#-MIBFILE: cpqrpm.mib CPQRPM-MIB DEFINITIONS ::= BEGIN compaq OBJECT IDENTIFIER ::= { enterprises 232 } DisplayString ::= OCTET STRING PhysAddress ::= OCTET STRING mib-2 OBJECT IDENTIFIER ::= { mgmt 1 } system OBJECT IDENTIFIER ::= { mib-2 1 } sysName OBJECT IDENTIFIER ::= { system 5 } cpqRPM OBJECT IDENTIFIER ::= { compaq 154 } cpqRPMTrapInfo OBJECT IDENTIFIER ::= { cpqRPM 1 } cpqRPMTraps OBJECT IDENTIFIER ::= { cpqRPM 2 } cpqPMTraps OBJECT IDENTIFIER ::= { cpqRPM 3 } cpqRPMTrapDescription OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Text description of the event that caused the trap." ::= { cpqRPMTrapInfo 1 } cpqRPMTrapDeviceId OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "A unique numeric identifier for the device that caused the trap." ::= { cpqRPMTrapInfo 2 } cpqRPMTrapDeviceName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..50)) ACCESS read-only STATUS mandatory DESCRIPTION "The text name for the device." ::= { cpqRPMTrapInfo 3 } cpqRPMTrapDeviceAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..50)) ACCESS read-only STATUS mandatory DESCRIPTION "The hostname or ip address for the device." ::= { cpqRPMTrapInfo 4 } cpqRPMTrapType OBJECT-TYPE SYNTAX INTEGER { system(1), event(2), change(3), power(4), environment(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the type of the event that caused the trap." ::= { cpqRPMTrapInfo 5 } cpqRPMTrapSeverity OBJECT-TYPE SYNTAX INTEGER { unknown(1), information(2), normal(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the severity of the event that caused the trap." ::= { cpqRPMTrapInfo 6 } cpqRPMTrapCode OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "A unique identifier for the alarm." ::= { cpqRPMTrapInfo 7 } cpqRPMTrapURL OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The URL for the management software." ::= { cpqRPMTrapInfo 8 } cpqRPMTrapUPSInternalFailureCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Internal Failure Cleared (20112)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting an internal failure has been cleared." ::= 20112 cpqRPMTrapCMCSmokeCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Smoke Cleared (10032)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting smoke cleared." ::= 10032 cpqRPMTrapCMCInput1Opened TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MINOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Input 1 Opened (10101)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting input 1 has been opened." ::= 10101 cpqRPMTrapCMCLockset1FailedToLock TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Lockset 1 Failed To Lock (10112)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting lockset 1 has failed to lock." ::= 10112 cpqRPMTrapUPSOutputOverloadCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Output Overload Cleared (20015)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting output overload is cleared." ::= 20015 cpqRPMTrapCMCShockCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Shock Cleared (10042)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting shock cleared." ::= 10042 cpqRPMTrapCMCTemp1Normal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Temperature 1 Normal (10004)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting temperature 1 has returned to a normal temperature." ::= 10004 cpqRPMTrapUPSSiteWiringNormal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Site Wiring Fault Cleared (20202)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "The input wiring is normal." ::= 20202 cpqRPMTrapUPSTemperatureLow TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Temperature Low (20101)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting temperature blow minimum threshold." ::= 20101 cpqRPMTrapUPSOnUtilityPower TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS On Utility Power (21064)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is supplying output with utility power." ::= 21064 cpqRPMTrapUPSFanFailure TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY CRITICAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "The UPS has encountered an fan failure. (21035)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting a fan failure has occurred. Recommendations: 1If this error persists contact technical support." ::= 21035 cpqRPMTrapUPSBypassManualTurnedOff TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Bypass Manual Turned Off (20192)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "The bypass has been given a manual turn off command." ::= 20192 cpqRPMTrapCMCInput1Closed TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Input 1 Closed (10102)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting input 1 has been closed." ::= 10102 cpqRPMTrapUPSShutdownImminentCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "The UPS is no longer in an imminent shutdown state. (21014)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting a shutdown imminent condition. Recommendations: 1Immediately restore power to the UPS. The UPS will not continue to supply power to devices following the shutdown!" ::= 21014 cpqRPMTrapDeviceSettingsChanged TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MINOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Device Settings Changed (5)" --#ENABLE true --#CATEGORY "APPLICATION" DESCRIPTION "Device settings have been changed by a user." ::= 5 cpqRPMTrapConnectionFailed TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY CRITICAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Connection Failed (4)" --#ENABLE true --#CATEGORY "APPLICATION" DESCRIPTION "CRPM failed to connect to a device." ::= 4 cpqRPMTestTrap TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Test Trap (50001)" --#ENABLE true --#CATEGORY "APPLICATION" DESCRIPTION "This trap is sent to test SNMP setup." ::= 50001 cpqRPMTrapCMCShockDetected TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Shock Detected (10041)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting