-- SECTION 1: Top Level Definitions S5-TOKENRING-COMMON-MIB DEFINITIONS ::= BEGIN -- 5000 Token Ring Common MIB Release 1.1.7 -- Revision 08/01/96 -- Copyright 1996 Bay Networks, Inc. -- All rights reserved. -- This Bay Networks SNMP Management Information Base Specification -- (Specification) embodies Bay Networks' confidential and -- proprietary intellectual property. Bay Networks retains all -- title and ownership in the Specification, including any -- revisions. -- This Specification is supplied "AS IS," and Bay Networks makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. -- Imports IMPORTS Counter, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB s5TrCfg, s5TrStat FROM S5-TOKENRING-MIB MacAddress, TimeIntervalSec, SrcIndx FROM S5-TCS-MIB; -- SECTION 2: Configuration information -- Port Table s5TrPortTable OBJECT-TYPE SYNTAX SEQUENCE OF S5TrPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing information about each port on a board. The number of entries is determined by the number of manageable ports. Those boards that do not have any manageable ports do not have any entries in this table." ::= { s5TrCfg 1 } s5TrPortEntry OBJECT-TYPE SYNTAX S5TrPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row in Token Ring port table. Entries can not be created or deleted via SNMP." INDEX { s5TrPortBrdIndx, s5TrPortIndx } ::= { s5TrPortTable 1 } S5TrPortEntry ::= SEQUENCE { s5TrPortBrdIndx INTEGER, s5TrPortIndx INTEGER, s5TrPortWrapStatus INTEGER, s5TrPortWrapTime TimeIntervalSec, s5TrPortInsrtStatus INTEGER, s5TrPortPhanStatus INTEGER, s5TrPortPhanChngs Counter, s5TrPortTrnkAccMthdStrap INTEGER, s5TrPortTrnkAccMthd INTEGER, s5TrPortClass INTEGER, s5TrPortMedia INTEGER, s5TrPortConnector INTEGER, s5TrPortSoftwareInsertion INTEGER, s5TrPortAFD INTEGER } s5TrPortBrdIndx OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the board. This corresponds to the index of the slot containing the board." ::= { s5TrPortEntry 1 } s5TrPortIndx OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the port on the board. Its value ranges between 1 and the number of manageable ports on the board." ::= { s5TrPortEntry 2 } s5TrPortWrapStatus OBJECT-TYPE SYNTAX INTEGER { other(1), wrap(2), connect(3), timedWrap(4), nmmBeaconWrap(5), wrongSpeedWrap(6), permBeaconWrap(7), hostBecaonWrap (8) } ACCESS read-write STATUS mandatory DESCRIPTION "The wrap status of the port. The following values can be written: wrap(2)........wrap the port connect(3).....unwrap the port timedWrap(4)...time wrap port (uses value from s5TrPortWrapTime) The following values reflect the wrap status of the port: other(1)............wrap status unknown wrap(2).............port is wrapped connect(3)..........port is not wrapped timedWrap(4)........port is timed wrapped (see value of s5TrPortWrapTime) nmmBeaconWrap(5)....beaconing station automatically removed by an NMM wrongSpeedWrap(6)...station with wrong speed automatically removed permBeaconWrap(7)...station permanently removed by an NMM since it attempted to deinsert and insert in the ring at a high rate while it beacons the ring. On GETs with port status of timeWrap(4), if the time remaining before the wrap is undone is available, it will be reported in object s5TrPortWrapTime as a positive value. If not available, the value of s5TrPortWrapTime will be zero. When changing a port to timedWrap(4), the SET request must also contain the value for object s5TrPortWrapTime. Only value wrap(2) will survive resets of the host card." ::= { s5TrPortEntry 3 } s5TrPortWrapTime OBJECT-TYPE SYNTAX TimeIntervalSec ACCESS read-write STATUS mandatory DESCRIPTION "The length of time to keep the port wrapped when a timed wrap is done to the board. This object can only be written in the same request that sets s5TrPortWrapStatus to timedWrap(4). Afterwards, it indicates the amount of time left before the timed wrap is completed, at which time s5TrPortWrapStatus is changed to connect(3). This object has the value of zero if the port is not timed wrapped, and also if the amount of time is not available." ::= { s5TrPortEntry 4 } s5TrPortInsrtStatus OBJECT-TYPE SYNTAX INTEGER { other(1), notInserted(2), inserted(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The port insertion status. The values are: other(1).........status unknown notInserted(2)...port is not inserted inserted(3)......port inserted into the ring" ::= { s5TrPortEntry 5 } s5TrPortPhanStatus OBJECT-TYPE SYNTAX INTEGER { other(1), noPhantom(2), phantom(3), softwarePhantom(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The port phantom status. The values are: other(1).............status unknown noPhantom(2).........no phantom signal phantom(3)...........phantom signal is on softwarePhantom(4)...phantom signal is on by turning on software insertion (see s5TrPortSoftwareInsertion for more details) Note: for RI/RO ports, this signal is driven by the 'lowlight' detector. For RI/RO ports that have the value of none(3) for s5TrPortTrnkAccMthd, this value will always be phantom(3)." ::= { s5TrPortEntry 6 } s5TrPortPhanChngs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A counter of changes of s5TrPortPhanStatus from noPhantom(2) to phantom(3)." ::= { s5TrPortEntry 7 } s5TrPortTrnkAccMthdStrap OBJECT-TYPE SYNTAX INTEGER { notSupported(1), synoptics(2), none(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The strap (hardware