtTrunkStatsEntry 29 } rcCfmPbtTrunkStatsTxPbit1Frames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of P-Bit 1 Packets transmitted by the trunk." ::= { rcCfmPbtTrunkStatsEntry 30 } rcCfmPbtTrunkStatsTxPbit2Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Pbit 2 Octets transmitted by the trunk." ::= { rcCfmPbtTrunkStatsEntry 31 } rcCfmPbtTrunkStatsTxPbit2Frames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of P-Bit 2 Packets transmitted by the trunk." ::= { rcCfmPbtTrunkStatsEntry 32 } rcCfmPbtTrunkStatsTxPbit3Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Pbit 3 Octets transmitted by the trunk." ::= { rcCfmPbtTrunkStatsEntry 33 } rcCfmPbtTrunkStatsTxPbit3Frames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of P-Bit 3 Packets transmitted by the trunk." ::= { rcCfmPbtTrunkStatsEntry 34 } rcCfmPbtTrunkStatsTxPbit4Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Pbit 4 Octets transmitted by the trunk." ::= { rcCfmPbtTrunkStatsEntry 35 } rcCfmPbtTrunkStatsTxPbit4Frames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of P-Bit 4 Packets transmitted by the trunk." ::= { rcCfmPbtTrunkStatsEntry 36 } rcCfmPbtTrunkStatsTxPbit5Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Pbit 5 Octets transmitted by the trunk." ::= { rcCfmPbtTrunkStatsEntry 37 } rcCfmPbtTrunkStatsTxPbit5Frames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of P-Bit 5 Packets transmitted by the trunk." ::= { rcCfmPbtTrunkStatsEntry 38 } rcCfmPbtTrunkStatsTxPbit6Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Pbit64 Octets transmitted by the trunk." ::= { rcCfmPbtTrunkStatsEntry 39 } rcCfmPbtTrunkStatsTxPbit6Frames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of P-Bit 6 Packets transmitted by the trunk." ::= { rcCfmPbtTrunkStatsEntry 40 } rcCfmPbtTrunkStatsTxPbit7Octets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of Pbit64 Octets transmitted by the trunk." ::= { rcCfmPbtTrunkStatsEntry 41 } rcCfmPbtTrunkStatsTxPbit7Frames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Number of P-Bit 6 Packets transmitted by the trunk." ::= { rcCfmPbtTrunkStatsEntry 42 } -- CFM Port stats table rcCfmPortStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmPortStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Port stats table contains the port Tx and Rx CFM statistics" ::= { rcCfm 20 } rcCfmPortStatsEntry OBJECT-TYPE SYNTAX RcCfmPortStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Port Stats table entry. Contain port's CFM Message sending/receiving counter." INDEX { rcCfmPortStatsIndex } ::= { rcCfmPortStatsTable 1 } RcCfmPortStatsEntry ::= SEQUENCE { rcCfmPortStatsIndex InterfaceIndex, rcCfmPortStatsTxCnt Counter64, rcCfmPortStatsRxCnt Counter64 } rcCfmPortStatsIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "Slot/Port index" ::= { rcCfmPortStatsEntry 1} rcCfmPortStatsTxCnt OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of CFM messages that are sent by port" ::= { rcCfmPortStatsEntry 2 } rcCfmPortStatsRxCnt OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "The total Number of CFM messages are received by port" ::= { rcCfmPortStatsEntry 3 } -- Frame Loss Ratio Profile Table rcCfmFlrTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmFlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Frame Loss Ratio Profile table" ::= { rcCfm 21 } rcCfmFlrEntry OBJECT-TYPE SYNTAX RcCfmFlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Frame Loss Ratio entry." INDEX {rcCfmFlrIndex} ::= { rcCfmFlrTable 1} RcCfmFlrEntry ::= SEQUENCE { rcCfmFlrIndex Integer32, rcCfmFlrProfileName DisplayString, rcCfmFlrRowStatus RowStatus, rcCfmFlrPriority Integer32, rcCfmFlrAlarmThresholdPercent Integer32, rcCfmFlrAlarmThresholdSubPercent Integer32, rcCfmFlrClearThresholdPercent Integer32, rcCfmFlrClearThresholdSubPercent Integer32, rcCfmFlrThresholdState EnableValue, rcCfmFlrNumberOfRefs Gauge32 } rcCfmFlrIndex OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Frame-Loss-Ratio profile index" ::= { rcCfmFlrEntry 1} rcCfmFlrProfileName OBJECT-TYPE SYNTAX DisplayString(SIZE (1..22)) MAX-ACCESS read-create STATUS current DESCRIPTION "Frame-Loss-Ratio Profile Name" ::= { rcCfmFlrEntry 2} rcCfmFlrRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Used to create/delete entries" ::= { rcCfmFlrEntry 3} rcCfmFlrPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-create STATUS current DESCRIPTION "Frame Loss Ratio messaging runs on COS priority" DEFVAL { 7 } ::= { rcCfmFlrEntry 4} rcCfmFlrAlarmThresholdPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-create STATUS current DESCRIPTION "FLR set alarm threshold percentage" DEFVAL { 85 } ::= { rcCfmFlrEntry 5} rcCfmFlrAlarmThresholdSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-create STATUS current DESCRIPTION "FLR set alarm threshold percentage in 1/100 percent increments" DEFVAL { 0 } ::= { rcCfmFlrEntry 6} rcCfmFlrClearThresholdPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-create STATUS current DESCRIPTION "FLR clear alarm threshold percentage" DEFVAL { 0 } ::= { rcCfmFlrEntry 7} rcCfmFlrClearThresholdSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-create STATUS current DESCRIPTION "FLR clear alarm threshold percentage in 1/100 percent increments" DEFVAL { 0 } ::= { rcCfmFlrEntry 8} rcCfmFlrThresholdState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "FLR threshold State" DEFVAL { disable } ::= { rcCfmFlrEntry 9} rcCfmFlrNumberOfRefs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of PMs that reference this flr-profile" DEFVAL { 0 } ::= { rcCfmFlrEntry 10} -- Frame Delay and Frame Delay Variation Profile Table rcCfmFdTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmFdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Frame Delay and Frame Delay Variation Profile table " ::= { rcCfm 22 } rcCfmFdEntry OBJECT-TYPE SYNTAX RcCfmFdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Frame Delay and Frame Delay Variation entry." INDEX {rcCfmFdIndex} ::= { rcCfmFdTable 1} RcCfmFdEntry ::= SEQUENCE { rcCfmFdIndex Integer32, rcCfmFdProfileName DisplayString, rcCfmFdRowStatus RowStatus, rcCfmFdPriority Integer32, rcCfmFdPerformanceTarget Integer32, rcCfmFdAlarmThresholdPercent Integer32, rcCfmFdAlarmThresholdSubPercent Integer32, rcCfmFdClearThresholdPercent Integer32, rcCfmFdClearThresholdSubPercent Integer32, rcCfmFdFdvPerformanceTarget Integer32, rcCfmFdFdvAlarmThresholdPercent Integer32, rcCfmFdFdvAlarmThresholdSubPercent Integer32, rcCfmFdFdvClearThresholdPercent Integer32, rcCfmFdFdvClearThresholdSubPercent Integer32, rcCfmFdThresholdState EnableValue, rcCfmFdNumberOfRefs Gauge32 } rcCfmFdIndex OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Frame-Delay profile index" ::= { rcCfmFdEntry 1} rcCfmFdProfileName OBJECT-TYPE SYNTAX DisplayString(SIZE (1..22)) MAX-ACCESS read-create STATUS current DESCRIPTION "Frame-Delay Profile Name" ::= { rcCfmFdEntry 2} rcCfmFdRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Used to create/delete entries" ::= { rcCfmFdEntry 3} rcCfmFdPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-create STATUS current