#-MIBFILE: cpqhsv110v3.mib CPQHSV110V3-MIB DEFINITIONS ::= BEGIN DisplayString ::= OCTET STRING PhysAddress ::= OCTET STRING compaq OBJECT IDENTIFIER ::= { enterprises 232 } cpqElementManager OBJECT IDENTIFIER ::= { compaq 136 } cpqHSV OBJECT IDENTIFIER ::= { cpqElementManager 1 } cpqHSVAgent OBJECT IDENTIFIER ::= { cpqHSV 1 } cpqHSVServer OBJECT IDENTIFIER ::= { cpqHSV 2 } hsvObject OBJECT IDENTIFIER ::= { cpqHSV 3 } maHSVMibRev OBJECT IDENTIFIER ::= { cpqHSV 4 } scell OBJECT IDENTIFIER ::= { hsvObject 1 } agent OBJECT IDENTIFIER ::= { hsvObject 2 } host OBJECT IDENTIFIER ::= { hsvObject 3 } nsc OBJECT IDENTIFIER ::= { hsvObject 4 } shelf OBJECT IDENTIFIER ::= { hsvObject 8 } agManufacturer OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The name of the StorageWorks HSV Agent manufacturer." ::= { cpqHSVAgent 1 } agMajVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "StorageWorks HSV Agent Major Version Number (e.g., 3 for 3.0)." ::= { cpqHSVAgent 2 } agMinVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "StorageWorks HSV Agent Minor Version Number (e.g., 0 for 3.0)." ::= { cpqHSVAgent 3 } agHostName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Host System Network Name where the agent resides." ::= { cpqHSVAgent 4 } agEnterprise OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The Enterprise ID subtree for StorageWorks HSV Agent MIB is registered." ::= { cpqHSVAgent 5 } agDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The StorageWorks HSV Agent description." ::= { cpqHSVAgent 6 } agStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentEntry ACCESS read-only STATUS mandatory DESCRIPTION "This table holds the status information for each HSV Management Agent." ::= { cpqHSVAgent 7 } agentEntry OBJECT-TYPE SYNTAX AgentEntry ACCESS read-only STATUS mandatory DESCRIPTION "The Agent information entry." INDEX { agentEntryIndex } ::= { agStatusTable 1 } agentEntry ::= SEQUENCE { agentEntryIndex INTEGER, agentStatus INTEGER, agentEventCode INTEGER, agentEventLevel INTEGER, agentEventTimeDate DisplayString, agentEventDescription DisplayString } agentEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into agentStatusTable ." ::= { agentEntry 1 } agentStatus OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable reports the overall status of the Agent. INFORMATIONAL: Normal Operating Condition MINOR: Warning Condition MAJOR: Failure or Failure Immanent CRITICAL: Agent condition is critical or unknown" ::= { agentEntry 2 } agentEventCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The management agent event code." ::= { agentEntry 3 } agentEventLevel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The management event level." ::= { agentEntry 4 } agentEventTimeDate OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The date and time the event occurred dd-mm-yyyy/hr:min:sec." ::= { agentEntry 5 } agentEventDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Description of the management agent event." ::= { agentEntry 6 } srvCPU OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The server CPU type (e.g., 80486)." ::= { cpqHSVServer 1 } srvComputerType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The server Computer type (e.g., PC/AT)." ::= { cpqHSVServer 2 } srvModel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The server model number." ::= { cpqHSVServer 3 } srvSubModel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The server submodel number." ::= { cpqHSVServer 4 } srvBiosVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The server BIOS Version." ::= { cpqHSVServer 5 } srvOS OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The server operating system name (e.g., WINNT)." ::= { cpqHSVServer 6 } srvOSMajVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The server OS major version number (e.g., 3 for WINNT 3.51)." ::= { cpqHSVServer 7 } srvOSMinVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The server OS minor version number (e.g., 51 for WINNT 3.51)." ::= { cpqHSVServer 8 } maHSVMibRevMajor OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the supported information, correct interpretation of data may require a MIB document with the same major revision level." ::= { maHSVMibRev 1 } maHSVMibRevMinor OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Minor Revision level. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred." ::= { maHSVMibRev 2 } scellTotal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of StorageCells (storage pools) present in the Fusion System." ::= { scell 1 } scellStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ScellEntry ACCESS read-only STATUS mandatory DESCRIPTION "This table holds the status information for each StorageCell." ::= { scell 2 } scellEntry OBJECT-TYPE SYNTAX ScellEntry ACCESS read-only STATUS mandatory DESCRIPTION "The StorageCell information entry." INDEX { scellEntryIndex } ::= { scellStatusTable 1 } scellEntry ::= SEQUENCE { scellEntryIndex INTEGER, scellName DisplayString, scellUUID DisplayString, scellStatus INTEGER, scellEventDescription DisplayString, scellEventTimeDate DisplayString, scellEventCode DisplayString, scellSWComponent INTEGER, scellECode INTEGER, scellCAC INTEGER, scellEIP INTEGER, scellNameDateTime DisplayString } scellEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into scellStatusTable ." ::= { scellEntry 1 } scellName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The StorageCell Name." ::= { scellEntry 2 } scellUUID OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The StorageCell unique ID." ::= { scellEntry 3 } scellStatus OBJECT-TYPE SYNTAX INTEGER { informational(1), minor(2), major(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable reports the overall status of the StorageCell. INFORMATIONAL: Normal Operating Condition MINOR: Warning Condition MAJOR: Failure or Failure Immanent CRITICAL: Condition is critical or unknown" ::= { scellEntry 4 } scellEventDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The StorageCell Event Description." ::= { scellEntry 5 } scellEventTimeDate OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The StorageCell Event Time and Date." ::= { scellEntry 6 } scellEventCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The StorageCell Event Code." ::= { scellEntry 7 } scellSWComponent OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Event Code Software Component ID." ::= { scellEntry 8 } scellECode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The StorageCell Event Code event number." ::= { scellEntry 9 } scellCAC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The event code Corrective Action Code." ::= { scellEntry 10 } scellEIP OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Event Code EIP Type." ::= { scellEntry 11 } scellNameDateTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The StorageCell Name: Date & Time of Event." ::= { scellEntry 12 } hostTotal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of hosts attached the Fusion System." ::= { host 1 } hostStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF HostEntry ACCESS read-only STATUS mandatory DESCRIPTION "This table holds the status information for each Host." ::= { host 2 } hostEntry OBJECT-TYPE SYNTAX HostEntry ACCESS read-only STATUS mandatory DESCRIPTION "The Host information entry." INDEX { hostEntryIndex } ::= { hostStatusTable 1 } hostEntry ::= SEQUENCE { hostEntryIndex INTEGER, hostName DisplayString, hostUUID DisplayString, hostStatus INTEGER } hostEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into hostStatusTable ." ::= { hostEntry 1 } hostName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Host Name." ::= { hostEntry 2 } hostUUID OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Host unique ID." ::= { hostEntry 3 } hostStatus OBJECT-TYPE SYNTAX INTEGER { informational(0), minor(1), major(2), critical(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable reports the overall status of the Host. INFORMATIONAL: Normal Operating Condition MINOR: Warning Condition MAJOR: Failure or Failure Immanent CRITICAL: Condition is critical or unknown" ::= { hostEntry 4 } nscTotal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Network Storage Controllers present in the Fusion System." ::= { nsc 1 } nscStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF NscEntry ACCESS read-only STATUS mandatory DESCRIPTION "This table holds the status information for each Network Storage Controller." ::= { nsc 2 } nscEntry OBJECT-TYPE SYNTAX NscEntry ACCESS read-only STATUS mandatory DESCRIPTION "The NSC information entry." INDEX { nscEntryIndex } ::= { nscStatusTable 1 } nscEntry ::= SEQUENCE { nscEntryIndex INTEGER, nscName DisplayString, nscUUID DisplayString, nscStatus INTEGER } nscEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into nscStatusTable ." ::= { nscEntry 1 } nscName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Network Storage Controller Name." ::= { nscEntry 2 } nscUUID OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The NSC unique ID." ::= { nscEntry 3 } nscStatus OBJECT-TYPE SYNTAX INTEGER { informational(0), minor(1), major(2), critical(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable reports the overall status of the Network Storage Controller. INFORMATIONAL: Normal Operating Condition MINOR: Warning Condition MAJOR: Failure or Failure Immanent CRITICAL: Condition is critical or unknown" ::= { nscEntry 4 } shelfTotal OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of disk shelves present in the HSV system." ::= { shelf 1 } shelfStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ShelfEntry ACCESS read-only STATUS mandatory DESCRIPTION "This table holds the status information for each Shelf." ::= { shelf 2 } shelfEntry OBJECT-TYPE SYNTAX ShelfEntry ACCESS read-only STATUS mandatory DESCRIPTION "The Shelf information entry." INDEX { shelfEntryIndex } ::= { shelfStatusTable 1 } shelfEntry ::= SEQUENCE { shelfEntryIndex INTEGER, shelfStatus INTEGER, shelfId INTEGER, shelfElementType INTEGER, shelfElementNum INTEGER, shelfErrorCode INTEGER } shelfEntryIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index into shelfStatusTable ." ::= { shelfEntry 1 } shelfStatus OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This variable reports the overall status of the Shelf. OTHER: unknown or undeterminable OK: Normal Operating Condition DEGRADED: Warning Condition FAILED: Failure" ::= { shelfEntry 2 } shelfId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Shelf Id (shelf number)." ::= { shelfEntry 3 } shelfElementType OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Shelf Element type. 01: Disk 02: Power Supply 03: Fan 04: Temp Sensor 06: Alarm Horn 07: EMU 12: LCD 15: GBIC 16: Language 17: Comm Port 18: Volt Sensor 19: Amp Sensor 128:Enclosure 130:Back plane 255:Host" ::= { shelfEntry 4 } shelfElementNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Which particular Element of that type." ::= { shelfEntry 5 } shelfErrorCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Element Type's Error Code." ::= { shelfEntry 6 } emuEventTrapInformative TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, shelfId, shelfElementType, shelfElementNum, shelfErrorCode } --#TYPE "EMU Informational Event" --#SUMMARY "scellNameDateTime %s : emuShelfId %d : emuElementType %d : emuElementNum %d : emuErrorCode %d" --#ARGUMENTS {0,1,2,3,4} --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE OK DESCRIPTION "An EMU Informational event has occurred scellNameDateTime: StorageCell name, and date/time emuShelfId: disk shelf number in the cabinet emuElementType: the element type 01: Disk 02: Pwr Supply 03: Fan 04: Temp Sensor 06: Alarm Horn 07: EMU 12: LCD 15: Xcvr 16: Lang 17: Comm Port 18: Volt Sensor 19: Amp Sensor 128:Encl 130:Back plane emuErrorCode: error number " ::= 136001 emuEventTrapNoncritical TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, shelfId, shelfElementType, shelfElementNum, shelfErrorCode } --#TYPE "EMU Non Critical Event" --#SUMMARY "scellNameDateTime %s : emuShelfId %d : emuElementType %d : emuElementNum %d : emuErrorCode %d" --#ARGUMENTS {0,1,2,3,4} --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "An EMU Non-critical event has occurred scellNameDateTime: StorageCell name, and date/time emuShelfId: disk shelf number in the cabinet emuElementType: the element type 01: Disk 02: Pwr Supply 03: Fan 04: Temp Sensor 06: Alarm Horn 07: EMU 12: LCD 15: Xcvr 16: Lang 17: Comm Port 18: Volt Sensor 19: Amp Sensor 128:Encl 130:Back plane emuErrorCode: error number " ::= 136002 emuEventTrapCritical TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, shelfId, shelfElementType, shelfElementNum, shelfErrorCode } --#TYPE "EMU Critical Event" --#SUMMARY "scellNameDateTime %s : emuShelfId %d : emuElementType %d : emuElementNum %d : emuErrorCode %d" --#ARGUMENTS {0,1,2,3,4} --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE CRITICAL DESCRIPTION "An EMU Critical event has occurred scellNameDateTime: StorageCell name, and date/time emuShelfId: disk shelf number in the cabinet emuElementType: the element type 01: Disk 02: Pwr Supply 03: Fan 04: Temp Sensor 06: Alarm Horn 07: EMU 12: LCD 15: Xcvr 16: Lang 17: Comm Port 18: Volt Sensor 19: Amp Sensor 128:Encl 130:Back plane emuErrorCode: error number " ::= 136003 emuEventTrapUnrecoverable TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, shelfId, shelfElementType, shelfElementNum, shelfErrorCode } --#TYPE "EMU Unrecoverable Event" --#SUMMARY "scellNameDateTime %s : emuShelfId %d : emuElementType %d : emuElementNum %d : emuErrorCode %d" --#ARGUMENTS {0,1,2,3,4} --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE FAILED DESCRIPTION "An EMU Unrecoverable event has occurred scellNameDateTime: StorageCell name, and date/time emuShelfId: disk shelf number in the cabinet emuElementType: the element type 01: Disk 02: Pwr Supply 03: Fan 04: Temp Sensor 06: Alarm Horn 07: EMU 12: LCD 15: Xcvr 16: Lang 17: Comm Port 18: Volt Sensor 19: Amp Sensor 128:Encl 130:Back plane emuErrorCode: error number " ::= 136004 sCellEventTrap_1_0 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. During Executive Services initialization the system time value was set to the value contained in the time field. The action field contains one of the following codes which describes the condition that caused the time value to be chosen: " ::= 13600256 sCellEventTrap_1_1 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The system time value was set to the value contained in the time field by a call to the EXEC$SET_TIME service. As part of setting the time in a dual HSV110 controller configuration, the times are synchronized. The action field contains one of the following codes which describes the action taken: " ::= 13600257 sCellEventTrap_3_0 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller identified in the node_name field has failed in communicating with the Cabinet (Rack) Bus Interface Controller." ::= 13600768 sCellEventTrap_3_1 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The physical disk drive identified by the device field has been rendered inoperable. The rack_num field will not be valid until a future release.