jumper) setting for the RI/RO port trunk validation method. The values are: notSupported(1)...a fiber port, or not a RI/RO port synoptics(2)......use SynOptics method none(3)...........no validation done The operational method used is indicated by the value of s5TrPortTrnkAccMthd." ::= { s5TrPortEntry 8 } s5TrPortTrnkAccMthd OBJECT-TYPE SYNTAX INTEGER { notSupported(1), synoptics(2), none(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The operational setting for the RI/RO port trunk validation method. The following values can be written: synoptics(2)...use SynOptics method none(3)........no validation done The following values can be read: notSupported(1)...not a RI/RO port, or a fiber port synoptics(2)......use SynOptics method none(3)...........do no validation" ::= { s5TrPortEntry 9 } s5TrPortClass OBJECT-TYPE SYNTAX INTEGER { other(1), ri(2), ro(3), lobe(4), internal(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The port class. The values are: other(1)......unknown or some other type ri(2).........Ring In port ro(3).........Ring Out port lobe(4).......Lobe port internal(5)...Internal port which may be connected to a backplane ring" ::= { s5TrPortEntry 10 } s5TrPortMedia OBJECT-TYPE SYNTAX INTEGER { other(1), synFiber(2), stdFiber(3), copperActive(4), copperPassive(5), mac(6), specialProc(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The port media type. The values are: other(1)...........unknown or some other type synFiber(2)........SynOptics Fiber stdFiber(3)........Standard Fiber copperActive(4)....Active copper copperPassive(5)...Passive copper mac(6).............Internal MAC specialProc(7).....Internal special processor" ::= { s5TrPortEntry 11 } s5TrPortConnector OBJECT-TYPE SYNTAX INTEGER { other(1), internal(2), db9(3), rj45(4), fiberST(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The port connector type. The values are: other(1)......unknown or some other type internal(2)...no external connector db9(3)........DB9 rj45(4).......RJ-45 fiberST(5)....fiber ST" ::= { s5TrPortEntry 12 } s5TrPortSoftwareInsertion OBJECT-TYPE SYNTAX INTEGER { notCapableOfSoftwareInsertion(1), capableAndSoftwareInsertionOn(2), capableAndSoftwareInsertionOff(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object reflects the capability for a port to connect to the Ring-In (RI) or Ring-Out (RO) port of a MAU by software controlled phantom insertion. The following values can be read: notCapableOfSoftwareInsertion(1)... The port is incapable of software insertion and therefore cannot connect to the RI or RO port of a MAU capableAndSoftwareInsertionOn(2)... The port is capable of software insertion, and software insertion is on capableAndSoftwareInsertionOff(3)... The port is capable of software insertion, and software insertion is off The following values can be written: capableAndSoftwareInsertionOn(2)... Turns on the software insertion (see note) capableAndSoftwareInsertionOff(3)... Turns off the software insertion (see note) Note: The values capableAndSoftwareInsertionOn(2) and capableAndSoftwareInsertionOff(3) are only valid for writing if the port has the capability of software insertion." ::= {s5TrPortEntry 13} s5TrPortAFD OBJECT-TYPE SYNTAX INTEGER { notCapableOfAFDDisable(1), capableAndAFDEnabled(2), capableAndAFDDisabled(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object reflects the capability for a port to disable AFD, Automatic Frequency Detection. The following values can be read: notCapableOfAFDDisable(1)... The port is incapable of AFD disable. capableAndAFDEnabled(2)... The port is capable of AFD disable and the current AFD is enabled. capableAndAFDDisabled(3)... The port is capable of AFD disable and the current AFD is disabled. The following values can be written: capableAndAFDEnabled(2)... Enable the AFD. capableAndAFDDisabled(3)... Disable the AFD. Note: The values capableAndAFDEnabled(2) and capableAndAFDDisabled(3) are only valid for writing if the port has the capability of AFD disable." ::= {s5TrPortEntry 14} -- FPU Table s5TrFpuTable OBJECT-TYPE SYNTAX SEQUENCE OF S5TrFpuEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing information about each FPU (Frame Processing Unit) on a board." ::= { s5TrCfg 2 } s5TrFpuEntry OBJECT-TYPE SYNTAX S5TrFpuEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row in the Token Ring FPU table. Entries can not be created or deleted via SNMP." INDEX { s5TrFpuBrdIndx, s5TrFpuIndx } ::= { s5TrFpuTable 1 } S5TrFpuEntry ::= SEQUENCE { s5TrFpuBrdIndx INTEGER, s5TrFpuIndx INTEGER, s5TrFpuType INTEGER, s5TrFpuTypeIndx INTEGER, s5TrFpuVer DisplayString, s5TrFpuCapabilites INTEGER, s5TrFpuRunningMode INTEGER } s5TrFpuBrdIndx OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the board. This corresponds to the index of the slot containing the board." ::= { s5TrFpuEntry 1 } s5TrFpuIndx OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the FPU on the board. The value ranges between 1 and the number of FPUs on the board." ::= { s5TrFpuEntry 2 } s5TrFpuType OBJECT-TYPE SYNTAX INTEGER { other(1), cluster(2), port(3), roving(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of FPU. The values are: other(1).....other or unknown cluster(2)...FPU is associated with a cluster port(3)......FPU is associated with a port roving(4)....FPU is a virtual one due to roving embedded management FPU. The type index s5TrFpuTypeIndx