DESCRIPTION "Frame Delay messaging runs on COS priority" DEFVAL { 7 } ::= { rcCfmFdEntry 4} rcCfmFdPerformanceTarget OBJECT-TYPE SYNTAX Integer32 (1..10000000) MAX-ACCESS read-create STATUS current DESCRIPTION "Frame delay performance objective in microseconds" DEFVAL { 10000000 } ::= { rcCfmFdEntry 5} rcCfmFdAlarmThresholdPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-create STATUS current DESCRIPTION "FD set alarm threshold percentage" DEFVAL { 85 } ::= { rcCfmFdEntry 6} rcCfmFdAlarmThresholdSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-create STATUS current DESCRIPTION "FD set alarm threshold percentage in 1/100 percent incr ements" DEFVAL { 0 } ::= { rcCfmFdEntry 7} rcCfmFdClearThresholdPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-create STATUS current DESCRIPTION "FD clear alarm threshold percentage" DEFVAL { 0 } ::= { rcCfmFdEntry 8} rcCfmFdClearThresholdSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-create STATUS current DESCRIPTION "FD clear alarm threshold percentage in 1/100 percent in crements" DEFVAL { 0 } ::= { rcCfmFdEntry 9} rcCfmFdFdvPerformanceTarget OBJECT-TYPE SYNTAX Integer32 (1..10000000) MAX-ACCESS read-create STATUS current DESCRIPTION "Frame delay variation performance objective in microseconds" DEFVAL { 10000000 } ::= { rcCfmFdEntry 10} rcCfmFdFdvAlarmThresholdPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-create STATUS current DESCRIPTION "FDV set alarm threshold percentage" DEFVAL { 85 } ::= { rcCfmFdEntry 11} rcCfmFdFdvAlarmThresholdSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-create STATUS current DESCRIPTION "FDV set alarm threshold percentage in 1/100 percent inc rements" DEFVAL { 0 } ::= { rcCfmFdEntry 12} rcCfmFdFdvClearThresholdPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-create STATUS current DESCRIPTION "FDV clear alarm threshold percentage" DEFVAL { 0 } ::= { rcCfmFdEntry 13} rcCfmFdFdvClearThresholdSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-create STATUS current DESCRIPTION "FDV clear alarm threshold percentage in 1/100 percent i ncrements" DEFVAL { 0 } ::= { rcCfmFdEntry 14} rcCfmFdThresholdState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "FD / FDV threshold State" DEFVAL { disable } ::= { rcCfmFdEntry 15} rcCfmFdNumberOfRefs OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of PM's that referencen this fd-profile" DEFVAL { 0 } ::= { rcCfmFdEntry 16} -- Frame Loss Ratio Stats Info Table rcCfmFlrStatsInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmFlrStatsInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Frame Loss Ratio Stats Info" ::= { rcCfm 23} rcCfmFlrStatsInfoEntry OBJECT-TYPE SYNTAX RcCfmFlrStatsInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Frame Loss Ratio Stats Info entry." INDEX { rcCfmFlrStatsInfoMdIndex, rcCfmFlrStatsInfoMaIndex, rcCfmFlrStatsInfoMepId, rcCfmFlrStatsInfoRmepId, rcCfmFlrStatsInfoPriorityIndex } ::= { rcCfmFlrStatsInfoTable 1} RcCfmFlrStatsInfoEntry ::= SEQUENCE { rcCfmFlrStatsInfoMdIndex Integer32, rcCfmFlrStatsInfoMaIndex Integer32, rcCfmFlrStatsInfoMepId Integer32, rcCfmFlrStatsInfoRmepId Integer32, rcCfmFlrStatsInfoPriorityIndex Integer32, rcCfmFlrStatsInfoMdName DisplayString, rcCfmFlrStatsInfoMaName DisplayString, rcCfmFlrStatsInfoPriority Integer32, rcCfmFlrStatsInfoNearEndPercent Integer32, rcCfmFlrStatsInfoNearEndSubPercent Integer32, rcCfmFlrStatsInfoFarEndPercent Integer32, rcCfmFlrStatsInfoFarEndSubPercent Integer32, rcCfmFlrStatsInfoPmOperState RcCfmPmOperState } rcCfmFlrStatsInfoMdIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmFlrStatsInfoEntry 1} rcCfmFlrStatsInfoMaIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmFlrStatsInfoEntry 2} rcCfmFlrStatsInfoMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance EndPoint ID" ::= { rcCfmFlrStatsInfoEntry 3} rcCfmFlrStatsInfoRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Peer Identifier which matches a RemoteMepId. The performance monitoring pair is MepId-RmepId" ::= { rcCfmFlrStatsInfoEntry 4} rcCfmFlrStatsInfoPriorityIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "priorityIndex equals priority plus 1 - priority can't be used as an index since it starts from 0" ::= { rcCfmFlrStatsInfoEntry 5} rcCfmFlrStatsInfoMdName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmFlrStatsInfoEntry 6} rcCfmFlrStatsInfoMaName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmFlrStatsInfoEntry 7} rcCfmFlrStatsInfoPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Frame Loss Ratio messaging runs on COS priority" DEFVAL { 7 } ::= { rcCfmFlrStatsInfoEntry 8} rcCfmFlrStatsInfoNearEndPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR percentage" ::= { rcCfmFlrStatsInfoEntry 9} rcCfmFlrStatsInfoNearEndSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR sub percentage" ::= { rcCfmFlrStatsInfoEntry 10} rcCfmFlrStatsInfoFarEndPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured far-end FLR percentage" ::= { rcCfmFlrStatsInfoEntry 11} rcCfmFlrStatsInfoFarEndSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured far-end FLR sub percentage" ::= { rcCfmFlrStatsInfoEntry 12} rcCfmFlrStatsInfoPmOperState OBJECT-TYPE SYNTAX RcCfmPmOperState MAX-ACCESS read-only STATUS current DESCRIPTION "The operational state of the PM." ::= {rcCfmFlrStatsInfoEntry 13} -- Frame Loss Ratio Stats Current Table rcCfmFlrStatsCurrTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmFlrStatsCurrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Frame Loss Ratio Stats Current" ::= { rcCfm 24} rcCfmFlrStatsCurrEntry OBJECT-TYPE SYNTAX RcCfmFlrStatsCurrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Frame Loss Ratio Stats Current entry." INDEX { rcCfmFlrStatsCurrMdIndex, rcCfmFlrStatsCurrMaIndex, rcCfmFlrStatsCurrMepId, rcCfmFlrStatsCurrRmepId, rcCfmFlrStatsCurrPriorityIndex } ::= { rcCfmFlrStatsCurrTable 1} RcCfmFlrStatsCurrEntry ::= SEQUENCE { rcCfmFlrStatsCurrMdIndex Integer32, rcCfmFlrStatsCurrMaIndex Integer32, rcCfmFlrStatsCurrMepId Integer32, rcCfmFlrStatsCurrRmepId Integer32, rcCfmFlrStatsCurrPriorityIndex Integer32, rcCfmFlrStatsCurrMdName DisplayString, rcCfmFlrStatsCurrMaName DisplayString, rcCfmFlrStatsCurrPriority Integer32, rcCfmFlrStatsCurrPmOperState RcCfmPmOperState, rcCfmFlrStatsCurrStartTime OCTET STRING , rcCfmFlrStatsCurrEndTime OCTET STRING , rcCfmFlrStatsCurrHistInterval Gauge32, rcCfmFlrStatsCurrSampleRate Gauge32, rcCfmFlrStatsCurrNearEndPercent Integer32, rcCfmFlrStatsCurrNearEndSubPercent Integer32, rcCfmFlrStatsCurrFarEndPercent Integer32, rcCfmFlrStatsCurrFarEndSubPercent Integer32, rcCfmFlrStatsCurrMinNearEndPercent Integer32, rcCfmFlrStatsCurrMinNearEndSubPercent Integer32, rcCfmFlrStatsCurrMinFarEndPercent Integer32, rcCfmFlrStatsCurrMinFarEndSubPercent Integer32, rcCfmFlrStatsCurrMaxNearEndPercent Integer32, rcCfmFlrStatsCurrMaxNearEndSubPercent Integer32, rcCfmFlrStatsCurrMaxFarEndPercent Integer32, rcCfmFlrStatsCurrMaxFarEndSubPercent Integer32, rcCfmFlrStatsCurrTxFrames Counter64, rcCfmFlrStatsCurrRxFrames Counter64, rcCfmFlrStatsCurrFlFrames Counter64, rcCfmFlrStatsCurrTxFarEndFrames