-- **************************************************************************** -- -- Rack & Power Manager - (RPM) MIB -- Management Information Base for SNMP Network Management -- -- -- Copyright 2001,2003 Hewlett-Packard Development Company, L.P. -- -- Hewlett-Packard Company shall not be liable for technical or -- editorial errors or omissions contained herein. The information in -- this document is provided "as is" without warranty of any kind and -- is subject to change without notice. The warranties for HP products -- are set forth in the express limited warranty statements -- accompanying such products. Nothing herein should be construed as -- constituting an additional warranty. -- -- Confidential computer software. Valid license from HP required for -- possession, use or copying. Consistent with FAR 12.211 and 12.212, -- Commercial Computer Software, Computer Software Documentation, and -- Technical Data for Commercial Items are licensed to the U.S. -- Government under vendor's standard commercial license. -- -- Refer to the READMIB.RDM file for more information about the -- organization of the information in the Compaq Enterprise. -- -- The Compaq Enterprise number is 232. -- The ASN.1 prefix to, and including the Compaq Enterprise is: -- 1.3.6.1.4.1.232 -- -- -- The Compaq Enterprise number is 232. -- The ASN.1 prefix to, and including the Compaq Enterprise is: -- 1.3.6.1.4.1.232 -- -- MIB Version 1.7 -- -- ********************************************************************* CPQRPM-MIB DEFINITIONS ::= BEGIN IMPORTS compaq FROM CPQHOST-MIB DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 sysName FROM RFC1213-MIB; -- compaq OBJECT IDENTIFIER ::= { enterprises 232 } cpqRPM OBJECT IDENTIFIER ::= { compaq 154 } cpqRPMTrapInfo OBJECT IDENTIFIER ::= { cpqRPM 1 } cpqRPMTraps OBJECT IDENTIFIER ::= { cpqRPM 2 } cpqPMTraps OBJECT IDENTIFIER ::= { cpqRPM 3 } --*************************************************************************** --CRPM Trap Info --*************************************************************************** --cpqRPMTrapInfo-group cpqRPMTrapDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Text description of the event that caused the trap." ::= { cpqRPMTrapInfo 1 } cpqRPMTrapDeviceId OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "A unique numeric identifier for the device that caused the trap." ::= { cpqRPMTrapInfo 2 } cpqRPMTrapDeviceName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..50)) ACCESS read-only STATUS mandatory DESCRIPTION "The text name for the device." ::= { cpqRPMTrapInfo 3 } cpqRPMTrapDeviceAddress OBJECT-TYPE SYNTAX DisplayString (SIZE (0..50)) ACCESS read-only STATUS mandatory DESCRIPTION "The hostname or ip address for the device." ::= { cpqRPMTrapInfo 4 } cpqRPMTrapType OBJECT-TYPE SYNTAX INTEGER { system(1), event(2), change(3), power(4), environment(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the type of the event that caused the trap." ::= { cpqRPMTrapInfo 5 } cpqRPMTrapSeverity OBJECT-TYPE SYNTAX INTEGER { unknown(1), information(2), normal(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the severity of the event that caused the trap." ::= { cpqRPMTrapInfo 6 } cpqRPMTrapCode OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "A unique identifier for the alarm." ::= { cpqRPMTrapInfo 7 } cpqRPMTrapURL OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The URL for the management software." ::= { cpqRPMTrapInfo 8 } --**************************************************************************** --Traps -- Device-Traps cpqRPMTrapDeviceConnected TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting a Connection Lost due to one of the following. 1. The serial cable connected to the UPS has been unplugged. 2. The Network cable connected to the UPS has been unplugged. Recommendations: 1. Insure all cables are seated properly. 2. check you network to insure it is functioning properly. 3. If the UPS is serially connected insure that the Serial Relay Agent is installed and running." --#TYPE "Device Connected (1)" --#SEVERITY INFORMATIONAL --#CATEGORY "APPLICATION" ::= 1 cpqRPMTrapConnectionLost TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting a Connection Lost due to one of the following. 1. The serial cable connected to the UPS has been unplugged. 2. The Network cable connected to the UPS has been unplugged. Recommendations: 1. Insure all cables are seated properly. 2. check you network to insure it is functioning properly. 