shock detected." ::= 10041 cpqRPMTrapUPSBatteriesDisconnected TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "One or more UPS batteries have been disconnected. (21053)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting batteries are not connected to the UPS. Recomendations: 1Connect the UPS Batteries. The UPS will not be capable of supporting it's load if the utility power fails!" ::= 21053 cpqRPMTrapCMCLockset2Locked TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Lockset 2 Locked (10119)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting lockset 2 has been locked." ::= 10119 cpqRPMtrapUPSOutputoutofRange TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY CRITICAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Output voltage is out of range (21019)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting output voltage is out of Range. Recommendations: 1Initiate a UPS self test. 2If this error persists contact technical support." ::= 21019 cppqRPMtrapUPSStartedOnBatteryCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Utility power has been restored (20152)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device has been started while on battery power. AC input power is not present. Recommendations: 1Check to make sure the UPS is plugged into an outlet supplied with utility power. If the UPS remains on battery for an extended time it will not be able to sustain the output load!" ::= 20152 cpqRPMTrapConnectionLost TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY CRITICAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Connection Lost (2)" --#ENABLE true --#CATEGORY "APPLICATION" DESCRIPTION "CRPM lost the connection to a device." ::= 2 cpqRPMTrapUPSOnBoost TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS On Boost (21031)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is boosting output voltage." ::= 21031 cpqRPMTrapUPSInputUnderOverFreqCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Input Frequency Normal (20142)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "Measured input frequency is normal" ::= 20142 cpqRPMTrapUPSBatteryLowCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Battery Low Cleared (21056)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting low battery. Recommendations: 1Check to make sure the UPS is plugged into an outlet supplied with utility power. 2When utility power is restored, charge the battery to it's full capacity. If the battery level continues to decrease, the UPS will not be able to sustain the output load!" ::= 21056 cpqRPMTrapUPSBatteryFailureCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Battery Failure Cleared (20122)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting a battery failure has been cleared." ::= 20122 cpqRPMTrapCMCTemp2AboveMax TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Temperature 2 Above Maximum (10007)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting temperature 2 above maximum threshold." ::= 10007 cpqRPMTrapCMCTemp1AboveWarn TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MINOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Temperature 1 Above Warning (10002)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting temperature 1 above warning threshold." ::= 10002 cpqRPMTrapCMCTemp2BelowMin TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Temperature 2 Below Minimum (10005)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting temperature 2 below minimum threshold." ::= 10005 cpqRPMTrapUPSBatteryFailure TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Battery Failure (20121)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting a battery failure." ::= 20121 cpqRPMTrapCMCLockset1Error TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Lockset 1 Error (10113)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting an error with lockset 1." ::= 10113 cpqRPMTrapUPSDCStartOccurredCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "DC Start Occurred Cleared (29999)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "The UPS has been started on utility while AC input power is present." ::= 29999 cpqRPMTrapUPSBatteryLevelNormal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Battery Level Normal (20023)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting a normal battery level." ::= 20023 cpqRPMTrapCMCLockset1Unlocked TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Lockset 1 Unlocked (10111)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting lockset 1 has been unlocked." ::= 10111 cpqRPMTrapUPSOnBattery TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS On Battery (21063)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is supplying output with its battery." ::= 21063 cpqRPMTrapCMCLockset1Locked TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Lockset 1 Locked (10114)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting lockset 1 has been locked." ::= 10114 cpqPMTrapCleared TRAP-TYPE ENTERPRISE cpqPMTraps VARIABLES { sysName, cpqRPMTrapCode, cpqRPMTrapDescription, cpqRPMTrapDeviceName, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Trap code: # $V3V#Description: # $V4V#Name: # $V5V#Url: #" --#TYPE "Cleared Alarm (4)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "An alarm has cleared. Action: Check the Trap Details for more information." ::= 4 cpqRPMTrapUPSTemperatureHigh TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Temperature High (20102)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting temperature above maximum threshold." ::= 20102 cpqRPMTrapCMCHmdtOver TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Humidity Above Maximum (10022)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting humidity above maximum threshold." ::= 10022 cpqRPMTrapUPSLossOfRedundancy TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "The UPS N+1 load has been exceeded (21023)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting a loss of redundancy due to one of the following. 