RC-PORT-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32 FROM SNMPv2-SMI TruthValue, DisplayString, MacAddress, RowStatus, TimeInterval FROM SNMPv2-TC InterfaceIndex FROM IF-MIB rcPort, rcChassis, rcTest, rcStat, PortSet, EnableValue FROM RAPID-CITY; rcPortMib MODULE-IDENTITY LAST-UPDATED "200604190000Z" ORGANIZATION "Bay Networks, Rapid-City Group" CONTACT-INFO "Yu-Ten Lee Postal: Nortel Networks, Inc. 4465 Great America Parkway Santa Clara, CA 95052-8185 Tel: 408-495-2560 Fax: 408-495-6680 E-mail: ylee@nortelnetworks.com" DESCRIPTION "Enterprise MIB for the Accelar product family." REVISION "200604190000Z" -- 19 Apr 2006 DESCRIPTION "Version 36: Added rcPortSmartAutoNegotiate" REVISION "200602100000Z" -- 10 Feb 2006 DESCRIPTION "Version 35: Added objects rcPortLacpEntry 7-10" REVISION "200602080000Z" -- 08 Feb 2006 DESCRIPTION "Version 34: Added to rcPortType" REVISION "200601180000Z" -- 18 Jan 2006 DESCRIPTION "Version 33: Updated rcPortPoeMainPseExtnDeviceDetectType" REVISION "200511150000Z" -- 15 Nov 2005 DESCRIPTION "Version 32: Added 3 objects to rcPortTable." REVISION "200510130000Z" -- 13 Oct 2005 DESCRIPTION "Version 31: Added rcPortTrustDscp. Updated the defval on rcPortRemoteMirroringEtherType" REVISION "200508250000Z" -- 25 Aug 2005 DESCRIPTION "Version 30: Removed duplicate leaf rcPortVLacpPortState" REVISION "200507200000Z" -- 20 July 2005 DESCRIPTION "Version 29: Added leaf rcPortVLacpPortState" REVISION "200507150000Z" -- 15 July 2005 DESCRIPTION "Version 28: Added rc1000BaseTXPOE to rcPortType" REVISION "200506220000Z" -- 22 June 2005 DESCRIPTION "Version 27: Added rcPortFlushFdbTable" REVISION "200506100000Z" -- 10 June 2005 DESCRIPTION "Version 26: chaned rcPortName length to 225" REVISION "200506070000Z" -- 7 June 2005 DESCRIPTION "Version 25: added attribute rcPortQinqEtherType to rcPortTable" REVISION "200506010000Z" -- 1 June 2005 DESCRIPTION "Version 24: added objects for BPDU filtering" REVISION "200504150000Z" -- 15 Apr 2005 DESCRIPTION "Version 23: added new port types for 10 Gb (58-62) to rcPortType" REVISION "200502160000Z" -- 16 Feb 2005 DESCRIPTION "Version 22: changed range of rcPortPcapFilterList" REVISION "200502040000Z" -- 04 Feb 2005 DESCRIPTION "Version 21: Added rcPortMgmtLinkTable" REVISION "200501140000Z" -- 14 Jan 2005 DESCRIPTION "Version 20: Added support for 10Gig links." REVISION "200412150000Z" -- 15 December 2004 DESCRIPTION "Version 19: Added rcPortEgressRateLimit and rcPortEgressRateLimitState to rcPortEntry" REVISION "200412090000Z" -- 09 December 2004 DESCRIPTION "Version 18: Fix typos and clean up revision history" REVISION "200411240000Z" -- 24 November 2004 DESCRIPTION "Version 17: Re-submitting previous request as changes are not reflected" REVISION "200411040000Z" -- 04 November 2004 DESCRIPTION "Version 16: Added rcPortExtCplimitConf, rcPortExtCplimitUtilRate under rcPortTable" REVISION "200410110000Z" -- 11 October 2004 DESCRIPTION "Version 15: rcPortType conflict: rc10GbNone is now (56). Remove rcPort8021POverrideEnable (rcPortEntry 65) as we will be using rcPortIeee8021POverrideEnable from PP8300." REVISION "200409300001Z" -- 30 September 2004 DESCRIPTION "Version 14: Add range for rcPortVlacpSessionIfIndex' & rcPortVlacpSessionSesNumber." REVISION "200409300000Z" -- 30 September 2004 DESCRIPTION "Version 13: Add rcGbicBx to rcPortType" REVISION "200409290000Z" -- 29 September 2004 DESCRIPTION "Version 12: Add range for rcPortLacpFastPeriodicTime/SlowPeriodicTime, rcPortVLacpFastPeriodicTime/SlowPeriodicTime " REVISION "200409280000Z" -- 28 September 2004 DESCRIPTION "Version 11: Add missing REVISION cause. " REVISION "200409220000Z" -- 22 September 2004 DESCRIPTION "Version 10: Change rc100BaseTXPOL to rc100BaseTXPOE. " REVISION "200409210000Z" -- 21 September 2004 DESCRIPTION "Version 10: Added rcPort8021POverrideEnable attribute by Alka Malik. " REVISION "200409080000Z" -- 08 September 2004 DESCRIPTION "Version 9: Added rcPortAutoRecoverPort to RcPortEntry " REVISION "200409010000Z" -- 01 Sept 2004 DESCRIPTION "Version 8: Added rcPortPoeMainPseExtnPwrLimit to rcPortPoeMainPseExtnTable" REVISION "200408030000Z" -- 03 August 2004 DESCRIPTION "Version 7: Added rcPortVlacpSessionTable by Amit Singh. Also, there was a mismatch in MRT submission for rcPortPoe (rcPort 7 versus rcPort 3 (correct)." REVISION "200407230000Z" -- 23 July 2004 DESCRIPTION "Version 6: Added rcPortVLacpPortState to rcPortVLacpTable, move rcPortVLacpDualHomingEnable to .10 (it was erroneously defined as .9 when it was added)." REVISION "200407220000Z" -- 22 July 2004 DESCRIPTION "Version 5: Added rcPortAutoNegAd and rcPortAutoNegAdCapability to rcPortTable" REVISION "200407070000Z" -- 7 July 2004 DESCRIPTION "Version 4: Added rcPortVLacpDualHomingEnable to rcPortVLacpTable" ::= { rcPort 0 } -- Port Table rcPortTable OBJECT-TYPE SYNTAX SEQUENCE OF RcPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port table" ::= { rcPort 1 } rcPortEntry OBJECT-TYPE SYNTAX RcPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing info. for a particular port" INDEX { rcPortIndex } ::= { rcPortTable 1 } RcPortEntry ::= SEQUENCE { rcPortIndex InterfaceIndex, rcPortType INTEGER, rcPortConnectorType INTEGER, rcPortPerformRouting TruthValue, rcPortHighPriority TruthValue, rcPortAction INTEGER, rcPortResult INTEGER, rcPortPrimaryConnector INTEGER, rcPortActiveConnector INTEGER, rcPortBackupConnectorStatus INTEGER, rcPortAutoNegotiate TruthValue, rcPortAdminDuplex INTEGER, rcPortOperDuplex INTEGER, rcPortAdminSpeed INTEGER, rcPortOperSpeed Integer32, rcPortMltId Integer32, rcPortLocked TruthValue, rcPortAutoNegotiationSupported TruthValue, rcPortSingleRoutablePort TruthValue, rcPortUnknownMacDiscard TruthValue, rcPortNumStateTransition Counter32, rcPortAllowOversizeFrame TruthValue, rcPortUserPriority INTEGER, rcPortQosLevel INTEGER, rcPortDiffServEnable TruthValue, rcPortDiffServType INTEGER, rcPortDiffServIeee8021POverrideEnable TruthValue, rcPortVendorDescr DisplayString, rcPortName DisplayString, rcPortOctapidId Integer32, rcPortWan INTEGER, rcPortTransport INTEGER, rcPortMultimediaFilterEnable TruthValue, rcPortMultimediaDevSelection DisplayString, rcPortServiceType INTEGER, rcPortMode INTEGER, rcPortAdminRouting EnableValue, rcPortOperRouting EnableValue, rcPortPid Integer32, rcPortIeee8021POverrideEnable TruthValue, rcPortShaperEnable TruthValue, rcPortShaperMaxRate INTEGER, rcPortShaperBurstSize INTEGER, rcPortCpLimitShutDown TruthValue, rcPortHighSecureEnable TruthValue, rcPortTlsPriorityOverride EnableValue, rcPortVctAbility INTEGER, rcPortVctAdminStatus EnableValue, rcPortMrouteStrLimit INTEGER, rcPortMrouteStrTimerCheck INTEGER, rcPortMrouteStrLimitEnable TruthValue, rcPortUpdateDynamicMacQosLevel EnableValue, rcPortVplsDualHoming INTEGER, rcPortVplsMgmtVlan TruthValue, rcPortTlsManagedBySp TruthValue, rcPortAutoNegAd BITS, rcPortAutoNegAdCapability BITS, rcPortAutoRecoverPort