#-MIBFILE: cpqcmc.mib CPQCMC-MIB DEFINITIONS ::= BEGIN compaq OBJECT IDENTIFIER ::= { enterprises 232 } DisplayString ::= OCTET STRING PhysAddress ::= OCTET STRING mib-2 OBJECT IDENTIFIER ::= { mgmt 1 } system OBJECT IDENTIFIER ::= { mib-2 1 } sysName OBJECT IDENTIFIER ::= { system 5 } mib-2 OBJECT IDENTIFIER ::= { mgmt 1 } sysContact OBJECT IDENTIFIER ::= { system 4 } sysLocation OBJECT IDENTIFIER ::= { system 6 } sysDescr OBJECT IDENTIFIER ::= { system 1 } cpqCmc OBJECT IDENTIFIER ::= { compaq 153 } cpqCmcMibRev OBJECT IDENTIFIER ::= { cpqCmc 1 } cpqCmcComponent OBJECT IDENTIFIER ::= { cpqCmc 2 } cpqCmcInterface OBJECT IDENTIFIER ::= { cpqCmcComponent 1 } cpqCmcOsCommon OBJECT IDENTIFIER ::= { cpqCmcInterface 1 } cpqCmcDevice OBJECT IDENTIFIER ::= { cpqCmcComponent 2 } cpqCmcSetup OBJECT IDENTIFIER ::= { cpqCmcDevice 2 } cpqCmcSetupConfig OBJECT IDENTIFIER ::= { cpqCmcSetup 1 } cpqCmcSetupGeneral OBJECT IDENTIFIER ::= { cpqCmcSetupConfig 1 } cpqCmcSetupEvents OBJECT IDENTIFIER ::= { cpqCmcSetupConfig 2 } cpqCmcSetupTemp1 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 1 } cpqCmcSetupTemp2 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 2 } cpqCmcSetupFan1 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 3 } cpqCmcSetupFan2 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 4 } cpqCmcSetupVoltage OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 5 } cpqCmcSetupHumidity OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 6 } cpqCmcSetupInput1 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 7 } cpqCmcSetupInput2 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 8 } cpqCmcSetupInput3 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 9 } cpqCmcSetupInput4 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 10 } cpqCmcSetupLock1 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 11 } cpqCmcSetupLock2 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 12 } cpqCmcSetupSmoke OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 13 } cpqCmcSetupShock OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 14 } cpqCmcSetupAux1 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 15 } cpqCmcSetupAux2 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 16 } cpqCmcSetupAlarm1 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 17 } cpqCmcSetupAlarm2 OBJECT IDENTIFIER ::= { cpqCmcSetupEvents 18 } cpqCmcSetupClock OBJECT IDENTIFIER ::= { cpqCmcSetupConfig 3 } cpqCmcSetupThreshold OBJECT IDENTIFIER ::= { cpqCmcSetup 2 } cpqCmcTraps OBJECT IDENTIFIER ::= { cpqCmcSetup 3 } cpqCmcValues OBJECT IDENTIFIER ::= { cpqCmcDevice 3 } cpqCmcStatus OBJECT IDENTIFIER ::= { cpqCmcDevice 4 } cpqCmcControl OBJECT IDENTIFIER ::= { cpqCmcDevice 5 } cpqCmcLog OBJECT IDENTIFIER ::= { cpqCmcDevice 6 } cpqCmcMibRevMajor OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information, correct interpretation of data may require a MIB document with the same major revision level." ::= { cpqCmcMibRev 1 } cpqCmcMibRevMinor OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The Minor Revision level. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred." ::= { cpqCmcMibRev 2 } cpqCmcMibCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The overall condition (status) of the system (rack(s)) represented by this MIB. (2) OK (3) a minor problem, warning condition (yellow LED on CMC) (4) a major problem (red LED on CMC)" ::= { cpqCmcMibRev 3 } cpqCmcOsCommonPollFreq OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The Insight Agent's polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero (0) indicates that the Insight Agent retrieves the information upon request of a management station, it does not poll the device driver at a specific interval." ::= { cpqCmcOsCommon 1 } cpqCmcDeviceCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), overloadDC(3), fuseDC(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Condition of CMC device, (3) an overload of the 24V DC supply to the connected accessories occurred (4) the overload-protection (fuse) has released " ::= { cpqCmcDevice 1 } cpqCmcsetLanguage OBJECT-TYPE SYNTAX INTEGER { other(1), english(2), french(3), italian(4), german(5), spanish(6), dutch(7), japanese(8) } ACCESS read-only STATUS mandatory DESCRIPTION "Language of LCD" ::= { cpqCmcSetupGeneral 1 } cpqCmcsetTempUnit OBJECT-TYPE SYNTAX INTEGER { other(1), celsius(2), fahrenheit(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Unit of all temperature values and thresholds, Celsius or Fahrenheit" ::= { cpqCmcSetupGeneral 2 } cpqCmcsetAudibleAlarm OBJECT-TYPE SYNTAX INTEGER { other(1), enableSilence(2), disableSilence(3), off(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Audible alarm in CMC unit: (2): silencing with button on CMC is enabled (3): silencing with button on CMC is disabled (4): audible alarm is off (general). On/off of audible alarm for each event is possible in cpqCmcsetupEvents-group" ::= { cpqCmcSetupGeneral 3 } cpqCmcPassword OBJECT-TYPE SYNTAX DisplayString (SIZE(0..6)) ACCESS read-only STATUS mandatory DESCRIPTION "Password to get access to terminal or LCD" ::= { cpqCmcSetupGeneral 4 } cpqCmcPasswordOption OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Enable or disable password entry to get access to terminal or LCD" ::= { cpqCmcSetupGeneral 5 } cpqCmcquitRelay1 OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Enable or disable acknowledging currently active alarm relay 1 (with 'ENTER' on CMC)." ::= { cpqCmcSetupGeneral 6 } cpqCmcquitRelay2 OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Enable or disable acknowledging currently active alarm relay 2 (with 'ENTER' on CMC)." ::= { cpqCmcSetupGeneral 7 } cpqCmclogicRelay1 OBJECT-TYPE SYNTAX INTEGER { other(1), closeAtAlarm(2), openAtAlarm(3), closeAtEPO(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Logic of Relay 1: (2) Relay will pick up in case of an alarm (3) Relay will release in case of an alarm (4) not used" ::= { cpqCmcSetupGeneral 8 } cpqCmclogicRelay2 OBJECT-TYPE SYNTAX INTEGER { other(1), closeAtAlarm(2), openAtAlarm(3), closeAtEPO(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Logic of Relay 2: (2) Relay will pick up in case of an alarm (3) Relay will release in case of an alarm (4) not used" ::= { cpqCmcSetupGeneral 9 } cpqCmcSetupTemp1Avail OBJECT-TYPE SYNTAX INTEGER { other(1), available(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Temperature sensor: (2) sensor available (3) sensor not available" ::= { cpqCmcSetupTemp1 1 } cpqCmcSetupTemp1RelaysWarn OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of warning condition of temperature sensor 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupTemp1 2 } cpqCmcSetupTemp1RelaysMax OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of max. alarm condition of temperature sensor 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupTemp1 3 } cpqCmcSetupTemp1RelaysMin OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of min. alarm condition of temperature sensor 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupTemp1 4 } cpqCmcSetupTemp1AudibleAlarmWarn OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of warning condition of temperature sensor 1: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupTemp1 5 } cpqCmcSetupTemp1AudibleAlarmMax OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of max. alarm condition of temperature sensor 