1One or more of the Electronics Modules has failed 2One or more of the electronics modules has been manually removed. 3The amount of load on the UPS has increased to the point that the UPS is no longer able to support an N+1 configuration. Recommendations: 1Check the UPS to see if one of the modules has failed. 2Make sure that all modules are securely plugged in. 3Reduce the load to return the N+1 configuration. 4If the amount of load is now going to exceed and N+1 configuration permanently, change the configuration on the front panel of the UPS to Capacity instead of Parallel N+1." ::= 21023 cpqRPMTrapUPSUtilityFailCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Utility Fail Cleared (20172)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "Indicates that the utility input power is within predetermined limits." ::= 20172 cpqRPMtrapUPSBypassONManual TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "The UPS is on manual bypass (21059)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is operating in manual bypass mode. Recommendations: 1In bypass mode, the UPS cannot support devices if there is a power failure. 2Once maintenance has been performed return the UPS to normal mode." ::= 21059 cpqRPMTrapUPSOnBuck TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS On Buck (21029)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device reducing output voltage." ::= 21029 cpqRPMtrapUPSInputOutofRangeCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Input voltage is normal (21022)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting input voltage is out of range. Recommendations: 1Check to make sure the UPS is plugged into an outlet supplied with utility power. 2If the UPS remains on battery for an extended period of time it will not be able to sustain the load." ::= 21022 cpqRPMTrapCMCHmdtUnder TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Humidity Below Minimum (10021)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting humidity below minimum threshold." ::= 10021 cpqRPMTrapUPSCheckBreakerCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "All breakers are functioning normally. (21042)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting an output Breaker or Relay has failed or may be stuck open or closed with this alarm. Recommendations: 1Check all breakers on the UPS. 2If this error persists contact technical support." ::= 21042 cpqRPMTrapUPSUtilityNotPresentCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Utility Not Present Cleared (20182)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "Indicates that the utility input is present." ::= 20182 cpqRPMTrapCMCLockset2Error TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Lockset 2 Error (10118)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting an error with lockset 2." ::= 10118 cpqRPMTrapUPSShutdownPendingCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "The UPS is no longer pending shutdown. (21012)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting shutdown pending condition. Recommendations: 1Immediately restore power to the UPS. The UPS will not continue to supply power to devices following the shutdown!" ::= 21012 cpqRPMTrapCMCLockset2FailedToLock TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Lockset 2 Failed To Lock (10117)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting lockset 2 has failed to lock." ::= 10117 cpqRPMTrapUPSInternalFailure TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Internal Failure (20111)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting an internal failure." ::= 20111 cpqRPMTrapCMCLockset2Normal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Lockset 2 Normal (10135)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting lockset 2 is normal." ::= 10135 cpqRPMTrapUPSFanFailureCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "The UPS fan failure has cleared. (21036)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting a fan failure has occurred. Recommendations: 1If this error persists contact technical support." ::= 21036 cpqRPMTrapLookupFailed TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY CRITICAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "DNS Lookup Failed (3)" --#ENABLE true --#CATEGORY "APPLICATION" DESCRIPTION "CRPM failed to find an IP address for the device hostname." ::= 3 cpqRPMTrapUPSEPOInitiated TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY CRITICAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Emergency Power Off activated (21037)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting an Emergency Power Off (EPO) command has been received to shutdown the UPS immediately with out delay. This command may come from a local control panel or from a remote source. Recommendations: 1Turn the UPS on to reapply power to attached equipment." ::= 21037 cpqRPMTrapCMCAux2Cleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Aux 2 Alarm Cleared (10054)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting auxiliary input 2 alarm cleared." ::= 10054 cpqRPMTrapCMCHmdtNormal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Humidity Normal (10023)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting humidity has returned to normal." ::= 10023 cpqRPMTrapUPSUtilityFail TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Utility Fail (20171)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "Indicates that the utility input power is not within predetermined limits. This could be, but is not limited to, over voltage, under voltage, over frequency, under frequency or over current." ::= 20171 cpqRPMTrapCMCVoltUnder TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Voltage Below Minimum (10011)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting voltage below minimum threshold." ::= 10011 cpqRPMTrapCMCInput4Closed TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Input 4 