specifies port number in this case. This describes at what point an FPU is connected so that it can collect information." ::= { s5TrFpuEntry 3 } s5TrFpuTypeIndx OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the cluster or port that the FPU is associated with. The object s5TrFpuType type specifies the type." ::= { s5TrFpuEntry 4 } s5TrFpuVer OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-only STATUS obsolete DESCRIPTION "The version of the FPU. If not available, then the value is a zero length string." ::= { s5TrFpuEntry 5 } s5TrFpuCapabilites OBJECT-TYPE SYNTAX INTEGER { other(1), coreStatistics(2), embeddedManagement(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The capabilities of the FPU. The values are: other (1)...............Other or unknown coreStatistics(2).......Core statistics FPU embeddedManagement(3)...FPU capable of core statistics and roving; both features are mutually exclusive." ::= { s5TrFpuEntry 6 } s5TrFpuRunningMode OBJECT-TYPE SYNTAX INTEGER { other(1), coreStatistics(2), rovingFPU(4), securityRoving(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The running mode of the FPU. These values are for both read and write with the exception of other(1) which is for read only. The values are: other(1).......................Other or unknown coreStatistics(2)..............FPU running in core statistics mode. roving(4)......................FPU running in roving mode; Note: core statistics is unavailable in this mode. securityRoving(5)..............FPU running in roving mode due to authorized nodes security being turned on." ::= { s5TrFpuEntry 7 } -- Token Ring Extensions to the Chassis MIB s5TrAttTable OBJECT-TYPE SYNTAX SEQUENCE OF S5TrAttEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing information about each Token Ring attachment point on a board. This table extends table s5ChasAttTable for Token Ring Boards." ::= { s5TrCfg 3 } s5TrAttEntry OBJECT-TYPE SYNTAX S5TrAttEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row in Token Ring attachment table. Entries can not be created or deleted via SNMP." INDEX { s5TrAttBrdIndx, s5TrAttIndx } ::= { s5TrAttTable 1 } S5TrAttEntry ::= SEQUENCE { s5TrAttBrdIndx INTEGER, s5TrAttIndx INTEGER, s5TrAttDfltSpeed INTEGER, s5TrAttCurSpeed INTEGER, s5TrAttFault INTEGER } s5TrAttBrdIndx OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the board. This corresponds to the index of the slot containing the board." ::= { s5TrAttEntry 1 } s5TrAttIndx OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the attachment point on the board." ::= { s5TrAttEntry 2 } s5TrAttDfltSpeed OBJECT-TYPE SYNTAX INTEGER { other(1), s4Mbit(2), s16Mbit(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The default speed setting for the attachment point. The values are: other(1).....unknown or other speed s4Mbit(2)....4Mbit s16Mbit(3)...16Mbit" ::= { s5TrAttEntry 3 } s5TrAttCurSpeed OBJECT-TYPE SYNTAX INTEGER { other(1), s4Mbit(2), s16Mbit(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The current speed setting for the attachment point. The read-only value is: other(1).....unknown or other speed The read-write values are: s4Mbit(2)....4Mbit s16Mbit(3)...16Mbit" ::= { s5TrAttEntry 4 } s5TrAttFault OBJECT-TYPE SYNTAX INTEGER { other(1), nofault(2), fault(3) } ACCESS read-only STATUS mandatory DESCRIPTION "A fault indicator for the attachment point. The values are: other(1).....not connected to a backplane network or value is unknown nofault(2)...no fault detected fault(3).....fault detected." ::= { s5TrAttEntry 5 } s5TrBkDiv OBJECT-TYPE SYNTAX INTEGER { other(1), split(2), join(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting of the Token Ring backplane divider. The value that can only be read is: other(1)...unknown or other state Values that can be read and written are: split(2)...split the backplane join(3)....join the backplane" ::= { s5TrCfg 4 } -- Ring Extension Table s5TrRingExt OBJECT IDENTIFIER ::= { s5TrCfg 5 } -- Ring Extension Table Highlight s5TrRingExtLastChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when the last change of any Ring Extension table entry within the chassis was detected." ::= { s5TrRingExt 1} s5TrRingExtCurNum OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The current number of entries in the Ring Extension Table." ::= { s5TrRingExt 2 } -- Ring Extension Table Details s5TrRingExtTable OBJECT-TYPE SYNTAX SEQUENCE OF S5TrRingExtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing information about each RI/RO (Ring In / Ring Out) pair on a board. The number of entries is determined by the number of existing RI/RO pairs. Those boards that do not have any RI/RO do not have any entries in this table." ::= { s5TrRingExt 3 } s5TrRingExtEntry OBJECT-TYPE SYNTAX S5TrRingExtEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row in the Ring Extension table. Entries can not be created or deleted via SNMP." INDEX { s5TrRingExtBoardIndx, s5TrRingExtExtensionIndx } ::= { s5TrRingExtTable 1 } S5TrRingExtEntry ::= SEQUENCE { s5TrRingExtBoardIndx INTEGER, s5TrRingExtExtensionIndx INTEGER, s5TrRingExtRingNumber INTEGER, s5TrRingExtRingInUna MacAddress, s5TrRingExtRingOutUna MacAddress, s5TrRingExtSecUna MacAddress, s5TrRingExtRingInPhanStatus INTEGER, s5TrRingExtRingOutPhanStatus INTEGER, s5TrRingExtRingInWrapStatus INTEGER, s5TrRingExtRingOutWrapStatus INTEGER, s5TrRingExtClusterNumber