3. If the UPS is serially connected insure that the Serial Relay Agent is installed and running." --#TYPE "Connection Lost (2)" --#SEVERITY CRITICAL --#CATEGORY "APPLICATION" ::= 2 cpqRPMTrapLookupFailed TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "CRPM failed to find an IP address for the device hostname." --#TYPE "DNS Lookup Failed (3)" --#SEVERITY CRITICAL --#CATEGORY "APPLICATION" ::= 3 cpqRPMTrapConnectionFailed TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "CRPM failed to connect to a device." --#TYPE "Connection Failed (4)" --#SEVERITY CRITICAL --#CATEGORY "APPLICATION" ::= 4 cpqRPMTrapDeviceSettingsChanged TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "Device settings have been changed by a user." --#TYPE "Device Settings Changed (5)" --#SEVERITY MINOR --#CATEGORY "APPLICATION" ::= 5 --**************************************************************************** -- CMC-Traps cpqRPMTrapCMCTemp1BelowMin TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting temperature 1 below minimum threshold." --#TYPE "CMC Temperature 1 Below Minimum (10001)" --#SEVERITY MAJOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10001 cpqRPMTrapCMCTemp1AboveWarn TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting temperature 1 above warning threshold." --#TYPE "CMC Temperature 1 Above Warning (10002)" --#SEVERITY MINOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10002 cpqRPMTrapCMCTemp1AboveMax TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting temperature 1 above maximum threshold." --#TYPE "CMC Temperature 1 Above Maximum (10003)" --#SEVERITY MAJOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10003 cpqRPMTrapCMCTemp1Normal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting temperature 1 has returned to a normal temperature." --#TYPE "CMC Temperature 1 Normal (10004)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10004 cpqRPMTrapCMCTemp2BelowMin TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting temperature 2 below minimum threshold." --#TYPE "CMC Temperature 2 Below Minimum (10005)" --#SEVERITY MAJOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10005 cpqRPMTrapCMCTemp2AboveWarn TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting temperature 2 above warning threshold." --#TYPE "CMC Temperature 2 Above Warning (10006)" --#SEVERITY MINOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10006 cpqRPMTrapCMCTemp2AboveMax TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting temperature 2 above maximum threshold." --#TYPE "CMC Temperature 2 Above Maximum (10007)" --#SEVERITY MAJOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10007 cpqRPMTrapCMCTemp2Normal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting temperature 2 has returned to a normal temperature." --#TYPE "CMC Temperature 2 Normal (10008)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10008 cpqRPMTrapCMCVoltUnder TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting voltage below minimum threshold." --#TYPE "CMC Voltage Below Minimum (10011)" --#SEVERITY MAJOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10011 cpqRPMTrapCMCVoltOver TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting voltage above maximum threshold." --#TYPE "CMC Voltage Above Maximum (10012)" --#SEVERITY MAJOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10012 cpqRPMTrapCMCVoltNormal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting voltage has returned to normal." --#TYPE "CMC Voltage Normal (10013)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10013 cpqRPMTrapCMCHmdtUnder TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting humidity below minimum threshold." --#TYPE "CMC Humidity Below Minimum (10021)" --#SEVERITY MAJOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10021 cpqRPMTrapCMCHmdtOver TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting humidity above maximum threshold." --#TYPE "CMC Humidity Above Maximum (10022)" --#SEVERITY MAJOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10022 cpqRPMTrapCMCHmdtNormal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting humidity has returned to normal." --#TYPE "CMC Humidity Normal (10023)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10023 cpqRPMTrapCMCSmokeDetected TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting smoke detected." --#TYPE "CMC Smoke Detected (10031)" --#SEVERITY MAJOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10031 cpqRPMTrapCMCSmokeCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting smoke cleared." --#TYPE "CMC Smoke Cleared (10032)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10032 cpqRPMTrapCMCShockDetected TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting shock detected." --#TYPE "CMC Shock Detected (10041)" --#SEVERITY MAJOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10041 cpqRPMTrapCMCShockCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting shock cleared." --#TYPE "CMC Shock Cleared (10042)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10042 cpqRPMTrapCMCAux1Alarm TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device has entered an alarm condition for auxiliary input 1." --#TYPE "CMC Aux 1 Alarm (10051)" --#SEVERITY MINOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10051 cpqRPMTrapCMCAux1Cleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting auxiliary input 1 alarm cleared." --#TYPE "CMC Aux 1 Alarm Cleared (10052)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10052 cpqRPMTrapCMCAux2Alarm TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device has entered an alarm condition for auxiliary input 2." --#TYPE "CMC Aux 2 Alarm (10053)" --#SEVERITY MINOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10053 cpqRPMTrapCMCAux2Cleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting auxiliary input 2 alarm cleared." --#TYPE "CMC Aux 2 