TruthValue, rcPortExtCplimitConf INTEGER, rcPortExtCplimitUtilRate INTEGER, rcPortEgressRateLimit INTEGER, rcPortEgressRateLimitState EnableValue, rcPortBpduFilteringTimerCount TimeInterval, rcPortBpduFilteringTimeout TimeInterval, rcPortBpduFilteringAdminEnabled TruthValue, rcPortBpduFilteringOperEnabled TruthValue, rcPortQinqEtherType INTEGER, rcPortTrustDscp TruthValue, rcPortCpLimitEnable EnableValue, rcPortCpMulticastLimit INTEGER, rcPortCpBroadcastLimit INTEGER, rcPortSmartAutoNegotiate TruthValue } rcPortIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "An index value that uniquely identifies a port. This value is similar to ifIndex in MIB2." ::= { rcPortEntry 1 } rcPortType OBJECT-TYPE SYNTAX INTEGER { other(0), -- no port installed rc100BaseTX(1), -- (cat 5) rc100BaseT2(2), -- (cat 3) rc100BaseF(3), -- (100 mbps fiber) rc1000BaseF(4), -- (1000 mbps fiber) rc1000BaseDualF(5), -- (fiber - dual connector) rc10BaseF(6), -- (10 mbps fiber) rcPosMMF(7), -- (multi mode fiber) rcPosSMF(8), -- (single mode fiber) rcAtm(9), -- (oc3, oc12, ds3, e3) rcGbicLx(10), -- (gigabit long haul) rcGbicSx(11), -- (gigabit short haul) rcGbicXd(12), -- (gigabit extended distance) rcGbicCu(13), -- (gigabit copper) rcGbicOther(14), -- (gigabit other) rcOc3cSM(15), -- (OC-3c SM) rcOc3cMM(16), -- (OC-3c MM) rcOc3cCOPPER(17), -- (OC-3c COPPER) rcOc12cSM(18), -- (OC-12c SM) rcOc12cMM(19), -- (OC-12c MM) rcDs3(20), -- (Ds3) rcE3(21), -- (E3) rcGbicNone(22), -- (Gbic card feature) rc1000BaseT(23), -- (1000 base copper) rcGbicZx(24), -- (gigabit very extended distance) rcOc3cAtmSM(25), -- (Atm OC-3c SM) rcOc3cAtmMM(26), -- (Atm OC-3c MM) rcOc12cAtmSM(27), -- (Atm OC-12c SM) rcOc12cAtmMM(28), -- (Atm OC-12c MM) rcOc3cPosSM(29), -- (Pos OC-3c SM) rcOc3cPosMM(30), -- (Pos OC-3c MM) rcOc12cPosSM(31), -- (Pos OC-12c SM) rcOc12cPosMM(32), -- (Pos OC-12c MM) rcGbic1470(33), -- (gigabit wavelength 1470) rcGbic1490(34), -- (gigabit wavelength 1490) rcGbic1510(35), -- (gigabit wavelength 1510) rcGbic1530(36), -- (gigabit wavelength 1530) rcGbic1550(37), -- (gigabit wavelength 1550) rcGbic1570(38), -- (gigabit wavelength 1570) rcGbic1590(39), -- (gigabit wavelength 1590) rcGbic1610(40), -- (gigabit wavelength 1610) rcRmon(41), -- (1000 base TProbe) rcGbic1470APD(42), -- (gigabit wavelength 1470-APD) rcGbic1490APD(43), -- (gigabit wavelength 1490-APD) rcGbic1510APD(44), -- (gigabit wavelength 1510-APD) rcGbic1530APD(45), -- (gigabit wavelength 1530-APD) rcGbic1550APD(46), -- (gigabit wavelength 1550-APD) rcGbic1570APD(47), -- (gigabit wavelength 1570-APD) rcGbic1590APD(48), -- (gigabit wavelength 1590-APD) rcGbic1610APD(49), -- (gigabit wavelength 1610-APD) rc10GbLW(50), -- (10 Gig Ethernet LW) rc10GbLR(51), -- (10 Gig Ethernet LR) rcLogicalServerPort(52), -- opm Prism used as a server for MPLS rc1000BaseTX(53), -- (triple speed) rc100BaseTXPOE(54), -- (double speed with POE support) rcGbicBx(55), -- (gigabit medium haul) rc10GbNone(56), -- (10 Gig Feature) rc1000XFP(57), -- 10Gig XFP Gbic rc10GbSR(58), -- (10 Gig SR Ethernet) rc10GbSW(59), -- (10 Gib SW wavelength 850nm and sonet) rc10GbER(60), -- (10 Gig ER wavelen 1550nm) rc10GbEW(61), -- (10 Gig EW) rc10GbOther(62), -- (10 Gig Ethernet other) rc1000BaseTXPOE(63), -- (triple speed with POE support) rc10GbZR(64), -- (10G Python XFP, LAN) rc10GbZW(65) -- (10G Python XFP, WAN) } MAX-ACCESS read-only STATUS current DESCRIPTION "Port type" ::= { rcPortEntry 2 } rcPortConnectorType OBJECT-TYPE SYNTAX INTEGER { nonRedundant(1), -- non-redundant connector type redundant(2) -- redundant connector type } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of connector installed on this port." DEFVAL { nonRedundant } ::= { rcPortEntry 3 } rcPortPerformRouting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Indicate whether this port should perform routing" DEFVAL { false } ::= { rcPortEntry 4 } rcPortHighPriority OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Indicate whether this port should be treated with high priority" DEFVAL { false } ::= { rcPortEntry 5 } rcPortAction OBJECT-TYPE SYNTAX INTEGER { none(1), -- none of the following flushMacFdb(2), -- flush MAC forwarding table flushArp(3), -- flush ARP table flushIp(4), -- flush IP route table flushAll(5), -- flush all tables triggerRipUpdate(6), -- manually trigger rip update clearLoopDetectAlarm(7) -- manually enable the port on all the disabled vlans } MAX-ACCESS read-write STATUS current DESCRIPTION "Port related actions." DEFVAL { none } ::= { rcPortEntry 6 } rcPortResult OBJECT-TYPE SYNTAX INTEGER { none(1), -- none of the following inProgress(2), -- in progress success(3), -- success fail(4) -- failure } MAX-ACCESS read-only STATUS current DESCRIPTION "Result from the last Vlan action." DEFVAL { none } ::= { rcPortEntry 7 } rcPortPrimaryConnector OBJECT-TYPE SYNTAX INTEGER { left(1), -- left side connector right(2), -- right side connector other(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "For ports configured with redundant connectors, this value is used to indicate which connector should be used as the 'active' connector on this port the next time the port is placed into the ifAdminStatus=Up." DEFVAL { left } ::= { rcPortEntry 8 } rcPortActiveConnector OBJECT-TYPE SYNTAX INTEGER { left(1), -- left side connector right(2), -- right side connector other(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "For ports configured with redundant connectors, this value is used to indicate which connector is currently the active one. Only one connector can be active an anytime." DEFVAL { left } ::= { rcPortEntry 9 } rcPortBackupConnectorStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- link Up down(2), -- link Down other(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate the status of the link attached to the back-up (non-active) connector." ::= { rcPortEntry 10 } rcPortAutoNegotiate OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicate whether this port enabled for auto negotiations or not." DEFVAL { true } ::= { rcPortEntry 11 } rcPortAdminDuplex OBJECT-TYPE SYNTAX INTEGER { half(1), -- half duplex full(2) -- full duplex } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the port duplex type " DEFVAL { half } ::= { rcPortEntry 12 } rcPortOperDuplex OBJECT-TYPE SYNTAX INTEGER { half(1), -- half duplex full(2) -- full duplex } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate this port's current duplex value." ::= { rcPortEntry 13 } rcPortAdminSpeed OBJECT-TYPE SYNTAX INTEGER { none(0), mbps10(1), -- 10Mb/s mbps100(2), -- 100Mb/s mbps1000(3), -- 1000Mb/s mbps10000(4) -- 10Gb/s } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicate this port's speed." DEFVAL { mbps10 } ::= { rcPortEntry 14 } rcPortOperSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate this port's current speed value." ::= { rcPortEntry 15 } rcPortMltId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate which multi-link trunk (MLT) this port