INTEGER, s5TrRingExtRingInPortNumber INTEGER, s5TrRingExtRingOutPortNumber INTEGER } s5TrRingExtBoardIndx OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the board which has RI/RO. This corresponds to the index of the slot containing the board." ::= { s5TrRingExtEntry 1 } s5TrRingExtExtensionIndx OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the RI/RO extension pair on the board. The value ranges between 1 and the number of RI/RO pairs on the board." ::= { s5TrRingExtEntry 2 } s5TrRingExtRingNumber OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The logical ring number of the ring that RI/RO connects to." ::= { s5TrRingExtEntry 3 } s5TrRingExtRingInUna OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The upstream neighbor address to the Ring In port." ::= { s5TrRingExtEntry 4 } s5TrRingExtRingOutUna OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The upstream neighbor address to the Ring Out port." ::= { s5TrRingExtEntry 5 } s5TrRingExtSecUna OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The (secondary) upstream neighbor address as read by the FPU that is located between RI and RO." ::= { s5TrRingExtEntry 6 } s5TrRingExtRingInPhanStatus OBJECT-TYPE SYNTAX INTEGER { other(1), noPhantom(2), phantom(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The phantom status of the Ring In port. The values are: other(1).........status unknown noPhantom(2).....no phantom signal phantom(3).......phantom signal is on." ::= { s5TrRingExtEntry 7 } s5TrRingExtRingOutPhanStatus OBJECT-TYPE SYNTAX INTEGER { other(1), noPhantom(2), phantom(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The phantom status of the Ring Out port. The values are: other(1).........status unknown noPhantom(2).....no phantom signal phantom(3).......phantom signal is on." ::= { s5TrRingExtEntry 8 } s5TrRingExtRingInWrapStatus OBJECT-TYPE SYNTAX INTEGER { other(1), wrap(2), connect(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The wrap status of the Ring-In port. The values are: other(1)............wrap status unknown wrap(2).............port is wrapped connect(3)..........port is unwrapped" ::= { s5TrRingExtEntry 9 } s5TrRingExtRingOutWrapStatus OBJECT-TYPE SYNTAX INTEGER { other(1), wrap(2), connect(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The wrap status of the Ring-Out port. The values are: other(1)............wrap status unknown wrap(2).............port is wrapped connect(3)..........port is unwrapped" ::= { s5TrRingExtEntry 10 } s5TrRingExtClusterNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The cluster number where RI/RO pair is located on the board." ::= { s5TrRingExtEntry 11 } s5TrRingExtRingInPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The port number where RI is located on the board." ::= { s5TrRingExtEntry 12 } s5TrRingExtRingOutPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The port number where RO is located on the board." ::= { s5TrRingExtEntry 13 } -- Encoded Octet Strings for Ring Extension Table s5TrRingExtEosSize OBJECT-TYPE SYNTAX INTEGER (0..1400) ACCESS read-only STATUS mandatory DESCRIPTION "The current size of a 'row' in the table s5TrRingExtEosTable. This allows applications to be able to break apart 'rows' in the table." ::= { s5TrRingExt 4 } s5TrRingExtEosTable OBJECT-TYPE SYNTAX SEQUENCE OF S5TrRingExtEosEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of encoded octet strings of entries in table s5TrRingExtTable. The number of entries is determined by the packing of 'rows' from s5TrRingExtTable." ::= { s5TrRingExt 5 } s5TrRingExtEosEntry OBJECT-TYPE SYNTAX S5TrRingExtEosEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row in the table of encoded octet strings for table s5TrRingExtTable. Instance returned in Response PDU: On GETs: instance specified is the instance returned. On GET-NEXTs: instance returned is the instance of the last record contained in the octet string. Entries in the table can not be created or deleted via SNMP." INDEX { s5TrRingExtBoardIndx, s5TrRingExtExtensionIndx } ::= { s5TrRingExtEosTable 1 } S5TrRingExtEosEntry ::= SEQUENCE { s5TrRingExtEos OCTET STRING } s5TrRingExtEos OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..1400)) ACCESS read-only STATUS mandatory DESCRIPTION "An encoded octet string. On reads it contains an integral number of 'rows' from table s5TrRingExtTable. All 'rows' are the same size which is defined by object s5TrRingExtEosSize." ::= { s5TrRingExtEosEntry 1 } -- SECTION 3: Statistics -- Basic Statistics Table s5TrBStatTable OBJECT-TYPE SYNTAX SEQUENCE OF S5TrBStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing Token Ring basic statistics. The entries in the table may come from several different data sources including FPUs (Frame Processing Units) and MACs on NMMs (Network Management Modules). The number of entries is determined by the number of sources that can provide the information." ::= { s5TrStat 1 } s5TrBStatEntry OBJECT-TYPE SYNTAX S5TrBStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row in Token Ring basic statistics table. Entries can not be created or deleted via SNMP." INDEX { s5TrBStatSrcIndx } ::= { s5TrBStatTable 1 } S5TrBStatEntry ::= SEQUENCE { s5TrBStatSrcIndx SrcIndx, s5TrBStatTtlOctets Counter, s5TrBStatMacOctets Counter, s5TrBStatLlcOctets Counter, s5TrBStatTtlFrms Counter, s5TrBStatTtlGoodFrms Counter, s5TrBStatTtlBadFrms