Closed (10108)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting input 4 has been closed." ::= 10108 cpqRPMTrapUPSDCStartOccurred TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "DC Start Occurred (29998)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "The UPS has been started on battery when AC input power is not present. This alarm is used to record the date and time of this event." ::= 29998 cpqRPMTrapUPSBatteryDischarged TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "The UPS batteries are in a discharged condition. (21057)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting batteries are completely discharged. Recommendations: 1Connect the UPS to utility power to charge the batteries. The UPS will not be able to support it's load if the utility power fails!" ::= 21057 cpqRPMTrapUPSBatteryDepleted TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Depleted Battery (20022)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is a depleted battery." ::= 20022 cpqRPMTrapCMCInput4Opened TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MINOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Input 4 Opened (10107)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting input 4 has been opened." ::= 10107 cpqRPMTrapUPSCabinetDoorOpenCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "A cover panel has been replaced. (21046)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting a cover panel has been removed while utility power is present. Recommendations: 1Reinstall all panels. 2If this error persists contact technical support." ::= 21046 cpqRPMTrapUPSBatteriesDisconnectedCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "All UPS batteries have been reconnected. (21054)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting batteries are not connected to the UPS. Recomendations: 1Connect the UPS Batteries. The UPS will not be capable of supporting it's load if the utility power fails!" ::= 21054 cpqRPMTrapUPSCheckBreaker TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "A UPS circuit breaker needs attention. (21041)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting an output Breaker or Relay has failed or may be stuck open or closed with this alarm. Recommendations: 1Check all breakers on the UPS. 2If this error persists contact technical support." ::= 21041 cpqRPMtrapUPSBypassOnAutoCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "The UPS is no longer on auto bypass (21048)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is operating in auto bypass mode. Recommendations: 1In bypass mode, the UPS cannot support devices if there is a power failure. 2Once maintenance has been performed return the UPS to normal mode." ::= 21048 cpqRPMtrapUPSTemperatureOutOfRange TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY CRITICAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS temperature out of range (21007)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting temperature is out of range. Recommendations: 1Check to make sure the UPS is in a well ventilated area. 2Lower the ambient temperature in the area where the UPS is located." ::= 21007 cpqRPMTrapUPSBatteryLow TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Battery Low (21055)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting a low battery." ::= 21055 cpqRPMTrapUPSTemperatureNormal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Temperature Normal (20103)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting temperature is normal." ::= 20103 cpqRPMTrapCMCAux1Alarm TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MINOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Aux 1 Alarm (10051)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device has entered an alarm condition for auxiliary input 1." ::= 10051 cpqRPMTrapUPSShutdownPending TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "A UPS shutdown is pending. (21011)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting shutdown pending condition. Recommendations: 1Immediately restore power to the UPS. The UPS will not continue to supply power to devices following the shutdown!" ::= 21011 cpqRPMTrapUPSOutputVoltageNormal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Output Voltage Normal (21020)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting output voltage is normal." ::= 21020 cpqRPMTrapCMCLockset1Normal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Lockset 2 Normal (10134)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting lockset 2 is normal." ::= 10134 cpqRPMTrapUPSDiagnosticTestFailed TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Diagnostic Test Failed (20131)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting a diagnostic test has failed." ::= 20131 cpqRPMTrapCMCVoltNormal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Voltage Normal (10013)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting voltage has returned to normal." ::= 10013 cpqRPMTrapUPSInputVoltageAboveMax TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Input Voltage Above Maximum (20002)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting input voltage above maximum threshold." ::= 20002 cpqRPMTrapUPSInputVoltageBelowMin TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Input Voltage Below Minimum (20001)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting input voltage below minimum threshold." ::= 20001 cpqRPMTrapUPSOnBypass TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY MINOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS On Bypass (20032)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is being bypassed." ::= 20032 cpqRPMTrapUPSUtilityNotPresent TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Utility Not Present (20181)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "Indicates that the utility input is not present. This differs from alarm #57 in that the detected voltage is zero in this case." ::= 20181 