is assigned to. If this port is not associated with any MLT, this value will be set to zero(0)." DEFVAL { 0 } ::= { rcPortEntry 16 } rcPortLocked OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate whether this port is locked." DEFVAL { false } ::= { rcPortEntry 17 } rcPortAutoNegotiationSupported OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate whether this port can support auto-negotiation." DEFVAL { false } ::= { rcPortEntry 18 } rcPortSingleRoutablePort OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate whether this port is a single routable port. If this value is true, the port functions like a traditional router port." DEFVAL { false } ::= { rcPortEntry 19 } rcPortUnknownMacDiscard OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "If rcUnknownMacDiscard is set to True, then a packet with an unknown source MAC address is dropped on that port, and other ports then will discard any packets with this MAC address in the destination field. For example, suppose 11:22:33:44:55:66 is an unknown source MAC, packets with source MAC 11:22:33:44:55 coming from this port is discarded, further more, packets with destination MAC 11:22:33:44:55:66 coming from other ports are also discarded, unless this address is later learned on another port or the restriction ages out." DEFVAL { false } ::= { rcPortEntry 20 } rcPortNumStateTransition OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "# state transitions." ::= { rcPortEntry 21 } rcPortUserPriority OBJECT-TYPE SYNTAX INTEGER { level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "User priority level." DEFVAL { level7 } ::= { rcPortEntry 22 } rcPortAllowOversizeFrame OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Used to specify whether over-size frames should be processed or dropped." ::= { rcPortEntry 23 } rcPortQosLevel OBJECT-TYPE SYNTAX INTEGER { level0(0), level1(1), level2(2), level3(3), level4(4), level5(5), level6(6), level7(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to specify the Qos level packets, carried on this port, should be processed with." DEFVAL { level1 } ::= { rcPortEntry 30 } rcPortDiffServEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable/disable the Differentiated Service feature on this port." DEFVAL { false } ::= { rcPortEntry 31 } rcPortDiffServType OBJECT-TYPE SYNTAX INTEGER { none(0), access(1), core(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to specify the Differentiated Service type for this port." DEFVAL { access } ::= { rcPortEntry 32 } rcPortDiffServIeee8021POverrideEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Used to enable/disable the Differentiated Service IEEE 802.1P over-ride feature." DEFVAL { false } ::= { rcPortEntry 33 } rcPortVendorDescr OBJECT-TYPE SYNTAX DisplayString (SIZE(16)) MAX-ACCESS read-only STATUS current DESCRIPTION "Used to show the name of the vendor of this port's connector. Only applicable to ports on a GBIC cards." ::= { rcPortEntry 34 } rcPortName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This port's name." ::= { rcPortEntry 35 } rcPortOctapidId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The octapid id of the mirrored port." ::= { rcPortEntry 36 } rcPortWan OBJECT-TYPE SYNTAX INTEGER { none(0), -- Not Applicable for non-10GE interface wan(1), lan(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicatie this port's current WAN/LAN mode. Valid for 10 GE only" DEFVAL { wan } ::= { rcPortEntry 37 } rcPortTransport OBJECT-TYPE SYNTAX INTEGER { none(0), -- N/A for non-10GE WAN interface sonet(1), sdh(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicatie this port's current tranport layer. Valid for 10 GE only" DEFVAL { sonet } ::= { rcPortEntry 38 } rcPortMultimediaFilterEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable/disable the Telephony device selected on this port" DEFVAL { false } ::= { rcPortEntry 39 } rcPortMultimediaDevSelection OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Used to set/get the selected Multimedia & Telephony Devices on this port. The String is the name of the device in the rcIpFilterMediaDevTable" ::= { rcPortEntry 40 } rcPortServiceType OBJECT-TYPE SYNTAX INTEGER { none (0), l2uni (1), vpls (2), ip (3), serverl2uni (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the port functionality. 12uni is used to configure the port to be part of Martini service, tls is used to configure the port to be part of Any2Any VPN service and ip is used to perform the IP routing and mpls if enabled." ::= { rcPortEntry 41 } rcPortMode OBJECT-TYPE SYNTAX INTEGER { none (0), transparent (1), switched (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The port mode for l2uni service type.If the port is configured for l2uni service type, then the mode can be transparent or switched." DEFVAL { none } ::= { rcPortEntry 42 } rcPortAdminRouting OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicate whether the port is routable." DEFVAL { enable } ::= { rcPortEntry 43 } rcPortOperRouting OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the port whether is routable." ::= { rcPortEntry 44 } rcPortPid OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The pid of the mirrored port." ::= { rcPortEntry 45 } rcPortIeee8021POverrideEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable/disable IEEE 802.1P override. If it is enabled, 802.1p vlaue from a tagged frame may not honor." DEFVAL { false } ::= { rcPortEntry 46 } rcPortShaperEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable/disable shaper on the port." DEFVAL { false } ::= { rcPortEntry 47 } rcPortShaperMaxRate OBJECT-TYPE SYNTAX INTEGER (1..10000) MAX-ACCESS read-write STATUS current DESCRIPTION "Shaping rate in mega bits per second. Note that actual shaping rate might be different from the configured rate due to the rate granularity of the shaper." DEFVAL { 10 } ::= { rcPortEntry 48 } rcPortShaperBurstSize OBJECT-TYPE SYNTAX INTEGER(4..16000) MAX-ACCESS read-write STATUS current DESCRIPTION "Burst size in kilo bytes per second. Note that actual burst size might be different from the configured size due to the granularity of the shaper." DEFVAL { 4 } ::= { rcPortEntry 49 } rcPortCpLimitShutDown OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "A TRUE value indicates if CP Limit shut down the interface." ::= { rcPortEntry 50 } rcPortHighSecureEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable high secure." ::= { rcPortEntry 51 } rcPortTlsPriorityOverride OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable tls port priority override feature." DEFVAL { disable } ::= { rcPortEntry 52 } rcPortVctAbility OBJECT-TYPE SYNTAX INTEGER { vctNotCapable(1), vctCapable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "If this object is TRUE, then the specified port is hardware-capable of doing the VCT test, if the rcPortAdminStatus is also true. If this object is FALSE, then the hardware cannot do the VCT test regardless of the setting of the rcPortAdminStatus." ::= { rcPortEntry 53 } rcPortVctAdminStatus OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "Admin status for port VCT test. If this object is set to TRUE, then the VCT test can be performed. If it is set to FALSE, then the test cannot be performed, even if the port hardware is capable of doing it. If this variable si read, then the value returned is what was previously written." ::= { rcPortEntry 54 } rcPortMrouteStrLimit OBJECT-TYPE SYNTAX INTEGER (1..32768) MAX-ACCESS read-write STATUS current DESCRIPTION "maximum number of multicast streams that are allowed to ingress to CPU through this port." DEFVAL { 1984 } ::= { rcPortEntry 55 } rcPortMrouteStrTimerCheck OBJECT-TYPE SYNTAX INTEGER (1..