#-MIBFILE: cpqservice.mib CPQSERVICE-MIB DEFINITIONS ::= BEGIN compaq OBJECT IDENTIFIER ::= { enterprises 232 } DisplayString ::= OCTET STRING PhysAddress ::= OCTET STRING mib-2 OBJECT IDENTIFIER ::= { mgmt 1 } system OBJECT IDENTIFIER ::= { mib-2 1 } sysName OBJECT IDENTIFIER ::= { system 5 } cpqService OBJECT IDENTIFIER ::= { compaq 164 } cpqServiceMibRev OBJECT IDENTIFIER ::= { cpqService 1 } cpqServiceIncident OBJECT IDENTIFIER ::= { cpqService 2 } cpqServiceMibRevMajor OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The Major Revision level of the MIB. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the supported information. Correct interpretation of data may require a MIB document with the same major revision level." ::= { cpqServiceMibRev 2 } cpqServiceMibRevMinor OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The Minor Revision level of the MIB. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred." ::= { cpqServiceMibRev 1 } cpqServiceIncidentSeverity OBJECT-TYPE SYNTAX INTEGER { important(1), informational(2) } ACCESS read-only STATUS optional DESCRIPTION "The severity of the service incident." ::= { cpqServiceIncident 1 } cpqServiceIncidentStatus OBJECT-TYPE SYNTAX INTEGER { other(1), intransit(2), delivered(3), undelivered(4), assigned(5), closed(6), submitted_to_ISEE(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the service incident." ::= { cpqServiceIncident 2 } cpqServiceIncidentInformation OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Provides the URL to the event analysis report. " ::= { cpqServiceIncident 3 } cpqServiceIncidentEvent OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Brief description of the event that initiated the service incident." ::= { cpqServiceIncident 4 } cpqServiceIncidentUniqueID OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Unique Event Analysis Identifier assigned to the incident." ::= { cpqServiceIncident 5 } cpqServiceIncidentTimeofOriginalEvent OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Time of the original event this service event relates to." ::= { cpqServiceIncident 6 } cpqServiceIncidentSourceSystemName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Name of the system this service event relates to." ::= { cpqServiceIncident 7 } cpqServiceIncidentIPAddessOfSource OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP Address of the system this service event relates to." ::= { cpqServiceIncident 8 } cpqServiceISEEIncidentInformation OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This is a URL pointing to the Service Incident status in ISEE if available." ::= { cpqServiceIncident 9 } cpqServiceIncidentIdentifier OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Service Incident Identifier assigned to the incident report by the ISEE client." ::= { cpqServiceIncident 10 } cpqServiceIncidentReceiveTrapOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The ID of the originally received event." ::= { cpqServiceIncident 11 } cpqServiceIncidentFilterOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS optional DESCRIPTION "The OID of the value that is used by the OSEM filter." ::= { cpqServiceIncident 12 } cpqServiceIncidentFilterValue OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS optional DESCRIPTION "The value contained in the Filter OID." ::= { cpqServiceIncident 13 } cpqServiceRecommendedAction1 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Recommended action." ::= { cpqServiceIncident 14 } cpqServiceRecommendedAction2 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Recommended action continued" ::= { cpqServiceIncident 15 } cpqServiceRecommendedAction3 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Recommended action continued" ::= { cpqServiceIncident 16 } cpqServiceCustomerSelfRepairInstructionURL OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A URL pointing to additional repair information" ::= { cpqServiceIncident 17 } cpqServiceEventSeverity OBJECT-TYPE SYNTAX INTEGER { critical(1), major(2), minor(3), warning(4), informational(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The severity of the service incident." ::= { cpqServiceIncident 18 } cpqServiceAnalyzerSystemName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Name of the system this service event was analyzed on." ::= { cpqServiceIncident 19 } cpqServiceFRUList1 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Replaceable Unit information" ::= { cpqServiceIncident 20 } cpqServiceFRUList2 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Replaceable Unit information continued" ::= { cpqServiceIncident 21 } cpqServiceFRUList3 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Replaceable Unit information continued" ::= { cpqServiceIncident 22 } cpqServiceFRUList4 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Replaceable Unit information continued" ::= { cpqServiceIncident 23 } cpqServiceLocation1 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Replaceable Unit location" ::= { cpqServiceIncident 24 } cpqServiceLocation2 OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Replaceable Unit location continued" ::= { cpqServiceIncident 25 } cpqServiceInformation TRAP-TYPE ENTERPRISE cpqService VARIABLES { sysName, cpqServiceIncidentSeverity, cpqServiceIncidentStatus, cpqServiceIncidentInformation, cpqServiceIncidentEvent, cpqServiceIncidentUniqueID, cpqServiceIncidentTimeofOriginalEvent, cpqServiceIncidentSourceSystemName, cpqServiceIncidentIPAddessOfSource, cpqServiceISEEIncidentInformation, cpqServiceIncidentIdentifier, cpqServiceIncidentReceiveTrapOID, cpqServiceIncidentFilterOID, cpqServiceIncidentFilterValue } --#TYPE "A Service Incident has been reported (Type 1)." --#SUMMARY "%s reported an %s Service Incident Trap whose status is located at %s." --#ARGUMENTS {0, 2, 3} --#SEVERITY MAJOR --#TIMEINDEX 18 --#CATEGORY "HP Service Events" --#ENABLE true --#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.ServiceTrapDisplayHandler" --#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.ServiceTrapRuleHandler" DESCRIPTION "This trap will be sent any time a service incident is logged or updated. A service incident is generated when it is determined that a service event has occurred based upon an analysis of system initiated event traps or an update to a service event has occurred. User Action: None Required" ::= 164001 cpqService2Information TRAP-TYPE ENTERPRISE cpqService VARIABLES { sysName, cpqServiceIncidentStatus, cpqServiceIncidentInformation, cpqServiceIncidentEvent, cpqServiceIncidentUniqueID, cpqServiceIncidentTimeofOriginalEvent, cpqServiceIncidentSourceSystemName, cpqServiceIncidentIPAddessOfSource, cpqServiceISEEIncidentInformation, cpqServiceIncidentIdentifier, cpqServiceIncidentReceiveTrapOID, cpqServiceRecommendedAction1, cpqServiceRecommendedAction2, cpqServiceRecommendedAction3, cpqServiceCustomerSelfRepairInstructionURL } --#TYPE "A Service Incident has been reported (Type 2)." --#SUMMARY "%s reported a Service Incident Trap whose status is located at %s." --#ARGUMENTS {0, 1} --#SEVERITY MAJOR --#TIMEINDEX 18 --#CATEGORY "HP Service Events" --#ENABLE true --#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.ServiceTrapDisplayHandler" --#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.ServiceTrapRuleHandler" DESCRIPTION "This event will be sent any time a service incident is reported. A service incident is generated when it is determined that a serviceable event has occurred based upon analysis of system-initiated events. User Action: Refer to the Recommended Action section under the event details section" ::= 164002 cpqService3Information TRAP-TYPE ENTERPRISE cpqService VARIABLES { cpqServiceIncidentSourceSystemName, cpqServiceIncidentIPAddessOfSource, cpqServiceEventSeverity, cpqServiceIncidentStatus, cpqServiceIncidentInformation, cpqServiceIncidentEvent, cpqServiceIncidentUniqueID, cpqServiceIncidentTimeofOriginalEvent, cpqServiceAnalyzerSystemName, cpqServiceISEEIncidentInformation, cpqServiceIncidentIdentifier, cpqServiceIncidentReceiveTrapOID, cpqServiceRecommendedAction1, cpqServiceRecommendedAction2, cpqServiceRecommendedAction3, cpqServiceFRUList1, cpqServiceFRUList2, cpqServiceFRUList3, cpqServiceFRUList4, cpqServiceLocation1, cpqServiceLocation2, cpqServiceCustomerSelfRepairInstructionURL } --#TYPE "A Service Incident has been reported (Type 3)." --#SUMMARY "%s reported a Service Incident Trap whose status is located at %s." --#ARGUMENTS {0, 4} --#SEVERITY MAJOR --#TIMEINDEX 18 --#CATEGORY "HP Service Events" --#ENABLE true --#VARBINDSEVERITY 3 --#SEVERITYMAP "INFORMATIONAL = INFORMATIONAL, MINOR = MINOR, WARNING = WARNING, MAJOR = MAJOR, CRITICAL = CRITICAL,5 = INFORMATIONAL, 4 = WARNING, 3=MINOR, 2 = MAJOR, 1 = CRITICAL" --#NOTICE_HANDLER "com.hp.mx.portal.alerts.handlers.ServiceTrapDisplayHandler" --#RULE_HANDLER "com.hp.mx.core.protocol.snmp.trap.components.ServiceTrapRuleHandler" DESCRIPTION "This event will be sent any time a service incident is reported. A service incident is generated when it is determined that a serviceable event has occurred based upon analysis of system-initiated events. User Action: Refer to the Recommended Action section under the event details section" ::= 164003 END