Counter64, rcCfmFlrStatsCurrRxFarEndFrames Counter64, rcCfmFlrStatsCurrFlFarEndFrames Counter64, rcCfmFlrStatsCurrSamplesPerInterval Gauge32, rcCfmFlrStatsCurrSamplesTransmitted Gauge32, rcCfmFlrStatsCurrMinFlFrames Counter32, rcCfmFlrStatsCurrSamplesNotSent Gauge32, rcCfmFlrStatsCurrSamplesReceived Gauge32, rcCfmFlrStatsCurrMinFlFarEndFrames Counter32, rcCfmFlrStatsCurrMaxFlFrames Counter32, rcCfmFlrStatsCurrMaxFlFarEndFrames Counter32 } rcCfmFlrStatsCurrMdIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmFlrStatsCurrEntry 1} rcCfmFlrStatsCurrMaIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmFlrStatsCurrEntry 2} rcCfmFlrStatsCurrMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance EndPoint ID" ::= { rcCfmFlrStatsCurrEntry 3} rcCfmFlrStatsCurrRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Peer Identifier which matches a RemoteMepId. The performance monitoring pair is MepId-RmepId" ::= { rcCfmFlrStatsCurrEntry 4} rcCfmFlrStatsCurrPriorityIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "priorityIndex equals priority plus 1 - priority can't be used as an index since it starts from 0" ::= { rcCfmFlrStatsCurrEntry 5} rcCfmFlrStatsCurrMdName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmFlrStatsCurrEntry 6} rcCfmFlrStatsCurrMaName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmFlrStatsCurrEntry 7} rcCfmFlrStatsCurrPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Frame Loss Ratio messaging runs on COS priority" DEFVAL { 7 } ::= { rcCfmFlrStatsCurrEntry 8} rcCfmFlrStatsCurrPmOperState OBJECT-TYPE SYNTAX RcCfmPmOperState MAX-ACCESS read-only STATUS current DESCRIPTION "The operational state of the PM." ::= {rcCfmFlrStatsCurrEntry 9} rcCfmFlrStatsCurrStartTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE(11)) MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time stamp." ::= { rcCfmFlrStatsCurrEntry 10} rcCfmFlrStatsCurrEndTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE(11)) MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time stamp." ::= { rcCfmFlrStatsCurrEntry 11} rcCfmFlrStatsCurrHistInterval OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "History Interval" ::= { rcCfmFlrStatsCurrEntry 12} rcCfmFlrStatsCurrSampleRate OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Sample rate in seconds" ::= { rcCfmFlrStatsCurrEntry 13} rcCfmFlrStatsCurrNearEndPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR percentage" ::= { rcCfmFlrStatsCurrEntry 14} rcCfmFlrStatsCurrNearEndSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR sub percentage" ::= { rcCfmFlrStatsCurrEntry 15} rcCfmFlrStatsCurrFarEndPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured far-end FLR percentage" ::= { rcCfmFlrStatsCurrEntry 16} rcCfmFlrStatsCurrFarEndSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured far-end FLR sub percentage" ::= { rcCfmFlrStatsCurrEntry 17} rcCfmFlrStatsCurrMinNearEndPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR percentage" ::= { rcCfmFlrStatsCurrEntry 18} rcCfmFlrStatsCurrMinNearEndSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR sub percentage" ::= { rcCfmFlrStatsCurrEntry 19} rcCfmFlrStatsCurrMinFarEndPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR percentage" ::= { rcCfmFlrStatsCurrEntry 20} rcCfmFlrStatsCurrMinFarEndSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR sub percentage" ::= { rcCfmFlrStatsCurrEntry 21} rcCfmFlrStatsCurrMaxNearEndPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR percentage" ::= { rcCfmFlrStatsCurrEntry 22} rcCfmFlrStatsCurrMaxNearEndSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR sub percentage" ::= { rcCfmFlrStatsCurrEntry 23} rcCfmFlrStatsCurrMaxFarEndPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR percentage" ::= { rcCfmFlrStatsCurrEntry 24} rcCfmFlrStatsCurrMaxFarEndSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR sub percentage" ::= { rcCfmFlrStatsCurrEntry 25} rcCfmFlrStatsCurrTxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Tx frames" ::= { rcCfmFlrStatsCurrEntry 26} rcCfmFlrStatsCurrRxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Rx frames" ::= { rcCfmFlrStatsCurrEntry 27} rcCfmFlrStatsCurrFlFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Frame Loss frames" ::= { rcCfmFlrStatsCurrEntry 28} rcCfmFlrStatsCurrTxFarEndFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end Tx frames" ::= { rcCfmFlrStatsCurrEntry 29} rcCfmFlrStatsCurrRxFarEndFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end Rx frames" ::= { rcCfmFlrStatsCurrEntry 30} rcCfmFlrStatsCurrFlFarEndFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end Frame Loss frames" ::= { rcCfmFlrStatsCurrEntry 31} rcCfmFlrStatsCurrSamplesPerInterval OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Samples per interval" ::= { rcCfmFlrStatsCurrEntry 32} rcCfmFlrStatsCurrSamplesTransmitted OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Samples transmitted" ::= { rcCfmFlrStatsCurrEntry 33} rcCfmFlrStatsCurrMinFlFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum sample Frame Loss frames" ::= { rcCfmFlrStatsCurrEntry 34} rcCfmFlrStatsCurrSamplesNotSent OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Samples not sent" ::= { rcCfmFlrStatsCurrEntry 35} rcCfmFlrStatsCurrSamplesReceived OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Samples received" ::= { rcCfmFlrStatsCurrEntry 36} rcCfmFlrStatsCurrMinFlFarEndFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum sample Far-end Frame Loss frames" ::= { rcCfmFlrStatsCurrEntry 37} rcCfmFlrStatsCurrMaxFlFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum sample Frame Loss frames" ::= { rcCfmFlrStatsCurrEntry 38} rcCfmFlrStatsCurrMaxFlFarEndFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum sample Far-end Frame Loss frames" ::= { rcCfmFlrStatsCurrEntry 39} -- Frame Loss Ratio Stats History Table rcCfmFlrStatsHistTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmFlrStatsHistEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Frame Loss Ratio Stats History" ::= { rcCfm 25} rcCfmFlrStatsHistEntry OBJECT-TYPE SYNTAX RcCfmFlrStatsHistEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Frame Loss Ratio Stats History entry." INDEX { rcCfmFlrStatsHistMdIndex, rcCfmFlrStatsHistMaIndex, rcCfmFlrStatsHistMepId, rcCfmFlrStatsHistRmepId, rcCfmFlrStatsHistPriorityIndex, rcCfmFlrStatsHistIndex } ::= { rcCfmFlrStatsHistTable 1} RcCfmFlrStatsHistEntry ::= SEQUENCE { rcCfmFlrStatsHistMdIndex Integer32, rcCfmFlrStatsHistMaIndex Integer32, rcCfmFlrStatsHistMepId Integer32, rcCfmFlrStatsHistRmepId Integer32, rcCfmFlrStatsHistPriorityIndex Integer32, rcCfmFlrStatsHistIndex Integer32, rcCfmFlrStatsHistMdName DisplayString, rcCfmFlrStatsHistMaName DisplayString, rcCfmFlrStatsHistPriority Integer32, rcCfmFlrStatsHistStatus INTEGER, rcCfmFlrStatsHistStartTime OCTET STRING , rcCfmFlrStatsHistEndTime OCTET STRING , rcCfmFlrStatsHistHistInterval Gauge32, rcCfmFlrStatsHistSampleRate Gauge32, rcCfmFlrStatsHistNearEndPercent Integer32, rcCfmFlrStatsHistNearEndSubPercent Integer32, rcCfmFlrStatsHistFarEndPercent Integer32, rcCfmFlrStatsHistFarEndSubPercent