1: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupTemp1 6 } cpqCmcSetupTemp1AudibleAlarmMin OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of min. alarm condition of temperature sensor 1: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupTemp1 7 } cpqCmcSetupTemp2Avail OBJECT-TYPE SYNTAX INTEGER { other(1), available(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Temperature sensor: (2) sensor available (3) sensor not available" ::= { cpqCmcSetupTemp2 1 } cpqCmcSetupTemp2RelaysWarn OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of warning condition of temperature sensor 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupTemp2 2 } cpqCmcSetupTemp2RelaysMax OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of max. alarm condition of temperature sensor 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupTemp2 3 } cpqCmcSetupTemp2RelaysMin OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of min. alarm condition of temperature sensor 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupTemp2 4 } cpqCmcSetupTemp2AudibleAlarmWarn OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of warning condition of temperature sensor 2: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupTemp2 5 } cpqCmcSetupTemp2AudibleAlarmMax OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of max. alarm condition of temperature sensor 2: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupTemp2 6 } cpqCmcSetupTemp2AudibleAlarmMin OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of min. alarm condition of temperature sensor 2: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupTemp2 7 } cpqCmcSetupFan1Avail OBJECT-TYPE SYNTAX INTEGER { other(1), available(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Fan 1: (2) Fan 1 available (3) Fan 1 not available" ::= { cpqCmcSetupFan1 1 } cpqCmcSetupFan1Relays OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of alarm condition of Fan 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupFan1 2 } cpqCmcSetupFan1AudibleAlarm OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of alarm condition of Fan 1: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupFan1 3 } cpqCmcSetupFan2Avail OBJECT-TYPE SYNTAX INTEGER { other(1), available(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Fan 2: (2) Fan 2 available (3) Fan 2 not available" ::= { cpqCmcSetupFan2 1 } cpqCmcSetupFan2Relays OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of alarm condition of Fan 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupFan2 2 } cpqCmcSetupFan2AudibleAlarm OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of alarm condition of Fan 2: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupFan2 3 } cpqCmcSetupVoltageAvail OBJECT-TYPE SYNTAX INTEGER { other(1), available(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Voltage monitoring: (2) available (3) not available" ::= { cpqCmcSetupVoltage 1 } cpqCmcSetupVoltageRelaysMax OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of max. alarm condition of voltage monitoring: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupVoltage 2 } cpqCmcSetupVoltageRelaysMin OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of min. alarm condition of voltage monitoring: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupVoltage 3 } cpqCmcSetupVoltageAudibleAlarmMax OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of max. alarm condition of voltage monitoring: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupVoltage 4 } cpqCmcSetupVoltageAudibleAlarmMin OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of min. alarm condition of voltage monitoring: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupVoltage 5 } cpqCmcSetupHumidityAvail OBJECT-TYPE SYNTAX INTEGER { other(1), available(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Humidity sensor: (2) available (3) not available" ::= { cpqCmcSetupHumidity 1 } cpqCmcSetupHumidityRelaysMax OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of max. alarm condition of humidity monitoring: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupHumidity 2 } cpqCmcSetupHumidityRelaysMin OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of min. alarm condition of humidity monitoring: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupHumidity 3 } cpqCmcSetupHumidityAudibleAlarmMax OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of max. alarm condition of humidity monitoring: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupHumidity 4 } cpqCmcSetupHumidityAudibleAlarmMin OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of min. alarm condition of humidity monitoring: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupHumidity 5 } cpqCmcSetupInput1Avail OBJECT-TYPE SYNTAX INTEGER { other(1), available(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Input 1 sensor: (2) available (3) not available" ::= { cpqCmcSetupInput1 1 } cpqCmcSetupInput1Relays OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of a warning condition of Input 1 (Door/Sidewall open): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupInput1 2 } cpqCmcSetupInput1AudibleAlarm OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of a warning condition of Input 1 (Door/Sidewall open): (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupInput1 3 } cpqCmcSetupInput1FansOff OBJECT-TYPE SYNTAX INTEGER { other(1), both(2), fan1(3), fan2(4), noFan(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Fan switching off if Door/Sidewall 1 is opened: (2) both fans would be switched off (3) only fan1 will be switched off (4) only fan2 will be switched off (5) no fan will be switched off" ::= { cpqCmcSetupInput1 4 } cpqCmcSetupInput1ShockSensor OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), on(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Shock sensor function if Door/Sidewall 1 is opened: (2) Shock Sensor is off (disabled) (3) Shock Sensor is on (enabled)" ::= { cpqCmcSetupInput1 5 } cpqCmcSetupInput1Description OBJECT-TYPE SYNTAX DisplayString (SIZE(0..18)) ACCESS read-only STATUS mandatory DESCRIPTION "Descriptional text of Input1" ::= { cpqCmcSetupInput1 6 } cpqCmcSetupInput1Lock OBJECT-TYPE SYNTAX INTEGER { other(1), none(2), lock1(3), lock2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Door/Sidewall 1 is locked by: (2) no locking device (3) locking device 1 (4) locking device 2 (5) both locking devices" ::= { cpqCmcSetupInput1 7 } cpqCmcSetupInput2Avail OBJECT-TYPE SYNTAX INTEGER { other(1), available(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Input 2 sensor: (2) available (3) not available" ::= { cpqCmcSetupInput2 1 } cpqCmcSetupInput2Relays OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of a warning condition of Input 2 (Door/Sidewall open): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupInput2 2 } cpqCmcSetupInput2AudibleAlarm OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of a warning condition of Input 2 (Door/Sidewall open): (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupInput2 3 } cpqCmcSetupInput2FansOff OBJECT-TYPE SYNTAX INTEGER { other(1), both(2), fan1(3), fan2(4), noFan(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Fan switching off if Door/Sidewall 2 is opened: (2) both fans would be switched off (3) only fan1 will be switched off (4) only fan2 will be switched off (5) no fan will be switched off" ::= { cpqCmcSetupInput2 4 } cpqCmcSetupInput2ShockSensor OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), on(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Shock sensor function if Door/Sidewall 2 is opened: (2) Shock Sensor is off (disabled) (3) Shock Sensor is on (enabled)" ::= { cpqCmcSetupInput2 5 } cpqCmcSetupInput2Description OBJECT-TYPE SYNTAX DisplayString (SIZE(0..18)) ACCESS read-only STATUS mandatory DESCRIPTION "Descriptional text of Input2" ::= { cpqCmcSetupInput2 6 } cpqCmcSetupInput2Lock OBJECT-TYPE SYNTAX INTEGER { other(1), none(2), lock1(3), lock2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Door/Sidewall 2 is locked by: (2) no locking device (3) locking device 1 (4) locking device 2 (5) both locking devices" ::= { cpqCmcSetupInput2 7 } cpqCmcSetupInput3Avail OBJECT-TYPE SYNTAX INTEGER { other(1), available(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Input 3 sensor: (2) available (3) not available" ::= { cpqCmcSetupInput3 1 } cpqCmcSetupInput3Relays OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of a warning condition of Input 3 (Door/Sidewall open): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupInput3 2 } cpqCmcSetupInput3AudibleAlarm OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of a warning condition of Input 3 (Door/Sidewall open): (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupInput3 3 } cpqCmcSetupInput3FansOff OBJECT-TYPE SYNTAX INTEGER { other(1), both(2), fan1(3), fan2(4), noFan(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Fan switching off if Door/Sidewall 3 is opened: (2) both fans would be switched off (3) only fan1 will be switched off (4) only fan2 will be switched off (5) no fan will be switched off" ::= { cpqCmcSetupInput3 4 } cpqCmcSetupInput3ShockSensor OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), on(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Shock sensor function if Door/Sidewall 3 is opened: (2) Shock Sensor is off (disabled) (3) Shock Sensor is on (enabled)" ::= { cpqCmcSetupInput3 5 } cpqCmcSetupInput3Description OBJECT-TYPE SYNTAX DisplayString (SIZE(0..18)) ACCESS read-only STATUS mandatory DESCRIPTION "Descriptional text of Input3" ::= { cpqCmcSetupInput3 6 } cpqCmcSetupInput3Lock OBJECT-TYPE SYNTAX INTEGER { other(1), none(2), lock1(3), lock2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Door/Sidewall 3 is locked by: (2) no locking device (3) locking device 1 (4) locking device 2 (5) both locking devices" ::= { cpqCmcSetupInput3 7 } cpqCmcSetupInput4Avail OBJECT-TYPE SYNTAX INTEGER { other(1), available(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Input 4 sensor: (2) available (3) not available" ::= { cpqCmcSetupInput4 1 } cpqCmcSetupInput4Relays OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of a warning condition of Input 4 (Door/Sidewall open): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupInput4 2 } cpqCmcSetupInput4AudibleAlarm OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of a warning condition of Input 4 (Door/Sidewall open): (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupInput4 3 } cpqCmcSetupInput4FansOff OBJECT-TYPE SYNTAX INTEGER { other(1), both(2), fan1(3), fan2(4), noFan(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Fan switching off if Door/Sidewall 4 is opened: (2) both fans would be switched off (3) only fan1 will be switched off (4) only fan2 will be switched off (5) no fan will be switched off" ::= { cpqCmcSetupInput4 4 } cpqCmcSetupInput4ShockSensor OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), on(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Shock sensor function if Door/Sidewall 4 is opened: (2) Shock Sensor is off (disabled) (3) Shock Sensor is on (enabled)" ::= { cpqCmcSetupInput4 5 } cpqCmcSetupInput4Description OBJECT-TYPE SYNTAX DisplayString (SIZE(0..18)) ACCESS read-only STATUS mandatory DESCRIPTION "Descriptional text of Input4" ::= { cpqCmcSetupInput4 6 } cpqCmcSetupInput4Lock OBJECT-TYPE SYNTAX INTEGER { other(1), none(2), lock1(3), lock2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Door/Sidewall 4 is locked by: (2) no locking device (3) locking device 1 (4) locking device 2 (5) both locking devices" ::= { cpqCmcSetupInput4 7 } cpqCmcSetupLock1Avail OBJECT-TYPE SYNTAX INTEGER { other(1), available(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Door locking device 1: (2) device available (3) device not available, no alarm, if door is not locked" ::= { cpqCmcSetupLock1 1 } cpqCmcSetupLock1Relays OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition of Lock 1 (door not locked..): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupLock1 2 } cpqCmcSetupLock1RelaysDevice OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition of Locking device 1 (power fail, low battery...): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupLock1 3 } cpqCmcSetupLock1AudibleAlarm OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition of Lock 1: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupLock1 4 } cpqCmcSetupLock1AudibleAlarmDevice OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition of Locking device 1 (power fail, low battery..): (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupLock1 5 } cpqCmcSetupLock1Time OBJECT-TYPE SYNTAX INTEGER (3..600) ACCESS read-only STATUS mandatory DESCRIPTION "Time in seconds while the lock 1 is unlocked after getting an unlock-command" ::= { cpqCmcSetupLock1 6 } cpqCmcSetupLock1PwrFailUnlock OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), auto(3), manual(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Unlock door in case of power fail of locking device: (2) disabled (3) auto unlock the door (4) unlock door with remote signal" ::= { cpqCmcSetupLock1 7 } cpqCmcSetupLock1BattLowUnlock OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), auto(3), manual(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Unlock door in case of low battery of locking device: (2) disabled (3) auto unlock the door (4) unlock door with remote signal" ::= { cpqCmcSetupLock1 8 } cpqCmcSetupLock1NetFailUnlock OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), auto(3), manual(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Unlock door in case of network failure: (2) disabled (3) auto unlock the door (4) unlock door with remote signal" ::= { cpqCmcSetupLock1 9 } cpqCmcSetupLock1LifeFailUnlock OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), auto(3), manual(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Unlock door in case of lifecheck failure (connection CMC<->locking device): (2) disabled (3) auto unlock the door (4) unlock door with remote signal" ::= { cpqCmcSetupLock1 10 } cpqCmcSetupLock2Avail OBJECT-TYPE SYNTAX INTEGER { other(1), available(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Door locking device 2: (2) device available (3) device not available, no alarm, if door is not locked" ::= { cpqCmcSetupLock2 1 } cpqCmcSetupLock2Relays OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition of Lock 2 (door not locked..): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupLock2 2 } cpqCmcSetupLock2RelaysDevice OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition of Locking device 2 (power fail, low battery...): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupLock2 3 } cpqCmcSetupLock2AudibleAlarm OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition of Lock 