Counter, s5TrBStatMacFrms Counter, s5TrBStatLlcFrms Counter, s5TrBStatLlcNonUcastFrms Counter, s5TrBStatLlcUcastFrms Counter, s5TrBStatGoodErrReportFrms Counter, s5TrBStatBeaconFrms Counter, s5TrBStatRingPurgeFrms Counter, s5TrBStatClaimTokenFrms Counter, s5TrBStatUna MacAddress } s5TrBStatSrcIndx OBJECT-TYPE SYNTAX SrcIndx ACCESS read-only STATUS mandatory DESCRIPTION "The index of the entry in the table. This index identifies the source of the information. Only those sources that provide these statistics are in this table." ::= { s5TrBStatEntry 1 } s5TrBStatTtlOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets of data in LLC frames and MAC frames (including frames with errors) measured on the ring (excluding framing bits, but including FCS octets)." ::= { s5TrBStatEntry 2 } s5TrBStatMacOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets of data in MAC frames (including frames with errors) measured on the ring (excluding framing bits, but including FCS octets)." ::= { s5TrBStatEntry 3 } s5TrBStatLlcOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets of data in LLC frames (including frames with errors) measured on the ring (excluding framing bits, but including FCS octets)." ::= { s5TrBStatEntry 4 } s5TrBStatTtlFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of LLC frames and MAC frames (including frames with errors) detected on the ring." ::= { s5TrBStatEntry 5 } s5TrBStatTtlGoodFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of LLC frames and MAC frames (excluding frames with errors) detected on the ring." ::= { s5TrBStatEntry 6 } s5TrBStatTtlBadFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of LLC frames and MAC frames with errors detected on the ring." ::= { s5TrBStatEntry 7 } s5TrBStatMacFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of MAC frames (including frames with errors) detected on the ring." ::= { s5TrBStatEntry 8 } s5TrBStatLlcFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of LLC frames (including frames with errors) detected on the ring." ::= { s5TrBStatEntry 9 } s5TrBStatLlcNonUcastFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of LLC frames (including frames with errors) detected on the ring that were directed to a LLC broadcast address (i.e., 0xFFFFFFFFFFFF or 0xC000FFFFFFFF) or a local or global multicast or functional address (i.e., 0xC000xxxxxxxx)." ::= { s5TrBStatEntry 10 } s5TrBStatLlcUcastFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of LLC frames (including frames with errors) detected on the ring that were directed to a LLC unicast address." ::= { s5TrBStatEntry 11 } s5TrBStatGoodErrReportFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Soft error Report frames (excluding frames with errors) detected on the ring." ::= { s5TrBStatEntry 12 } s5TrBStatBeaconFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Beacon frames (including frames with errors) detected on the ring." ::= { s5TrBStatEntry 13 } s5TrBStatRingPurgeFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Ring Purge frames (including frames with errors) detected on the ring." ::= { s5TrBStatEntry 14 } s5TrBStatClaimTokenFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Claim Token frames (including frames with errors) detected on the ring." ::= { s5TrBStatEntry 15 } s5TrBStatUna OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address of the next active upstream neighbor (NAUN) (or upstream neighbor address (UNA)) of the ring monitoring source. If it is unknown or at power reset (for example, no activity on the ring), the value is 00:00:00:00:00:00. The old value of the NAUN will be held, even if the ring becomes inactive (i.e., it will not clear to zero after no activity)." ::= { s5TrBStatEntry 16 } -- Frame Size Statistics Table s5TrFStatTable OBJECT-TYPE SYNTAX SEQUENCE OF S5TrFStatEntry ACCESS not-accessible STATUS obsolete DESCRIPTION "A table containing Token Ring frame size distribution statistics. These statistics are for LLC frames. Counters for frames and octets can be found in the basic statistics table. The entries in this table may come from several different data sources. The number of entries is determined by the number of sources that can provide the information." ::= { s5TrStat 2 } s5TrFStatEntry OBJECT-TYPE SYNTAX S5TrFStatEntry ACCESS not-accessible STATUS obsolete DESCRIPTION "A row in Token Ring frame size distribution statistics table. Entries can not be created or deleted via SNMP." INDEX { s5TrFStatSrcIndx } ::= { s5TrFStatTable 1 } S5TrFStatEntry ::= SEQUENCE { s5TrFStatSrcIndx SrcIndx, s5TrFStatDropEvents Counter, s5TrFStatLlcFrms18to63Octets Counter, s5TrFStatLlcFrms64to127Octets Counter, s5TrFStatLlcFrms128to255Octets Counter, s5TrFStatLlcFrms256to511Octets Counter, s5TrFStatLlcFrms512to1023Octets Counter, s5TrFStatLlcFrms1024to2047Octets Counter, s5TrFStatLlcFrms2048to4095Octets Counter, s5TrFStatLlcFrms4096to8191Octets Counter, s5TrFStatLlcFrms8192to18000Octets Counter, s5TrFStatLlcFrmsGreaterThan18000Octets Counter } s5TrFStatSrcIndx OBJECT-TYPE SYNTAX SrcIndx ACCESS read-only STATUS obsolete DESCRIPTION "The index of the entry in the table. This index identifies the source of the information. Only those sources that provide these statistics are in this table." ::= { s5TrFStatEntry 1 } s5TrFStatDropEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS obsolete DESCRIPTION "The total