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "sampling period to check number of multicast streams that has ingressed CPU through this port." DEFVAL { 10 } ::= { rcPortEntry 56 } rcPortMrouteStrLimitEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "enable or disable mroute stream limit on port." DEFVAL { false } ::= { rcPortEntry 57 } rcPortUpdateDynamicMacQosLevel OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "It is used to indicate whether to update qos level for dynamic learned mac add resses associated with a port-based vlan when port qos level changes. If it is set to TRUE, qos level for all dynamic learned mac addresses will be changed upon changing port qos level. If it is set to DISABLE, once a mac address is learned, qos level will not updated when port qos level changes." DEFVAL { disable } ::= { rcPortEntry 58 } rcPortVplsDualHoming OBJECT-TYPE SYNTAX INTEGER { disable (0), firstNNI (1), secondNNI (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The VPLS dual homing is for VPLS service type only. It can be disable, firstNNI or secondNNI." DEFVAL { disable } ::= { rcPortEntry 59 } rcPortVplsMgmtVlan OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Management Vlan is configured on this port" DEFVAL { false } ::= { rcPortEntry 60 } rcPortTlsManagedBySp OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "True/False tls devices on port Managed By Service Provider." DEFVAL { false } ::= { rcPortEntry 61 } rcPortAutoNegAd OBJECT-TYPE SYNTAX BITS { advertise10Half(0), advertise10Full(1), advertise100Half(2), advertise100Full(3), advertise1000Half(4), advertise1000Full(5), advertiseMacPause(6), advertiseAsymPause(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to specify the port speed and duplex abilities to be advertised during link negotiation. bit 0 - 10 half duplex advertised bit 1 - 10 full duplex advertised bit 2 - 100 half duplex advertised bit 3 - 100 full duplex advertised bit 4 - 1000 half duplex advertised bit 5 - 1000 full duplex advertised bit 6 - Mac PAUSE frame support advertised bit 7 - Asymmetric PAUSE frame support advertised The abilities specified in this object are only used when auto-negotiation is enabled on the port. If all bits in this object are disabled, and auto-negotiation is enabled on the port, then the physical link process on the port will be disabled (if hardware supports this ability). Any change in the value of this bit map will force the PHY to restart the auto-negotiation process. This will have the same effect as physically unplugging and reattaching the cable plant attached to this port. Only capabilities present in the hardware as indicated by rcPortAutoNegAdCapability can be advertised. The default value for this object will be the value of the associated instance of rcPortAutoNegAdCapability." ::= { rcPortEntry 62 } rcPortAutoNegAdCapability OBJECT-TYPE SYNTAX BITS { advertise10Half(0), advertise10Full(1), advertise100Half(2), advertise100Full(3), advertise1000Half(4), advertise1000Full(5), advertiseMacPause(6), advertiseAsymPause(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the port speed and duplex capabilities that hardware can actually support on a port, and which may be advertised by the port using auto-negotiation. Bit 7 tells if a port supports pause frame capabilities (for full-duplex links) as a part of the advertisement. bit 0 - 10 half duplex advertisements bit 1 - 10 full duplex advertisements bit 2 - 100 half duplex advertisements bit 3 - 100 full duplex advertisements bit 4 - 1000 half duplex advertisements bit 5 - 1000 full duplex advertisements bit 6 - Mac PAUSE frame support advertisements bit 7 - Asymmetric PAUSE frame support advertisements If auto negotiation is not supported by the port hardware, then all bits will reflect a value of zero." ::= { rcPortEntry 63 } rcPortAutoRecoverPort OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "enable or disable auto recovery of port from action taken by cp-limit, link flap or loop detect features" DEFVAL { false } ::= { rcPortEntry 64 } rcPortExtCplimitConf OBJECT-TYPE SYNTAX INTEGER { none(1), softDown(2), hardDown(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the port configuration for extended CP-LIMIT" DEFVAL { none} ::= { rcPortEntry 65 } rcPortExtCplimitUtilRate OBJECT-TYPE SYNTAX INTEGER (1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Threshold for Ingress traffic utilization rate of the port for extended CP-LIMIT" DEFVAL { 50 } ::= { rcPortEntry 66 } rcPortEgressRateLimit OBJECT-TYPE SYNTAX INTEGER(1000..10000000) MAX-ACCESS read-write STATUS current DESCRIPTION "Egress Rate Limit." ::= { rcPortEntry 67 } rcPortEgressRateLimitState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable/disable shape/egress-rate-limit functionality." DEFVAL { disable } ::= { rcPortEntry 68 } rcPortBpduFilteringTimerCount OBJECT-TYPE SYNTAX TimeInterval (0..6553500) MAX-ACCESS read-only STATUS current DESCRIPTION "The remaining time the port will be disabled due to a BPDU received when BPDU filtering is enabled." ::= { rcPortEntry 69 } rcPortBpduFilteringTimeout OBJECT-TYPE SYNTAX TimeInterval (0..6553500) MAX-ACCESS read-write STATUS current DESCRIPTION "The time the port will be disabled when a BPDU is received when BPDU filtering is enabled." ::= { rcPortEntry 70 } rcPortBpduFilteringAdminEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable/disable BPDU filtering." DEFVAL { false } ::= { rcPortEntry 71 } rcPortBpduFilteringOperEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether BPDU filtering is actually enabled or disabled." ::= { rcPortEntry 72 } rcPortQinqEtherType OBJECT-TYPE SYNTAX INTEGER (1..'FFFF'h) MAX-ACCESS read-write STATUS current DESCRIPTION "The qinq ether type value. It is hex value. It should be displayed and input as Hex value. It is only be used when port is associated with QnQ service UNI. Otherwise, it would be ignored" DEFVAL { '8020'h } ::= { rcPortEntry 73 } rcPortTrustDscp OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable/disable the trusted DSCP feature. If enabled, the internal qos-level and 802.1p value are derived from the received packet's DSCP value. This MIB object