2: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupLock2 4 } cpqCmcSetupLock2AudibleAlarmDevice OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition of Locking device 2 (power fail, low battery..): (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupLock2 5 } cpqCmcSetupLock2Time OBJECT-TYPE SYNTAX INTEGER (3..600) ACCESS read-only STATUS mandatory DESCRIPTION "Time in seconds while the lock 2 is unlocked after getting an unlock-command" ::= { cpqCmcSetupLock2 6 } cpqCmcSetupLock2PwrFailUnlock OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), auto(3), manual(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Unlock door in case of power fail of locking device: (2) disabled (3) auto unlock the door (4) unlock door with remote signal" ::= { cpqCmcSetupLock2 7 } cpqCmcSetupLock2BattLowUnlock OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), auto(3), manual(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Unlock door in case of low battery of locking device: (2) disabled (3) auto unlock the door (4) unlock door with remote signal" ::= { cpqCmcSetupLock2 8 } cpqCmcSetupLock2NetFailUnlock OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), auto(3), manual(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Unlock door in case of network failure: (2) disabled (3) auto unlock the door (4) unlock door with remote signal" ::= { cpqCmcSetupLock2 9 } cpqCmcSetupLock2LifeFailUnlock OBJECT-TYPE SYNTAX INTEGER { other(1), disabled(2), auto(3), manual(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Unlock door in case of lifecheck failure (connection CMC<->locking device): (2) disabled (3) auto unlock the door (4) unlock door with remote signal" ::= { cpqCmcSetupLock2 10 } cpqCmcSetupSmokeAvail OBJECT-TYPE SYNTAX INTEGER { other(1), available(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Smoke sensor: (2) available (3) not available" ::= { cpqCmcSetupSmoke 1 } cpqCmcSetupSmokeRelays OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition of Smoke Sensor: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupSmoke 2 } cpqCmcSetupSmokeAudibleAlarm OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition of Smoke Sensor: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupSmoke 3 } cpqCmcSetupSmokeFansOff OBJECT-TYPE SYNTAX INTEGER { other(1), both(2), fan1(3), fan2(4), noFan(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Fan switching off if in case of smoke-alarm: (2) both fans would be switched off (3) only fan1 will be switched off (4) only fan2 will be switched off (5) no fan will be switched off" ::= { cpqCmcSetupSmoke 4 } cpqCmcSetupSmokeUnlock OBJECT-TYPE SYNTAX INTEGER { other(1), both(2), lock1(3), lock2(4), noLock(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Lock is unlocked in case of smoke-alarm: (2) both locks will be unlocked (3) only lock1 will be unlocked (4) only lock2 will be unlocked (5) no lock will be unlocked" ::= { cpqCmcSetupSmoke 5 } cpqCmcSetupShockAvail OBJECT-TYPE SYNTAX INTEGER { other(1), available(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Shock sensor: (2) available (3) not available" ::= { cpqCmcSetupShock 1 } cpqCmcSetupShockRelays OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition of Shock Sensor: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupShock 2 } cpqCmcSetupShockAudibleAlarm OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition of Shock Sensor: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupShock 3 } cpqCmcSetupShockSensitivity OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-only STATUS mandatory DESCRIPTION "Sensitivity of shock-sensor. 1 = low sensitivity, 10 = high sensitivity" ::= { cpqCmcSetupShock 4 } cpqCmcSetupAux1Avail OBJECT-TYPE SYNTAX INTEGER { other(1), available(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Aux 1 sensor: (2) available (3) not available" ::= { cpqCmcSetupAux1 1 } cpqCmcSetupAux1Relays OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition of Aux 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupAux1 2 } cpqCmcSetupAux1AudibleAlarm OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition of Aux 1: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupAux1 3 } cpqCmcSetupAux1InputType OBJECT-TYPE SYNTAX INTEGER { other(1), normOpen(2), normClosed(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of other digital input (used for any digital signal): (2) contact is normally open, no alarm if contact is open, alarm if contact is closed (3) contact is normally closed, no alarm if contact is closed, alarm if contact is open" ::= { cpqCmcSetupAux1 4 } cpqCmcSetupAux1Description OBJECT-TYPE SYNTAX DisplayString (SIZE(0..18)) ACCESS read-only STATUS mandatory DESCRIPTION "Descriptional text of the digital input (Aux1) " ::= { cpqCmcSetupAux1 5 } cpqCmcSetupAux1Unlock OBJECT-TYPE SYNTAX INTEGER { other(1), noLock(2), lock1(3), lock2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Lock will be unlocked with Aux-Input 1: (2) no lock will be unlocked (3) only lock1 will be unlocked (4) only lock2 will be unlocked (5) both locks will be unlocked" ::= { cpqCmcSetupAux1 6 } cpqCmcSetupAux2Avail OBJECT-TYPE SYNTAX INTEGER { other(1), available(2), notAvailable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Aux 2 sensor: (2) available (3) not available" ::= { cpqCmcSetupAux2 1 } cpqCmcSetupAux2Relays OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition of Aux 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupAux2 2 } cpqCmcSetupAux2AudibleAlarm OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition of Aux 2: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupAux2 3 } cpqCmcSetupAux2InputType OBJECT-TYPE SYNTAX INTEGER { other(1), normOpen(2), normClosed(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Type of other digital input (used for any digital signal): (2) contact is normally open, no alarm if contact is open, alarm if contact is closed (3) contact is normally closed, no alarm if contact is closed, alarm if contact is open" ::= { cpqCmcSetupAux2 4 } cpqCmcSetupAux2Description OBJECT-TYPE SYNTAX DisplayString (SIZE(0..18)) ACCESS read-only STATUS mandatory DESCRIPTION "Descriptional text of the digital input (Aux2) " ::= { cpqCmcSetupAux2 5 } cpqCmcSetupAux2Unlock OBJECT-TYPE SYNTAX INTEGER { other(1), noLock(2), lock1(3), lock2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Lock will be unlocked with Aux-Input 2: (2) no lock will be unlocked (3) only lock1 will be unlocked (4) only lock2 will be unlocked (5) both locks will be unlocked" ::= { cpqCmcSetupAux2 6 } cpqCmcSetupAlarm1Relays OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition of Alarm 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupAlarm1 1 } cpqCmcSetupAlarm1AudibleAlarm OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition of Alarm 1: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupAlarm1 2 } cpqCmcSetupAlarm1Description OBJECT-TYPE SYNTAX DisplayString (SIZE(0..18)) ACCESS read-only STATUS mandatory DESCRIPTION "Descriptional text of alarm 1" ::= { cpqCmcSetupAlarm1 3 } cpqCmcSetupAlarm2Relays OBJECT-TYPE SYNTAX INTEGER { other(1), off(2), relay1(3), relay2(4), both(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Alarm Relays in case of an alarm condition of Alarm 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch" ::= { cpqCmcSetupAlarm2 1 } cpqCmcSetupAlarm2AudibleAlarm OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Alert handling of Audible Alarm of in case of an alarm condition of Alarm 2: (2) Start Audible Alarm (3) No Audible Alarm" ::= { cpqCmcSetupAlarm2 2 } cpqCmcSetupAlarm2Description OBJECT-TYPE SYNTAX DisplayString (SIZE(0..18)) ACCESS read-only STATUS mandatory DESCRIPTION "Descriptional text of alarm 2" ::= { cpqCmcSetupAlarm2 3 } cpqCmcSetupDate OBJECT-TYPE SYNTAX DisplayString (SIZE(0..10)) ACCESS read-only STATUS mandatory DESCRIPTION "actual Date in format DD.MM.YYYY" ::= { cpqCmcSetupClock 1 } cpqCmcSetupTime OBJECT-TYPE SYNTAX DisplayString (SIZE(0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "actual Time in format HH:MM:SS, HH (0-23), MM (0-59), SS (0-59)" ::= { cpqCmcSetupClock 2 } cpqCmcThresholdMaxTemp1 OBJECT-TYPE SYNTAX INTEGER (0..200) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold value maximum temperature 1" ::= { cpqCmcSetupThreshold 1 } cpqCmcThresholdWarningTemp1 OBJECT-TYPE SYNTAX INTEGER (0..200) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold value warning temperature 1" ::= { cpqCmcSetupThreshold 2 } cpqCmcThresholdMinTemp1 OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold value minimum temperature 1" ::= { cpqCmcSetupThreshold 3 } cpqCmcThresholdMaxTemp2 OBJECT-TYPE SYNTAX INTEGER (0..200) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold value maximum temperature 2" ::= { cpqCmcSetupThreshold 4 } cpqCmcThresholdWarningTemp2 OBJECT-TYPE SYNTAX INTEGER (0..200) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold value warning temperature 2" ::= { cpqCmcSetupThreshold 5 } cpqCmcThresholdMinTemp2 OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold value minimum temperature 2" ::= { cpqCmcSetupThreshold 6 } cpqCmcThresholdFan1 OBJECT-TYPE SYNTAX INTEGER (0..200) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold Fan 1 in deg F or deg C, Fan 1 will start if temperature 1 exceeds this value" ::= { cpqCmcSetupThreshold 7 } cpqCmcThresholdFan1Hysteresis OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-only STATUS mandatory DESCRIPTION "Hystersis of Fan 1, Fan 1 will stop if temperature 1 falls below value of cpqCmcThresholdFan1 minus cpqCmcThresholdFan1Hysteresis" ::= { cpqCmcSetupThreshold 8 } cpqCmcThresholdFan2 OBJECT-TYPE SYNTAX INTEGER (0..200) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold Fan 2 in deg F or deg C, Fan 2 will start if temperature 2 exceeds this value" ::= { cpqCmcSetupThreshold 9 } cpqCmcThresholdFan2Hysteresis OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-only STATUS mandatory DESCRIPTION "Hystersis of Fan 2, Fan 2 will stop if temperature 2 falls below value of cpqCmcThresholdFan2 minus cpqCmcThresholdFan2Hysteresis" ::= { cpqCmcSetupThreshold 10 } cpqCmcThresholdMaxVoltage OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold high value Voltage alarm" ::= { cpqCmcSetupThreshold 11 } cpqCmcThresholdMinVoltage OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold low value Voltage alarm" ::= { cpqCmcSetupThreshold 12 } cpqCmcThresholdMaxHumidity OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold high value Humidity alarm" ::= { cpqCmcSetupThreshold 13 } cpqCmcThresholdMinHumidity OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Threshold low value Humidity alarm" ::= { cpqCmcSetupThreshold 14 } cpqCmcTrapTableNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of trapTable entries. The number of trap-receivers" ::= { cpqCmcTraps 1 } cpqCmcTrapTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqCmcTrapEntry ACCESS read-only STATUS mandatory DESCRIPTION "A list of trap-receiver entries" ::= { cpqCmcTraps 2 } cpqCmcTrapEntry OBJECT-TYPE SYNTAX CpqCmcTrapEntry ACCESS read-only STATUS mandatory DESCRIPTION "Entries of trapTable" INDEX { cpqCmcTrapIndex } ::= { cpqCmcTrapTable 1 } cpqCmcTrapEntry ::= SEQUENCE { cpqCmcTrapIndex INTEGER, cpqCmcTrapStatus INTEGER, cpqCmcTrapIPaddress DisplayString } cpqCmcTrapIndex OBJECT-TYPE SYNTAX INTEGER (1..4) ACCESS read-only STATUS mandatory DESCRIPTION "Index for the trap-receiver-table. Its value ranges between 1 and the value of cpqCmcTrapTableNumber " ::= { cpqCmcTrapEntry 1 } cpqCmcTrapStatus OBJECT-TYPE SYNTAX INTEGER { other(1), enabled(2), disabled(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Enable or disable trap receiver" ::= { cpqCmcTrapEntry 2 } cpqCmcTrapIPaddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "IP-address of trap-receiver" ::= { cpqCmcTrapEntry 3 } cpqCmcValueTemp1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Actual temperature value of temperature sensor 1 in deg C or deg F" ::= { cpqCmcValues 1 } cpqCmcValueTemp2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Actual temperature value of temperature sensor 2 in deg C or deg F" ::= { cpqCmcValues 2 } cpqCmcValueVoltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Actual value of power supply (voltage monitoring and fans) in V" ::= { cpqCmcValues 3 } cpqCmcValueHumidity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Actual value of humidity 0..100%" ::= { cpqCmcValues 4 } cpqCmcValueOperatingTime OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-only STATUS mandatory DESCRIPTION "Operating time CMC-unit" ::= { cpqCmcValues 5 } cpqCmcStatusTemp1 OBJECT-TYPE SYNTAX INTEGER { other(1), normal(2), warning(3), overMax(4), underMin(5), noSensor(6), error(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of temperature 1, see thresholds of temperature 1: (2) temperature normal (3) temperature exceeds warning threshold (4) temperature exceeds max. threshold (5) temperature drops under min. threshold (6) no sensor connected, not available (7) error, sensor disconnected" ::= { cpqCmcStatus 1 } cpqCmcStatusTemp2 OBJECT-TYPE SYNTAX INTEGER { other(1), normal(2), warning(3), overMax(4), underMin(5), noSensor(6), error(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of temperature 2, see thresholds of temperature 2: (2) temperature normal (3) temperature exceeds warning threshold (4) temperature exceeds max. threshold (5) temperature drops under min. threshold (6) no sensor connected, not available (7) error, sensor disconnected" ::= { cpqCmcStatus 2 } cpqCmcStatusFan1 OBJECT-TYPE SYNTAX INTEGER { other(1), autoOff(2), autoOn(3), manualOff(4), manualOn(5), smokeOff(6), doorOff(7), noFan(8), error(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of fan 1: (2) fan is switched off by temperature sensor 1 (3) fan is switched on by temperature sensor 1 (4) fan is switched off by Manual Control (cpqCmcSetFan1) (5) fan is switched on by Manual Control (cpqCmcSetFan1) (6) fan is switched off because of smoke alarm (7) fan is switched off because door is open (8) no fan (9) fan error, current monitoring" ::= { cpqCmcStatus 3 } cpqCmcStatusFan2 OBJECT-TYPE SYNTAX INTEGER { other(1), autoOff(2), autoOn(3), manualOff(4), manualOn(5), smokeOff(6), doorOff(7), noFan(8), error(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of fan 2: (2) fan is switched off by temperature sensor 2 (3) fan is switched on by temperature sensor 2 (4) fan is switched off by Manual Control (cpqCmcSetFan2) (5) fan is switched on by Manual Control (cpqCmcSetFan2) (6) fan is switched off because of smoke alarm (7) fan is switched off because door is open (8) no fan (9) fan error, current monitoring" ::= { cpqCmcStatus 4 } cpqCmcStatusVoltage OBJECT-TYPE SYNTAX INTEGER { other(1), normal(2), overMax(3), underMin(4), noVoltage(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The voltage-status, see thresholds of power supply: (2) voltage normal (3) voltage exceeds max. threshold (4) voltage drops under min. threshold (5) no power connected" ::= { cpqCmcStatus 5 } cpqCmcStatusHumidity OBJECT-TYPE SYNTAX INTEGER { other(1), normal(2), overMax(3), underMin(4), noSensor(5), error(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The humidity-status, see thresholds of humidity: (2) humidity normal (3) humidity exceeds max. threshold (4) humidity drops under min. threshold (5) no sensor connected, not available (6) error, sensor disconnected" ::= { cpqCmcStatus 6 } cpqCmcStatusInput1 OBJECT-TYPE SYNTAX INTEGER { other(1), closed(2), open(3), noSensor(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of door/sidepanel 1, closed (2), open (3) or no sensor connected (4)" ::= { cpqCmcStatus 7 } cpqCmcStatusInput2 OBJECT-TYPE SYNTAX INTEGER { other(1), closed(2), open(3), noSensor(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of door/sidepanel 2, closed (2), open (3) or no sensor connected (4)" ::= { cpqCmcStatus 8 } cpqCmcStatusInput3 OBJECT-TYPE SYNTAX INTEGER { other(1), closed(2), open(3), noSensor(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of door/sidepanel 3, closed (2), open (3) or no sensor connected (4)" ::= { cpqCmcStatus 9 } cpqCmcStatusInput4 OBJECT-TYPE SYNTAX INTEGER { other(1), closed(2), open(3), noSensor(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of door/sidepanel 4, closed (2), open (3) or no sensor connected (4)" ::= { cpqCmcStatus 10 } cpqCmcStatusLock1Lock OBJECT-TYPE SYNTAX INTEGER { other(1), locked(2), unlockedAuto(3), unlockedTime(4), unlockedSmoke(5), unlockedKey(6), unlockedPwrFail(7), unlockedBattLow(8), unlockedNetFail(9), unlockedConnFail(10), readyToLock(11), alarm(12), configError(13), notAvail(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of door locking 1 (2) Door locking-device is activated, door is locked (3) Door locking-device is not activated, door is unlocked by Network Management (4) Door locking-device is not activated for x sec, time see cpqCmcSetupLock1Time, door is unlocked by Network Management (5) Door locking-device is not activated, door is unlocked because of Smoke alarm (6) Door is unlocked from remote-signal (7) Door locking-device is not activated, door is unlocked because of Power Fail of locking device (8) Door locking-device is not activated, door is unlocked because of low Battery of locking device (9) Door locking-device is not activated, door is unlocked because of Network Fail (10)Door locking-device is not activated, door is unlocked because of connection fail, no connection locking device <-> CMC (11)Door locking-device is ready to lock, lock will be activated after doors are closed (12)Door locking-device is activated but door is not locked, alarm (13)Configuration error, association door to locking-device missing (14)Lock not installed" ::= { cpqCmcStatus 11 } cpqCmcStatusLock2Lock OBJECT-TYPE SYNTAX INTEGER { other(1), locked(2), unlockedAuto(3), unlockedTime(4), unlockedSmoke(5), unlockedKey(6), unlockedPwrFail(7), unlockedBattLow(8), unlockedNetFail(9), unlockedConnFail(10), readyToLock(11), alarm(12), configError(13), notAvail(14) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of door locking 2 (2) Door locking-device is activated, door is locked (3) Door locking-device is not activated, door is unlocked by Network Management (4) Door locking-device is not activated for x sec, time see cpqCmcSetupLock1Time, door is unlocked by Network Management (5) Door locking-device is not activated, door is unlocked because of Smoke alarm (6) Door is unlocked from remote-signal (7) Door locking-device is not activated, door is unlocked because of Power Fail of locking device (8) Door locking-device is not activated, door is unlocked because of low Battery of locking device (9) Door locking-device is not activated, door is unlocked because of Network Fail (10)Door locking-device is not activated, door is unlocked because of connection fail, no connection locking device <-> CMC (11)Door locking-device is ready to lock, lock will be activated after doors are closed (12)Door locking-device is activated but door is not locked, alarm (13)Configuration error, association door to locking-device missing (14)Lock not installed" ::= { cpqCmcStatus 12 } cpqCmcStatusSmoke OBJECT-TYPE SYNTAX INTEGER { other(1), cleared(2), present(3), noSensor(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Status smoke-sensor, OK (2), smoke detected (3) or no sensor connected (4)" ::= { cpqCmcStatus 13 } cpqCmcStatusShock OBJECT-TYPE SYNTAX INTEGER { other(1), cleared(2), present(3), noSensor(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Status Shock sensor, OK (2), shock detected (3) or no sensor connected (4)" ::= { cpqCmcStatus 14 } cpqCmcStatusAux1 OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), alarm(3), noSensor(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Status aux. digital input" ::= { cpqCmcStatus 15 } cpqCmcStatusAux2 OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), alarm(3), noSensor(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Status aux. digital input" ::= { cpqCmcStatus 16 } cpqCmcStatusAlarm1 OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), alarm(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of alarm 1, see cmpCmcsetAlarm1. This alarm can be set from the Network management system. A descriptional text for this alarm can be set in cpqCmcSetupAlarm1Description." ::= { cpqCmcStatus 17 } cpqCmcStatusAlarm2 OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), alarm(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of alarm 2, see cmpCmcsetAlarm2. This alarm can be set from the Network management system. A descriptional text for this alarm can be set in cpqCmcSetupAlarm2Description." ::= { cpqCmcStatus 18 } cpqCmcStatusLock1Dev OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), powerFail(3), lowBattery(4), replaceBatt(5), missingBatt(6), noConnect(7), notAvail(8) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of door-locking device 1 (2) OK (3) Power fail of door locking-device (4) Low Battery of door locking-device (5) Battery of door locking device needs to be replaced (6) Battery missing, insert all batteries (7) Connection CMC->door locking device lost (8) Lock not installed" ::= { cpqCmcStatus 19 } cpqCmcStatusLock2Dev OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), powerFail(3), lowBattery(4), replaceBatt(5), missingBatt(6), noConnect(7), notAvail(8) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of door-locking device 2 (2) OK (3) Power fail of door locking-device (4) Low Battery of door locking-device (5) Battery of door locking device needs to be replaced (6) Battery missing, insert all batteries (6) Connection CMC->door locking device lost (7) Lock not installed" ::= { cpqCmcStatus 20 } cpqCmcStatusAccess OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-only STATUS mandatory DESCRIPTION "Status access, for future use" ::= { cpqCmcControl 1 } cpqCmcSetLock1Lock OBJECT-TYPE SYNTAX INTEGER { other(1), lockDoor(2), openDoorTime(3), openDoor(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Set door locking device 1, see table With this command the management-station can set the conditions