Integer32, rcCfmFlrStatsHistMinNearEndPercent Integer32, rcCfmFlrStatsHistMinNearEndSubPercent Integer32, rcCfmFlrStatsHistMinFarEndPercent Integer32, rcCfmFlrStatsHistMinFarEndSubPercent Integer32, rcCfmFlrStatsHistMaxNearEndPercent Integer32, rcCfmFlrStatsHistMaxNearEndSubPercent Integer32, rcCfmFlrStatsHistMaxFarEndPercent Integer32, rcCfmFlrStatsHistMaxFarEndSubPercent Integer32, rcCfmFlrStatsHistTxFrames Counter64, rcCfmFlrStatsHistRxFrames Counter64, rcCfmFlrStatsHistFlFrames Counter64, rcCfmFlrStatsHistTxFarEndFrames Counter64, rcCfmFlrStatsHistRxFarEndFrames Counter64, rcCfmFlrStatsHistFlFarEndFrames Counter64, rcCfmFlrStatsHistSamplesPerInterval Gauge32, rcCfmFlrStatsHistSamplesTransmitted Gauge32, rcCfmFlrStatsHistMinFlFrames Counter32, rcCfmFlrStatsHistSamplesNotSent Gauge32, rcCfmFlrStatsHistSamplesReceived Gauge32, rcCfmFlrStatsHistMinFlFarEndFrames Counter32, rcCfmFlrStatsHistMaxFlFrames Counter32, rcCfmFlrStatsHistMaxFlFarEndFrames Counter32 } rcCfmFlrStatsHistMdIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmFlrStatsHistEntry 1} rcCfmFlrStatsHistMaIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmFlrStatsHistEntry 2} rcCfmFlrStatsHistMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance EndPoint ID" ::= { rcCfmFlrStatsHistEntry 3} rcCfmFlrStatsHistRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Peer Identifier which matches a RemoteMepId. The performance monitoring pair is MepId-RmepId" ::= { rcCfmFlrStatsHistEntry 4} rcCfmFlrStatsHistPriorityIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "priorityIndex equals priority plus 1 - priority can't be used as an index since it starts from 0" ::= { rcCfmFlrStatsHistEntry 5} rcCfmFlrStatsHistIndex OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS not-accessible STATUS current DESCRIPTION "History Index" ::= { rcCfmFlrStatsHistEntry 6} rcCfmFlrStatsHistMdName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmFlrStatsHistEntry 7} rcCfmFlrStatsHistMaName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmFlrStatsHistEntry 8} rcCfmFlrStatsHistPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Frame Loss Ratio messaging runs on COS priority" DEFVAL { 7 } ::= { rcCfmFlrStatsHistEntry 9} rcCfmFlrStatsHistStatus OBJECT-TYPE SYNTAX INTEGER { complete(1), incomplete(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of this history interval." ::= {rcCfmFlrStatsHistEntry 10} rcCfmFlrStatsHistStartTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE(11)) MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time stamp." ::= { rcCfmFlrStatsHistEntry 11} rcCfmFlrStatsHistEndTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE(11)) MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time stamp." ::= { rcCfmFlrStatsHistEntry 12} rcCfmFlrStatsHistHistInterval OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "History Interval" ::= { rcCfmFlrStatsHistEntry 13} rcCfmFlrStatsHistSampleRate OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Sample rate in seconds" ::= { rcCfmFlrStatsHistEntry 14} rcCfmFlrStatsHistNearEndPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR percentage" ::= { rcCfmFlrStatsHistEntry 15} rcCfmFlrStatsHistNearEndSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR sub percentage" ::= { rcCfmFlrStatsHistEntry 16} rcCfmFlrStatsHistFarEndPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured far-end FLR percentage" ::= { rcCfmFlrStatsHistEntry 17} rcCfmFlrStatsHistFarEndSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured far-end FLR sub percentage" ::= { rcCfmFlrStatsHistEntry 18} rcCfmFlrStatsHistMinNearEndPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR percentage" ::= { rcCfmFlrStatsHistEntry 19} rcCfmFlrStatsHistMinNearEndSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR sub percentage" ::= { rcCfmFlrStatsHistEntry 20} rcCfmFlrStatsHistMinFarEndPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR percentage" ::= { rcCfmFlrStatsHistEntry 21} rcCfmFlrStatsHistMinFarEndSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR sub percentage" ::= { rcCfmFlrStatsHistEntry 22} rcCfmFlrStatsHistMaxNearEndPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR percentage" ::= { rcCfmFlrStatsHistEntry 23} rcCfmFlrStatsHistMaxNearEndSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR sub percentage" ::= { rcCfmFlrStatsHistEntry 24} rcCfmFlrStatsHistMaxFarEndPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR percentage" ::= { rcCfmFlrStatsHistEntry 25} rcCfmFlrStatsHistMaxFarEndSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured near-end FLR sub percentage" ::= { rcCfmFlrStatsHistEntry 26} rcCfmFlrStatsHistTxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Tx frames" ::= { rcCfmFlrStatsHistEntry 27} rcCfmFlrStatsHistRxFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Rx frames" ::= { rcCfmFlrStatsHistEntry 28} rcCfmFlrStatsHistFlFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Frame Loss frames" ::= { rcCfmFlrStatsHistEntry 29} rcCfmFlrStatsHistTxFarEndFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end Tx frames" ::= { rcCfmFlrStatsHistEntry 30} rcCfmFlrStatsHistRxFarEndFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end Rx frames" ::= { rcCfmFlrStatsHistEntry 31} rcCfmFlrStatsHistFlFarEndFrames OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end Frame Loss frames" ::= { rcCfmFlrStatsHistEntry 32} rcCfmFlrStatsHistSamplesPerInterval OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Samples per interval" ::= { rcCfmFlrStatsHistEntry 33} rcCfmFlrStatsHistSamplesTransmitted OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Samples transmitted" ::= { rcCfmFlrStatsHistEntry 34} rcCfmFlrStatsHistMinFlFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum sample Frame Loss frames" ::= { rcCfmFlrStatsHistEntry 35} rcCfmFlrStatsHistSamplesNotSent OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Samples not sent" ::= { rcCfmFlrStatsHistEntry 36} rcCfmFlrStatsHistSamplesReceived OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Samples received" ::= { rcCfmFlrStatsHistEntry 37} rcCfmFlrStatsHistMinFlFarEndFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum sample Far-end Frame Loss frames" ::= { rcCfmFlrStatsHistEntry 38} rcCfmFlrStatsHistMaxFlFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum sample Frame Loss frames" ::= { rcCfmFlrStatsHistEntry 39} rcCfmFlrStatsHistMaxFlFarEndFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum sample Far-end Frame Loss frames" ::= { rcCfmFlrStatsHistEntry 40} -- Frame Delay Stats Info Table rcCfmFdStatsInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmFdStatsInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Frame Delay Stats Info" ::= { rcCfm 26} rcCfmFdStatsInfoEntry OBJECT-TYPE SYNTAX RcCfmFdStatsInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Frame Delay Stats Info entry." INDEX { rcCfmFdStatsInfoMdIndex, rcCfmFdStatsInfoMaIndex, rcCfmFdStatsInfoMepId, rcCfmFdStatsInfoRmepId, rcCfmFdStatsInfoPriorityIndex } ::= { rcCfmFdStatsInfoTable 1} RcCfmFdStatsInfoEntry ::= SEQUENCE { rcCfmFdStatsInfoMdIndex Integer32, rcCfmFdStatsInfoMaIndex Integer32, rcCfmFdStatsInfoMepId Integer32, rcCfmFdStatsInfoRmepId Integer32, rcCfmFdStatsInfoPriorityIndex Integer32, rcCfmFdStatsInfoMdName DisplayString, rcCfmFdStatsInfoMaName DisplayString, rcCfmFdStatsInfoPriority Integer32, rcCfmFdStatsInfoFdPercent Integer32, rcCfmFdStatsInfoFdSubPercent Integer32, rcCfmFdStatsInfoFdvPercent Integer32, rcCfmFdStatsInfoFdvSubPercent Integer32, rcCfmFdStatsInfoPmOperState RcCfmPmOperState } rcCfmFdStatsInfoMdIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmFdStatsInfoEntry 1} rcCfmFdStatsInfoMaIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmFdStatsInfoEntry 2} rcCfmFdStatsInfoMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance EndPoint ID" ::= { rcCfmFdStatsInfoEntry 3} rcCfmFdStatsInfoRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Peer Identifier which matches a RemoteMepId. The performance monitoring pair is MepId-RmepId" ::= { rcCfmFdStatsInfoEntry 4} rcCfmFdStatsInfoPriorityIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "priorityIndex equals priority plus 1 - priority can't be used as an index since it starts from 0" ::= { rcCfmFdStatsInfoEntry 5} rcCfmFdStatsInfoMdName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmFdStatsInfoEntry 6} rcCfmFdStatsInfoMaName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmFdStatsInfoEntry 7} rcCfmFdStatsInfoPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Frame Delay messaging runs on COS priority" DEFVAL { 7 } ::= { rcCfmFdStatsInfoEntry 8} rcCfmFdStatsInfoFdPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured FD percentage" ::= { rcCfmFdStatsInfoEntry 9} rcCfmFdStatsInfoFdSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured FD sub percentage" ::= { rcCfmFdStatsInfoEntry 10} rcCfmFdStatsInfoFdvPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured FDV percentage" ::= { rcCfmFdStatsInfoEntry 11} rcCfmFdStatsInfoFdvSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured FDV sub percentage" ::= { rcCfmFdStatsInfoEntry 12} rcCfmFdStatsInfoPmOperState OBJECT-TYPE SYNTAX RcCfmPmOperState MAX-ACCESS read-only STATUS current DESCRIPTION "The operational state of the PM." ::= {rcCfmFdStatsInfoEntry 13} -- Frame Delay Stats Current Table rcCfmFdStatsCurrTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmFdStatsCurrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Frame Delay Stats Current" ::= { rcCfm 27} rcCfmFdStatsCurrEntry OBJECT-TYPE SYNTAX RcCfmFdStatsCurrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Frame Delay Stats Current entry." INDEX { rcCfmFdStatsCurrMdIndex, rcCfmFdStatsCurrMaIndex, rcCfmFdStatsCurrMepId, rcCfmFdStatsCurrRmepId, rcCfmFdStatsCurrPriorityIndex } ::= { rcCfmFdStatsCurrTable 1} RcCfmFdStatsCurrEntry ::= SEQUENCE { rcCfmFdStatsCurrMdIndex Integer32, rcCfmFdStatsCurrMaIndex Integer32, rcCfmFdStatsCurrMepId Integer32, rcCfmFdStatsCurrRmepId Integer32, rcCfmFdStatsCurrPriorityIndex Integer32, rcCfmFdStatsCurrMdName DisplayString, rcCfmFdStatsCurrMaName DisplayString, rcCfmFdStatsCurrPriority Integer32, rcCfmFdStatsCurrFdPercent Integer32, rcCfmFdStatsCurrFdSubPercent Integer32, rcCfmFdStatsCurrFdvPercent Integer32, rcCfmFdStatsCurrFdvSubPercent Integer32, rcCfmFdStatsCurrPmOperState RcCfmPmOperState, rcCfmFdStatsCurrStartTime OCTET STRING , rcCfmFdStatsCurrEndTime OCTET STRING , rcCfmFdStatsCurrHistInterval Gauge32, rcCfmFdStatsCurrSampleRate Gauge32, rcCfmFdStatsCurrTarget Counter32, rcCfmFdStatsCurrAverage Counter32, rcCfmFdStatsCurrMinimum Counter32, rcCfmFdStatsCurrMaximum Counter32, rcCfmFdStatsCurrFdvTarget Counter32, rcCfmFdStatsCurrFdvAverage Counter32, rcCfmFdStatsCurrFdvMinimum Counter32, rcCfmFdStatsCurrFdvMaximum Counter32, rcCfmFdStatsCurrSamplesPerInterval Gauge32, rcCfmFdStatsCurrSamplesTransmitted Gauge32, rcCfmFdStatsCurrSamplesNotSent Gauge32, rcCfmFdStatsCurrSamplesReceived Gauge32 } rcCfmFdStatsCurrMdIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmFdStatsCurrEntry 1} rcCfmFdStatsCurrMaIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmFdStatsCurrEntry 2} rcCfmFdStatsCurrMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance EndPoint ID" ::= { rcCfmFdStatsCurrEntry 3} rcCfmFdStatsCurrRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Peer Identifier which matches a RemoteMepId. The performance monitoring pair is MepId-RmepId" ::= { rcCfmFdStatsCurrEntry 4} rcCfmFdStatsCurrPriorityIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "priorityIndex equals priority plus 1 - priority can't be used as an index since it starts from 0" ::= { rcCfmFdStatsCurrEntry 5} rcCfmFdStatsCurrMdName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmFdStatsCurrEntry 6} rcCfmFdStatsCurrMaName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmFdStatsCurrEntry 7} rcCfmFdStatsCurrPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Frame Delay messaaging runs on COS priority" DEFVAL { 7 } ::= { rcCfmFdStatsCurrEntry 8} rcCfmFdStatsCurrFdPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured FD percentage" ::= { rcCfmFdStatsCurrEntry 9} rcCfmFdStatsCurrFdSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured FD sub percentage" ::= { rcCfmFdStatsCurrEntry 10} rcCfmFdStatsCurrFdvPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured FDV percentage" ::= { rcCfmFdStatsCurrEntry 11} rcCfmFdStatsCurrFdvSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured FDV sub percentage" ::= { rcCfmFdStatsCurrEntry 12} rcCfmFdStatsCurrPmOperState OBJECT-TYPE SYNTAX RcCfmPmOperState MAX-ACCESS read-only STATUS current DESCRIPTION "The operational state of the PM." ::= {rcCfmFdStatsCurrEntry 13} rcCfmFdStatsCurrStartTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE(11)) MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time stamp." ::= { rcCfmFdStatsCurrEntry 14} rcCfmFdStatsCurrEndTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE(11)) MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time stamp." ::= { rcCfmFdStatsCurrEntry 15} rcCfmFdStatsCurrHistInterval OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "History Interval" ::= { rcCfmFdStatsCurrEntry 16} rcCfmFdStatsCurrSampleRate OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Sample rate in seconds" ::= { rcCfmFdStatsCurrEntry 17} rcCfmFdStatsCurrTarget OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FD target in microseconds" ::= { rcCfmFdStatsCurrEntry 18} rcCfmFdStatsCurrAverage OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FD average in microseconds" ::= { rcCfmFdStatsCurrEntry 19} rcCfmFdStatsCurrMinimum OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FD minimum in microseconds" ::= { rcCfmFdStatsCurrEntry 20} rcCfmFdStatsCurrMaximum OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FD maximum in microseconds" ::= { rcCfmFdStatsCurrEntry 21} rcCfmFdStatsCurrFdvTarget OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FDV target in microseconds" ::= { rcCfmFdStatsCurrEntry 22} rcCfmFdStatsCurrFdvAverage OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FDV average in microseconds" ::= { rcCfmFdStatsCurrEntry 