Alarm Cleared (10054)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10054 cpqRPMTrapCMCInput1Opened TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting input 1 has been opened." --#TYPE "CMC Input 1 Opened (10101)" --#SEVERITY MINOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10101 cpqRPMTrapCMCInput1Closed TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting input 1 has been closed." --#TYPE "CMC Input 1 Closed (10102)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10102 cpqRPMTrapCMCInput2Opened TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting input 2 has been opened." --#TYPE "CMC Input 2 Opened (10103)" --#SEVERITY MINOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10103 cpqRPMTrapCMCInput2Closed TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting input 2 has been closed." --#TYPE "CMC Input 2 Closed (10104)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10104 cpqRPMTrapCMCInput3Opened TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting input 3 has been opened." --#TYPE "CMC Input 3 Opened (10105)" --#SEVERITY MINOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10105 cpqRPMTrapCMCInput3Closed TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting input 3 has been closed." --#TYPE "CMC Input 3 Closed (10106)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10106 cpqRPMTrapCMCInput4Opened TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting input 4 has been opened." --#TYPE "CMC Input 4 Opened (10107)" --#SEVERITY MINOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10107 cpqRPMTrapCMCInput4Closed TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting input 4 has been closed." --#TYPE "CMC Input 4 Closed (10108)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10108 cpqRPMTrapCMCLockset1Unlocked TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting lockset 1 has been unlocked." --#TYPE "CMC Lockset 1 Unlocked (10111)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10111 cpqRPMTrapCMCLockset1FailedToLock TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting lockset 1 has failed to lock." --#TYPE "Lockset 1 Failed To Lock (10112)" --#SEVERITY MAJOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10112 cpqRPMTrapCMCLockset1Error TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting an error with lockset 1." --#TYPE "CMC Lockset 1 Error (10113)" --#SEVERITY MAJOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10113 cpqRPMTrapCMCLockset1Locked TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting lockset 1 has been locked." --#TYPE "CMC Lockset 1 Locked (10114)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10114 cpqRPMTrapCMCLockset2Unlocked TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting lockset 2 has been unlocked." --#TYPE "CMC Lockset 2 Unlocked (10116)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10116 cpqRPMTrapCMCLockset2FailedToLock TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting lockset 2 has failed to lock." --#TYPE "CMC Lockset 2 Failed To Lock (10117)" --#SEVERITY MAJOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10117 cpqRPMTrapCMCLockset2Error TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting an error with lockset 2." --#TYPE "CMC Lockset 2 Error (10118)" --#SEVERITY MAJOR --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10118 cpqRPMTrapCMCLockset2Locked TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting lockset 2 has been locked." --#TYPE "CMC Lockset 2 Locked (10119)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10119 cpqRPMTrapCMCLockset1Normal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting lockset 2 is normal." --#TYPE "CMC Lockset 2 Normal (10134)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10134 cpqRPMTrapCMCLockset2Normal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A CMC device is reporting lockset 2 is normal." --#TYPE "CMC Lockset 2 Normal (10135)" --#SEVERITY INFORMATIONAL --#CATEGORY "SYSTEM AND ENVIRONMENTAL" ::= 10135 --**************************************************************************** -- UPS-Traps cpqRPMTrapUPSInputVoltageBelowMin TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "A UPS device is reporting input voltage below minimum threshold." --#TYPE "UPS Input Voltage Below Minimum (20001)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 20001 cpqRPMTrapUPSInputVoltageAboveMax TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "A UPS device is reporting input voltage above maximum threshold." --#TYPE "UPS Input Voltage Above Maximum (20002)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 20002 cpqRPMTrapUPSInputVoltageNormal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting input voltage is out of range. Recommendations: 1. Check to make sure the UPS is plugged into an outlet supplied with utility power. 