for the door locking device (2) Door will be locked (3) Door will be unlocked for a defined time, time can be changed, see cpqCmcSetupLock1Time (4) Door is generally unlocked Locking and unlocking with this command can not be enabled or disabled with cpqCmcSetLock1Key-command" ::= { cpqCmcControl 2 } cpqCmcSetLock1Key OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enableBoth(3), enableKeypad(4), enableRemoteInput(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Enable or disable unlocking of the rack-door with external components like keypad or remote input. With this command the management station can set the conditions for unlocking the door: (2) unlocking is disabled, no unlocking with keypad or remote input (3) unlocking with keypad or remote signal (both) is enabled (4) unlocking with keypad (only) is enabled (5) unlocking with remote input (only) is enabled Unlocking door with the cpqCmcSetLock1Lock-command does not depend on this variable" ::= { cpqCmcControl 3 } cpqCmcSetLock2Lock OBJECT-TYPE SYNTAX INTEGER { other(1), lockDoor(2), openDoorTime(3), openDoor(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Set door locking device 2, see table With this command the management-station can set the conditions for the door locking device (2) Door will be locked (3) Door will be unlocked for a defined time, time can be changed, see cpqCmcSetupLock2Time (4) Door is generally unlocked Locking and unlocking with this command can not be enabled or disabled with cpqCmcSetLock2Key-command" ::= { cpqCmcControl 4 } cpqCmcSetLock2Key OBJECT-TYPE SYNTAX INTEGER { other(1), disable(2), enableBoth(3), enableKeypad(4), enableRemoteInput(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Enable or disable unlocking of the rack-door with external components like keypad or remote input. With this command the management-station can set the conditions for unlocking the door: (2) unlocking is disabled, no unlocking with keypad or remote input (3) unlocking with keypad or remote signal (both) is enabled (4) unlocking with keypad (only) is enabled (5) unlocking with remote input (only) is enabled Unlocking door with the cpqCmcSetDoor2-command does not depend on this variable" ::= { cpqCmcControl 5 } cpqCmcSetMessage OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-only STATUS mandatory DESCRIPTION "Set message to CMC, for future use" ::= { cpqCmcControl 6 } cpqCmcSetAlarm1 OBJECT-TYPE SYNTAX INTEGER { other(1), clearAlarm(2), setAlarm(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Is used to set an alarm in the CMC from the management-station. With this command the management-station can i.e. switch on an alarm-relay or the AudibleAlarm of the CMC. Can be used for alert-handling" ::= { cpqCmcControl 7 } cpqCmcSetAlarm2 OBJECT-TYPE SYNTAX INTEGER { other(1), clearAlarm(2), setAlarm(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Is used to set an alarm in the CMC from the management-station. With this command the management-station can i.e. switch on an alarm-relay or the AudibleAlarm of the CMC. Can be used for alert-handling" ::= { cpqCmcControl 8 } cpqCmcSetFan1 OBJECT-TYPE SYNTAX INTEGER { other(1), auto(2), on(3), off(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Is used for run and stop control of fan1. (2) fan will run and stop according to temperature of sensor 1 and threshold of fan1 (3) fan will run independent of temperature and threshold (4) fan will stop independent of temperature and threshold (3) and (4) can be used for alert handling." ::= { cpqCmcControl 9 } cpqCmcSetFan2 OBJECT-TYPE SYNTAX INTEGER { other(1), auto(2), on(3), off(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Is used for run and stop control of fan2. (2) fan will run and stop according to temperature of sensor 2 and threshold of fan2 (3) fan will run independent of temperature and threshold (4) fan will stop independent of temperature and threshold (3) and (4) can be used for alert handling" ::= { cpqCmcControl 10 } cpqCmcSetQuitRelay1 OBJECT-TYPE SYNTAX INTEGER { other(1), switched(2), notSwitched(3), quit(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Status and quit of alarm relay 1. (2) relay is switched because of an alarm (3) relay is not switched, no alarm (4) (set) will quit relay 1 in case of alarm" ::= { cpqCmcControl 11 } cpqCmcSetQuitRelay2 OBJECT-TYPE SYNTAX INTEGER { other(1), switched(2), notSwitched(3), quit(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Status and quit of alarm relay 2. (2) relay is switched because of an alarm (3) relay is not switched, no alarm (4) (set) will quit relay 2 in case of alarm" ::= { cpqCmcControl 12 } cpqCmcLogsNumber OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Number of Log-entries" ::= { cpqCmcLog 1 } cpqCmcLogTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqCmcLogEntry ACCESS read-only STATUS mandatory DESCRIPTION "Log-table" ::= { cpqCmcLog 2 } cpqCmcLogEntry OBJECT-TYPE SYNTAX CpqCmcLogEntry ACCESS read-only STATUS mandatory DESCRIPTION "Log-table entries" INDEX { cpqCmcLogIndex } ::= { cpqCmcLogTable 1 } cpqCmcLogEntry ::= SEQUENCE { cpqCmcLogIndex INTEGER, cpqCmcLogDate DisplayString, cpqCmcLogTime DisplayString, cpqCmcLogText DisplayString, cpqCmcLogClass DisplayString } cpqCmcLogIndex OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-only STATUS mandatory DESCRIPTION "Index for the Log-table. Its value ranges between 1 and the value of cpqCmcLogsNumber " ::= { cpqCmcLogEntry 1 } cpqCmcLogDate OBJECT-TYPE SYNTAX DisplayString (SIZE(0..11)) ACCESS read-only STATUS mandatory DESCRIPTION "Date of log information. " ::= { cpqCmcLogEntry 2 } cpqCmcLogTime OBJECT-TYPE SYNTAX DisplayString (SIZE(0..11)) ACCESS read-only STATUS mandatory DESCRIPTION "Time of log information. " ::= { cpqCmcLogEntry 3 } cpqCmcLogText OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-only STATUS mandatory DESCRIPTION "Log information. " ::= { cpqCmcLogEntry 4 } cpqCmcLogClass OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-only STATUS mandatory DESCRIPTION "Status of log information. " ::= { cpqCmcLogEntry 5 } cpqCmcalarm2 TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusAlarm2 } --#SUMMARY "Location: %s, Message: %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "NMSalarm (153018)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "Alarm 2, set from Network management" ::= 153018 cpqCmcalarmTemp1 TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusTemp1 } --#SUMMARY "Location: %s, Message: Rack temp sensor 1 %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Temperaturealarm (153001)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "The temperature at rack sensor 1 is outside the specified threshold. Action: Check the air handling system for the rack and refer to Trap Details for more information." ::= 153001 cpqCmcalarm1 TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusAlarm1 } --#SUMMARY "Location: %s, Message: %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "NMSalarm (153017)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "Alarm 1, set from Network management" ::= 153017 cpqCmcalarmLock1Dev TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusLock1Dev } --#SUMMARY "Location: %s, Status: door lock device #1 %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Doorlockingalarm of device (153019)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "The rack door