is applicable to ports in 8348GTX so that higher priority IP traffic can bypass the oversubscribed cascading link." DEFVAL {false} ::= {rcPortEntry 74} rcPortCpLimitEnable OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable/disable the control packet rate limit. Specifies whether or not rate limiting is currently in operation for multicast and broadcast packets for the specified port. " DEFVAL { enable } ::= {rcPortEntry 75 } rcPortCpMulticastLimit OBJECT-TYPE SYNTAX INTEGER(1000..100000) MAX-ACCESS read-write STATUS current DESCRIPTION "Used to limit Multicast traffic on the specified port. Sets the limit in packets per second." DEFVAL { 10000 } ::= { rcPortEntry 76 } rcPortCpBroadcastLimit OBJECT-TYPE SYNTAX INTEGER(1000..100000) MAX-ACCESS read-write STATUS current DESCRIPTION "Used to limit Broadcast traffic on the specified port. Sets the limit in packets per second. " DEFVAL { 10000 } ::= { rcPortEntry 77 } rcPortSmartAutoNegotiate OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether 'smart' autonegotiation is enabled on a port (smart autonegotiation indicates that the port can sense whether its partner has autonegotiation enabled). This object, when supported, works in conjunction with rcPortAutoNegotiate. It is an inconsistentValue error to set rcPortAutoNegotiate to false(2) and this object to true(1) in the same Set request. Setting the object to true(1) will automatically change rcPortAutoNegotiate to true(1). Similarly, setting rcPortAutoNegotiate to false(2) will automatically change this object to false(2)." DEFVAL { false } ::= { rcPortEntry 78 } -- Port Pcap Table rcPortPcapTable OBJECT-TYPE SYNTAX SEQUENCE OF RcPortPcapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port pcap Table" ::= { rcPort 2 } rcPortPcapEntry OBJECT-TYPE SYNTAX RcPortPcapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing pcap info. for a particular port" INDEX { rcPortPcapIndex } ::= { rcPortPcapTable 1 } RcPortPcapEntry ::= SEQUENCE { rcPortPcapIndex InterfaceIndex, rcPortPcapEnable TruthValue, rcPortPcapMode INTEGER, rcPortPcapFilterListSize INTEGER, rcPortPcapFilterList OCTET STRING } rcPortPcapIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "An index value that uniquely identifies a port. This value is similar to ifIndex in MIB2." ::= { rcPortPcapEntry 1 } rcPortPcapEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "To enable pcap for the port" DEFVAL { false } ::= { rcPortPcapEntry 2 } rcPortPcapMode OBJECT-TYPE SYNTAX INTEGER { tx(1), rx(2), both(3), rxFilter(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Mode in which pcap is enabled" DEFVAL { rx } ::= { rcPortPcapEntry 3 } rcPortPcapFilterListSize OBJECT-TYPE SYNTAX INTEGER (0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of filter list(s) that are assigned to this port." ::= { rcPortPcapEntry 4 } rcPortPcapFilterList OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) MAX-ACCESS read-write STATUS current DESCRIPTION "Used to indicate zero or more filter lists that are associated with this port for pcap. Each filter list identifier is stored as two bytes in this array starting from offset zero. Any unused bytes should be set to zero." ::= { rcPortPcapEntry 5 } -- rcPortPoe IfIndex to Pse Index Table rcPortPoe OBJECT IDENTIFIER ::= { rcPort 3 } rcPortPoePseIndexTable OBJECT-TYPE SYNTAX SEQUENCE OF RcPortPoePseIndexEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port table" ::= { rcPortPoe 1 } rcPortPoePseIndexEntry OBJECT-TYPE SYNTAX RcPortPoePseIndexEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing info. for a particular port" INDEX { rcPortPoePseIndexIfIndex } ::= { rcPortPoePseIndexTable 1 } RcPortPoePseIndexEntry ::= SEQUENCE { rcPortPoePseIndexIfIndex InterfaceIndex, rcPortPoePseIndexGroupIndex INTEGER, rcPortPoePseIndexPortIndex INTEGER } rcPortPoePseIndexIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "An index value that uniquely identifies an interface to a PSE port device. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex." ::= { rcPortPoePseIndexEntry 1 } rcPortPoePseIndexGroupIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "An index value that uniquely identifies the group containing the port to which a power Etherenet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices." ::= { rcPortPoePseIndexEntry 2 } rcPortPoePseIndexPortIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable uniquely identifies the power Ethernet PSE port within group rcPoePseGroupIndex to which the power Ethernet PSE entry is connected." ::= { rcPortPoePseIndexEntry 3 } -- POE main Pse extn table rcPortPoeMainPseExtnTable OBJECT-TYPE SYNTAX SEQUENCE OF RcPortPoeMainPseExtnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port table" ::= { rcPortPoe 2 } rcPortPoeMainPseExtnEntry OBJECT-TYPE SYNTAX RcPortPoeMainPseExtnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing info. for a particular port" INDEX { rcPortPoeMainPseExtnGroupIndex } ::= { rcPortPoeMainPseExtnTable 1 } RcPortPoeMainPseExtnEntry ::= SEQUENCE { rcPortPoeMainPseExtnGroupIndex INTEGER, rcPortPoeMainPseExtnPwrAdmin EnableValue, rcPortPoeMainPseExtnPwrPriority INTEGER, rcPortPoeMainPseExtnDeviceDetectType INTEGER, rcPortPoeMainPseExtnPwrLimit INTEGER } rcPortPoeMainPseExtnGroupIndex OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "An index value that uniquely identifies an interface to a PSE port device. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex." ::= { rcPortPoeMainPseExtnEntry 1 } rcPortPoeMainPseExtnPwrAdmin OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "An index value that uniquely identifies the group containing the port to which a power Etherenet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for as identified by the same value of ifIndex." DEFVAL { disable } ::= { rcPortPoeMainPseExtnEntry 2 } rcPortPoeMainPseExtnPwrPriority OBJECT-TYPE SYNTAX INTEGER { critical(1), high(2), low(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "An index value that uniquely identifies the group containing the port to which a power Etherenet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for as identified by the same value of ifIndex." DEFVAL { low } ::= { rcPortPoeMainPseExtnEntry 3 } rcPortPoeMainPseExtnDeviceDetectType OBJECT-TYPE SYNTAX INTEGER { p802dot3af(1), p802dot3afAndLegacy(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "An index value that uniquely identifies the group containing the port to which a power Etherenet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for as identified by the same value of ifIndex." DEFVAL { p802dot3afAndLegacy } ::= { rcPortPoeMainPseExtnEntry 4 } rcPortPoeMainPseExtnPwrLimit OBJECT-TYPE SYNTAX INTEGER (37..800) MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum available PoE power of the main PSE expressed in Watts." DEFVAL { 200 } ::= { rcPortPoeMainPseExtnEntry 5 } -- POE Pse Port extn table rcPortPoePsePortExtnTable OBJECT-TYPE SYNTAX SEQUENCE OF RcPortPoePsePortExtnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port table" ::= { rcPortPoe 3 } rcPortPoePsePortExtnEntry OBJECT-TYPE SYNTAX RcPortPoePsePortExtnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing info. for a particular port" INDEX { rcPortPoePsePortExtnGroupIndex, rcPortPoePsePortExtnPortIndex } ::= { rcPortPoePsePortExtnTable 1 } RcPortPoePsePortExtnEntry ::= SEQUENCE { rcPortPoePsePortExtnGroupIndex INTEGER, rcPortPoePsePortExtnPortIndex INTEGER, rcPortPoePsePortExtnPwrLimit INTEGER, rcPortPoePsePortExtnMeasuredVolt Integer32, rcPortPoePsePortExtnMeasuredCurrent Integer32, rcPortPoePsePortExtnPwrConsumpt Integer32 } rcPortPoePsePortExtnGroupIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "An index value that uniquely identifies an interface to a PSE port device. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex." ::= { rcPortPoePsePortExtnEntry 1 } rcPortPoePsePortExtnPortIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "An index value that uniquely identifies an interface to a PSE port device. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex." ::= { rcPortPoePsePortExtnEntry 2 } rcPortPoePsePortExtnPwrLimit OBJECT-TYPE SYNTAX INTEGER (3..16) MAX-ACCESS read-write STATUS current DESCRIPTION "An index value that uniquely identifies the group containing the port to which a power Etherenet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for as identified by the same value of ifIndex." DEFVAL { 16 } ::= { rcPortPoePsePortExtnEntry 3 } rcPortPoePsePortExtnMeasuredVolt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An index value that uniquely identifies the group containing the port to which a power Etherenet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for as identified by the same value of ifIndex." ::= { rcPortPoePsePortExtnEntry 4 } rcPortPoePsePortExtnMeasuredCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An index value that uniquely identifies the group containing the port to which a power Etherenet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for as identified by the same value of ifIndex." ::= { rcPortPoePsePortExtnEntry 5 } rcPortPoePsePortExtnPwrConsumpt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An index value that uniquely identifies the group containing the port to which a power Etherenet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for as identified by the same value of ifIndex." ::= { rcPortPoePsePortExtnEntry 6 } -- PORT LACP rcPortLacpTable OBJECT-TYPE SYNTAX SEQUENCE OF RcPortLacpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port LACP table" ::= { rcPort 4 } rcPortLacpEntry OBJECT-TYPE SYNTAX RcPortLacpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing info. for a particular port" INDEX { rcPortIndex } ::= { rcPortLacpTable 1 } RcPortLacpEntry ::= SEQUENCE { rcPortLacpAdminEnable TruthValue, rcPortLacpOperEnable TruthValue, rcPortLacpFastPeriodicTime INTEGER, rcPortLacpSlowPeriodicTime INTEGER, rcPortLacpTimeoutScale INTEGER, rcPortLacpAggrWaitTime INTEGER, rcPortLacpFastPeriodicTimeOper INTEGER, rcPortLacpSlowPeriodicTimeOper INTEGER, rcPortLacpTimeoutScaleOper INTEGER, rcPortLacpAggrWaitTimeOper INTEGER } rcPortLacpAdminEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Administratively enable/disable LACP on a port" DEFVAL { false } ::= { rcPortLacpEntry 1 } rcPortLacpOperEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if LACP is operationally enabled or disabled on a port" ::= { rcPortLacpEntry 2 } rcPortLacpFastPeriodicTime OBJECT-TYPE SYNTAX INTEGER (200..20000) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of miliseconds between periodic transmissions using Short Timeouts." DEFVAL { 1000 } ::= { rcPortLacpEntry 3 } rcPortLacpSlowPeriodicTime OBJECT-TYPE SYNTAX INTEGER (10000..30000) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of miliseconds between periodic transmissions using LONG Timeouts." DEFVAL { 30000 } ::= { rcPortLacpEntry 4 } rcPortLacpTimeoutScale OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Scalar value used to calculate timeout time from periodic time. Timeout = PeriodicTime * TimeoutScale" DEFVAL { 3 } ::= { rcPortLacpEntry 5 } rcPortLacpAggrWaitTime OBJECT-TYPE SYNTAX INTEGER (200..2000) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of mili seconds to delay aggregation to allow multiple links to aggregate simultaneously." DEFVAL { 2000 } ::= { rcPortLacpEntry 6 } rcPortLacpFastPeriodicTimeOper OBJECT-TYPE SYNTAX INTEGER (10..20000) MAX-ACCESS read-only STATUS current DESCRIPTION "The operating value of fast periodic timer on the port." ::= { rcPortLacpEntry 7 } rcPortLacpSlowPeriodicTimeOper OBJECT-TYPE SYNTAX INTEGER (10..30000) MAX-ACCESS read-only STATUS current DESCRIPTION "The operating value of slow periodic timer on the port." ::= { rcPortLacpEntry 8 } rcPortLacpTimeoutScaleOper OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The operating value of timeout scale on the port." ::= { rcPortLacpEntry 9 } rcPortLacpAggrWaitTimeOper OBJECT-TYPE SYNTAX INTEGER (10..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "The operating value of aggreagate wait time on port." ::= { rcPortLacpEntry 10 } rcPortVLacpTable OBJECT-TYPE SYNTAX SEQUENCE OF RcPortVLacpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port Virtual LACP table" ::= { rcPort 5 } rcPortVLacpEntry OBJECT-TYPE SYNTAX RcPortVLacpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing info. for a particular port" INDEX { rcPortIndex } ::= { rcPortVLacpTable 1 } RcPortVLacpEntry ::= SEQUENCE { rcPortVLacpAdminEnable TruthValue, rcPortVLacpOperEnable TruthValue, rcPortVLacpFastPeriodicTimer INTEGER, rcPortVLacpSlowPeriodicTimer INTEGER, rcPortVLacpTimeout INTEGER, rcPortVLacpTimeoutScale INTEGER, rcPortVLacpEtherType Integer32, rcPortVLacpEtherMacAddress MacAddress, rcPortVLacpPortState INTEGER, rcPortVLacpDualHomingEnable TruthValue } rcPortVLacpAdminEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Administratively enable/disable Virtual LACP on a port" DEFVAL { false } ::= { rcPortVLacpEntry 1 } rcPortVLacpOperEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if Virtual LACP is operationally enabled or disabled on a port" ::= { rcPortVLacpEntry 2 } rcPortVLacpFastPeriodicTimer OBJECT-TYPE SYNTAX INTEGER (200..20000) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of miliseconds between periodic transmissions using Short Timeouts" DEFVAL { 250 } ::= { rcPortVLacpEntry 3 } rcPortVLacpSlowPeriodicTimer OBJECT-TYPE SYNTAX INTEGER (10000..30000) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of miliseconds between periodic transmissions using LONG Timeouts." DEFVAL { 30000 } ::= { rcPortVLacpEntry 4 } rcPortVLacpTimeout OBJECT-TYPE SYNTAX INTEGER { short(1), long(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Timeout control value. Long or Short Timeout" ::= { rcPortVLacpEntry 5 } rcPortVLacpTimeoutScale OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Scalar