number of events in which frames were dropped by the data source due to lack of resources. Note that this number is not necessarily the number of frames dropped; it is just the number of times this condition has been detected." ::= { s5TrFStatEntry 2 } s5TrFStatLlcFrms18to63Octets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS obsolete DESCRIPTION "The total number of LLC frames (excluding frames with errors) measured on the ring that were between 18 and 63 octets in length inclusive, excluding framing bits but including FCS octets." ::= { s5TrFStatEntry 3 } s5TrFStatLlcFrms64to127Octets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS obsolete DESCRIPTION "The total number of LLC frames (excluding frames with errors) measured on the ring that were between 64 and 127 octets in length inclusive, excluding framing bits but including FCS octets." ::= { s5TrFStatEntry 4 } s5TrFStatLlcFrms128to255Octets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS obsolete DESCRIPTION "The total number of LLC frames (excluding frames with errors) measured on the ring that were between 128 and 255 octets in length inclusive, excluding framing bits but including FCS octets." ::= { s5TrFStatEntry 5 } s5TrFStatLlcFrms256to511Octets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS obsolete DESCRIPTION "The total number of LLC frames (excluding frames with errors) measured on the ring that were between 256 and 511 octets in length inclusive, excluding framing bits but including FCS octets." ::= { s5TrFStatEntry 6 } s5TrFStatLlcFrms512to1023Octets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS obsolete DESCRIPTION "The total number of LLC frames (excluding frames with errors) measured on the ring that were between 512 and 1023 octets in length inclusive, excluding framing bits but including FCS octets." ::= { s5TrFStatEntry 7 } s5TrFStatLlcFrms1024to2047Octets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS obsolete DESCRIPTION "The total number of LLC frames (excluding frames with errors) measured on the ring that were between 1024 and 2047 octets in length inclusive, excluding framing bits but including FCS octets." ::= { s5TrFStatEntry 8 } s5TrFStatLlcFrms2048to4095Octets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS obsolete DESCRIPTION "The total number of LLC frames (excluding frames with errors) measured on the ring that were between 2048 and 4095 octets in length inclusive, excluding framing bits but including FCS octets." ::= { s5TrFStatEntry 9 } s5TrFStatLlcFrms4096to8191Octets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS obsolete DESCRIPTION "The total number of LLC frames (excluding frames with errors) measured on the ring that were between 4096 and 8191 octets in length inclusive, excluding framing bits but including FCS octets." ::= { s5TrFStatEntry 10 } s5TrFStatLlcFrms8192to18000Octets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS obsolete DESCRIPTION "The total number of LLC frames (excluding frames with errors) measured on the ring that were between 8192 and 18000 octets in length inclusive, excluding framing bits but including FCS octets." ::= { s5TrFStatEntry 11 } s5TrFStatLlcFrmsGreaterThan18000Octets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS obsolete DESCRIPTION "The total number of LLC frames (excluding frames with errors) measured on the ring that were greater than 18000 octets in length, excluding framing bits but including FCS octets." ::= { s5TrFStatEntry 12 } -- Error Statistics Table s5TrEStatTable OBJECT-TYPE SYNTAX SEQUENCE OF S5TrEStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing Token Ring error statistics. The entries in the table may come from several different data sources. The number of entries is determined by the number of sources that can provide the information. (For example, this table is valid only on NMMs when they have become a Ring Error Monitor (REM)." ::= { s5TrStat 3 } s5TrEStatEntry OBJECT-TYPE SYNTAX S5TrEStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row in Token Ring error statistics table. Entries can not be created or deleted via SNMP." INDEX { s5TrEStatSrcIndx } ::= { s5TrEStatTable 1 } S5TrEStatEntry ::= SEQUENCE { s5TrEStatSrcIndx SrcIndx, s5TrEStatDropEvents Counter, s5TrEStatLineErrs Counter, s5TrEStatInternalErrs Counter, s5TrEStatBurstErrs Counter, s5TrEStatACErrs Counter, s5TrEStatAbortErrs Counter, s5TrEStatLostFrameErrs Counter, s5TrEStatCongestionErrs Counter, s5TrEStatFrameCopiedErrs Counter, s5TrEStatFrequencyErrs Counter, s5TrEStatTokenErrs Counter, s5TrEStatSoftErrFrms Counter } s5TrEStatSrcIndx OBJECT-TYPE SYNTAX SrcIndx ACCESS read-only STATUS mandatory DESCRIPTION "The index of the entry in the table. This index identifies the source of the information. Only those sources that provide these statistics are in this table." ::= { s5TrEStatEntry 1 } s5TrEStatDropEvents OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS obsolete DESCRIPTION "Total number of events in which frames were dropped by the data source due to lack of resources. Note that this number is not necessarily the number of frames dropped; it is just the number of times this condition has been detected." ::= { s5TrEStatEntry 2 } s5TrEStatLineErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of line errors reported by all stations in error report frames and detected on the ring. Section 