The reason_code field contains a code giving the reason the physical disk drive has been rendered inoperable:

" ::= 13600769 sCellEventTrap_3_2 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. A physical disk drive will not be used because the maximum number of physical disk drives already exist in the current Storage System. The affected physical disk drive is identified in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The location of the physical disk drive is contained in the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the reason_code, flags, rss_flags, inq_data, quorum_sequence, capacity, and member_state fields is undefined." ::= 13600770 sCellEventTrap_3_3 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A HSV110 controller has begun booting. That controller is identified in the node_name field. Note that in this case the content of the scell_tag field is undefined." ::= 13600771 sCellEventTrap_3_4 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller identified in the node_name field has finished the process of bringing the Storage System, identified in the scell_tag field, online." ::= 13600772 sCellEventTrap_3_5 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller identified in the node_name field has been joined into the Storage System." ::= 13600773 sCellEventTrap_3_6 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller identified in the node_name field has been ousted from the Storage System identified in the scell_tag field." ::= 13600774 sCellEventTrap_3_7 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller identified in the node_name field is now the Storage System, identified in the scell_tag field, master." ::= 13600775 sCellEventTrap_3_8 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller identified in the node_name field has been brought into the Storage System identified in the scell_tag field." ::= 13600776 sCellEventTrap_4_0 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Undetermined -- more information needed to determine severity. HSV110 controller operation was terminated due to an unrecoverable event detected by either software or hardware or due to an action initiated via the Storage System Management Interface." ::= 13601024 sCellEventTrap_4_1 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Undetermined -- more information needed to determine severity. An HSV110 controller has sent a last gasp message prior to terminating operation. The terminated HSV110 controller is identified in the lter.terminating_ctrlr field. The lter.termination_event.u.value field contains the termination cause (i.e., termination code). The lter.termination_event.termination_location field contains the termination location. The lter.termination_time field contains the termination date and time. The lter.seq field contains the index of the HSV110 controller's Last Termination Event Array element assigned to the termination event. The lter.sw_version, lter.baselevel_id, and lter.ctrlr_model_id fields identify the software level and controller model information. The lter.uptime field contains a value that represents the number of seconds the HSV110 controller has executed functional code since its first power up. Note that the reporting_ctrlr header field identifies the HSV110 controller that received the last gasp message. All other header fields reflect information supplied by the terminating controller." ::= 13601025 sCellEventTrap_4_2 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A machine check occurred while a termination event was being processed. The post-termination operation being performed at the time the event occurred can be derived from the lter.reuea_index field. Note: The lteihd and lter fields may not describe the event that caused the HSV110 controller to terminate operation depending on how far termination processing got before the machine check occurred." ::= 13601026 sCellEventTrap_4_3 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. An unexpected event occurred while a termination event was being processed. The value contained in the uei.type field describes the event as follows:

The post-termination operation being performed at the time the unexpected event occurred is contained in the uei.pto field. Note: The lteihd and lter fields may not describe the event that caused the HSV110 controller to terminate operation depending on how far termination processing got before the unexpected event occurred." ::= 13601027 sCellEventTrap_4_4 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Storage System Event Log validation completed successfully. The content of the cinfo.scelcbi.status field, the cinfo.scelcbi structure, and the minfo.scelmi structure show the validated state of the Storage System Event Log. The meaning of the status value contained in the cinfo.scelcbi.status field is as follows:

Note: The content of the ainfo fields, cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined." ::= 13601028 sCellEventTrap_4_5 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Storage System Event Log validation failed. The content of the cinfo.scelcbi.status field, the cinfo.scelcbi structure, and the minfo.scelmi structure show the state of the Storage System Event Log at the time of the failure. The content and state of the Storage System Event Log have been initialized to their initial operational settings. The meaning of the status value contained in the cinfo.scelcbi.status field is as follows:

Note: The content of the ainfo fields, cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined." ::= 13601029 sCellEventTrap_4_6 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. Event reports were lost due to an insufficient supply of Event Log Packets on the HSV110 controller that is the Storage System Master. The ainfo.events_not_reported field shows the number of event reports lost. Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined." ::= 13601030 sCellEventTrap_4_7 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. Event reports were lost due to an insufficient supply of Event Log Packets on the HSV110 controller that is not the Storage System Master. The ainfo.events_not_reported field shows the number of event reports lost. Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined." ::= 13601031 sCellEventTrap_4_8 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Storage System Termination Event Log has become inaccessible. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the current state of the Storage System Termination Event Log. The meaning of the status value contained in the cinfo.sctelcbi.status field is as follows:

Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi structure is undefined." ::= 13601032 sCellEventTrap_4_9 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Storage System Termination Event Log validation completed successfully. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the validated state of the Storage System Termination Event Log. The meaning of the status value contained in the cinfo.sctelcbi.status field is as follows:

Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi structure is undefined." ::= 13601033 sCellEventTrap_4_a TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Storage System Termination Event Log validation failed. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the state of the Storage System Termination Event Log at the time of the failure. The meaning of the status value contained in the cinfo.sctelcbi.status field is as follows:

Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi structure is undefined." ::= 13601034 sCellEventTrap_4_b TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Storage System Termination Event Log has been updated with the termination event information obtained from the HSV110 controller that is not the Storage System Master. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the updated state of the Storage System Termination Event Log. The meaning of the status value contained in the cinfo.sctelcbi.status field is as follows:

Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi structure is undefined." ::= 13601035 sCellEventTrap_4_c TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The Fault Manager on the Storage System Master received an invalid Event Information Packet from the remote Fault Manager. The header information from the invalid Event Information Packet is contained in the ainfo.remote_event field. Note: The content of the ainfo.quiesce_type field, ainfo.events_not_reported field, cinfo.scelcbi structure, cinfo.sctelcbi structure, minfo.scelmi structure, and minfo.sctelmi structure is undefined." ::= 13601036 sCellEventTrap_4_d TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Fault Manager operation was made quiescent. If the ainfo.quiesce_type field is equal to 0, the operation was performed on both HSV110 controllers. If the ainfo.quiesce_type field is equal to 1, the operation was performed only on the HSV110 controller that is not the Storage System Master. Note: The content of the ainfo.events_not_reported field, cinfo.scelcbi structure, cinfo.sctelcbi structure, minfo.scelmi structure, and minfo.sctelmi structure is undefined." ::= 13601037 sCellEventTrap_4_e TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Undetermined -- more information needed to determine severity. An HSV110 controller sent a last gasp message prior to terminating operation with an indication that the HSV110 controller identified in the lter.terminating_ctrlr field should also terminate operation." ::= 13601038 sCellEventTrap_4_f TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. This HSV110 controller sent its termination event information to the HSV110 controller that is the Storage System Master. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the updated state of the Storage System Termination Event Log. The meaning of the status value contained in the cinfo.sctelcbi.status field is as follows:

Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi structure is undefined." ::= 13601039 sCellEventTrap_4_10 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. Event reports were lost due to an insufficient supply of ISR Event Log Packets on the HSV110 controller that is the Storage System Master. The ainfo.events_not_reported field shows the number of event reports lost. Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined." ::= 13601040 sCellEventTrap_4_11 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. Event reports were lost due to an insufficient supply of ISR Event Log Packets on the HSV110 controller that is not the Storage System Master. The ainfo.events_not_reported field shows the number of event reports lost. Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined." ::= 13601041 sCellEventTrap_6_0 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A physical disk drive has reported that it has exceeded its failure prediction threshold. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows:

Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. The sense data obtained from the physical disk drive as a result of the failure prediction threshold exceeded error is contained in the error field. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601536 sCellEventTrap_6_1 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV110 controller has failed to respond. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. The peb array contains the port event block information. The peq_frz_prod_index field contains the index to the port event block in use when the Tachyon chip entered the frozen state. The peq_prod_index field contains the index to the next port event block. The peq_cons_index field contains the index to the next port event block to be acted upon. The failure_cause field contains the internal routing value as follows: " ::= 13601537 sCellEventTrap_6_2 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A physical disk drive has reported a check condition error. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. The sense data obtained from the physical disk drive as a result of the check condition error is contained in the error field. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601538 sCellEventTrap_6_3 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV110 controller via the mirror port or a Fibre Channel port has timed out. The identity of the intended recipient is contained in the device field. The Fibre Channel port over which the frame was sent is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port number over which the frame was sent is contained in the port field. The arbitrated loop physical address of the intended recipient is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the intended recipient is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The number of timeouts detected is contained in the num_times field. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601539 sCellEventTrap_6_4 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. Work was unexpectedly sent to this HSV110 controller by a physical disk drive or another HSV110 controller. This HSV110 controller did not originate the work. The identity of the sender is contained in the device field. The Fibre Channel port over which the unexpected work was received is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port number over which the unexpected work was received is contained in the port field. The arbitrated loop physical address of the sender is contained in the al_pa field. The location of the sender is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The hdr_cdb field contains the command descriptor block and Fibre Channel header information associated with the unexpected work." ::= 13601540 sCellEventTrap_6_5 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. Work has been sent to a physical disk drive or another HSV110 controller via the mirror port but it did not respond. The identity of the intended target is contained in the device field. The Fibre Channel port over which the work was sent is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which the work was sent is contained in the port field. The arbitrated loop physical address of the intended target is contained in the al_pa field. The location of the intended target is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the intended target is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601541 sCellEventTrap_6_7 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. A Target Discovery Service Descriptor exchange sent to a physical disk drive has timed out. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601543 sCellEventTrap_6_8 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. An excessive number of link errors were detected on a HSV110 controller's Fibre Channel port. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. This is an informational event triggered by the occurrence of an excessive number of Tachyon chip link status errors detected within a particular link status error type. The number of occurrences of each link status error type is contained in a separate type-specific field (e.g., loss_of_signal, bad_rx_char, etc.). The HSV110 controller checks each of its Fibre Channel port's for excessive link status errors periodically." ::= 13601544 sCellEventTrap_6_9 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A physical disk drive has reported numerous failure prediction threshold exceeded errors. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The num_times field is the number of failure prediction threshold exceeded errors reported by the physical disk drive in the previous minute. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601545 sCellEventTrap_6_a TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A physical disk drive has reported numerous check condition errors. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The num_times field is the number of check condition errors reported by the physical disk drive in the previous minute. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601546 sCellEventTrap_6_b TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. A non-data exchange sent to a physical disk drive has timed out. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601547 sCellEventTrap_6_c TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A loop switch has been detected on a Fibre Channel port. The identity of the Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number is contained in the port field. Note that in this case the content of the device, al_pa, rack_num, dencl_num, bay, fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601548 sCellEventTrap_6_d TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The location of a physical disk drive previously reported as unknown is now known. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is contained in the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of fed_class, al_pa and num_times fields are undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601549 sCellEventTrap_6_e TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit requested a code update but the code update could not be found, so the update was not performed. The identity of the affected Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the al_pa, bay, fed_class and num_times field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601550 sCellEventTrap_6_f TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The Drive Enclosure Environmental Monitoring Unit is able to communicate with a physical disk drive but this HSV110 controller is unable to communicate with that physical disk drive on the Fibre Channel bus. The identity of the Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is contained in the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the al_pa, fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601551 sCellEventTrap_6_10 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Undetermined -- more information needed to determine severity. A HSV110 controller is unable to communicate with this Drive Enclosure Environmental Monitoring Unit. The Drive Enclosure Environmental Monitoring Unit identified in the device field has stopped communicating with the HSV110 controller. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the bay, al_pa, fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601552 sCellEventTrap_6_12 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The retry count for a task assigned to a Drive Enclosure Environmental Monitoring Unit has been exhausted. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The peb array contains the task list that was intended to be sent to the Drive Enclosure Environmental Monitoring Unit. The peq_frz_prod_index field contains the task that was being retried. The peq_prod_index field contains the drive enclosure where the physical disk drive used to communicate with the Drive Enclosure Environmental Monitoring Unit is located. The peq_cons_index field identifies the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) used to communicate with the physical disk drive that was used to communicate with the Drive Enclosure Environmental Monitoring Unit. The failure_cause field contains the bay where the physical disk drive used to communicate with the Drive Enclosure Environmental Monitoring Unit." ::= 13601554 sCellEventTrap_6_13 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Drive Enclosure Environmental Monitoring Unit is able to communicate with this HSV110 controller. The identity of the Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the bay, fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601555 sCellEventTrap_6_14 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. There are too many drive enclosures attached to a Fibre Channel port. The Fibre Channel port with too many drive enclosures attached to the HSV110 controller is contained in the cerp_id field. Note that in this case the content of the bay, fed_class, rack_num, dencl_num and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of the identified in the cerp_id field. The device, missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601556 sCellEventTrap_6_15 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The cable connected to the I/O module is attached to the wrong Fibre Channel port. The Fibre Channel port incorrectly attached to the HSV110 controller is contained in the cerp_id field. Note that in this case the content of the device, missing_port, missing_cerp_id, bay, fed_class, rack_num, dencl_num and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601557 sCellEventTrap_6_16 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A HSV110 controller does not have an address on the enclosure address bus. The HSV110 controller location cannot be identified. Note that in this case the content of the missing_port, missing_cerp_id, bay, fed_class, rack_num, dencl_num, al_pa, device, cerp_id, port, enclosures array and num_times fields is undefined." ::= 13601558 sCellEventTrap_6_18 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Drive Enclosure Environmental Monitoring Unit has begun updating its code. Do not power down this drive enclosure until the code update has completed. The identity of the Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. Note also that the content of the fed_class, al_pa, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601560 sCellEventTrap_6_19 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Drive Enclosure Environmental Monitoring Unit has completed updating its code. It is now safe to power down this drive enclosure. The identity of the Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, al_pa, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601561 sCellEventTrap_6_1a TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A physical disk drive has exceeded its soft error threshold. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, cdb, and sense_data fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601562 sCellEventTrap_6_1b TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A HSV110 controller now has an address on the enclosure address bus. The HSV110 controller location has been identified. The location of the HSV110 controller is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the bay, fed_class, al_pa, cerp_id, port, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601563 sCellEventTrap_6_1c TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601564 sCellEventTrap_6_1d TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. A Fibre Channel exchange to a physical disk drive has completed but is missing data. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601565 sCellEventTrap_6_1e TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A HSV110 controller has detected only one port of a Fibre Channel device. This Fibre Channel device has entered the Single Port on Fibre state which should be corrected as soon as possible. The identity of the Fibre Channel device is contained in the device field. The Fibre Channel port still able to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number able to communicate with the Fibre Channel device is contained in the port field. The Fibre Channel port unable to communicate with the Fibre Channel device is contained in the missing_cerp_id field. The HSV110 controller internal Fibre Channel port number unable to communicate with the Fibre Channel device is contained in the missing_port field. The arbitrated loop physical address of the Fibre Channel device is contained in the al_pa field. The location of the Fibre Channel device is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601566 sCellEventTrap_6_1f TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A previously reported Fibre Channel device with only one port has been corrected and redundancy has been restored. The device is no longer in the Single Port on Fibre state. The identity of the Fibre Channel device is contained in the device field. The Fibre Channel port used to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Fibre Channel device is contained in the port field. The missing_port and missing_cerp_id fields are unused. The arbitrated loop physical address of the Fibre Channel device is contained in the al_pa field. The location of the Fibre Channel device is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601567 sCellEventTrap_6_20 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. An unsupported Fibre Channel device has been detected. The drive has been failed to prevent possible data corruption or system instability. The identity of the Fibre Channel device is contained in the device field. The Fibre Channel port used to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Fibre Channel device is contained in the port field. The arbitrated loop physical address of the Fibre Channel device is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the Fibre Channel device is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601568 sCellEventTrap_6_21 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Fibre Channel device with the incorrect block size has been detected. The identity of the Fibre Channel device is contained in the device field. The Fibre Channel port used to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Fibre Channel device is contained in the port field. The arbitrated loop physical address of the Fibre Channel device is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the Fibre Channel device is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601569 sCellEventTrap_6_23 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A HSV110 controller is about to retry a failed port. The Fibre Channel port that is about to be retried is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number about to be retried is contained in the port field. Note that in this case the content of the bay, rack_num, fed_class, al_pa, dencl_num, device, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601571 sCellEventTrap_6_24 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A HSV110 controller has successfully retried a failed port. The Fibre Channel port that has been restarted is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number that has been restarted is contained in the port field. Note that in this case the content of the bay, rack_num, fed_class, al_pa, dencl_num, device, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601572 sCellEventTrap_6_25 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit has failed to assign a hard address to a physical disk drive on the loop. The device field contains the identity of the enclosure. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The al_pa field contains the expected AL_PA, and the num_times field contains the actual AL_PA. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. Note that in this case the content of the fed_class is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601573 sCellEventTrap_6_26 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit has failed to assign an address to a physical disk drive on the loop. This has occurred because another physical disk drive has already obtained this AL_PA. The device field contains the identity of the enclosure. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The al_pa field contains the AL_PA that was stolen. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601574 sCellEventTrap_6_27 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit has failed to assign address(s) to a physical disk drive on the loop. Soft addressing was detected for this enclosure. The device field contains the identity of the enclosure. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, al_pa, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601575 sCellEventTrap_6_28 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The retry count for an OB task assigned to a Drive Enclosure Environmental Monitoring Unit has been exhausted. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The peb array contains the task list that was intended to be sent to the Drive Enclosure Environmental Monitoring Unit. The peq_frz_prod_index field contains the task that was being retried. The peq_prod_index field contains the drive enclosure where the physical disk drive used to communicate with the Drive Enclosure Environmental Monitoring Unit is located. The peq_cons_index field identifies the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) used to communicate with the physical disk drive that was used to communicate with the Drive Enclosure Environmental Monitoring Unit. The failure_cause field contains the bay where the physical disk drive used to communicate with the Drive Enclosure Environmental Monitoring Unit." ::= 13601576 sCellEventTrap_6_29 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller has sent a Basic Link Service command Abort Sequence Frame. The original work is described in this event. The identity of the intended target is contained in the device field. The Fibre Channel port over which the work was sent is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which the work was sent is contained in the port field. The arbitrated loop physical address of the intended target is contained in the al_pa field. The location of the intended target is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the intended target is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601577 sCellEventTrap_6_2a TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller has sent an Extended Link Service command Reinstate Recovery Qualifier. The original work is described in this event. The identity of the intended target is contained in the device field. The Fibre Channel port over which the work was sent is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which the work was sent is contained in the port field. The arbitrated loop physical address of the intended target is contained in the al_pa field. The location of the intended target is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the intended target is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601578 sCellEventTrap_6_2b TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case." ::= 13601579 sCellEventTrap_6_2c TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. One or more media defects were detected on a physical disk drive. The affected physical disk drive is identified in the device field. The Fibre Channel port over which the media defect(s) was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port number over which the media defect(s) was detected is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The Logical Block Address of each media defect is contained in a separate entry of the hdr_cdb array. Only nonzero values in the hdr_cdb array entries are valid. The location of the physical disk drive is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release." ::= 13601580 sCellEventTrap_6_2d TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. An HSV110 controller issued a directed LIP to an arbitrated loop physical address. The Fibre Channel port over which the directed LIP was issued is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port number over which the directed LIP was issued is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field." ::= 13601581 sCellEventTrap_6_2e TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. An HSV110 controller has detected Loop Receiver Failures. The Fibre Channel port over which the Loop Receiver Failures were detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port number over which the Loop Receiver Failures were detected is contained in the port field. The counts and the AL_PAs of the Loop Receiver Failures are contained in a separate entry of the hdr_cdb array. Only nonzero values in the hdr_cdb array entries are valid. The affected HSV110 controller is identified in the device field. Note that in this case the content of the al_pa, dencl_num, bay, and rack_num fields are undefined." ::= 13601582 sCellEventTrap_6_30 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A HSV110 controller has detected only one port of all Fibre Channel devices in an enclosure. These Fibre Channel devices have entered the Single Port on Fibre state which should be corrected as soon as possible. The identity of the Fibre Channel device enclosure is contained in the device field. The Fibre Channel port still able to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number able to communicate with the Fibre Channel device is contained in the port field. The Fibre Channel port unable to communicate with the Fibre Channel device is contained in the missing_cerp_id field. The HSV110 controller internal Fibre Channel port number unable to communicate with the Fibre Channel device is contained in the missing_port field. The al_pa and bay fields are invalid. The location of the Fibre Channel enclosure is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601584 sCellEventTrap_6_31 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A previously reported Fibre Channel device enclosure with only one port has been corrected and redundancy has been restored. The devices in the enclosure are no longer in the Single Port on Fibre state. The identity of the Fibre Channel device enclosure is contained in the device field. The Fibre Channel port used to communicate with the Fibre Channel device enclosure is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Fibre Channel device is contained in the port field. The al_pa, bay, missing_port, and missing_cerp_id fields are invalid. The location of the Fibre Channel device is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601585 sCellEventTrap_6_32 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A HSV110 controller has detected only one port of all Fibre Channel devices on a loop. These Fibre Channel devices have entered the Single Port on Fibre state which should be corrected as soon as possible. The device, al_pa, dencl_num, and bay fields are all invalid. The Fibre Channel port still able to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number able to communicate with the Fibre Channel device is contained in the port field. The Fibre Channel port unable to communicate with the Fibre Channel device is contained in the missing_cerp_id field. The HSV110 controller internal Fibre Channel port number unable to communicate with the Fibre Channel device is contained in the missing_port field." ::= 13601586 sCellEventTrap_6_33 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A previously reported Fibre Channel loop with only one port has been corrected and redundancy has been restored. The devices on the loop are no longer in the Single Port on Fibre state. The device, al_pa, dencl_num, bay, missing_port, and missing_cerp_id fields are invalid. The Fibre Channel port used to communicate with the Fibre Channel devices is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Fibre Channel devices is contained in the port field." ::= 13601587 sCellEventTrap_6_34 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A HSV110 controller has been told to enable a device port, and that device port was not disabled during boot diagnostics. The Fibre Channel port that was enabled is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number enabled is contained in the port field. Note that in this case the contents of the bay, rack_num, fed_class, al_pa, dencl_num, device, enclosure array, and num_times fields are undefined. The missing_port and missing_cerp_id fields are unused." ::= 13601588 sCellEventTrap_6_35 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. An unrecognized Fibre Channel physical disk drive firmware revision has been detected by the physical disk drive firmware load process. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The bypass_reason field is invalid. The location of the physical disk drive is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The pid field contains the SCSI Inquiry Product Identification obtained from the physical disk drive. The rev field contains the current firmware revision obtained from the physical disk drive. The new_rev field contains the latest firmware version known to the controller, or blanks if the isn't a known version. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601589 sCellEventTrap_6_36 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. An unsupported Fibre Channel physical disk drive firmware revision has been detected by the physical disk drive firmware load process. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The bypass_reason field is invalid. The location of the physical disk drive is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The pid field contains the SCSI Inquiry Product Identification obtained from the physical disk drive. The rev field contains the current firmware revision obtained from the physical disk drive. The new_rev field contains the latest firmware version known to the controller, or blanks if the isn't a known version. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601590 sCellEventTrap_6_37 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Fibre Channel physical disk drive firmware revision has been detected by the physical disk drive firmware load process that is later than the latest known supported revision. If the location information is 0, it indicates the type of drive, not a specific drive. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The bypass_reason field is invalid. The location of the physical disk drive is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The pid field contains the SCSI Inquiry Product Identification obtained from the physical disk drive. The rev field contains the current firmware revision obtained from the physical disk drive. The new_rev field contains the latest firmware version known to the controller, or blanks if the isn't a known version. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601591 sCellEventTrap_6_38 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Fibre Channel physical disk drive firmware revision has been detected by the physical disk drive firmware load process that has a newer supported revision available. If the location information is 0, it indicates the type of drive, not a specific drive. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The bypass_reason field is invalid. The location of the physical disk drive is determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The pid field contains the SCSI Inquiry Product Identification obtained from the physical disk drive. The rev field contains the current firmware revision obtained from the physical disk drive. The new_rev field contains the latest firmware version known to the controller, or blanks if the isn't a known version. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13601592 sCellEventTrap_6_39 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller bypassed a device bay in an attempt to restore operability. The identity of the bay is indicated by the rack_num, dencl_num, and bay fields. All other fields are invalid." ::= 13601593 sCellEventTrap_6_3a TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller is attempting to recovery devices on the indicated port. All other fields are invalid." ::= 13601594 sCellEventTrap_6_3b TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller has finished error recovery attempts on the indicated port. All other fields are invalid." ::= 13601595 sCellEventTrap_6_3c TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller been requested to unbypass device bays on the indicated port. All other fields are invalid." ::= 13601596 sCellEventTrap_6_3d TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Undetermined -- more information needed to determine severity. The HSV110 controller has detected a enclosure on the CAB bus that does not have a Fibre Channel connection. All fields except port and rack are invalid. other fields are invalid." ::= 13601597 sCellEventTrap_6_3e TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The HSV110 controller has detected an enclosure on the Fibre Channel but is unable to communicate with the EMU on the CAB bus or the EMU is reporting an invalid enclosure number. All fields except port and rack are invalid. other fields are invalid." ::= 13601598 sCellEventTrap_7_0 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. Allocation of a Virtual Disk has stalled due to insufficient space in the Disk Group caused by the failure or pulling of a physical disk drive. The tag1 field contains the identity of the Virtual Disk. The tag2 field contains the identity of the Disk Group. The values that may be found in the state field are as follows: " ::= 13601792 sCellEventTrap_7_1 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. Expansion of a Virtual Disk has stalled due to insufficient space in the Disk Group caused by the failure or pulling of a physical disk drive. The tag1 field contains the identity of the Virtual Disk. The tag2 field contains the identity of the Disk Group. The values that may be found in the state field are as follows: " ::= 13601793 sCellEventTrap_7_2 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. Leveling of capacity in a Disk Group has started. The identity of the Disk Group is contained in the tag1 field." ::= 13601794 sCellEventTrap_7_3 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. Leveling of capacity in a Disk Group has finished. The identity of the Disk Group is contained in the tag1 field." ::= 13601795 sCellEventTrap_7_4 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A member management operation has started due to the appearance or disappearance of a physical disk drive. If available, the tag1 field contains the identity of the physical disk drive. The tag2 field contains the disk unit block in which physical disk drive resides. The values that may be found in the state field are as follows: " ::= 13601796 sCellEventTrap_7_5 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A member management operation has finished. If available, the tag1 field contains the identity of the physical disk drive. The tag2 field contains the disk unit block in which the physical disk drive resides. The values that may be found in the state field are as follows: The status field contains one of the following values: " ::= 13601797 sCellEventTrap_7_6 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Disk Group has started changing its internal structure due to the appearance or disappearance of a Volume. The identity of the Disk Group is contained in the tag1 field. The values that may be found in the state field are as follows: " ::= 13601798 sCellEventTrap_7_7 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Disk Group has finished changing its internal structure due to the appearance or disappearance of a volume. The identity of the Disk Group is contained in the tag1 field. The values that may be found in the state field are as follows: " ::= 13601799 sCellEventTrap_7_8 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. Deallocation of a Virtual Disk has failed after three attempts due to unknown circumstances. This will more than likely be caused by failing physical drives. The deletion will be restarted when a resync/reboot occurs. The tag1 field contains the identity of the Virtual Disk. The tag2 field contains the identity of the Disk Group. The values that may be found in the status field indicate the returned status from the delete operation." ::= 13601800 sCellEventTrap_9_1 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The state of the Physical Disk Drive identified in the handle field has transitioned to the NORMAL state. The value.ul1 field contains the new state: 1 (NORMAL). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release." ::= 13602305 sCellEventTrap_9_2 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The state of a Volume has changed. The identity of the affected Volume is contained in the handle field. The add_handle field contains the identity of the Physical Disk Drive that is associated with that Volume. The enclosure number, bay number, and rack number where the associated Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], and attribute.value.u32[2] fields, respectively. The internal identification of that Volume's Redundant Storage Set is contained in the attribute.value.u32[3] field. The attribute.type field contains the value of 1. The value.ul1 field contains the new state. The value.ul2 field contains the old state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: " ::= 13602306 sCellEventTrap_9_3 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has changed. The value.ul1 field contains the new state. The value.ul2 field contains the old state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: " ::= 13602307 sCellEventTrap_9_4 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The state of the HSV110 controller identified in the handle field has transitioned to the NORMAL state. The value.ul1 field contains the new state: 1 (NORMAL). The value.ul2 field contains the old state: 3 (FAILED)." ::= 13602308 sCellEventTrap_9_5 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The state of a battery assembly within the HSV110 controller identified in the handle field has changed. The value.ul1 field contains the new state. The value.ul2 field contains the old state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: " ::= 13602309 sCellEventTrap_9_6 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Undetermined -- more information needed to determine severity. A Volume has transitioned to the MISSING state. The affected Volume is identified in the handle field. The add_handle field contains the identity of the Physical Disk Drive that is associated with that Volume. The enclosure number, bay number, and rack number where the associated Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], and attribute.value.u32[2] fields, respectively. The internal identification of that Volume's Redundant Storage Set is contained in the attribute.value.u32[3] field. The attribute.type field contains the value of 1. The value.ul1 field contains the new state. The value.ul2 field contains the old state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: " ::= 13602310 sCellEventTrap_9_7 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The state of the Fibre Channel port identified in the attribute.value.str field and located on the rear panel of the HSV110 controller identified in the handle field has transitioned to the NORMAL state. The attribute.type field contains the value 4. The value.ul1 field contains the new state: 1 (NORMAL). The value.ul2 field contains the old state: 2 (FAILED).