23} rcCfmFdStatsCurrFdvMinimum OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FDV minimum in microseconds" ::= { rcCfmFdStatsCurrEntry 24} rcCfmFdStatsCurrFdvMaximum OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FDV maximum in microseconds" ::= { rcCfmFdStatsCurrEntry 25} rcCfmFdStatsCurrSamplesPerInterval OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Samples per interval" ::= { rcCfmFdStatsCurrEntry 26} rcCfmFdStatsCurrSamplesTransmitted OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Samples transmitted" ::= { rcCfmFdStatsCurrEntry 27} rcCfmFdStatsCurrSamplesNotSent OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Samples not sent" ::= { rcCfmFdStatsCurrEntry 28} rcCfmFdStatsCurrSamplesReceived OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Samples received" ::= { rcCfmFdStatsCurrEntry 29} -- Frame Delay Stats History Table rcCfmFdStatsHistTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmFdStatsHistEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Frame Delay Stats History" ::= { rcCfm 28} rcCfmFdStatsHistEntry OBJECT-TYPE SYNTAX RcCfmFdStatsHistEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Frame Delay Stats History entry." INDEX { rcCfmFdStatsHistMdIndex, rcCfmFdStatsHistMaIndex, rcCfmFdStatsHistMepId, rcCfmFdStatsHistRmepId, rcCfmFdStatsHistPriorityIndex} ::= { rcCfmFdStatsHistTable 1} RcCfmFdStatsHistEntry ::= SEQUENCE { rcCfmFdStatsHistMdIndex Integer32, rcCfmFdStatsHistMaIndex Integer32, rcCfmFdStatsHistMepId Integer32, rcCfmFdStatsHistRmepId Integer32, rcCfmFdStatsHistPriorityIndex Integer32, rcCfmFdStatsHistIndex Integer32, rcCfmFdStatsHistMdName DisplayString, rcCfmFdStatsHistMaName DisplayString, rcCfmFdStatsHistPriority Integer32, rcCfmFdStatsHistFdPercent Integer32, rcCfmFdStatsHistFdSubPercent Integer32, rcCfmFdStatsHistFdvPercent Integer32, rcCfmFdStatsHistFdvSubPercent Integer32, rcCfmFdStatsHistStatus INTEGER, rcCfmFdStatsHistStartTime OCTET STRING , rcCfmFdStatsHistEndTime OCTET STRING , rcCfmFdStatsHistHistInterval Gauge32, rcCfmFdStatsHistSampleRate Gauge32, rcCfmFdStatsHistTarget Counter32, rcCfmFdStatsHistAverage Counter32, rcCfmFdStatsHistMinimum Counter32, rcCfmFdStatsHistMaximum Counter32, rcCfmFdStatsHistFdvTarget Counter32, rcCfmFdStatsHistFdvAverage Counter32, rcCfmFdStatsHistFdvMinimum Counter32, rcCfmFdStatsHistFdvMaximum Counter32, rcCfmFdStatsHistSamplesPerInterval Gauge32, rcCfmFdStatsHistSamplesTransmitted Gauge32, rcCfmFdStatsHistSamplesNotSent Gauge32, rcCfmFdStatsHistSamplesReceived Gauge32 } rcCfmFdStatsHistMdIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmFdStatsHistEntry 1} rcCfmFdStatsHistMaIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmFdStatsHistEntry 2} rcCfmFdStatsHistMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance EndPoint ID" ::= { rcCfmFdStatsHistEntry 3} rcCfmFdStatsHistRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Peer Identifier which matches a RemoteMepId. The performance monitoring pair is MepId-RmepId" ::= { rcCfmFdStatsHistEntry 4} rcCfmFdStatsHistPriorityIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "priorityIndex equals priority plus 1 - priority can't be used as an index since it starts from 0" ::= { rcCfmFdStatsHistEntry 5} rcCfmFdStatsHistIndex OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS not-accessible STATUS current DESCRIPTION "History Index" ::= { rcCfmFdStatsHistEntry 6} rcCfmFdStatsHistMdName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmFdStatsHistEntry 7} rcCfmFdStatsHistMaName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmFdStatsHistEntry 8} rcCfmFdStatsHistPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Frame Delay messaging runs on COS priority" DEFVAL { 7 } ::= { rcCfmFdStatsHistEntry 9} rcCfmFdStatsHistFdPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured FD percentage" ::= { rcCfmFdStatsHistEntry 10} rcCfmFdStatsHistFdSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured FD sub percentage" ::= { rcCfmFdStatsHistEntry 11} rcCfmFdStatsHistFdvPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured FDV percentage" ::= { rcCfmFdStatsHistEntry 12} rcCfmFdStatsHistFdvSubPercent OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Measured FDV sub percentage" ::= { rcCfmFdStatsHistEntry 13} rcCfmFdStatsHistStatus OBJECT-TYPE SYNTAX INTEGER { complete(1), incomplete(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of this history interval." ::= {rcCfmFdStatsHistEntry 14} rcCfmFdStatsHistStartTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE(11)) MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time stamp." ::= { rcCfmFdStatsHistEntry 15} rcCfmFdStatsHistEndTime OBJECT-TYPE SYNTAX OCTET STRING (SIZE(11)) MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time stamp." ::= { rcCfmFdStatsHistEntry 16} rcCfmFdStatsHistHistInterval OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "History Interval" ::= { rcCfmFdStatsHistEntry 17} rcCfmFdStatsHistSampleRate OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Sample rate in seconds" ::= { rcCfmFdStatsHistEntry 18} rcCfmFdStatsHistTarget OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FD target in microseconds" ::= { rcCfmFdStatsHistEntry 19} rcCfmFdStatsHistAverage OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FD average in microseconds" ::= { rcCfmFdStatsHistEntry 20} rcCfmFdStatsHistMinimum OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FD minimum in microseconds" ::= { rcCfmFdStatsHistEntry 21} rcCfmFdStatsHistMaximum OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FD maximum in microseconds" ::= { rcCfmFdStatsHistEntry 22} rcCfmFdStatsHistFdvTarget OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FDV target in microseconds" ::= { rcCfmFdStatsHistEntry 23} rcCfmFdStatsHistFdvAverage OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FDV average in microseconds" ::= { rcCfmFdStatsHistEntry 24} rcCfmFdStatsHistFdvMinimum OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FDV minimum in microseconds" ::= { rcCfmFdStatsHistEntry 25} rcCfmFdStatsHistFdvMaximum OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "FDV maximum in microseconds" ::= { rcCfmFdStatsHistEntry 26} rcCfmFdStatsHistSamplesPerInterval OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Samples per interval" ::= { rcCfmFdStatsHistEntry 27} rcCfmFdStatsHistSamplesTransmitted OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Samples transmitted" ::= { rcCfmFdStatsHistEntry 28} rcCfmFdStatsHistSamplesNotSent OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Samples not sent" ::= { rcCfmFdStatsHistEntry 29} rcCfmFdStatsHistSamplesReceived OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Samples received" ::= { rcCfmFdStatsHistEntry 30} -- Performance Monitoring Configuration Table rcCfmPmTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmPmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CFM Performance Monitoring Configuration" ::= { rcCfm 29} rcCfmPmEntry OBJECT-TYPE SYNTAX RcCfmPmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connectivity