2. If the UPS remains on battery for an extended period of time it will not be able to sustain the load." --#TYPE "UPS Input Voltage Normal (20003)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 20003 cpqRPMTrapUPSOutputVoltageBelowMin TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "A UPS device is reporting output voltage below minimum threshold." --#TYPE "UPS Output Voltage Below Minimum (20011)" --#SEVERITY MINOR --#CATEGORY "UPS" ::= 20011 cpqRPMTrapUPSOutputVoltageAboveMax TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "A UPS device is reporting output voltage above maximum threshold." --#TYPE "UPS Output Voltage Above Maximum (20012)" --#SEVERITY MINOR --#CATEGORY "UPS" ::= 20012 cpqRPMTrapUPSOutputVoltageNormal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting output voltage is out of Range. Recommendations: 1. Initiate a UPS self test. 2. If this error persists contact technical support." --#TYPE "UPS Output Voltage Normal (21020)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 21020 cpqRPMTrapUPSOutputOverload TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting an overload condition. Recommendations: 1. Reduce the load on the UPS by moving some of the load to another UPS. 2. Consider moving to a larger UPS to support the current load." --#TYPE "UPS Output Overload (20014)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 20014 cpqRPMTrapUPSOutputOverloadCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting an overload condition. Recommendations: 1. Reduce the load on the UPS by moving some of the load to another UPS. 2. Consider moving to a larger UPS to support the current load." --#TYPE "UPS Output Overload Cleared (20015)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 20015 cpqRPMTrapUPSBatteryLow TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting low battery. Recommendations: 1. Check to make sure the UPS is plugged into an outlet supplied with utility power. 2. When utility power is restored, charge the battery to it's full capacity. If the battery level continues to decrease, the UPS will not be able to sustain the output load!" --#TYPE "UPS Battery Low (21055)" --#SEVERITY CRITICAL --#CATEGORY "UPS" ::= 21055 cpqRPMTrapUPSBatteryLowCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting low battery. Recommendations: 1. Check to make sure the UPS is plugged into an outlet supplied with utility power. 2. When utility power is restored, charge the battery to it's full capacity. If the battery level continues to decrease, the UPS will not be able to sustain the output load!" --#TYPE "UPS Battery Low Cleared (21056)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 21056 cpqRPMTrapUPSBatteryDepleted TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "A UPS device is a depleted battery." --#TYPE "UPS Depleted Battery (20022)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 20022 cpqRPMTrapUPSBatteryLevelNormal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting low battery. Recommendations: 1. Check to make sure the UPS is plugged into an outlet supplied with utility power. 2. When utility power is restored, charge the battery to it's full capacity. If the battery level continues to decrease, the UPS will not be able to sustain the output load!" --#TYPE "UPS Battery Level Normal (20023)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 20023 cpqRPMTrapUPSOnBattery TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting on battery condition. Recommendations: 1. Check to make sure the UPS is plugged into an outlet supplied with utility power. If the UPS remains on battery for an extended time it will not be able to sustain the output load!" --#TYPE "UPS On Battery (21063)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 21063 cpqRPMTrapUPSOnBypass TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "A UPS device is being bypassed." --#TYPE "UPS On Bypass (20032)" --#SEVERITY MINOR --#CATEGORY "UPS" ::= 20032 cpqRPMTrapUPSOnBuck TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "A UPS device is reporting an On Buck condition due to the following. 1. Utility power has increased above recommended utility input levels. Recommendation: 1. Contact an electrician." --#TYPE "UPS On Buck (21029)" --#SEVERITY MINOR --#CATEGORY "UPS" ::= 21029 cpqRPMTrapUPSOnBoost TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "A UPS device is reporting an On Boost condition due to the following. 1. Utility power has dropped below recommended utility input levels. Recommendation: 1. Contact an electrician." --#TYPE "UPS On Boost (21031)" --#SEVERITY MINOR --#CATEGORY "UPS" ::= 21031 cpqRPMTrapUPSOnUtilityPower TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting on battery condition. Recommendations: 1. Check to make sure the UPS is plugged into an outlet supplied with utility power. If the UPS remains on battery for an extended time it will not be able to sustain the output load!" --#TYPE "UPS On Utility Power (21064)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 21064 cpqRPMTrapUPSTemperatureLow TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "A UPS device is reporting temperature blow minimum threshold." --#TYPE "UPS Temperature Low (20101)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 20101 cpqRPMTrapUPSTemperatureHigh TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "A UPS device is reporting temperature above maximum threshold." --#TYPE "UPS Temperature High (20102)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 