cpqPMTrapWarning TRAP-TYPE ENTERPRISE cpqPMTraps VARIABLES { sysName, cpqRPMTrapCode, cpqRPMTrapDescription, cpqRPMTrapDeviceName, cpqRPMTrapURL } --#SEVERITY MINOR --#MSG_FORMATTER "$V2V#Trap code: # $V3V#Description: # $V4V#Name: # $V5V#Url: #" --#TYPE "Warning Alarm (2)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A warning alarm has occurred. Action: Check the Trap Details for more information." ::= 2 cpqRPMTrapCMCLockset2Unlocked TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Lockset 2 Unlocked (10116)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting lockset 2 has been unlocked." ::= 10116 cpqRPMTrapUPSShutdownImminent TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY CRITICAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "A UPS shutdown is imminent. (21013)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting a shutdown imminent condition. Recommendations: 1Immediately restore power to the UPS. The UPS will not continue to supply power to devices following the shutdown!" ::= 21013 cpqRPMTrapCMCVoltOver TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Voltage Above Maximum (10012)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting voltage above maximum threshold." ::= 10012 cpqRPMTrapUPSInputUnderOverFreq TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Input Under Or Over Frequency (20141)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "Input (Utility) fault: measured input frequency is outside of either the upper or lower frequency limit specification for normal operation." ::= 20141 cpqRPMTrapUPSLossOfRedundancyCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Loss of redundancy cleared or configuration has changed from N+1 to Capacity (21024)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting a loss of redundancy due to one of the following. 1One or more of the Electronics Modules has failed 2One or more of the electronics modules has been manually removed. 3The amount of load on the UPS has increased to the point that the UPS is no longer able to support an N+1 configuration. Recommendations: 1Check the UPS to see if one of the modules has failed. 2Make sure that all modules are securely plugged in. 3Reduce the load to return the N+1 configuration. 4If the amount of load is now going to exceed and N+1 configuration permanently, change the configuration on the front panel of the UPS to Capacity instead of Parallel N+1." ::= 21024 cpqRPMTrapUPSSiteWiringFault TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Site Wiring Fault (20201)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "There is a fault in the input wiring." ::= 20201 cpqRPMTrapUPSOutputVoltageAboveMax TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY MINOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Output Voltage Above Maximum (20012)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting output voltage above maximum threshold." ::= 20012 cpqRPMTrapUPSBypassManualTurnedOn TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY MINOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Bypass Manual Turned On (20191)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "The bypass has been given a manual turn on command." ::= 20191 cppqRPMtrapUPSStartedOnBattery TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MINOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "The UPS was started without utility power (20151)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device has been started while on battery power. AC input power is not present. Recommendations: 1Check to make sure the UPS is plugged into an outlet supplied with utility power. If the UPS remains on battery for an extended time it will not be able to sustain the output load." ::= 20151 cpqRPMTrapCMCAux2Alarm TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MINOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Aux 2 Alarm (10053)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device has entered an alarm condition for auxiliary input 2." ::= 10053 cpqRPMTrapUPSInputVoltageNormal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Input Voltage Normal (20003)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting input voltage is normal." ::= 20003 cpqRPMTrapUPSOutputVoltageBelowMin TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY MINOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Output Voltage Below Minimum (20011)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting output voltage below minimum threshold." ::= 20011 cpqRPMTrapCMCInput3Closed TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Input 3 Closed (10106)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting input 3 has been closed." ::= 10106 cpqRPMTrapCMCTemp1AboveMax TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Temperature 1 Above Maximum (10003)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting temperature 1 above maximum threshold." ::= 10003 cpqRPMTrapUPSCabinetDoorOpen TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY CRITICAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "A cover panel has been removed. (21045)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting a cover panel has been removed while utility power is present. Recommendations: 1Reinstall all panels. 