3.8.1 of IEEE 802.5 specification." ::= { s5TrEStatEntry 3 } s5TrEStatInternalErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of adapter internal errors reported by all stations in error report frames and detected on the ring. Section 3.8.2 of IEEE 802.5 specification." ::= { s5TrEStatEntry 4 } s5TrEStatBurstErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of burst errors reported by all stations in error report frames and detected on the ring. Section 3.8.3 of IEEE 802.5 specification." ::= { s5TrEStatEntry 5 } s5TrEStatACErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of AC (Address Copied) errors reported by all stations in error report frames and detected on the ring. Section 3.8.4 of IEEE 802.5 specification." ::= { s5TrEStatEntry 6 } s5TrEStatAbortErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of abort delimiter transmitted errors reported by all stations in error report frames and detected on the ring. Section 3.8.5 of IEEE 802.5 specification." ::= { s5TrEStatEntry 7 } s5TrEStatLostFrameErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of frames lost errors reported by all stations in error report frames and detected on the ring. Section 3.8.6 of IEEE 802.5 specification." ::= { s5TrEStatEntry 8 } s5TrEStatCongestionErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of receive congestion errors reported by all stations in error report frames and detected on the ring. Section 3.8.7 of IEEE 802.5 specification." ::= { s5TrEStatEntry 9 } s5TrEStatFrameCopiedErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of frame copied errors reported by all stations in error report frames and detected on the ring. Section 3.8.8 of IEEE 802.5 specification." ::= { s5TrEStatEntry 10 } s5TrEStatFrequencyErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of frequency errors reported by all stations in error report frames and detected on the ring. Section 3.8.9 of IEEE 802.5 specification." ::= { s5TrEStatEntry 11 } s5TrEStatTokenErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of token errors reported by all stations in error report frames and detected on the ring. Section 3.8.10 of IEEE 802.5 specification." ::= { s5TrEStatEntry 12 } s5TrEStatSoftErrFrms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of error report frames detected on the ring. (Note: this has the same count as object s5TrBStatGoodErrReportFrms.)" ::= { s5TrEStatEntry 13 } -- Port Information Table s5TrPortInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF S5TrPortInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing information for each managed token ring connectivity port on a board, excluding ring in, ring out, and those used as cascade expansion. The number of entries is determined by the number of manageable ports and the number of occupied slots in s5ChasComTable whose s5ChasComType is of a token Ring type and is on the same backplane ring as the NMM interface." ::= { s5TrCfg 6 } s5TrPortInfoEntry OBJECT-TYPE SYNTAX S5TrPortInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row in the port information table. Entries can not be created or deleted via SNMP." INDEX { s5TrPortInfoSrcIndx, s5TrPortInfoBrdIndx, s5TrPortInfoPortIndx } ::= { s5TrPortInfoTable 1 } S5TrPortInfoEntry ::= SEQUENCE { s5TrPortInfoSrcIndx SrcIndx, s5TrPortInfoBrdIndx INTEGER, s5TrPortInfoPortIndx INTEGER, s5TrPortInfoAddr MacAddress, s5TrPortInfoLastNaun MacAddress, s5TrPortInfoStationStatus INTEGER, s5TrPortInfoFirstEnterTime TimeTicks, s5TrPortInfoLastEnterTime TimeTicks, s5TrPortInfoLastExitTime TimeTicks, s5TrPortInfoDupAddrErrs Counter, s5TrPortInfoLineErrs Counter, s5TrPortInfoInternalErrs Counter, s5TrPortInfoBurstErrs Counter, s5TrPortInfoACErrs Counter, s5TrPortInfoAbortErrs Counter, s5TrPortInfoLostFrameErrs Counter, s5TrPortInfoCongestionErrs Counter, s5TrPortInfoFrameCopiedErrs Counter, s5TrPortInfoFrequencyErrs Counter, s5TrPortInfoTokenErrs Counter, s5TrPortInfoBeaconErrs Counter, s5TrPortInfoInsertions Counter } s5TrPortInfoSrcIndx OBJECT-TYPE SYNTAX SrcIndx ACCESS read-only STATUS mandatory DESCRIPTION "This index identifies the source of the information. Only those sources that provide these statistics are in this table." ::= { s5TrPortInfoEntry 1 } s5TrPortInfoBrdIndx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the board. This corresponds to the index of the slot containing the board." ::= { s5TrPortInfoEntry 2 } s5TrPortInfoPortIndx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the port on the board. Its value ranges between 1 and the number of manageable ports on the board." ::= { s5TrPortInfoEntry 3 } s5TrPortInfoAddr OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address of the station currently/last attached to the port. If no station in the ring can be found attached to the port, the address should be 0" ::= { s5TrPortInfoEntry 4 } s5TrPortInfoLastNaun OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address of the last known NAUN (Next Active Upstream Neighbor) of the station currently/last attached to the port." ::= { s5TrPortInfoEntry 5 } s5TrPortInfoStationStatus OBJECT-TYPE SYNTAX INTEGER { active(1), notInRingPoll(2), inactive(3), forcedRemoval(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The insertion status of the station currently/last attached to the port. The values are: active(1)..........Actively participating in ring poll from this port notInRingPoll(2)...Detected on the ring, but not currently participating in the ring poll from this port inactive(3)........ No longer on the ring from this port forcedRemoval(4)... forced off the ring from this port by network management." ::= { s5TrPortInfoEntry 6 } s5TrPortInfoFirstEnterTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when this port first time entered the ring. If the time is unknown, the value shall be zero." ::= { s5TrPortInfoEntry 7 } s5TrPortInfoLastEnterTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when this port last time entered the ring. If the time is unknown, the value shall be zero." ::= { s5TrPortInfoEntry 8 } s5TrPortInfoLastExitTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when this port last exited the ring. If the time is unknown, the value shall be zero." ::= { s5TrPortInfoEntry 9 } s5TrPortInfoDupAddrErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of duplicate address error detected from this port." ::= { s5TrPortInfoEntry 10} s5TrPortInfoLineErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of line errors detected from this port." ::= { s5TrPortInfoEntry 11 } s5TrPortInfoInternalErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of adapter internal errors detected from this port. " ::= { s5TrPortInfoEntry 12 } s5TrPortInfoBurstErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of burst errors detected from this port. " ::= { s5TrPortInfoEntry 13 } s5TrPortInfoACErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of AC (Address Copied) errors detected from this port. " ::= { s5TrPortInfoEntry 14 } s5TrPortInfoAbortErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of abort delimiter transmitted errors detected from this port." ::= { s5TrPortInfoEntry 15 } s5TrPortInfoLostFrameErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of lost frame errors detected from this port. " ::= { s5TrPortInfoEntry 16 } s5TrPortInfoCongestionErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of receive congestion errors detected from this port ." ::= { s5TrPortInfoEntry 17 } s5TrPortInfoFrameCopiedErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of frame copied errors detected from this port." ::= { s5TrPortInfoEntry 18 } s5TrPortInfoFrequencyErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of frequency errors detected from this port." ::= { s5TrPortInfoEntry 19 } s5TrPortInfoTokenErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of token errors detected from this port." ::= { s5TrPortInfoEntry 20 } s5TrPortInfoBeaconErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of beacon frames detected from this port." ::= { s5TrPortInfoEntry 21 } s5TrPortInfoInsertions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of times that the port was detected inserting into the ring." ::= { s5TrPortInfoEntry 22 } -- Port FPU Statistics table s5TrPortFpuStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF S5TrPortFpuStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing FPU statistics information for each managed token ring connectivity port on a board. " ::= { s5TrCfg 7 } s5TrPortFpuStatsEntry OBJECT-TYPE SYNTAX S5TrPortFpuStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row in the Port FPU statistics table. Entries can not be created or deleted via SNMP. " INDEX { s5TrPortFpuStatsBrdIndx, s5TrPortFpuStatsPortIndx } ::= { s5TrPortFpuStatsTable 1 } S5TrPortFpuStatsEntry ::= SEQUENCE { s5TrPortFpuStatsBrdIndx INTEGER, s5TrPortFpuStatsPortIndx INTEGER, s5TrPortFpuStatsAddr MacAddress, s5TrPortFpuStatsTxOctets Counter, s5TrPortFpuStatsTxPkts Counter, s5TrPortFpuStatsRxOctets Counter, s5TrPortFpuStatsRxPkts Counter } s5TrPortFpuStatsBrdIndx OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the board. This corresponds to the index of the slot containing the board." ::= { s5TrPortFpuStatsEntry 1 } s5TrPortFpuStatsPortIndx OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the port on the board. The value ranges between 1 and the number of manageable ports on the board." ::= { s5TrPortFpuStatsEntry 2 } s5TrPortFpuStatsAddr OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address of the station currently/last attached to the port. For ring in, ring out and cascade expansion ports, this MAC address is the UNA (Upstream Neighbor Address) as seen by the port. If no station has ever been connected to this port, the address should be zero." ::= { s5TrPortFpuStatsEntry 3 } s5TrPortFpuStatsTxOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of octets transmitted at this port. If no station is connected to the port, the counter should return the last collected value." ::= { s5TrPortFpuStatsEntry 4 } s5TrPortFpuStatsTxPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of packets transmitted at this port. If no station is connected to the port, the counter should return the last collected value." ::= { s5TrPortFpuStatsEntry 5 } s5TrPortFpuStatsRxOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of octets received at this port. If no station is connected to the port, the counter should return the last collected value." ::= { s5TrPortFpuStatsEntry 6 } s5TrPortFpuStatsRxPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets receive at this port. If no station is connected to the port, the counter should return the last collected value." ::= { s5TrPortFpuStatsEntry 7 } END