locking device #1 has failed. Action: Check the device lock cable or failed battery and refer to Trap Details for more information." ::= 153019 cpqCmcalarmFan2 TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusFan2 } --#SUMMARY "Location: %s, Rack fan 2 status: %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Fanalarm (153004)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "The status of Fan 2 has changed. Action: Refer to Trap Details for more information." ::= 153004 cpqCmcalarmFan1 TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusFan1 } --#SUMMARY "Location: %s, Rack fan 1 status: %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Fanalarm (153003)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "The status of Fan 1 has changed. Action: Refer to Trap Details for more information." ::= 153003 cpqCmcalarmVoltage TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusVoltage } --#SUMMARY "Location: %s, Message: Rack supply voltage %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Voltagealarm (153005)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "The AC voltage of the rack is outside the specified threshold. Action: Check the incoming power source and ensure all cables are inserted correctly." ::= 153005 cpqCmcalarmLock2Dev TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusLock2Dev } --#SUMMARY "Location: %s, Status: door lock device #2 %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Doorlockingalarm of device (153020)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "The rack door locking device #2 has failed. Action: Check the device lock cable or failed battery and refer to Trap Details for more information." ::= 153020 cpqCmcalarmShock TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusShock } --#SUMMARY "Location: %s, Message: Rack shock detector shock: %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Shockalarm (153014)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "The rack shock detector has detected a vibration to the rack. Action: Investigate rack." ::= 153014 cpqCmcalarmLock2 TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusLock2Lock } --#SUMMARY "Location: %s, Message: Rack lock #1 %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Doorlockingalarm (153012)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "Rack door lock #2 alarm. Action: Ensure the door is completely closed and check for unauthorized intrusion and refer to Trap Details for more information." ::= 153012 cpqCmcalarmLock1 TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusLock1Lock } --#SUMMARY "Location: %s, Message: Rack lock #1 %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Doorlockingalarm (153011)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "Rack door lock #1 alarm. Action: Ensure the door is completely closed and check for unauthorized intrusion and refer to Trap Details for more information." ::= 153011 cpqCmcalarmHumidity TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusHumidity } --#SUMMARY "Location: %s, Message: %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Humidityalarm (153006)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "The humidity of the rack is outside the specified threshold. Action: Check the air handling system for the rack and refer to Trap Details for more information." ::= 153006 cpqCmcSetupChanged TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation } --#SUMMARY "Location: %s, Name: %s, contact %s" --#ARGUMENTS {3,2,1} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: #" --#TYPE "Setup has changed (153100)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "Setup of CMC has changed." ::= 153100 cpqCmcalarmInput4 TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusInput4 } --#SUMMARY "Location: %s, Message: Rack access point 4 %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MINOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Door/sidepanelalarm (153010)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "The door or sidepanel of the rack has been opened (access point #4). Action: Check for unauthorized intrusion and refer to Trap Details for more information." ::= 153010 cpqCmcalarmInput3 TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusInput3 } --#SUMMARY "Location: %s, Message: Rack access point 3 %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MINOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Door/sidepanelalarm (153009)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "The door or sidepanel of the rack has been opened (access point #3). Action: Check for unauthorized intrusion and refer to Trap Details for more information." ::= 153009 cpqCmcalarmInput2 TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusInput2 } --#SUMMARY "Location: %s, Message: Rack access point 2 %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MINOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Door/sidepanelalarm (153008)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "The door or sidepanel of the rack has been opened (access point #2). Action: Check for unauthorized intrusion and refer to Trap Details for more information." ::= 153008 cpqCmcalarmInput1 TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusInput1 } --#SUMMARY "Location: %s, Message: Rack access point 1 %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MINOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Door/sidepanelalarm (153007)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "The door or sidepanel of the rack has been opened (access point #1). Action: Check for unauthorized intrusion and refer to Trap Details for more information." ::= 153007 cpqCmcalarmSmoke TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusSmoke } --#SUMMARY "Location: %s, Message: Rack smoke detector smoke: %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Smokealarm (153013)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "The rack smoke detector has detected smoke. Action: Investigate rack for an over temperature condition and refer to Trap Details for more information." ::= 153013 cpqCmcalarmAux2 TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusAux2 } --#SUMMARY "Location: %s, Message: aux input #2 %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Auxalarm (153016)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "The rack auxiliary alarm input #2 has been triggered." ::= 153016 cpqCmcalarmAux1 TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusAux1 } --#SUMMARY "Location: %s, Message: aux input #1 %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Auxalarm (153015)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "The rack auxiliary alarm input #1 has been triggered." ::= 153015 cpqCmcalarmTemp2 TRAP-TYPE ENTERPRISE cpqCmc VARIABLES { sysDescr, sysContact, sysName, sysLocation, cpqCmcStatusTemp2 } --#SUMMARY "Location: %s, Message: Rack temp sensor 2 %s from: %s, contact %s" --#ARGUMENTS {3,4,2,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#MSG_FORMATTER "$V1V#Description: # $V2V#Contact: # $V4V#Location: # $V5V#Status: #" --#TYPE "Temperaturealarm (153002)" --#ENABLE true --#CATEGORY "Proliant Remote Management Events" DESCRIPTION "The temperature at rack sensor 2 is outside the specified threshold. Action: Check the air handling system for the rack and refer to Trap Details for more information." ::= 153002 END