2If this error persists contact technical support." ::= 21045 cpqRPMTrapCMCInput3Opened TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MINOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Input 3 Opened (10105)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting input 3 has been opened." ::= 10105 cpqPMTrapInformation TRAP-TYPE ENTERPRISE cpqPMTraps VARIABLES { sysName, cpqRPMTrapCode, cpqRPMTrapDescription, cpqRPMTrapDeviceName, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Trap code: # $V3V#Description: # $V4V#Name: # $V5V#Url: #" --#TYPE "Information Alarm (3)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "An information alarm has occurred. Action: Check the Trap Details for more information." ::= 3 cpqRPMTrapCMCTemp2AboveWarn TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MINOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Temperature 2 Above Warning (10006)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting temperature 2 above warning threshold." ::= 10006 cpqRPMTrapCMCTemp1BelowMin TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Temperature 1 Below Minimum (10001)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting temperature 1 below minimum threshold." ::= 10001 cpqRPMTrapUPSBypassNotAvailable TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Bypass Not Available (20161)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "The bypass input voltage is not available for transfer to. This may be due to any reason. Some of which are: over/under voltage, over/under frequency, out of phase lock." ::= 20161 cpqRPMTrapUPSOutputOverload TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Output Overload (20014)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting output is overloaded." ::= 20014 cpqRPMTrapUPSBatteryDischargedCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "The UPS batteries are in a discharged condition. (21058)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting batteries are completely discharged. Recommendations: 1Connect the UPS to utility power to charge the batteries. The UPS will not be able to support it's load if the utility power fails!" ::= 21058 cpqRPMtrapUPSTemperatureOutOfRangeCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS temperature has returned to normal (21008)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting temperature is out of range. Recommendations: 1Check to make sure the UPS is in a well ventilated area. 2Lower the ambient temperature in the area where the UPS is located." ::= 21008 cpqRPMTrapCMCSmokeDetected TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Smoke Detected (10031)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting smoke detected." ::= 10031 cpqRPMTrapCMCInput2Closed TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Input 2 Closed (10104)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting input 2 has been closed." ::= 10104 cpqRPMTrapUPSManualLoadDumped TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS output has been manually turned off. (21033)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "The UPS has been powered off with user interaction." ::= 21033 cpqRPMTrapUPSDiagnosticTestSucceeded TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS Diagnostic Test Succeeded (20132)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting a diagnostic test has succeeded." ::= 20132 cpqPMTrapCritical TRAP-TYPE ENTERPRISE cpqPMTraps VARIABLES { sysName, cpqRPMTrapCode, cpqRPMTrapDescription, cpqRPMTrapDeviceName, cpqRPMTrapURL } --#SEVERITY CRITICAL --#MSG_FORMATTER "$V2V#Trap code: # $V3V#Description: # $V4V#Name: # $V5V#Url: #" --#TYPE "Critical Alarm (1)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "A critical alarm has occurred. Action: Check the Trap Details for more information." ::= 1 cpqRPMTrapCMCInput2Opened TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MINOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Input 2 Opened (10103)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting input 2 has been opened." ::= 10103 cpqRPMtrapUPSBypassOnAuto TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "The UPS is on automatic bypass (21047)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is operating in auto bypass mode. Recommendations: 1In bypass mode, the UPS cannot support devices if there is a power failure. 2Once maintenance has been performed return the UPS to normal mode." ::= 21047 cpqRPMTrapCMCAux1Cleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Aux 1 Alarm Cleared (10052)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting auxiliary input 1 alarm cleared." ::= 10052 cpqRPMtrapUPSBypassOffManual TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "The UPS is no longer on manual bypass (21060)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is operating in manual bypass mode. Recommendations: 1In bypass mode, the UPS cannot support devices if there is a power failure. 2Once maintenance has been performed return the UPS to normal mode." ::= 21060 cpqRPMTrapUPSManualLoadDumpedCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "UPS output has been restored (21034)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "The UPS has been powered off with user interaction." ::= 21034 cpqRPMtrapUPSInputOutofRange TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY MAJOR --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Input voltage is out of range (21021)" --#CATEGORY "Proliant UPS Events" DESCRIPTION "A UPS device is reporting input voltage is out of range. Recommendations: 1Check to make sure the UPS is plugged into an outlet supplied with utility power. 2If the UPS remains on battery for an extended period of time it will not be able to sustain the load." ::= 21021 cpqRPMTrapCMCTemp2Normal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "CMC Temperature 2 Normal (10008)" --#ENABLE true --#CATEGORY "SYSTEM AND ENVIRONMENTAL" DESCRIPTION "A CMC device is reporting temperature 2 has returned to a normal temperature." ::= 10008 cpqRPMTrapUPSBypassNotAvailableCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Bypass Not Available Cleared (20162)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "The bypass input voltage is available for transfer to." ::= 20162 cpqRPMTrapDeviceConnected TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } --#SEVERITY INFORMATIONAL --#MSG_FORMATTER "$V2V#Description: # $V3V#ID: # $V4V#Name: # $V5V#Address: # $V6V#Trap Type: # $V7V#Severity: #" --#TYPE "Device Connected (1)" --#ENABLE true --#CATEGORY "APPLICATION" DESCRIPTION "CRPM successfully connected to a device." ::= 1 END