Note that the HSV110 controller's internal identity of the affected Fibre Channel port is contained in the secondary_id field." ::= 13602311 sCellEventTrap_9_8 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. The Occupancy Alarm Level threshold has been reached for the Disk Group identified in the handle field." ::= 13602312 sCellEventTrap_9_9 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Resource Availability state of a Volume has transitioned to the SUFFICIENT state. The affected Volume is identified in the handle field. The add_handle field contains the identity of the Physical Disk Drive that is associated with that Volume. The enclosure number, bay number, and rack number where the associated Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], and attribute.value.u32[2] fields, respectively. The internal identification of that Volume's Redundant Storage Set is contained in the attribute.value.u32[3] field. The attribute.type field contains the value of 1. The value.ul1 field contains the new state: 0 (SUFFICIENT). The value.ul2 field contains the old state: 1 (INSUFFICIENT)." ::= 13602313 sCellEventTrap_9_a TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Data Availability state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has transitioned to the NORMAL state. The value.ul1 field contains the new state: 0 (NORMAL). The value.ul2 field contains the old state: 1 (DATA LOST)." ::= 13602314 sCellEventTrap_9_c TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Snapclone Logical Disk identified in the handle field has completed the unsharing operation. The secondary_id field contains the noid of the associated successor internal Logical Disk." ::= 13602316 sCellEventTrap_9_d TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The state of the Quorum Disk flag of a Volume has changed. The affected Volume is identified in the handle field. The value.ul1 field contains the new state of the Quorum Disk flag. The value.ul2 field contains the old state of the Quorum Disk flag. The state values that may be found in the value.ul1 and value.ul2 fields are as follows:

" ::= 13602317 sCellEventTrap_9_e TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The temperature trip point for a temperature sensor located within an HSV110 controller has been reached. The HSV110 controller is identified in the handle field. The value.ul1 field contains the current temperature reading from I2C sensor 1 in degrees celsius while the value.ul2 field contains the adjusted reading from I2C sensor 2. The set temperature trip point is contained in the secondary_id field." ::= 13602318 sCellEventTrap_9_f TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. The temperature within the HSV110 controller identified in the handle field is approaching its trip point. The value.ul1 field contains the current temperature reading from I2C sensor 1 in degrees celsius while the value.ul2 field contains the adjusted reading from I2C sensor 2. The secondary_id field contains the set temperature trip point in Celsius." ::= 13602319 sCellEventTrap_9_11 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Blower Present flag for the '1' blower assembly located within the HSV110 controller identified in the handle field has transitioned from the NOT PRESENT to PRESENT state indicating that the blower has been reinstalled. The secondary_id field contains the '1' blower assembly internal identifier value: 1. The value.ul1 field contains the new state of the Blower Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Blower Present flag: 0 (NOT PRESENT)." ::= 13602321 sCellEventTrap_9_12 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The '1' blower located within the HSV110 controller identified in the handle field is running slower than the lowest acceptable speed. The secondary_id field contains the '1' blower assembly internal identifier value: 1. The value.ul1 field contains the current speed of the '1' blower. The value.ul2 field contains the lowest acceptable speed for the '1' blower." ::= 13602322 sCellEventTrap_9_13 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. One of the voltage sensors located within the HSV110 controller identified in the handle field has reported a voltage that is out of range. The value.ul1 field contains the out of range voltage value. The secondary_id field contains the specific voltage threshold value (i.e., 12V, 5V, 3.3V, 2.5V or 2V). Note that the voltages are expressed in millivolts--e.g.,12.5V is expressed as 12500." ::= 13602323 sCellEventTrap_9_14 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Undetermined -- more information needed to determine severity. The state of a Volume has transitioned to the FAILED state. The affected Volume is identified in the handle field. The add_handle field contains the identity of the Physical Disk Drive that is associated with that Volume. The enclosure number, bay number, and rack number where the associated Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], and attribute.value.u32[2] fields, respectively. The internal identification of that Volume's Redundant Storage Set is contained in the attribute.value.u32[3] field. The attribute.type field contains the value of 1. The value.ul1 field contains the new state: 7 (FAILED). The value.ul2 field contains the old state. The state values that may be found in the value.ul2 fields are as follows: " ::= 13602324 sCellEventTrap_9_15 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Undetermined -- more information needed to determine severity. An HSV110 controller has failed. The state of the HSV110 controller identified in the handle field has transitioned to the FAILED state. The value.ul1 field contains the new state: 3 (FAILED). The value.ul2 field contains the old state: 1 (NORMAL)." ::= 13602325 sCellEventTrap_9_16 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The temperature within the HSV110 controller identified in the handle field has returned to its normal operating range. The value.ul1 field contains the current temperature reading in celsius from I2C sensor 1, while the value.ul2 field contains the adjusted reading from I2C sensor 2." ::= 13602326 sCellEventTrap_9_17 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. An HSV110 controller's battery assembly has been removed. The Battery Present flag for battery assembly '1' located within the HSV110 controller identified in the handle field has changed from PRESENT to NOT PRESENT indicating that the battery assembly was removed. The secondary_id field contains the battery assembly '1' internal identifier value: 1. The value.ul1 field contains the new state of the Battery Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Battery Present flag: 1 (PRESENT)." ::= 13602327 sCellEventTrap_9_18 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Battery In Use flag for battery assembly '1' located within the HSV110 controller identified in the handle field has transitioned from the NOT IN USE to IN USE state indicating that the battery assembly is functioning properly. The secondary_id field contains the battery assembly '1' internal identifier value: 1. The value.ul1 field contains the new state of the Battery In Use flag: 1 (IN USE). The value.ul2 field contains the old state of the Battery In Use flag: 0 (NOT IN USE)." ::= 13602328 sCellEventTrap_9_19 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. One of the voltage sensors located within the HSV110 controller identified in the handle field has reported a voltage that indicates that a voltage that was previously out of range has returned to the normal range. The value.ul1 field contains the normal range voltage value. The secondary_id field contains the voltage threshold value (i.e., 12V, 5V, 3.3V, 2.5V or 2V). Note that the voltages are expressed in thousands--e.g., 12.5V is expressed as 12500." ::= 13602329 sCellEventTrap_9_1a TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. The battery assembly voltage regulator located within the HSV110 controller identified in the handle field is offline." ::= 13602330 sCellEventTrap_9_1b TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The state of the Disk Group identified in the handle field has transitioned to the NORMAL state. The value.ul1 field contains the new Disk Group state: 1 (NORMAL). The value.ul2 field contains the old Disk Group state. The state values that may be found in the value.ul2 field are as follows: " ::= 13602331 sCellEventTrap_9_1c TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Occupancy Alarm Level for the Disk Group identified in the handle field has returned to the normal range." ::= 13602332 sCellEventTrap_9_1d TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. An HSV110 controller's battery assembly has malfunctioned. The Battery In Use flag for battery assembly '1' located within the HSV110 controller identified in the handle field has transitioned from the IN USE to NOT IN USE state indicating that the battery assembly has malfunctioned. The secondary_id field contains the battery assembly '1' internal identifier value: 1. The value.ul1 field contains the new state of the Battery In Use flag: 0 (NOT IN USE). The value.ul2 field contains the old state of the Battery In Use flag: 1 (IN USE)." ::= 13602333 sCellEventTrap_9_1e TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Battery Present flag for battery assembly '1' located within the HSV110 controller identified in the handle field has changed from NOT PRESENT to PRESENT indicating that the battery assembly was reinstalled. The secondary_id field contains the battery assembly '1' internal identifier value: 1. The value.ul1 field contains the new state of the Battery Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Battery Present flag: 0 (NOT PRESENT)." ::= 13602334 sCellEventTrap_9_1f TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. An HSV110 controller's battery assembly has been removed. The Battery Present flag for battery assembly '2' located within the HSV110 controller identified in the handle field has changed from PRESENT to NOT PRESENT indicating that the battery assembly was removed. The secondary_id field contains the battery assembly '2' internal identifier value: 2. The value.ul1 field contains the new state of the Battery Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Battery Present flag: 1 (PRESENT)." ::= 13602335 sCellEventTrap_9_20 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Battery Present flag for battery assembly '2' located within the HSV110 controller identified in the handle field has changed from NOT PRESENT to PRESENT indicating that the battery assembly was reinstalled. The secondary_id field contains the battery assembly '2' internal identifier value: 2. The value.ul1 field contains the new state of the Battery Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Battery Present flag: 0 (NOT PRESENT)." ::= 13602336 sCellEventTrap_9_21 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Battery In Use flag for battery assembly '2' located within the HSV110 controller identified in the handle field has transitioned from the NOT IN USE to IN USE state indicating that the battery assembly is functioning properly. The secondary_id field contains the battery assembly '2' internal identifier value: 2. The value.ul1 field contains the new state of the Battery In Use flag: 1 (IN USE). The value.ul2 field contains the old state of the Battery In Use flag: 0 (NOT IN USE)." ::= 13602337 sCellEventTrap_9_22 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. An HSV110 controller's battery assembly has malfunctioned. The Battery In Use flag for battery assembly '2' located within the HSV110 controller identified in the handle field has transitioned from the IN USE to NOT IN USE state indicating that the battery assembly has malfunctioned. The secondary_id field contains the battery assembly '2' internal identifier value: 2. The value.ul1 field contains the new state of the Battery In Use flag: 0 (NOT IN USE). The value.ul2 field contains the old state of the Battery In Use flag: 1 (IN USE)." ::= 13602338 sCellEventTrap_9_23 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The Blower Present flag for the '2' blower assembly located within the HSV110 controller identified in the handle field has transitioned from the PRESENT to NOT PRESENT state indicating that the blower has been removed. The secondary_id field contains the '2' blower assembly internal identifier value: 2. The value.ul1 field contains the new state of the Blower Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Blower Present flag: 1 (PRESENT)." ::= 13602339 sCellEventTrap_9_24 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Blower Present flag for the '2' blower assembly located within the HSV110 controller identified in the handle field has transitioned from the NOT PRESENT to PRESENT state indicating that the blower has been reinstalled. The secondary_id field contains the '2' blower assembly internal identifier value: 2. The value.ul1 field contains the new state of the Blower Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Blower Present flag: 0 (NOT PRESENT)." ::= 13602340 sCellEventTrap_9_25 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The '2' blower located within the HSV110 controller identified in the handle field is running slower than the lowest acceptable speed. The secondary_id field contains the '2' blower assembly internal identifier value: 2. The value.ul1 field contains the current speed of the '2' blower. The value.ul2 field contains the lowest acceptable speed for the '2' blower." ::= 13602341 sCellEventTrap_9_26 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. An HSV110 controller's '1' blower/power supply assembly has been removed or AC power has been removed from the power supply. The HSV110 controller is identified in the handle field. The secondary_id field contains the '1' blower/power supply assembly internal identifier value: 1. The value.ul1 field contains the new state of the Blower/Power Supply Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Blower/Power Supply Present flag: 1 (PRESENT)." ::= 13602342 sCellEventTrap_9_27 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. An HSV110 controller's '1' blower/power supply assembly has been reinstalled or AC power has been restored to the power supply. The HSV110 controller is identified in the handle field. The secondary_id field contains the '1' blower/power supply assembly internal identifier value: 1. The value.ul1 field contains the new state of the Blower/Power Supply Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Blower/Power Supply Present flag: 0 (NOT PRESENT)." ::= 13602343 sCellEventTrap_9_28 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. An HSV110 controller's '2' blower/power supply assembly has been removed or AC power has been removed from the power supply. The HSV110 controller is identified in the handle field. The secondary_id field contains the '2' blower/power supply assembly internal identifier value: 2. The value.ul1 field contains the new state of the Blower/Power Supply Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Blower/Power Supply Present flag: 1 (PRESENT)." ::= 13602344 sCellEventTrap_9_29 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. An HSV110 controller's '2' blower/power supply assembly has been reinstalled or AC power has been restored to the power supply. The HSV110 controller is identified in the handle field. The secondary_id field contains the '2' blower/power supply assembly internal identifier value: 2. The value.ul1 field contains the new state of the Blower/Power Supply Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Blower/Power Supply Present flag: 0 (NOT PRESENT)." ::= 13602345 sCellEventTrap_9_2a TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The '1' blower/power supply located within the HSV110 controller identified in the handle field is running slower than the lowest acceptable speed. The secondary_id field contains the '1' blower/power supply assembly internal identifier value: 1. The value.ul1 field contains the current speed of the '1' blower/power supply. The value.ul2 field contains the lowest acceptable speed for the '1' blower/power supply." ::= 13602346 sCellEventTrap_9_2b TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The '2' blower/power supply located within the HSV110 controller identified in the handle field is running slower than the lowest acceptable speed. The secondary_id field contains the '2' blower/power supply assembly internal identifier value: 2. The value.ul1 field contains the current speed of the '2' blower/power supply. The value.ul2 field contains the lowest acceptable speed for the '2' blower/power supply." ::= 13602347 sCellEventTrap_9_2c TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. The state of a battery assembly within the HSV110 controller identified in the handle field has transitioned to the Battery System Hold-up Time is zero hours state. The value.ul1 field contains the new state 5: (Battery System Hold-up Time is zero hours). The value.ul2 field contains the old state. The state values that may be found in the value.ul2 field are as follows: " ::= 13602348 sCellEventTrap_9_2d TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Undetermined -- more information needed to determine severity. The Resource Availability state of a Volume has transitioned to the INSUFFICIENT state. The affected Volume is identified in the handle field. The add_handle field contains the identity of the Physical Disk Drive that is associated with that Volume. The enclosure number, bay number, and rack number where the associated Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], and attribute.value.u32[2] fields, respectively. The internal identification of that Volume's Redundant Storage Set is contained in the attribute.value.u32[3] field. The attribute.type field contains the value of 1. The value.ul1 field contains the new state: 1 (INSUFFICIENT). The value.ul2 field contains the old state: 0 (SUFFICIENT)." ::= 13602349 sCellEventTrap_9_2e TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field rejected a login attempt. The value.ul1 and value.ul2 fields contain words [0] and [1], respectively, of the World Wide Name of the host adapter that originated the rejected login attempt. The secondary_id field contains the reason for the rejection as follows: " ::= 13602350 sCellEventTrap_9_2f TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field processed a Storage System Management Interface command with the result of non-success return code. The value.ul1 field contains internal the command type. The value.ul2 field contains the internal return code. The attribute.value.obj field contains the internal target and internal version of the command." ::= 13602351 sCellEventTrap_9_30 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has updated the physical disk drive map for the loop pair identified in the secondary_id field. The value.ul1 field contains the new internal map generation number. The value.ul2 field contains the old internal map generation number." ::= 13602352 sCellEventTrap_9_31 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The state of the Physical Disk Drive identified in the handle field has transitioned to the DEGRADED state. The value.ul1 field contains the new state: 2 (DEGRADED). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release." ::= 13602353 sCellEventTrap_9_32 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The state of the Physical Disk Drive identified in the handle field has transitioned to the FAILED state. The value.ul1 field contains the new state: 3 (FAILED). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release." ::= 13602354 sCellEventTrap_9_33 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Derived Unit identified in the handle field was created. The add_handle field contains the identity of the Storage System Virtual Disk that is associated with that Derived Unit. The attribute.value.obj field contains the identity of the Virtual Disk associated with that Derived Unit." ::= 13602355 sCellEventTrap_9_34 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The internal Logical Disk associated with the Virtual Disk identified in the handle field was created. The add_handle field contains the identity of the Disk Group where this internal Logical Disk was created. The attribute.value.u64[0] field contains the size (in blocks) of the internal Logical Disk. The attribute.value.u32[2] field contains the redundancy type of the internal Logical Disk. The attribute.type field contains the value 5. The values that may be found in the attribute.value.u32[2] field are as follows: " ::= 13602356 sCellEventTrap_9_35 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Disk Group identified in the handle field was created. The attribute.value.u32[0] field contains the number of physical disk drives within the Disk Group. The attribute.type field contains the value 1." ::= 13602357 sCellEventTrap_9_36 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Physical Disk Drive identified in the handle field was discovered. The enclosure, bay and rack where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1] and attribute.value.u32[2] fields, respectively. The attribute.type field contains the value 1." ::= 13602358 sCellEventTrap_9_37 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Presented Unit identified in the handle field was created. The add_handle field contains the identity of the Storage System Virtual Disk that is associated with the Presented Unit. This Presented Unit is associated with the Virtual Disk identified in the attribute.value.obj.handle field. The add_handle2 field contains the associated Storage System Host path, and add_data[0] and add_data[1] contains the host LUN number." ::= 13602359 sCellEventTrap_9_38 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Storage System Host path identified in the handle field was created." ::= 13602360 sCellEventTrap_9_39 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Storage System Virtual Disk identified in the handle field was created." ::= 13602361 sCellEventTrap_9_3a TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Volume was created. The Volume is identified in the handle field. The add_handle field contains the identity of the Physical Disk Drive that is associated with that Volume. The enclosure number, bay number, and rack number where the associated Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], and attribute.value.u32[2] fields, respectively. The attribute.type field contains the value of 1." ::= 13602362 sCellEventTrap_9_3b TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Derived Unit identified in the handle field was deleted. The add_handle field contains the identity of the Storage System Virtual Disk that was associated with the Derived Unit. This Derived Unit is associated with the Virtual Disk identified in the attribute.value.obj.handle field." ::= 13602363 sCellEventTrap_9_3c TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The internal Logical Disk associated with the Virtual Disk identified in the handle field was deleted." ::= 13602364 sCellEventTrap_9_3d TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Disk Group identified in the handle field was deleted." ::= 13602365 sCellEventTrap_9_3e TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The Physical Disk Drive identified in the handle field has disappeared. The enclosure, bay and rack where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1] and attribute.value.u32[2] fields, respectively. The attribute.type field contains the value 1." ::= 13602366 sCellEventTrap_9_3f TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Presented Unit identified in the handle field was deleted. The add_handle field contains the identity of the Storage System Virtual Disk that was associated with the Presented Unit. This Presented Unit is associated with the Virtual Disk identified in the attribute.value.obj.handle field." ::= 13602367 sCellEventTrap_9_40 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Storage System Host path identified in the handle field was deleted." ::= 13602368 sCellEventTrap_9_41 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Storage System Virtual Disk identified in the handle field was deleted. The Storage System Virtual Disk is associated with the Virtual Disk identified in the add_handle field." ::= 13602369 sCellEventTrap_9_43 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has joined the Storage System. If the handle field is zero, the HSV110 controller identity could not be obtained due to an unexpected state transition." ::= 13602371 sCellEventTrap_9_44 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Undetermined -- more information needed to determine severity. An HSV110 controller has left the Storage System. The HSV110 controller is identified in the handle field. If the handle field is zero, the HSV110 controller identity could not be obtained due to an unexpected state transition." ::= 13602372 sCellEventTrap_9_45 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Storage System has been deleted by an HSV110 controller. The Storage System is identified in the handle field. The HSV110 controller is identified in the add_handle field. If the handle field or add_handle field is zero, the corresponding identity could not be obtained due to an unexpected state transition." ::= 13602373 sCellEventTrap_9_46 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Data Replication Group identified in the handle field was created." ::= 13602374 sCellEventTrap_9_47 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Data Replication Group identified in the handle field was deleted." ::= 13602375 sCellEventTrap_9_48 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The internal Logical Disk associated with the Snapshot Virtual Disk identified in the handle field was created. The add_handle field contains the identity of the Disk Group where this internal Logical Disk was created. The attribute.value.u64[0] field contains the size (in blocks) of the reserved capacity of the internal Logical Disk. The attribute.value.u32[2] field contains the redundancy type of the internal Logical Disk. The attribute.value.u32[3] field contains the noid of the associated successor internal Logical Disk. The attribute.type field contains the value 6. The values that may be found in the attribute.value.u32[2] field are as follows: " ::= 13602376 sCellEventTrap_9_49 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The internal Logical Disk associated with the Copy of the Virtual Disk identified in the handle field was created. The add_handle field contains the identity of the Disk Group where this internal Logical Disk was created. The attribute.value.u64[0] field contains the size (in blocks) of the reserved capacity of the target Virtual Disk. The attribute.value.u32[2] field contains the redundancy type of the internal Logical Disk. The attribute.value.u32[3] field contains the noid of the associated successor internal Logical Disk. The attribute.type field contains the value 6. The values that may be found in the attribute.value.u32[2] field are as follows: " ::= 13602377 sCellEventTrap_9_65 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Host Operating System mode of the Storage System Host identified in the handle field has changed. The old_attr.type and new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Host Operating System mode. The new_attr.value.u32[0] field contains the new Host Operating System mode. The values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: " ::= 13602405 sCellEventTrap_9_66 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. Time was set on the Storage System identified in the handle field." ::= 13602406 sCellEventTrap_9_67 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The LUN of the Presented Unit identified in the handle field has changed. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0..1] fields contain the value of the old LUN. The new_attr.value.u32[0..1] fields contain the value of the new LUN. The secondary_id field contains the noid portion of the handle for the Storage System Virtual Disk associated with the Presented Unit. This Presented Unit is associated with the Virtual Disk identified in the add_handle field." ::= 13602407 sCellEventTrap_9_68 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Device Addition Policy of the Storage System identified in the handle field has changed. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Device Addition Policy. The new_attr.value.u32[0] field contains the new Device Addition Policy. The policy values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: " ::= 13602408 sCellEventTrap_9_69 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Quiescent state of the Storage System Virtual Disk identified in the handle field has changed. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Quiescent state. The new_attr.value.u32[0] field contains the new Quiescent state. The state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: This Storage System Virtual Disk is associated with the Virtual Disk identified in the add_handle field." ::= 13602409 sCellEventTrap_9_6a TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Enabled/Disabled state of the Storage System Virtual Disk identified in the handle field has changed. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Enabled/Disabled state. The new_attr.value.u32[0] field contains the new Enabled/Disabled state. The state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: This Storage System Virtual Disk is associated with the Virtual Disk identified in the add_handle field." ::= 13602410 sCellEventTrap_9_6b TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Cache Policy of the Storage System Virtual Disk identified in the handle field has changed.

The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Write Cache Policy. The new_attr.value.u32[0] field contains the new Write Cache Policy. The policy values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows:

The old_attr.value.u32[1] field contains the old Read Cache Policy. The new_attr.value.u32[1] field contains the new Read Cache Policy. The policy values that may be found in the old_attr.value.u32[1] and new_attr.value.u32[1] fields are as follows:

The old_attr.value.u32[2] field contains the old Cache Mirroring Policy. The new_attr.value.u32[2] field contains the new Cache Mirroring Policy. The policy values that may be found in the old_attr.value.u32[2] and new_attr.value.u32[2] fields are as follows:

This Storage System Virtual Disk is associated with the Virtual Disk identified in the add_handle field." ::= 13602411 sCellEventTrap_9_6c TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Usage state of a Volume changed. The affected Volume is identified in the handle field. The old_attr.value.u32[0] field contains the old Usage state. The new_attr.value.u32[0] field contains the new Usage state. The Usage state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: This Volume is associated with the Disk Group identified in the add_handle field, if either the old Usage state or the new Usage state is 1. The secondary_id field contains the internal identification of that Volume's Redundant Storage Set." ::= 13602412 sCellEventTrap_9_6d TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Disk Failure Protection Level of the Disk Group identified in the handle field has changed. The old_attr.type and new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old number of physical disk drives available for use. The new_attr.value.u32[0] field contains the new number of physical disk drives available for use." ::= 13602413 sCellEventTrap_9_6e TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Write Protected state of the Derived Unit identified in the handle field has changed. This Derived Unit is associated with the Virtual Disk identified in the add_handle field. The secondary_id field contains the noid portion of the handle for the Storage System Virtual Disk associated with the Derived Unit. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Write Protected state. The new_attr.value.u32[0] field contains the new Write Protected state. The Write Protected state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: This Derived Unit is associated with the Virtual Disk identified in the add_handle field." ::= 13602414 sCellEventTrap_9_70 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. The Physical Disk Drive identified in the handle field has experienced numerous communication failures on a particular Fibre Channel port identified in the new_attr.value.str field. The old_attr.value.u32[0] field contains the internal port ID. The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the old_attr.value.u32[1], old_attr.value.u32[2], old_attr.value.u32[3] fields, respectively. The old_attr.type field contains value 1. The new_attr.value.str field contains the cerp_id of the Fibre Channel port. The new_attr.type field contains value 4." ::= 13602416 sCellEventTrap_9_71 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field received a request to shutdown.

The old_attr.type field and field contain the value 1. The old_attr.value.u32[0] field indicates the type of restart that was requested as follows:

The old_attr.value.u32[1] field indicates whether the other HSV110 controller of the pair was requested to remain operational or to also shutdown as follows:

The old_attr.value.u32[2] field indicates whether the HSV110 controller was requested to remain in the power on state or power itself off as follows:

The old_attr.value.u32[3] field value indicates whether the Physical Disk Drive enclosure(s) was requested to remain in the power on state or to be powered off as follows:

The old_attr.value.u32[4] field value indicates whether the battery assemblies located within the HSV110 controller were requested to be enabled or disabled as follows:

The old_attr.value.u32[5] field contains the number of seconds the shutdown operation was requested to be delayed." ::= 13602417 sCellEventTrap_9_72 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has completed its shutdown preparations.