Fault Management Performance Monitoring entry." INDEX {rcCfmPmMdIndex, rcCfmPmMaIndex, rcCfmPmMepId, rcCfmPmRmepId } ::= { rcCfmPmTable 1} RcCfmPmEntry ::= SEQUENCE { rcCfmPmMdIndex Integer32, rcCfmPmMaIndex Integer32, rcCfmPmMepId Integer32, rcCfmPmRmepId Integer32, rcCfmPmMdName DisplayString, rcCfmPmMaName DisplayString, rcCfmPmRowStatus RowStatus, rcCfmPmState EnableValue, rcCfmPmFdList DisplayString, rcCfmPmFdSize Integer32, rcCfmPmFlrList DisplayString, rcCfmPmFlrSize Integer32, rcCfmPmHistoryInterval INTEGER, rcCfmPmSampleRate INTEGER } rcCfmPmMdIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmPmEntry 1} rcCfmPmMaIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmPmEntry 2} rcCfmPmMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance EndPoint ID" ::= { rcCfmPmEntry 3} rcCfmPmRmepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Remote Maintenance Endpoint ID. The performance monitoring pair is MepId-RmepId" ::= { rcCfmPmEntry 4} rcCfmPmMdName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmPmEntry 5} rcCfmPmMaName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmPmEntry 6} rcCfmPmRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Used to create/delete entries" ::= { rcCfmPmEntry 7 } rcCfmPmState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Performance Monitoring State" DEFVAL { disable } ::= { rcCfmPmEntry 8 } rcCfmPmFdList OBJECT-TYPE SYNTAX DisplayString (SIZE(0..200)) MAX-ACCESS read-create STATUS current DESCRIPTION "Comma separated list of Frame-Delay profile names. Valid profile names must first be created using rcCfmFdProfileName. Number of entries in the list is indicated by rcCfmPmFdSize." ::= { rcCfmPmEntry 9 } rcCfmPmFdSize OBJECT-TYPE SYNTAX Integer32 (0..8) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Frame-Delay profiles names" ::= { rcCfmPmEntry 10 } rcCfmPmFlrList OBJECT-TYPE SYNTAX DisplayString (SIZE(0..200)) MAX-ACCESS read-create STATUS current DESCRIPTION "Comma separated list of Frame-Loss-Ratio profile names. Valid profile names must first be created using rcCfmFlrProfileName. Number of entries in the list is indicated by rcCfmPmFlrSize." ::= { rcCfmPmEntry 11 } rcCfmPmFlrSize OBJECT-TYPE SYNTAX Integer32 (0..8) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of FLR profile names in FLR list" ::= { rcCfmPmEntry 12 } rcCfmPmHistoryInterval OBJECT-TYPE SYNTAX INTEGER { hi5(5), hi15(15), hi30(30), hi60(60), hi120(120), hi360(360), hi720(720), hi1440(1440) } UNITS "minutes" MAX-ACCESS read-create STATUS current DESCRIPTION "History summary interval in minutes" DEFVAL { hi15 } ::= { rcCfmPmEntry 13} rcCfmPmSampleRate OBJECT-TYPE SYNTAX INTEGER { si1(1), si10(10), si30(30), si60(60), si900(900), si1800(1800), si3600(3600) } UNITS "seconds" MAX-ACCESS read-create STATUS current DESCRIPTION "Sample rate once per sample interval specified in seconds" DEFVAL { si30 } ::= { rcCfmPmEntry 14} -- Linktrace Reply Table CfmRelayActionFieldValue ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Possible values the Relay action field can take." REFERENCE "802.1ag clauses 12.14.7.5.3:g, 20.36.2.5, 21.9.5, and Table 21-27" SYNTAX INTEGER { rlyHit (1), rlyFdb (2), rlyMpdb (3), unknown (4) } CfmIngressActionFieldValue ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Possible values returned in the ingress action field." REFERENCE "802.1ag clauses 12.14.7.5.3:g, 20.36.2.6, 21.9.8.1, and Table 21-30" SYNTAX INTEGER { ingOk (1), ingDown (2), ingBlocked (3), ingVid (4), ingNoTlv (5) } CfmEgressActionFieldValue ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Possible values returned in the egress action field" REFERENCE "802.1ag clauses 12.14.7.5.3:o, 20.36.2.10, 21.9.9.1, and Table 21-32" SYNTAX INTEGER { egrOk (1), egrDown (2), egrBlocked (3), egrVid (4), egrNoTlv (5) } LldpPortIdSubtype ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This TC describes the source of a particular type of Port identifier used in the LLDP MIB. The enumeration 'interfaceAlias(1)' represents a port identifier based on the ifAlias MIB object, defined in IETF RFC 2863. The enumeration 'portComponent(2)' represents a port identifier based on the value of entPhysicalAlias (defined in IETF RFC 2737) for a port component (i.e., entPhysicalClass value of 'port(10)'), within the containing chassis. The enumeration 'macAddress(3)' represents a port identifier based on a unicast source address (encoded in network byte order and IEEE 802.3 canonical bit order), which has been detected by the agent and associated with a particular port (IEEE Std 802-2001). The enumeration 'networkAddress(4)' represents a port identifier based on a network address, detected by the agent and associated with a particular port. The enumeration 'interfaceName(5)' represents a port identifier based on the ifName MIB object, defined in IETF RFC 2863. The enumeration 'agentCircuitId(6)' represents a port identifier based on the agent-local identifier of the circuit (defined in RFC 3046), detected by the agent and associated with a particular port. The enumeration 'local(7)' represents a port identifier based on a value locally assigned." SYNTAX INTEGER { interfaceAlias(1), portComponent(2), macAddress(3), networkAddress(4), interfaceName(5), agentCircuitId(6), local(7) } LldpPortId ::= TEXTUAL-CONVENTION DISPLAY-HINT "1a" STATUS current DESCRIPTION "This TC describes the format of a port identifier string. Objects of this type are always used with an associated LldpPortIdSubtype object, which identifies the format of the particular LldpPortId object instance. If the associated LldpPortIdSubtype object has a value of '342/200/230interfaceAlias(1)', then the octet string identifies a particular instance of the ifAlias object (defined in IETF RFC 2863). If the particular ifAlias object does not contain any values, another port identifier type should be used. If the associated LldpPortIdSubtype object has a value of 'portComponent(2)', then the octet string identifies a particular instance of the entPhysicalAlias object (defined in IETF RFC 2737) for a port or backplane component. If the associated LldpPortIdSubtype object has a value of 'macAddress(3)', then this string identifies a Particular unicast source address (encoded in network byte order and IEEE 802.3 canonical bit order) associated with the port (IEEE Std 802-2001). If the associated LldpPortIdSubtype object has a value of 'networkAddress(4)', then this string identifies a Network address associated with the port. The first octet contains the IANA AddressFamilyNumbers enumeration value for the specific address type, and octets 2 through N contain the networkAddress address value in network byte order. If the associated LldpPortIdSubtype object has a value of 'interfaceName(5)', then the octet string identifies A particular instance of the ifName object (defined in IETF RFC 2863). If the particular ifName object does not contain any values, another port identifier type should be used. If the associated ldpPortIdSubtype object has a value of 'agentCircuitId(6)', then this string identifies