value used to calculate timeout time from periodic time. Timeout = PeriodicTime * TimeoutScale" DEFVAL { 3 } ::= { rcPortVLacpEntry 6 } rcPortVLacpEtherType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "VLACP Protocol Identification. The id value is in Hex" DEFVAL { 8103 } ::= { rcPortVLacpEntry 7 } rcPortVLacpEtherMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Multicast Mac Address exclusively used for VLACPDU's" ::= { rcPortVLacpEntry 8 } rcPortVLacpPortState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Display the Vlacp Port State." ::= { rcPortVLacpEntry 9 } rcPortVLacpDualHomingEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable Dual homing on Virtual LACP on a port" DEFVAL { false } ::= { rcPortVLacpEntry 10 } -- Port Remote Mirroring Table rcPortRemoteMirroringTable OBJECT-TYPE SYNTAX SEQUENCE OF RcPortRemoteMirroringEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port Remote Mirroring Table" ::= { rcPort 6 } rcPortRemoteMirroringEntry OBJECT-TYPE SYNTAX RcPortRemoteMirroringEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing remote mirroring info. for a particular port" INDEX { rcPortRemoteMirroringIndex } ::= { rcPortRemoteMirroringTable 1 } RcPortRemoteMirroringEntry ::= SEQUENCE { rcPortRemoteMirroringIndex InterfaceIndex, rcPortRemoteMirroringEnable TruthValue, rcPortRemoteMirroringMode INTEGER, rcPortRemoteMirroringSrcMac MacAddress, rcPortRemoteMirroringDstMac MacAddress, rcPortRemoteMirroringEtherType INTEGER, rcPortRemoteMirroringVlanIdListSize INTEGER, rcPortRemoteMirroringVlanIdList OCTET STRING, rcPortRemoteMirroringRowStatus RowStatus } rcPortRemoteMirroringIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "An index value that uniquely identifies a port. This value is similar to ifIndex in MIB2." ::= { rcPortRemoteMirroringEntry 1 } rcPortRemoteMirroringEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "To enable remote Mirroring for the port" DEFVAL { false } ::= { rcPortRemoteMirroringEntry 2 } rcPortRemoteMirroringMode OBJECT-TYPE SYNTAX INTEGER { source(1), termination(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Mode in which remote mirroring is enabled" DEFVAL { source } ::= { rcPortRemoteMirroringEntry 3 } rcPortRemoteMirroringSrcMac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Source Mac of the remote mirrored packet. Remote mirroring packet will be send with this source mac address" ::= { rcPortRemoteMirroringEntry 4 } rcPortRemoteMirroringDstMac OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Destination Mac of the remote mirrored packet. Packets will be bridged to this mac address. Remote mirroring packet will be send to this mac address" ::= { rcPortRemoteMirroringEntry 5 } rcPortRemoteMirroringEtherType OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Ethertype of the remote mirrored packet. Packets will be send with this ethertype" DEFVAL { '8103'h } ::= { rcPortRemoteMirroringEntry 6 } rcPortRemoteMirroringVlanIdListSize OBJECT-TYPE SYNTAX INTEGER (0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of VLAN IDs that are assigned to this port." ::= { rcPortRemoteMirroringEntry 7 } rcPortRemoteMirroringVlanIdList OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4096)) MAX-ACCESS read-write STATUS current DESCRIPTION "This field is used only if the port is assigned as remote mirroring termination port. Represents zero or more filter lists vlan in which the Destination Mac address resides. Each VLAN ID is stored as two bytes in this array starting from offset zero. Any unused bytes should be set to zero." ::= { rcPortRemoteMirroringEntry 8 } rcPortRemoteMirroringRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "RowStatus" ::= { rcPortRemoteMirroringEntry 9 } -- Start of Vlacp session rcPortVlacpSessionTable OBJECT-TYPE SYNTAX SEQUENCE OF RcPortVlacpSessionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table used to maintain Vlacp session values." ::= { rcPort 7 } rcPortVlacpSessionEntry OBJECT-TYPE SYNTAX RcPortVlacpSessionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing Vlacp Session information regarding a particular port or mlt." INDEX { rcPortVlacpSessionIfIndex, rcPortVlacpSessionSesNumber } ::= { rcPortVlacpSessionTable 1 } RcPortVlacpSessionEntry ::= SEQUENCE { rcPortVlacpSessionIfIndex Integer32, rcPortVlacpSessionSesNumber Integer32, rcPortVlacpSessionSrcMacAddress MacAddress, rcPortVlacpSessionRxTimer Integer32, rcPortVlacpSessionValidbit INTEGER, rcPortVlacpSessionInPktCount Integer32 } rcPortVlacpSessionIfIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "IfIndex of the port or Mlt" ::= { rcPortVlacpSessionEntry 1 } rcPortVlacpSessionSesNumber OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Session number of an IfIndex" ::= { rcPortVlacpSessionEntry 2 } rcPortVlacpSessionSrcMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Mac Address for the session" ::= { rcPortVlacpSessionEntry 3 } rcPortVlacpSessionRxTimer OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Rx timer for the session" ::= { rcPortVlacpSessionEntry 4 } rcPortVlacpSessionValidbit OBJECT-TYPE SYNTAX INTEGER { inValidSession(0), validSession(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The valid bit for the session" ::= { rcPortVlacpSessionEntry 5 } rcPortVlacpSessionInPktCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The In packet count for the session" ::= { rcPortVlacpSessionEntry 6 } -- End of Vlacp session -- Management port details rcPortMgmtLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF RcPortMgmtLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port card mgmt port link table" ::= { rcPort 8 } rcPortMgmtLinkEntry OBJECT-TYPE SYNTAX RcPortMgmtLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing info. for a particular mgmt port in I/O card" INDEX { rcPortMgmtLinkIndex } ::= { rcPortMgmtLinkTable 1 } RcPortMgmtLinkEntry ::= SEQUENCE { rcPortMgmtLinkIndex InterfaceIndex, rcPortMgmtLinkDescr DisplayString, rcPortMgmtLinkOperStatus INTEGER, rcPortMgmtLinkAutoNegotiate TruthValue, rcPortMgmtLinkDuplex INTEGER, rcPortMgmtLinkSpeed INTEGER } rcPortMgmtLinkIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "IfIndex of the port." ::= { rcPortMgmtLinkEntry 1 } rcPortMgmtLinkDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Port description" ::= { rcPortMgmtLinkEntry 2 } rcPortMgmtLinkOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "admin status of the mgmt port" ::= { rcPortMgmtLinkEntry 3 } rcPortMgmtLinkAutoNegotiate OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Auto-negotiation status of the port" ::= { rcPortMgmtLinkEntry 4 } rcPortMgmtLinkDuplex OBJECT-TYPE SYNTAX INTEGER { half(1), full(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "duplex setting for the port" ::= { rcPortMgmtLinkEntry 5 } rcPortMgmtLinkSpeed OBJECT-TYPE SYNTAX INTEGER { none(0), mbps10(1), -- 10Mb/s mbps100(2), -- 100Mb/s mbps1000(3) -- 1000Mb/s } MAX-ACCESS read-only STATUS current DESCRIPTION "speed setting for this port." ::= { rcPortMgmtLinkEntry 6 } -- PORT FlushFdbTable rcPortFlushFdbTable OBJECT-TYPE SYNTAX SEQUENCE OF RcPortFlushFdbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port Flush Fdbtable" ::= { rcPort 9 } rcPortFlushFdbEntry OBJECT-TYPE SYNTAX RcPortFlushFdbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "port based deletion of mac addresses learned or discarded on that port" INDEX { rcPortIndex } ::= { rcPortFlushFdbTable 1 } RcPortFlushFdbEntry ::= SEQUENCE { rcPortFlushFdbAddress DisplayString, rcPortFlushFdbVlanId Integer32 } rcPortFlushFdbAddress OBJECT-TYPE SYNTAX DisplayString (SIZE (17)) MAX-ACCESS read-write STATUS current DESCRIPTION "Mac Address to be deleted." ::= { rcPortFlushFdbEntry 1 } rcPortFlushFdbVlanId OBJECT-TYPE SYNTAX Integer32(1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "vlan Id associated with the Mac Address" ::= { rcPortFlushFdbEntry 2 } -- Port Lock Group rcPortLock OBJECT IDENTIFIER ::= { rcChassis 11 } rcPortLockEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicate whether the port lock feature is enabled." DEFVAL { false } ::= { rcPortLock 1 } rcPortLockLockedPorts OBJECT-TYPE SYNTAX PortSet MAX-ACCESS read-write STATUS current DESCRIPTION "The set of ports that are administratively locked. Locked ports cannot be modified in anyway until the port is unlocked first." ::= { rcPortLock 2 } -- Test Group rcTestExtTable OBJECT-TYPE SYNTAX SEQUENCE OF RcTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Test extension table. This table augments the standard ifTestTable table in RFC1573." ::= { rcTest 1 } rcTestEntry OBJECT-TYPE SYNTAX RcTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Proprietary test variables." INDEX { rcTestExtIfIndex } ::= { rcTestExtTable 1 } RcTestEntry ::= SEQUENCE { rcTestExtIfIndex InterfaceIndex, rcTestExtPassCount Integer32, rcTestExtFailCount Integer32 } rcTestExtIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex." ::= { rcTestEntry 1 } rcTestExtPassCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of iterations of the test case that completed successfully." ::= { rcTestEntry 2} rcTestExtFailCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of iterations of the test case that failed." ::= { rcTestEntry 3} rcTestTypes OBJECT IDENTIFIER ::= { rcTest 2} rcTestTypesFabric OBJECT IDENTIFIER ::= { rcTestTypes 1 } rcTestTypesArTable OBJECT IDENTIFIER ::= { rcTestTypes 2 } rcTestTypesExtLoopBack OBJECT IDENTIFIER ::= { rcTestTypes 3 } rcTestCodes OBJECT IDENTIFIER ::= { rcTest 3 } rcTestCodesNoReceive OBJECT IDENTIFIER ::= { rcTestCodes 1 } rcTestCodesBadSeq OBJECT IDENTIFIER ::= { rcTestCodes 2 } rcTestCodesBadLen OBJECT IDENTIFIER ::= { rcTestCodes 3 } rcTestCodesBadData OBJECT IDENTIFIER ::= { rcTestCodes 4 } -- Statistics rcStatTable OBJECT-TYPE SYNTAX SEQUENCE OF RcStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table used to store port statistics." ::= { rcStat 1 } rcStatEntry OBJECT-TYPE SYNTAX RcStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "interface counters" INDEX { rcStatPortIndex } ::= { rcStatTable 1 } RcStatEntry ::= SEQUENCE { rcStatPortIndex InterfaceIndex, rcStatFrameTooShorts Counter32, rcStatBridgeInUnicastFrames Counter32, rcStatBridgeInMulticastFrames Counter32, rcStatBridgeInBroadcastFrames Counter32, rcStatBridgeInDiscards Counter32, rcStatBridgeOutUnicastFrames Counter32, rcStatBridgeOutMulticastFrames Counter32, rcStatBridgeOutBroadcastFrames Counter32, rcStatRouteInUnicastFrames Counter32, rcStatRouteInMulticastFrames Counter32, rcStatRouteInDiscards Counter32, rcStatRouteOutUnicastFrames Counter32, rcStatRouteOutMulticastFrames Counter32, rcStatStgForwardTransitions Counter32, rcStatStgInConfigBpdus Counter32, rcStatStgInTcnBpdus Counter32, rcStatStgInBadBpdus Counter32, rcStatStgOutConfigBpdus Counter32, rcStatStgOutTcnBpdus Counter32, rcStatBridgeOutFrames Counter32 } rcStatPortIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "An index value that uniquely identifies a port. This value is similar to ifIndex in MIB2." ::= { rcStatEntry 1 } rcStatFrameTooShorts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames that are too short that were encountered on this interface." ::= { rcStatEntry 2 } rcStatBridgeInUnicastFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of incoming unicast frames that were bridged." ::= { rcStatEntry 3 } rcStatBridgeInMulticastFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of incoming multicast frames that were bridged." ::= { rcStatEntry 4 } rcStatBridgeInBroadcastFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of incoming broadcast frames that were bridged." ::= { rcStatEntry 5 } rcStatBridgeInDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames that were discarded by the bridging entity." ::= { rcStatEntry 6 } rcStatBridgeOutUnicastFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of outgoing unicast frames that were bridged." ::= { rcStatEntry 7 } rcStatBridgeOutMulticastFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of outgoing multicast frames that were bridged." ::= { rcStatEntry 8 } rcStatBridgeOutBroadcastFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of outgoing broadcast frames that were bridged." ::= { rcStatEntry 9 } rcStatRouteInUnicastFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of incoming unicast frames that were routed." ::= { rcStatEntry 10 } rcStatRouteInMulticastFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of incoming multicast frames that were routed." ::= { rcStatEntry 11 } rcStatRouteInDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames that were discarded by the routing entity." ::= { rcStatEntry 12 } rcStatRouteOutUnicastFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of outgoing unicast frames that were routed." ::= { rcStatEntry 13 } rcStatRouteOutMulticastFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of outgoing multicast frames that were routed." ::= { rcStatEntry 14 } rcStatStgForwardTransitions OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times this port has transitioned from the Learning state to the Forwarding state." ::= { rcStatEntry 15 } rcStatStgInConfigBpdus OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { rcStatEntry 16 } rcStatStgInTcnBpdus OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { rcStatEntry 17 } rcStatStgInBadBpdus OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { rcStatEntry 18 } rcStatStgOutConfigBpdus OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { rcStatEntry 19 } rcStatStgOutTcnBpdus OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { rcStatEntry 20 } rcStatBridgeOutFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used by the Accelar 8000 product family to account for all transmitted bridge unicast, broadcast, and multicast packets. The individual counters are not supported." ::= { rcStatEntry 21 } END