The old_attr.type field contain the value 1. The old_attr.value.u32[0] field value indicates the result of the HSV110 controller Cache Memory shutdown operation as follows:

The old_attr.value.u32[1] field contains the internal Storage System Management Interface cache shutdown status code.

The old_attr.value.u32[2] field value indicates the result of the Physical Disk Drive enclosure(s) power off operation as follows:

The old_attr.value.u32[3] field contains the internal Storage System Management Interface Physical Disk Drive enclosure(s) power off status code.

The old_attr.value.u32[4] field value indicates the result of the battery assemblies disable operation as follows:

The old_attr.value.u32[5] field value indicates the battery assemblies disable operation failure mode as follows:

" ::= 13602418 sCellEventTrap_9_73 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Failsafe state of the Data Replication Group identified in the handle field has changed. The old_attr.value.u32[0] field contains the old Failsafe state. The new_attr.value.u32[0] field contains the new Failsafe state. The Failsafe state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: " ::= 13602419 sCellEventTrap_9_74 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Mode of the Data Replication Group identified in the handle field has changed. The old_attr.value.u32[0] field contains the old Mode. The new_attr.value.u32[0] field contains the new Mode. The Mode values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: " ::= 13602420 sCellEventTrap_9_75 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Operational state of a Data Replication Group has changed to Synchronous or Asynchronous. The old_attr.value.u32[0] field contains the old Operation state. The new_attr.value.u32[0] field contains the new Operation state. The Operation state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: " ::= 13602421 sCellEventTrap_9_76 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Read Only attribute of the Data Replication Group identified in the handle field has changed. The old_attr.value.u32[0] field contains the old Read Only attribute. The new_attr.value.u32[0] field contains the new Read Only attribute. The Read Only attribute values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: " ::= 13602422 sCellEventTrap_9_77 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Data Replication Group failover has occurred. The handle field contains the identity of the Data Replication Group. The old_attr.value.u32[0] field contains the old Role. The new_attr.value.u32[0] field contains the new Role. " ::= 13602423 sCellEventTrap_9_78 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Data Replication Group has been suspended or resumed. The handle field contains the identity of the Data Replication Group. The old_attr.value.u32[0] field contains the old Suspend state. The new_attr.value.u32[0] field contains the new Suspend state. The Suspend state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: " ::= 13602424 sCellEventTrap_9_79 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Storage System Virtual Disk was added to a Data Replication Group. The Storage System Virtual Disk is identified in the add_handle field. The Data Replication Group is identified in the handle field." ::= 13602425 sCellEventTrap_9_7a TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Storage System Virtual Disk was removed from a Data Replication Group. The Storage System Virtual Disk is identified in the add_handle field. The Data Replication Group is identified in the handle field." ::= 13602426 sCellEventTrap_9_c8 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Undetermined -- more information needed to determine severity. The Data Availability state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has transitioned to the DATA LOST state. The value.ul1 field contains the new state: 1 (DATA LOST). The value.ul2 field contains the old state: 0 (NORMAL)." ::= 13602504 sCellEventTrap_9_c9 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Undetermined -- more information needed to determine severity. The state of the Disk Group identified in the handle field has transitioned to an INOPERATIVE state. The value.ul1 field contains the new Disk Group state. The value.ul2 field contains the old Disk Group state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: " ::= 13602505 sCellEventTrap_9_ca TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Undetermined -- more information needed to determine severity. The state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has transitioned to the FAILED state. The value.ul1 field contains the new state: 5 (FAILED). The value.ul2 field contains the old state. The state values that may be found in the value.ul2 field are as follows: " ::= 13602506 sCellEventTrap_9_cb TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has transitioned to the SNAPSHOT OVERCOMMIT state. The value.ul1 field contains the new state: 7 (SNAPSHOT OVERCOMMIT). The value.ul2 field contains the old state. The state values that may be found in the value.ul2 field are as follows: " ::= 13602507 sCellEventTrap_9_cc TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Undetermined -- more information needed to determine severity. The state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has transitioned to the DEVICE DATA LOST state. The value.ul1 field contains the new state: 10 (DEVICE DATA LOST). The value.ul2 field contains the old state. The state values that may be found in the value.ul2 field are as follows: " ::= 13602508 sCellEventTrap_9_cd TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Undetermined -- more information needed to determine severity. The state of the Fibre Channel port identified in the attribute.value.str field and located on the rear panel of the HSV110 controller identified in the handle field has transitioned to the FAILED state. The attribute.type field contains the value 4. The value.ul1 field contains the new state: 2 (FAILED). The value.ul2 field contains the old state: 1 (NORMAL).

Note that the HSV110 controller's internal identity of the affected Fibre Channel port is contained in the secondary_id field." ::= 13602509 sCellEventTrap_9_ce TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The state of the Disk Group identified in the handle field has transitioned to an INOPERATIVE MARKED state. The value.ul1 field contains the new Disk Group state. The value.ul2 field contains the old Disk Group state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows:

" ::= 13602510 sCellEventTrap_9_cf TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. The state of the Physical Disk Drive identified in the handle field has transitioned to the NOT PRESENT state. The value.ul1 field contains the new state: 4 (NOT PRESENT). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release." ::= 13602511 sCellEventTrap_9_d0 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field no longer needs attention." ::= 13602512 sCellEventTrap_9_d1 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Undetermined -- more information needed to determine severity. The HSV110 controller identified in the handle field needs attention." ::= 13602513 sCellEventTrap_9_d2 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The Blower Present flag for the '1' blower assembly located within the HSV110 controller identified in the handle field has transitioned from the PRESENT to NOT PRESENT state indicating that the blower has been removed. The secondary_id field contains the '1' blower assembly internal identifier value: 1. The value.ul1 field contains the new state of the Blower Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Blower Present flag: 1 (PRESENT)." ::= 13602514 sCellEventTrap_9_d3 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Undetermined -- more information needed to determine severity. At least one Virtual Disk associated with the Data Replication Group identified in the handle field has transitioned to the INOPERATIVE state. The remaining Virtual Disks associated with this Data Replication Group have been forced INOPERATIVE. The value.ul1 field contains the new Data Replication Group member state: 2 (INOPERATIVE). The value.ul2 field contains the old Data Replication Group member state: 1 (OPERATIVE)." ::= 13602515 sCellEventTrap_9_d4 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. All the Virtual Disks associated with the Data Replication Group identified in the handle field have transitioned to the OPERATIVE state. The value.ul1 field contains the new Data Replication Group member state: 1 (OPERATIVE). The value.ul2 field contains the old Data Replication Group member state: 2 (INOPERATIVE)." ::= 13602516 sCellEventTrap_9_d5 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The state of the Physical Disk Drive identified in the handle field has transitioned to the Single Port on Fibre state. The value.ul1 field contains the new state: 5 (SINGLE PORT ON FIBRE). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release." ::= 13602517 sCellEventTrap_9_d6 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has been shutdown because the temperature sensors do not agree and the system temperature can not be accurately determined. The value.ul1 field contains the current temperature reported in celsius from I2C sensor 1, while the value.ul2 field contains the reading from I2C sensor 2." ::= 13602518 sCellEventTrap_9_d7 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has been shutdown because the temperature sensors can not be accessed and the system temperature can not be accurately determined. The value.ul1 field contains the status from the attempted I2C access." ::= 13602519 sCellEventTrap_b_0 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The HSV110 controller identified by the node_name field has begun a resynchronization operation (i.e., a restart of the controllers in a manner that has little or no impact on host system connectivity). The information.pc field contains the program counter of resynchronization operation initiator. The information.flags field contains reboot flags value. The information.code field contains the resynchronization operation event code value." ::= 13602816 sCellEventTrap_c_0 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The specified Destination Virtual Disk has successfully completed a Full Copy. The following fields are not valid: status, blocks, vda." ::= 13603072 sCellEventTrap_c_1 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The specified Source Virtual Disk has transitioned to the Logging state because the alternate Storage System is not accessible or the Data Replication Group is suspended. The following fields are not valid: status, blocks, vda, port, cerp_id, side." ::= 13603073 sCellEventTrap_c_2 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The specified Source Virtual Disk has transitioned to the Logging state because the Destination Virtual Disk is not accessible. The following fields are not valid: status, blocks, vda, port, cerp_id, side." ::= 13603074 sCellEventTrap_c_3 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The specified Destination Virtual Disk has transitioned to the Merging state, because the alternate Storage System or Destination Virtual Disk is now accessible or resumed. The following fields are not valid: status, blocks, vda." ::= 13603075 sCellEventTrap_c_4 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A Data Replication Group has entered the Failsafe Locked state due to an inaccessible or inoperative destination. Either the Destination Virtual Disk is not accessible or a Virtual Disk in the Data Replication Group is inoperative. The following fields are not valid: status, blocks, vda, port, cerp_id, side." ::= 13603076 sCellEventTrap_c_5 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A Data Replication Group has entered the Failsafe Locked state due to an inoperative source. Either the Source Virtual Disk is not accessible or a Virtual Disk in the Data Replication Group is inoperative. The following fields are not valid: status, blocks, vda, port, cerp_id, side." ::= 13603077 sCellEventTrap_c_6 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. An unrecoverable read error occurred on the specified Source Virtual Disk during the Full Copy. The Virtual Disk address specified in the vda field indicates the first block in error. The Full Copy was terminated." ::= 13603078 sCellEventTrap_c_7 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A Full Copy terminated prior to completion. A remote copy error occurred due to an inaccessible alternate Storage System. The Virtual Disk address specified in the vda field indicates the first block in error. The Full Copy will continue when the Data Replication Destination is restored." ::= 13603079 sCellEventTrap_c_8 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A Full Copy terminated prior to completion. A remote copy error occurred due to an inaccessible Destination Virtual Disk. The Virtual Disk address specified in the vda field indicates the first block in error. The Full Copy will continue when the Data Replication Destination is restored." ::= 13603080 sCellEventTrap_c_9 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. A Data Replication Log has been reset due to insufficient Disk Group capacity. The Data Replication Destination has been marked for a Full Copy. The following fields are not valid: status, blocks, vda, port, cerp_id, side." ::= 13603081 sCellEventTrap_c_a TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Data Replication Log has been reset due to a Data Replication Group failover. The following fields are not valid: status, blocks, vda." ::= 13603082 sCellEventTrap_c_c TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Destination Data Replication Group has successfully completed a Merge. The following fields are not valid: status, blocks, vda." ::= 13603084 sCellEventTrap_c_f TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Data Replication Group is no longer in a Failsafe Locked state. The following fields are not valid: status, blocks, vda, port, cerp_id, side." ::= 13603087 sCellEventTrap_c_10 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Destination Data Replication Group has been marked for a Full Copy. The following fields are not valid: status, blocks, vda." ::= 13603088 sCellEventTrap_c_11 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. A Storage System has discovered that a Data Replication Group failover has taken place. This Virtual Disk is transitioning from a Data Replication Source role to a Data Replication Destination role. The following fields are not valid: status, blocks, vda." ::= 13603089 sCellEventTrap_c_12 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. This Data Replication Group is transitioning from a Data Replication Destination role to a Data Replication Source role. The following fields are not valid: status, blocks, vda." ::= 13603090 sCellEventTrap_c_15 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The Data Replication Path between this Site and the Alternate Site has closed, possibly due to a connection failure between the specified host port and the Alternate Site. The following fields are not valid: group_name_uuid, group_uuid, source_scvd_uuid, status, block, vda." ::= 13603093 sCellEventTrap_d_0 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. Unrecognized event reported by a Drive Enclosure Environmental Monitoring Unit. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. The event was reported by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The content of the alarm_error_code field could not be translated into a known event. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603328 sCellEventTrap_d_1 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A physical disk drive that is not Fibre Channel compatible or cannot operate at the link rate established by the drive enclosure I/O modules was detected. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. This problem was detected during spin up of the physical disk drive installed in the drive enclosure bay identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603329 sCellEventTrap_d_2 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The affected drive enclosure bay is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603330 sCellEventTrap_d_3 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. A physical disk drive was removed while software-activated drive locking was enabled on a drive enclosure that does not support drive locking. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The affected drive enclosure bay is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603331 sCellEventTrap_d_4 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A physical disk drive that is capable of operating at the loop link rate established by the drive enclosure I/O module was found to be running at a different rate. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The affected physical disk drive is installed in the drive enclosure bay identified in the alarm_error_code.field.en field. The Fibre Channel loop on which the problem was detected is identified by the content of the alarm_error_code.field.ec field as follows:

The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows:

Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603332 sCellEventTrap_d_33 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. The AC input to a drive enclosure power supply has been lost. This makes the remaining power supply a single point of failure. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The location of the affected power supply (1 or 2) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603379 sCellEventTrap_d_34 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A drive enclosure power supply is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition. The operational power supply will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply shuts down, whichever occurs first. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The location of the affected power supply (1 or 2) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603380 sCellEventTrap_d_35 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A drive enclosure power supply component has failed. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The location of the affected power supply (1 or 2) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603381 sCellEventTrap_d_47 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A drive enclosure blower is not operating properly. This could affect the drive enclosure air flow and cause an over temperature condition. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The location of the affected blower (1 or 2) is identified in the alarm_error_code.field.en field. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows:

The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows:

Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603399 sCellEventTrap_d_4b TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A drive enclosure blower is improperly installed or missing. This affects the drive enclosure air flow and can cause an over temperature condition. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The location of the affected blower (1 or 2) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603403 sCellEventTrap_d_4c TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. Both drive enclosure blowers are missing. This severely affects the drive enclosure air flow and can cause an over temperature condition. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. Note that this event is preceded by a 'drive enclosure blower is improperly installed or missing' event that identifies the location of the first missing blower. The location of the second missing blower (1 or 2) is identified in the alarm_error_code.field.en field of this event. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603404 sCellEventTrap_d_5b TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The location of the temperature sensor (1 through 11) is identified in the alarm_error_code.field.en field as follows:

The temperature sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows:

The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows:

Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603419 sCellEventTrap_d_5f TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. Note that in this case the content of the alarm_error_code.field.en field is undefined.