20102 cpqRPMTrapUPSTemperatureNormal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting temperature is out of range. Recommendations: 1. Check to make sure the UPS is in a well ventilated area. 2. Lower the ambient temperature in the area where the UPS is located." --#TYPE "UPS Temperature Normal (20103)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 20103 cpqRPMTrapUPSInternalFailure TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting a general UPS failure. Recommendations: 1. Initiate a UPS self test. 2. If this error persists contact technical support." --#TYPE "UPS Internal Failure (20111)" --#SEVERITY CRITICAL --#CATEGORY "UPS" ::= 20111 cpqRPMTrapUPSInternalFailureCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting a general UPS failure. Recommendations: 1. Initiate a UPS self test. 2. If this error persists contact technical support." --#TYPE "UPS Internal Failure Cleared (20112)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 20112 cpqRPMTrapUPSBatteryFailure TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting a battery failure. Recommendations: 1. Initiate a UPS self test. 2. If this error persists contact technical support. 3. Your battery may need to be replaced. The UPS may not be capable of supporting it's load if utility power fails!" --#TYPE "UPS Battery Failure (20121)" --#SEVERITY CRITICAL --#CATEGORY "UPS" ::= 20121 cpqRPMTrapUPSBatteryFailureCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting a battery failure. Recommendations: 1. Initiate a UPS self test. 2. If this error persists contact technical support. 3. Your battery may need to be replaced. The UPS may not be capable of supporting it's load if utility power fails!" --#TYPE "UPS Battery Failure Cleared (20122)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 20122 cpqRPMTrapUPSDiagnosticTestFailed TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "A UPS device is reporting a diagnostic test failed. Recommendations: 1. Your battery may need to be replaced. 2. If this error persists contact technical support. 3. The UPS may not be capable of supporting it's load if utility power fails!" --#TYPE "UPS Diagnostic Test Failed (20131)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 20131 cpqRPMTrapUPSDiagnosticTestSucceeded TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "A UPS device is reporting a diagnostic test failed. Recommendations: 1. Your battery may need to be replaced. 2. If this error persists contact technical support. 3. The UPS may not be capable of supporting it's load if utility power fails!" --#TYPE "UPS Diagnostic Test Succeeded (20132)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 20132 cpqRPMTrapUPSInputUnderOverFreq TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "Input (Utility) fault: measured input frequency is outside of either the upper or lower frequency limit specification for normal operation." --#TYPE "Input Under Or Over Frequency (20141)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 20141 cpqRPMTrapUPSInputUnderOverFreqCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "Measured input frequency is normal" --#TYPE "Input Frequency Normal (20142)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 20142 cpqRPMTrapUPSDCStartOccurred TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "The UPS has been started on battery when AC input power is not present. This alarm is used to record the date and time of this event." --#TYPE "DC Start Occurred (29998)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 29998 cpqRPMTrapUPSDCStartOccurredCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "The UPS has been started on utility while AC input power is present." --#TYPE "DC Start Occurred Cleared (29999)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 29999 cpqRPMTrapUPSBypassNotAvailable TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting bypass not avaliable. Recommendations: 1. Initiate a UPS self test. 2. If this error persists contact technical support." --#TYPE "Bypass Not Available (20161)" --#SEVERITY MINOR --#CATEGORY "UPS" ::= 20161 cpqRPMTrapUPSBypassNotAvailableCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting bypass not avaliable. Recommendations: 1. Initiate a UPS self test. 2. If this error persists contact technical support." --#TYPE "Bypass Not Available Cleared (20162)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 20162 cpqRPMTrapUPSUtilityFail TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "Indicates that the utility input power is not within predetermined limits. This could be, but is not limited to, over voltage, under voltage, over frequency, under frequency or over current." --#TYPE "Utility Fail (20171)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 20171 cpqRPMTrapUPSUtilityFailCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "Indicates that the utility input power is within predetermined limits." --#TYPE "Utility Fail Cleared (20172)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 20172 cpqRPMTrapUPSUtilityNotPresent TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "Indicates that the utility input is not present. This differs