a agent-local identifier of the circuit (defined in RFC 3046). If the associated LldpPortIdSubtype object has a value of '342/200/230local(7)', then this string identifies a locally assigned port ID." SYNTAX OCTET STRING (SIZE (1..255)) -- The Linktrace Reply Table rcCfmLtrTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCfmLtrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains a list of Linktrace replies received by a specific MEP in response to a linktrace message." ::= { rcCfm 32} rcCfmLtrEntry OBJECT-TYPE SYNTAX RcCfmLtrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Linktrace Reply table entry." INDEX {rcCfmLtrDomainIndex, rcCfmLtrAssociationIndex, rcCfmLtrMepId, rcCfmLtrSeqNumber, rcCfmLtrTtl, rcCfmLtrReceiveOrder} ::= { rcCfmLtrTable 1} RcCfmLtrEntry ::= SEQUENCE { rcCfmLtrDomainIndex Integer32, rcCfmLtrAssociationIndex Integer32, rcCfmLtrMepId Integer32, rcCfmLtrSeqNumber Integer32, rcCfmLtrTtl Integer32, rcCfmLtrReceiveOrder Integer32, rcCfmLtrDomainName DisplayString, rcCfmLtrAssociationName DisplayString, rcCfmLtrForwarded TruthValue, rcCfmLtrTerminalMep TruthValue, rcCfmLtrLastEgressIdentifier OCTET STRING, rcCfmLtrNextEgressIdentifier OCTET STRING, rcCfmLtrRelayAction CfmRelayActionFieldValue, rcCfmLtrSrcMac MacAddress, rcCfmLtrIngressAction CfmIngressActionFieldValue, rcCfmLtrIngressMac MacAddress, rcCfmLtrIngressPortIdSubtype LldpPortIdSubtype, rcCfmLtrIngressPortId LldpPortId, rcCfmLtrEgressAction CfmEgressActionFieldValue, rcCfmLtrEgressMac MacAddress, rcCfmLtrEgressPortIdSubtype LldpPortIdSubtype, rcCfmLtrEgressPortId LldpPortId } rcCfmLtrDomainIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Domain Index" ::= { rcCfmLtrEntry 1} rcCfmLtrAssociationIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance Association Index" ::= { rcCfmLtrEntry 2} rcCfmLtrMepId OBJECT-TYPE SYNTAX Integer32 (1..8191) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Maintenance EndPoint ID" ::= { rcCfmLtrEntry 3} rcCfmLtrSeqNumber OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The transaction identifier/sequence number returned by a previous transmit linkrace message command, indicating which LTM's response is going to be returned." ::= { rcCfmLtrEntry 4} rcCfmLtrTtl OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ttl field value for a returned LTR." ::= { rcCfmLtrEntry 5} rcCfmLtrReceiveOrder OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An index to distinguish among multiple LTRs with the same LTR Transaction Identifier field value. This value is assigned sequentially from 1, in the order that the Linktrace Initiator received the LTRs." ::= { rcCfmLtrEntry 6} rcCfmLtrDomainName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Domain Name" ::= { rcCfmLtrEntry 7} rcCfmLtrAssociationName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..22)) MAX-ACCESS read-only STATUS current DESCRIPTION "Maintenance Association Name" ::= { rcCfmLtrEntry 8} rcCfmLtrForwarded OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if a LTM was forwarded by the responding MP, as returned in the 'FwdYes' flag of the flags field." ::= { rcCfmLtrEntry 9} rcCfmLtrTerminalMep OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A boolean value stating whether the forwarded LTM reached a MEP enclosing its MA, as returned in the Terminal MEP flag of the Flags field." ::= { rcCfmLtrEntry 10} rcCfmLtrLastEgressIdentifier OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "An octet field holding the Last Egress Identifier returned in the LTR Egress Identifier TLV of the LTR. The Last Egress Identifier identifies the MEP Linktrace Indicator that originated, or the Linktrace Responder that forwarded, the LTM to which this LTR is the response. This is the same value as the Egress Identifier TLV of that LTM." ::= { rcCfmLtrEntry 11} rcCfmLtrNextEgressIdentifier OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "An octet field holding the Next Egress Identifier returned in the LTR Egress Identifier TLV of the LTR. The Next Egress Identifier Identifies the Linktrace Responder that transmitted this LTR, and can forward the LTM to the next hop. This is the same value as the Egress Identifier TLV of the forwarded LTM, if any. If the FwdYes bit of the Flags field is false, the contents of this field are undefined, and the field is ignored by the receiver." ::= { rcCfmLtrEntry 12} rcCfmLtrRelayAction OBJECT-TYPE SYNTAX CfmRelayActionFieldValue MAX-ACCESS read-only STATUS current DESCRIPTION "Value returned in the Relay Action field." DEFVAL { unknown } ::= { rcCfmLtrEntry 13} rcCfmLtrSrcMac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Mac address of the MP that respond to the LTM request for this LTR" ::= { rcCfmLtrEntry 14} rcCfmLtrIngressAction OBJECT-TYPE SYNTAX CfmIngressActionFieldValue MAX-ACCESS read-only STATUS current DESCRIPTION "The value returned in the Ingress Action Field of the LTM. The value ingNoTlv(5) indicates that no Reply Ingress TLV was returned in the LTM." ::= { rcCfmLtrEntry 15} rcCfmLtrIngressMac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Mac address returned in the ingress MAC address field. If the rcCfmLtrIngress object contains the value ingNoTlv(5), then the contents of this object are meaningless." ::= { rcCfmLtrEntry 16} rcCfmLtrIngressPortIdSubtype OBJECT-TYPE SYNTAX LldpPortIdSubtype MAX-ACCESS read-only STATUS current DESCRIPTION "Format of the Ingress Port ID. If the rcCfmLtrIngress object contains the value ingNoTlv(5), then the contents of this object are meaningless." ::= { rcCfmLtrEntry 17} rcCfmLtrIngressPortId OBJECT-TYPE SYNTAX LldpPortId MAX-ACCESS read-only STATUS current DESCRIPTION "Ingress Port ID. The format of this object is determined by the value of the rcCfmLtrIngressPortIdSubtype object. If the rcCfmLtrIngress object contains the value ingNoTlv(5), then the contents of this object are meaningless." ::= { rcCfmLtrEntry 18} rcCfmLtrEgressAction OBJECT-TYPE SYNTAX CfmEgressActionFieldValue MAX-ACCESS read-only STATUS current DESCRIPTION "The value returned in the Egress Action Field of the LTM. The value egrNoTlv(5) indicates that no Reply Egress TLV was returned in the LTM." ::= { rcCfmLtrEntry 19} rcCfmLtrEgressMac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Mac address returned in the egress MAC address field. If the rcCfmLtrEgress object contains the value egrNoTlv(5), then the contents of this object are meaningless." ::= { rcCfmLtrEntry 20} rcCfmLtrEgressPortIdSubtype OBJECT-TYPE SYNTAX LldpPortIdSubtype MAX-ACCESS read-only STATUS current DESCRIPTION "Format of the Egress Port ID. If the rcCfmLtrEgress object contains the value egrNoTlv(5), then the contents of this object are meaningless." ::= { rcCfmLtrEntry 21} rcCfmLtrEgressPortId OBJECT-TYPE SYNTAX LldpPortId MAX-ACCESS read-only STATUS current DESCRIPTION "Egress Port ID. The format of this object is determined by the value of the rcCfmLtrEgressPortIdSubtype object. If the rcCfmLtrEgress object contains the value egrNoTlv(5), then the contents of this object are meaningless." ::= { rcCfmLtrEntry 22} END