from alarm #57 in that the detected voltage is zero in this case." --#TYPE "Utility Not Present (20181)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 20181 cpqRPMTrapUPSUtilityNotPresentCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "Indicates that the utility input is present." --#TYPE "Utility Not Present Cleared (20182)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 20182 cpqRPMTrapUPSBypassManualTurnedOn TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "The bypass has been given a manual turn on command." --#TYPE "Bypass Manual Turned On (20191)" --#SEVERITY MINOR --#CATEGORY "UPS" ::= 20191 cpqRPMTrapUPSBypassManualTurnedOff TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "The bypass has been given a manual turn off command." --#TYPE "Bypass Manual Turned Off (20192)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 20192 cpqRPMTrapUPSSiteWiringFault TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting a fault in the input wiring, other than Phase Rotation: e.g., Ground/Neutral reversed. Recommendations: 1. Contact an electrician." --#TYPE "Site Wiring Fault (20201)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 20201 cpqRPMTrapUPSSiteWiringNormal TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting a fault in the input wiring, other than Phase Rotation: e.g., Ground/Neutral reversed. Recommendations: 1. Contact an electrician." --#TYPE "Site Wiring Fault Cleared (20202)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 20202 cpqRPMtrapUPSBypassOffManual TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is operating in manual bypass mode. Recommendations: 1. In bypass mode, the UPS cannot support devices if there is a power failure. 2. Once maintenance has been performed return the UPS to normal mode." --#TYPE "The UPS is no longer on manual bypass (21060)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 21060 cpqRPMtrapUPSBypassONManual TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is operating in manual bypass mode. Recommendations: 1. In bypass mode, the UPS cannot support devices if there is a power failure. 2. Once maintenance has been performed return the UPS to normal mode." --#TYPE "The UPS is on manual bypass (21059)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 21059 cppqRPMtrapUPSStartedOnBatteryCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device has been started while on battery power. AC input power is not present. Recommendations: 1. Check to make sure the UPS is plugged into an outlet supplied with utility power. If the UPS remains on battery for an extended time it will not be able to sustain the output load!" --#TYPE "Utility power has been restored (20152)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 20152 cppqRPMtrapUPSStartedOnBattery TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device has been started while on battery power. AC input power is not present. Recommendations: 1. Check to make sure the UPS is plugged into an outlet supplied with utility power. If the UPS remains on battery for an extended time it will not be able to sustain the output load." --#TYPE "The UPS was started without utility power (20151)" --#SEVERITY MINOR --#CATEGORY "UPS" ::= 20151 cpqRPMtrapUPSInputOutofRangeCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting input voltage is out of range. Recommendations: 1. Check to make sure the UPS is plugged into an outlet supplied with utility power. 2. If the UPS remains on battery for an extended period of time it will not be able to sustain the load." --#TYPE "Input voltage is normal (21022)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 21022 cpqRPMtrapUPSInputOutofRange TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting input voltage is out of range. Recommendations: 1. Check to make sure the UPS is plugged into an outlet supplied with utility power. 2. If the UPS remains on battery for an extended period of time it will not be able to sustain the load." --#TYPE "Input voltage is out of range (21021)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 21021 cpqRPMtrapUPSTemperatureOutOfRange TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting temperature is out of range. Recommendations: 1. Check to make sure the UPS is in a well ventilated area. 2. Lower the ambient temperature in the area where the UPS is located." --#TYPE "UPS temperature out of range (21007)" --#SEVERITY CRITICAL --#CATEGORY "UPS" ::= 21007 cpqRPMtrapUPSTemperatureOutOfRangeCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting temperature is out of range. Recommendations: 1. Check to make sure the UPS is in a well ventilated area. 2. Lower the ambient temperature in the area where the UPS is located." --#TYPE "UPS temperature has returned to normal (21008)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 21008 cpqRPMtrapUPSBypassOnAuto TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is operating in auto bypass mode. Recommendations: 1. In bypass mode, the UPS cannot support devices if there is a power failure. 2. Once maintenance has been performed return the UPS to normal mode." --#TYPE "The UPS is on automatic bypass (21047)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 21047 cpqRPMtrapUPSBypassOnAutoCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is operating in auto bypass mode. Recommendations: 1. In bypass mode, the UPS cannot support devices if there is a power failure. 2. Once maintenance has been performed return the UPS to normal mode." --#TYPE "The UPS is no longer on auto bypass (21048)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 21048 cpqRPMtrapUPSOutputoutofRange TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting output voltage is out of Range. Recommendations: 1. Initiate a UPS self test. 2. If this error persists contact technical support." --#TYPE "Output voltage is out of range (21019)" --#SEVERITY CRITICAL --#CATEGORY "UPS" ::= 21019 cpqRPMTrapUPSBatteriesDisconnected TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting batteries are not connected to the UPS. Recomendations: 1. Connect the UPS Batteries. The UPS will not be capable of supporting it's load if the utility power fails!" --#TYPE "One or more UPS batteries have been disconnected. (21053)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 21053 cpqRPMTrapUPSBatteriesDisconnectedCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting batteries are not connected to the UPS. Recomendations: 1. Connect the UPS Batteries. The UPS will not be capable of supporting it's load if the utility power fails!" --#TYPE "All UPS batteries have been reconnected. (21054)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 21054 cpqRPMTrapUPSBatteryDischarged TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting batteries are completely discharged. Recommendations: 1. Connect the UPS to utility power to charge the batteries. The UPS will not be able to support it's load if the utility power fails!" --#TYPE "The UPS batteries are in a discharged condition. (21057)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 21057 cpqRPMTrapUPSBatteryDischargedCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting batteries are completely discharged. Recommendations: 1. Connect the UPS to utility power to charge the batteries. The UPS will not be able to support it's load if the utility power fails!" --#TYPE "The UPS batteries are in a discharged condition. (21058)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 21058 cpqRPMTrapUPSCheckBreaker TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting an output Breaker or Relay has failed or may be stuck open or closed with this alarm. Recommendations: 1. Check all breakers on the UPS. 2. If this error persists contact technical support." --#TYPE "A UPS circuit breaker needs attention. (21041)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 21041 cpqRPMTrapUPSCheckBreakerCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting an output Breaker or Relay has failed or may be stuck open or closed with this alarm. Recommendations: 1. Check all breakers on the UPS. 2. If this error persists contact technical support." --#TYPE "All breakers are functioning normally. (21042)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 21042 cpqRPMTrapUPSEPOInitiated TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting an Emergency Power Off (EPO) command has been received to shutdown the UPS immediately with out delay. This command may come from a local control panel or from a remote source. Recommendations: 1. Turn the UPS on to reapply power to attached equipment." --#TYPE "Emergency Power Off activated (21037)" --#SEVERITY CRITICAL --#CATEGORY "UPS" ::= 21037 cpqRPMTrapUPSManualLoadDumped TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "The UPS has been powered off with user interaction." --#TYPE "UPS output has been manually turned off. (21033)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 21033 cpqRPMTrapUPSManualLoadDumpedCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "The UPS has been powered off with user interaction." --#TYPE "UPS output has been restored (21034)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 21034 cpqRPMTrapUPSCabinetDoorOpen TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting a cover panel has been removed while utility power is present. Recommendations: 1. Reinstall all panels. 2. If this error persists contact technical support." --#TYPE "A cover panel has been removed. (21045)" --#SEVERITY CRITICAL --#CATEGORY "UPS" ::= 21045 cpqRPMTrapUPSCabinetDoorOpenCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting a cover panel has been removed while utility power is present. Recommendations: 1. Reinstall all panels. 2. If this error persists contact technical support." --#TYPE "A cover panel has been replaced. (21046)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 21046 cpqRPMTrapUPSFanFailure TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting a fan failure has occurred. Recommendations: 1. If this error persists contact technical support." --#TYPE "The UPS has encountered an fan failure. (21035)" --#SEVERITY CRITICAL --#CATEGORY "UPS" ::= 21035 cpqRPMTrapUPSFanFailureCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting a fan failure has occurred. Recommendations: 1. If this error persists contact technical support." --#TYPE "The UPS fan failure has cleared. (21036)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 21036 cpqRPMTrapUPSLossOfRedundancy TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting a loss of redundancy due to one of the following. 1. One or more of the Electronics Modules has failed 2. One or more of the electronics modules has been manually removed. 3. The amount of load on the UPS has increased to the point that the UPS is no longer able to support an N+1 configuration. Recommendations: 1. Check the UPS to see if one of the modules has failed. 2. Make sure that all modules are securely plugged in. 3. Reduce the load to return the N+1 configuration. 4. If the amount of load is now going to exceed and N+1 configuration permanently, change the configuration on the front panel of the UPS to Capacity instead of Parallel N+1." --#TYPE "The UPS N+1 load has been exceeded (21023)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 21023 cpqRPMTrapUPSLossOfRedundancyCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting a loss of redundancy due to one of the following. 1. One or more of the Electronics Modules has failed 2. One or more of the electronics modules has been manually removed. 3. The amount of load on the UPS has increased to the point that the UPS is no longer able to support an N+1 configuration. Recommendations: 1. Check the UPS to see if one of the modules has failed. 2. Make sure that all modules are securely plugged in. 3. Reduce the load to return the N+1 configuration. 4. If the amount of load is now going to exceed and N+1 configuration permanently, change the configuration on the front panel of the UPS to Capacity instead of Parallel N+1." --#TYPE "Loss of redundancy cleared or configuration has changed from N+1 to Capacity (21024)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 21024 cpqRPMTrapUPSShutdownImminent TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting a shutdown imminent condition. Recommendations: 1. Immediately restore power to the UPS. The UPS will not continue to supply power to devices following the shutdown!" --#TYPE "A UPS shutdown is imminent. (21013)" --#SEVERITY CRITICAL --#CATEGORY "UPS" ::= 21013 cpqRPMTrapUPSShutdownImminentCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting a shutdown imminent condition. Recommendations: 1. Immediately restore power to the UPS. The UPS will not continue to supply power to devices following the shutdown!" --#TYPE "The UPS is no longer in an imminent shutdown state. (21014)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 21014 cpqRPMTrapUPSShutdownPending TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting shutdown pending condition. Recommendations: 1. Immediately restore power to the UPS. The UPS will not continue to supply power to devices following the shutdown!" --#TYPE "A UPS shutdown is pending. (21011)" --#SEVERITY MAJOR --#CATEGORY "UPS" ::= 21011 cpqRPMTrapUPSShutdownPendingCleared TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity, cpqRPMTrapURL } DESCRIPTION "A UPS device is reporting shutdown pending condition. Recommendations: 1. Immediately restore power to the UPS. The UPS will not continue to supply power to devices following the shutdown!" --#TYPE "The UPS is no longer pending shutdown. (21012)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 21012 --**************************************************************************** -- Test-Trap cpqRPMTestTrap TRAP-TYPE ENTERPRISE cpqRPMTraps VARIABLES { sysName, cpqRPMTrapDescription, cpqRPMTrapDeviceId, cpqRPMTrapDeviceName, cpqRPMTrapDeviceAddress, cpqRPMTrapType, cpqRPMTrapSeverity } DESCRIPTION "This trap is sent to test SNMP setup." --#TYPE "Test Trap (50001)" --#SEVERITY INFORMATIONAL --#CATEGORY "APPLICATION" ::= 50001 --**************************************************************************** -- PowerManager Traps cpqPMTrapCritical TRAP-TYPE ENTERPRISE cpqPMTraps VARIABLES { sysName, cpqRPMTrapCode, cpqRPMTrapDescription, cpqRPMTrapDeviceName, cpqRPMTrapURL } DESCRIPTION "A critical alarm has occurred. Action: Check the Trap Details for more information." --#TYPE "Critical Alarm (1)" --#SEVERITY CRITICAL --#CATEGORY "UPS" ::= 1 cpqPMTrapWarning TRAP-TYPE ENTERPRISE cpqPMTraps VARIABLES { sysName, cpqRPMTrapCode, cpqRPMTrapDescription, cpqRPMTrapDeviceName, cpqRPMTrapURL } DESCRIPTION "A warning alarm has occurred. Action: Check the Trap Details for more information." --#TYPE "Warning Alarm (2)" --#SEVERITY MINOR --#CATEGORY "UPS" ::= 2 cpqPMTrapInformation TRAP-TYPE ENTERPRISE cpqPMTraps VARIABLES { sysName, cpqRPMTrapCode, cpqRPMTrapDescription, cpqRPMTrapDeviceName, cpqRPMTrapURL } DESCRIPTION "An information alarm has occurred. Action: Check the Trap Details for more information." --#TYPE "Information Alarm (3)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 3 cpqPMTrapCleared TRAP-TYPE ENTERPRISE cpqPMTraps VARIABLES { sysName, cpqRPMTrapCode, cpqRPMTrapDescription, cpqRPMTrapDeviceName, cpqRPMTrapURL } DESCRIPTION "An alarm has cleared. Action: Check the Trap Details for more information." --#TYPE "Cleared Alarm (4)" --#SEVERITY INFORMATIONAL --#CATEGORY "UPS" ::= 4 END