The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows:

Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603423 sCellEventTrap_d_6f TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. An internal Drive Enclosure Environmental Monitoring Unit error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows:

The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows:

Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603439 sCellEventTrap_d_71 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. An internal Drive Enclosure Environmental Monitoring Unit error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows:

The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows:

Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603441 sCellEventTrap_d_72 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. A Drive Enclosure Environmental Monitoring Unit is unable to collect data for the SCSI-3 Enclosure Services (SES) page. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603442 sCellEventTrap_d_7e TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. Invalid data was read from a Drive Enclosure Environmental Monitoring Unit NVRAM. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603454 sCellEventTrap_d_7f TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. An internal Drive Enclosure Environmental Monitoring Unit error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows:

The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows:

Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603455 sCellEventTrap_d_82 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. A drive enclosure's address is incorrect or the enclosure has no address. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603458 sCellEventTrap_d_83 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit has experienced a hardware failure. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: " ::= 13603459 sCellEventTrap_d_85 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. A drive enclosure power supply failed to respond to a shut down command. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603461 sCellEventTrap_d_8d TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The location of the transceiver (1 through 4) is identified in the alarm_error_code.field.en field as follows:

The transceiver error condition is described by the content of the alarm_error_code.field.ec field as follows:

The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows:

Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603469 sCellEventTrap_d_a1 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The location of the voltage sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows:

The voltage sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows:

The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows:

Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603489 sCellEventTrap_d_b5 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The location of the current sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows:

The current sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows:

The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows:

Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603509 sCellEventTrap_d_d8 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. A drive enclosure backplane invalid NVRAM read error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit.This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the drive enclosure is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603544 sCellEventTrap_d_d9 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A drive enclosure backplane error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the drive enclosure is the affected element. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows:

The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows:

Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603545 sCellEventTrap_d_dd TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A drive enclosure I/O module error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The location of the I/O module (A (01) and B (02)) is identified in the alarm_error_code.field.en field. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows:

The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows:

Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603549 sCellEventTrap_d_de TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. A drive enclosure I/O module is unable to communicate with the Drive Enclosure Environmental Monitoring Unit. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The location of the I/O module (A (01) and B (02)) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603550 sCellEventTrap_d_ec TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. A drive enclosure I/O module invalid NVRAM read error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit.This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: Note that the content of the rack_num field will not be valid until a future release. The location of the I/O module (A (01) or B (02)) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603564 sCellEventTrap_d_f0 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. The status has changed on one or more of the drive enclosures. This is an informational event triggered by the occurrence of a change in the status of a drive enclosure. This event is generated for the HSV element manager GUI and contains no user information. The content of the handle, alarm_error_code field, dencl_num, and rack_num fields have no meaning for this event. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: Note that the content of the enclosures.rack_num field will not be valid until a future release." ::= 13603568 sCellEventTrap_42_0 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. Indicated Host Fibre Channel port transitioned to link down." ::= 13616896 sCellEventTrap_42_1 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. Indicated Host Fibre Channel port transitioned to link failed." ::= 13616897 sCellEventTrap_42_3 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. An excessive number of link errors were detected on a HSV110 controller's Fibre Channel port. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. This is an informational event triggered by the occurrence of an excessive number of Tachyon chip link status errors detected within a particular link status error type. The number of occurrences of each link status error type is contained in a separate type-specific field (e.g., loss_of_signal, bad_rx_char, etc.). The HSV110 controller checks each of its Fibre Channel port's for excessive link status errors periodically." ::= 13616899 sCellEventTrap_42_4 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV110 controller has failed to respond. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. The peb array contains the port event block information. The peq_frz_prod_index field contains the index to the port event block in use when the Tachyon chip entered the frozen state. The peq_prod_index field contains the index to the next port event block. The peq_cons_index field contains the index to the next port event block to be acted upon." ::= 13616900 sCellEventTrap_42_5 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Normal -- informational in nature. Indicated Host Fibre Channel port transitioned to link wedged." ::= 13616901 sCellEventTrap_83_0 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A failure was detected during the execution of this HSV110 controller's on board diagnostics." ::= 13633536 sCellEventTrap_83_1 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Warning -- not failed but attention recommended or required. A GBIC SFF Serial ID Data check code failure was detected during the execution of this HSV110 controller's on board diagnostics." ::= 13633537 sCellEventTrap_83_2 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A battery assembly failure was detected during the execution of this HSV110 controller's on board diagnostics." ::= 13633538 sCellEventTrap_83_3 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A battery assembly failure was detected during the execution of this HSV110 controller's on board diagnostics." ::= 13633539 sCellEventTrap_83_4 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A battery assembly communication failure was detected during the execution of this HSV110 controller's on board diagnostics." ::= 13633540 sCellEventTrap_83_5 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A battery assembly communication failure was detected during the execution of this HSV110 controller's on board diagnostics." ::= 13633541 sCellEventTrap_83_6 TRAP-TYPE ENTERPRISE compaq VARIABLES { scellNameDateTime, scellSWComponent, scellECode, scellCAC, scellEIP } --#TYPE "StorageCell Event" --#SUMMARY "SCellNameTimeDate %s : SWCID %d : ECode: %d : CAC %d : EIP %d." --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" --#STATE WARNING DESCRIPTION "Severity: Critical -- failure or failure imminent. A soft cache memory ECC error or indication of low battery voltage was detected during the execution of this HSV110 controller's on board diagnostics." ::= 13633542 mngmtAgentTrap_1 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Object Already Exists" ::= 136000001 mngmtAgentTrap_2 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Supplied Buffer Too Small" ::= 136000002 mngmtAgentTrap_3 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Object Already Assigned" ::= 136000003 mngmtAgentTrap_4 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Insufficient Available Data Storage" ::= 136000004 mngmtAgentTrap_5 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Internal Error" ::= 136000005 mngmtAgentTrap_6 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid status for logical disk" ::= 136000006 mngmtAgentTrap_7 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Class" ::= 136000007 mngmtAgentTrap_8 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Function" ::= 136000008 mngmtAgentTrap_9 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Logical Disk Block State" ::= 136000009 mngmtAgentTrap_10 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Loop Configuration" ::= 136000010 mngmtAgentTrap_11 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Parameter" ::= 136000011 mngmtAgentTrap_12 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Parameter handle" ::= 136000012 mngmtAgentTrap_13 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Parameter Id" ::= 136000013 mngmtAgentTrap_14 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Quorum Configuration" ::= 136000014 mngmtAgentTrap_15 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Target Handle" ::= 136000015 mngmtAgentTrap_16 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Target Id" ::= 136000016 mngmtAgentTrap_17 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Time" ::= 136000017 mngmtAgentTrap_18 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Media is Inaccessible" ::= 136000018 mngmtAgentTrap_19 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No Fibre Channel Port" ::= 136000019 mngmtAgentTrap_20 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No Image" ::= 136000020 mngmtAgentTrap_21 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No Permission" ::= 136000021 mngmtAgentTrap_22 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system not initialized" ::= 136000022 mngmtAgentTrap_23 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Not a Loop Port" ::= 136000023 mngmtAgentTrap_24 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Not a Participating Controller" ::= 136000024 mngmtAgentTrap_25 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Objects in your system are in use, and their state prevents the operation you wish to perform." ::= 136000025 mngmtAgentTrap_26 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Parameter Object Does Not Exist" ::= 136000026 mngmtAgentTrap_27 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Target Object Does Not Exist" ::= 136000027 mngmtAgentTrap_28 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Timeout" ::= 136000028 mngmtAgentTrap_29 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unknown Id" ::= 136000029 mngmtAgentTrap_30 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unknown Parameter Handle" ::= 136000030 mngmtAgentTrap_31 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MAJOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unrecoverable Media Error" ::= 136000031 mngmtAgentTrap_32 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid State" ::= 136000032 mngmtAgentTrap_33 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Transport Error" ::= 136000033 mngmtAgentTrap_34 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Volume is Missing" ::= 136000034 mngmtAgentTrap_35 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Cursor" ::= 136000035 mngmtAgentTrap_36 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Target for the Operation" ::= 136000036 mngmtAgentTrap_37 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No More Events" ::= 136000037 mngmtAgentTrap_38 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Lock Busy" ::= 136000038 mngmtAgentTrap_39 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Time Not Set" ::= 136000039 mngmtAgentTrap_40 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Not a Supported Version" ::= 136000040 mngmtAgentTrap_41 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No Logical Disk for Vdisk" ::= 136000041 mngmtAgentTrap_42 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Logical disk Presented" ::= 136000042 mngmtAgentTrap_43 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Operation Denied On Slave" ::= 136000043 mngmtAgentTrap_44 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Not licensed for data replication" ::= 136000044 mngmtAgentTrap_45 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Not DR group member" ::= 136000045 mngmtAgentTrap_46 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid DR mode" ::= 136000046 mngmtAgentTrap_47 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid DR State" ::= 136000047 mngmtAgentTrap_48 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Security credentials needed. Please update your system's ID and password in the Storage System Access menu." ::= 136000048 mngmtAgentTrap_49 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Security credentials supplied were invalid. Please update your system's ID and password in the Storage System Access menu." ::= 136000049 mngmtAgentTrap_50 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Security credentials supplied were invalid. Please update your system's ID and password in the Storage System Access menu." ::= 136000050 mngmtAgentTrap_51 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system connection down" ::= 136000051 mngmtAgentTrap_52 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "DR group empty" ::= 136000052 mngmtAgentTrap_53 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Incompatible attribute" ::= 136000053 mngmtAgentTrap_54 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk is a DR group member" ::= 136000054 mngmtAgentTrap_55 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk is a DR log unit" ::= 136000055 mngmtAgentTrap_56 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Cache batteries failed or missing." ::= 136000056 mngmtAgentTrap_57 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk is not presented" ::= 136000057 mngmtAgentTrap_58 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Other controller failed" ::= 136000058 mngmtAgentTrap_59 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Maximum Number of Objects Exceeded." ::= 136000059 mngmtAgentTrap_60 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Max size" ::= 136000060 mngmtAgentTrap_61 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Password mismatch. Please update your system's password in the Storage System Access menu. Continued attempts to access this storage system with an incorrect password will disable management of this storage system." ::= 136000061 mngmtAgentTrap_62 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "DR group is merging" ::= 136000062 mngmtAgentTrap_63 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "DR group is logging" ::= 136000063 mngmtAgentTrap_64 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Connection is suspended" ::= 136000064 mngmtAgentTrap_65 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Bad image header" ::= 136000065 mngmtAgentTrap_66 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Bad image" ::= 136000066 mngmtAgentTrap_67 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Image too large" ::= 136000067 mngmtAgentTrap_68 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EMU not available" ::= 136000068 mngmtAgentTrap_69 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EMU indefinite delay" ::= 136000069 mngmtAgentTrap_70 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Image incompatible with system configuration. Version conflict in upgrade or downgrade not allowed." ::= 136000070 mngmtAgentTrap_71 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Bad image segment" ::= 136000071 mngmtAgentTrap_72 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Image already loaded" ::= 136000072 mngmtAgentTrap_73 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Image Write Error" ::= 136000073 mngmtAgentTrap_74 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Logical Disk Sharing" ::= 136000074 mngmtAgentTrap_75 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Bad Image Size" ::= 136000075 mngmtAgentTrap_76 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Image Load Busy" ::= 136000076 mngmtAgentTrap_77 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Volume Failure Predicted" ::= 136000077 mngmtAgentTrap_78 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Background allocation on the destination member is in progress. This action must complete before any others can be initiated ." ::= 136000078 mngmtAgentTrap_79 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Predecessor Vdisk Condition" ::= 136000079 mngmtAgentTrap_80 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Volume Usage" ::= 136000080 mngmtAgentTrap_81 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Minimum Volumes In Disk Group" ::= 136000081 mngmtAgentTrap_82 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Shutdown In Progress" ::= 136000082 mngmtAgentTrap_83 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Not Ready" ::= 136000083 mngmtAgentTrap_84 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Is Snapshot" ::= 136000084 mngmtAgentTrap_85 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Cannot add or remove DR group member. Mirror cache must be active for this Vdisk. Check controller cache condition." ::= 136000085 mngmtAgentTrap_86 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Inoperative" ::= 136000086 mngmtAgentTrap_87 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Disk group inoperative or less than 8 disks in group" ::= 136000087 mngmtAgentTrap_88 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system inoperative" ::= 136000088 mngmtAgentTrap_89 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Failsafe Locked" ::= 136000089 mngmtAgentTrap_90 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Data Flush Incomplete" ::= 136000090 mngmtAgentTrap_91 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Redundancy Mirrored Inoperative" ::= 136000091 mngmtAgentTrap_92 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Duplicate LUN" ::= 136000092 mngmtAgentTrap_93 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Other remote controller failed" ::= 136000093 mngmtAgentTrap_94 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unknown remote Vdisk" ::= 136000094 mngmtAgentTrap_95 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unknown remote DR group" ::= 136000095 mngmtAgentTrap_96 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "PLDMC failed" ::= 136000096 mngmtAgentTrap_97 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system could not be locked. System busy. Try command again. " ::= 136000097 mngmtAgentTrap_98 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Error on remote storage system." ::= 136000098 mngmtAgentTrap_99 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "This operation can only be completed when the source-destination connection is down." ::= 136000099 mngmtAgentTrap_100 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Login required - password changed." ::= 136000100 mngmtAgentTrap_101 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Numerous login attempts have been detected that uses an incorrect password. Please update your system's password in the Storage System Access menu." ::= 136000101 mngmtAgentTrap_102 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid cookie" ::= 136000102 mngmtAgentTrap_103 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Login timed out" ::= 136000103 mngmtAgentTrap_104 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Max snapshot depth reached" ::= 136000104 mngmtAgentTrap_105 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Attribute mismatch" ::= 136000105 mngmtAgentTrap_106 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The password has been set in Command View EVA. The same password still needs to be set in the controllers." ::= 136000106 mngmtAgentTrap_107 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Not host port" ::= 136000107 mngmtAgentTrap_108 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Duplicate Lun WWID" ::= 136000108 mngmtAgentTrap_109 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "System Inoperative" ::= 136000109 mngmtAgentTrap_110 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "SnapClone Active" ::= 136000110 mngmtAgentTrap_111 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Emu Load Busy" ::= 136000111 mngmtAgentTrap_112 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Duplicate User Name" ::= 136000112 mngmtAgentTrap_113 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Reserved For Code Load" ::= 136000113 mngmtAgentTrap_114 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Already Presented" ::= 136000114 mngmtAgentTrap_115 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid remote storage system" ::= 136000115 mngmtAgentTrap_116 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No Lock" ::= 136000116 mngmtAgentTrap_117 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Maximum Number of Members Exceeded" ::= 136000117 mngmtAgentTrap_118 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Max Destinations" ::= 136000118 mngmtAgentTrap_119 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Empty User Name" ::= 136000119 mngmtAgentTrap_120 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system already initialized" ::= 136000120 mngmtAgentTrap_121 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Already Open" ::= 136000121 mngmtAgentTrap_122 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Session Not Open" ::= 136000122 mngmtAgentTrap_123 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Not Marked Inoperative" ::= 136000123 mngmtAgentTrap_124 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Media Not Available" ::= 136000124 mngmtAgentTrap_125 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Battery System Failed" ::= 136000125 mngmtAgentTrap_126 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "DR Group Member Is Cache Data Lost" ::= 136000126 mngmtAgentTrap_127 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Internal Lock Collision" ::= 136000127 mngmtAgentTrap_128 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "OCP Error" ::= 136000128 mngmtAgentTrap_129 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Mirror Offline" ::= 136000129 mngmtAgentTrap_130 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "This operation cannot be completed if failsafe mode is enabled." ::= 136000130 mngmtAgentTrap_131 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive firmware load abort due to Raid0 virtual disk(s)." ::= 136000131 mngmtAgentTrap_132 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Fibre channel ports are unavailable." ::= 136000132 mngmtAgentTrap_133 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The storage system has reached its maximum number of DR relationship." ::= 136000133 mngmtAgentTrap_1000 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Logical Disk Condition Change" ::= 136001000 mngmtAgentTrap_1001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system is FULL **critical**" ::= 136001001 mngmtAgentTrap_1002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system is almost FULL. Disk group at or above maximum capacity warning level." ::= 136001002 mngmtAgentTrap_1003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Controller Cache Battery Condition Change" ::= 136001003 mngmtAgentTrap_1004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Controller Cache Condition Change" ::= 136001004 mngmtAgentTrap_1005 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Controller Condition Change" ::= 136001005 mngmtAgentTrap_1006 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Controller FC Port Condition Change" ::= 136001006 mngmtAgentTrap_1007 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Physical Device Condition Change" ::= 136001007 mngmtAgentTrap_1008 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Physical Store Condition Change" ::= 136001008 mngmtAgentTrap_1009 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Host condition change" ::= 136001009 mngmtAgentTrap_1010 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system time has been set" ::= 136001010 mngmtAgentTrap_1011 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Volume Condition change" ::= 136001011 mngmtAgentTrap_1012 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Volume insufficient_resources condition change" ::= 136001012 mngmtAgentTrap_1013 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Volume Quorum Disk change" ::= 136001013 mngmtAgentTrap_1014 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The state of an object in the system has changed. View adjacent events for more detail." ::= 136001014 mngmtAgentTrap_2001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Startup Failed" ::= 136002001 mngmtAgentTrap_2002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Management agent event log cleared successfully" ::= 136002002 mngmtAgentTrap_2003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid name specified for storage system" ::= 136002003 mngmtAgentTrap_2004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system is not initialized" ::= 136002004 mngmtAgentTrap_2006 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid name specified for Vdisk" ::= 136002006 mngmtAgentTrap_2007 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk name exceeds maximum length" ::= 136002007 mngmtAgentTrap_2008 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid parameter specified for Vdisk" ::= 136002008 mngmtAgentTrap_2010 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Specified Vdisk size exceeds available size" ::= 136002010 mngmtAgentTrap_2011 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "There are not enough disk drives to create a disk group" ::= 136002011 mngmtAgentTrap_2012 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Number of devices exceeds the available number of disks" ::= 136002012 mngmtAgentTrap_2013 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Number of devices is less than the minimum number required to create a disk group" ::= 136002013 mngmtAgentTrap_2016 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Completed unpresenting virtual disk to host" ::= 136002016 mngmtAgentTrap_2021 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid refresh interval value. Should be numeric and non-negative." ::= 136002021 mngmtAgentTrap_2022 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid security message. Should not be blank." ::= 136002022 mngmtAgentTrap_2023 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk Create Complete" ::= 136002023 mngmtAgentTrap_2025 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system successfully initialized" ::= 136002025 mngmtAgentTrap_2026 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Device Added Successfully" ::= 136002026 mngmtAgentTrap_2030 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Refresh Interval Changed" ::= 136002030 mngmtAgentTrap_2031 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Security Message Changed" ::= 136002031 mngmtAgentTrap_2032 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Present Vdisk to a Host - Complete" ::= 136002032 mngmtAgentTrap_2033 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Control Startup Complete" ::= 136002033 mngmtAgentTrap_2034 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Change Device Usage Complete" ::= 136002034 mngmtAgentTrap_2035 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Control Shutdown - Complete" ::= 136002035 mngmtAgentTrap_2036 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Controller Shutdown - Complete" ::= 136002036 mngmtAgentTrap_2038 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Control Memory Allocation Failure" ::= 136002038 mngmtAgentTrap_2040 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Access level denied or session activity timeout. Please log in again." ::= 136002040 mngmtAgentTrap_2041 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk Snapshot - Completed" ::= 136002041 mngmtAgentTrap_2042 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk Snapclone - Completed" ::= 136002042 mngmtAgentTrap_2047 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Host record added successfully" ::= 136002047 mngmtAgentTrap_2048 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Logical component deleted successfully" ::= 136002048 mngmtAgentTrap_2049 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid host adapter ID" ::= 136002049 mngmtAgentTrap_2050 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Specified device is already a member of the system" ::= 136002050 mngmtAgentTrap_2051 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Create Folder - Completed" ::= 136002051 mngmtAgentTrap_2052 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Change Object Properties - Completed" ::= 136002052 mngmtAgentTrap_2057 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Completed disk group creation" ::= 136002057 mngmtAgentTrap_2058 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Added host port" ::= 136002058 mngmtAgentTrap_2059 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Discarded host port" ::= 136002059 mngmtAgentTrap_2060 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EMU/Shelf code load complete" ::= 136002060 mngmtAgentTrap_2061 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Operation will exceed the available capacity of the disk group" ::= 136002061 mngmtAgentTrap_2062 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Controller(s) code load complete" ::= 136002062 mngmtAgentTrap_2063 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The target device is not in the right condition to perform the operation" ::= 136002063 mngmtAgentTrap_2064 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system Device Addition Policy changed successfully" ::= 136002064 mngmtAgentTrap_2065 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Maximum number of disk groups exceeded" ::= 136002065 mngmtAgentTrap_2066 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Nsa object discard failed." ::= 136002066 mngmtAgentTrap_2067 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "There are not enough disks to meet the minimum number requirement" ::= 136002067 mngmtAgentTrap_2068 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Entry added successfully in the password file" ::= 136002068 mngmtAgentTrap_2069 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Entry updated successfully in the password file" ::= 136002069 mngmtAgentTrap_2070 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Entry discarded successfully in the password file" ::= 136002070 mngmtAgentTrap_2071 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system is not responding in a timely manner and has been placed into an unknown state. This may be due to a prior command with an excessively long execution time, high I/O load, or a network communications error. Recovery will automatically occur when the storage system is able to respond. " ::= 136002071 mngmtAgentTrap_2072 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Object not found. Operation on this object is completed" ::= 136002072 mngmtAgentTrap_2073 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "There is no more available space to create a Vdisk" ::= 136002073 mngmtAgentTrap_2074 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Name or comments contains invalid character(s)" ::= 136002074 mngmtAgentTrap_2075 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Duplicate - Another object with the same name exists." ::= 136002075 mngmtAgentTrap_2076 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No healthy disk group(s) to create a Vdisk. Resolve any abnormal conditions in the disk group first." ::= 136002076 mngmtAgentTrap_2077 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Operating System ID must be a valid number." ::= 136002077 mngmtAgentTrap_2078 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Watchdog successfully started" ::= 136002078 mngmtAgentTrap_2079 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Watchdog successfully stopped" ::= 136002079 mngmtAgentTrap_2080 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Delete Event Config List failed" ::= 136002080 mngmtAgentTrap_2081 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Disk group meltdown repaired successfully." ::= 136002081 mngmtAgentTrap_2082 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "There are no available LUNs to present this Vdisk." ::= 136002082 mngmtAgentTrap_2083 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Controller time synchronization turned on." ::= 136002083 mngmtAgentTrap_2084 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Controller time synchronization turned off." ::= 136002084 mngmtAgentTrap_2085 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "System login failed. Invalid password." ::= 136002085 mngmtAgentTrap_2086 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "System is not set for password validation." ::= 136002086 mngmtAgentTrap_2087 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Agent is already logged in to this system." ::= 136002087 mngmtAgentTrap_2088 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system time set to custom time. Controller time synchronization automatically turned off." ::= 136002088 mngmtAgentTrap_2089 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system time set to SAN appliance time." ::= 136002089 mngmtAgentTrap_2090 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system time set to browser time. Controller time synchronization automatically turned off." ::= 136002090 mngmtAgentTrap_2091 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system time set to controller time. Controller time synchronization automatically turned off." ::= 136002091 mngmtAgentTrap_2092 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to find DR Group on remote storage system." ::= 136002092 mngmtAgentTrap_2093 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "A host must have at least one port. Cannot delete the only host port available." ::= 136002093 mngmtAgentTrap_2095 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Host creation failed. Maximum number of hosts reached." ::= 136002095 mngmtAgentTrap_2096 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Port already exists for this host." ::= 136002096 mngmtAgentTrap_2097 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Error reading parameter string. String is empty." ::= 136002097 mngmtAgentTrap_2098 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Command could not be completed on Master. Controller not found." ::= 136002098 mngmtAgentTrap_2099 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Command could not be completed on Slave. Controller not found." ::= 136002099 mngmtAgentTrap_2100 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Password access for all known storage systems is already enabled or set." ::= 136002100 mngmtAgentTrap_2102 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The local storage system has reached the maximum allowable DR relationship." ::= 136002102 mngmtAgentTrap_2103 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The remote storage system has reached the maximum allowable DR relationship." ::= 136002103 mngmtAgentTrap_3001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Event Manager Offline" ::= 136003001 mngmtAgentTrap_3002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Event Manager Online" ::= 136003002 mngmtAgentTrap_3003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Event Manager - Startup Failed" ::= 136003003 mngmtAgentTrap_3004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Event Manager - Startup Complete" ::= 136003004 mngmtAgentTrap_3007 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Event Manager - Shutdown Complete" ::= 136003007 mngmtAgentTrap_3009 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to open NSA Local Event Log File" ::= 136003009 mngmtAgentTrap_3012 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to open Local Temp Event File - possibly no initialized SC" ::= 136003012 mngmtAgentTrap_3013 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to clear NSA Local Event Log File" ::= 136003013 mngmtAgentTrap_3015 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to clear NSA Event Log File" ::= 136003015 mngmtAgentTrap_3016 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Local log file found on startup" ::= 136003016 mngmtAgentTrap_3017 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Event Queue Flush Error" ::= 136003017 mngmtAgentTrap_3019 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM File Manager Online" ::= 136003019 mngmtAgentTrap_3020 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM File Manager Offline" ::= 136003020 mngmtAgentTrap_3021 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM Log Manager Online" ::= 136003021 mngmtAgentTrap_3022 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM Log Manager Offline" ::= 136003022 mngmtAgentTrap_3024 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Local NSA logfile is empty" ::= 136003024 mngmtAgentTrap_3025 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Event Queue Online" ::= 136003025 mngmtAgentTrap_3028 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Status Descriptions Unavailable" ::= 136003028 mngmtAgentTrap_3029 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM Description Mngr Online" ::= 136003029 mngmtAgentTrap_3035 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: NSA log file unavailable" ::= 136003035 mngmtAgentTrap_3036 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM Memory Allocation Error" ::= 136003036 mngmtAgentTrap_3037 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Local Event Configuration File Unavailable" ::= 136003037 mngmtAgentTrap_3038 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: MLD Notification File Unavailable - retrieving local backup copy" ::= 136003038 mngmtAgentTrap_3039 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Local Notification Host List File Unavailable" ::= 136003039 mngmtAgentTrap_3044 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Override this description with missing filename" ::= 136003044 mngmtAgentTrap_3045 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid storage system event sequence number - can't retrieve event" ::= 136003045 mngmtAgentTrap_3046 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid SC termination event sequence number - can't retrieve event" ::= 136003046 mngmtAgentTrap_3047 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Event config file unavailable from MLD - retrieving local backup copy" ::= 136003047 mngmtAgentTrap_3048 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Local user defined event state file unavailable" ::= 136003048 mngmtAgentTrap_3049 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: EMU event monitoring thread unable to start" ::= 136003049 mngmtAgentTrap_3050 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: EMU event - this description will be overwritten" ::= 136003050 mngmtAgentTrap_3051 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Failed to write Event Config file to MLD" ::= 136003051 mngmtAgentTrap_3053 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Event Configuration Filename Error or File empty" ::= 136003053 mngmtAgentTrap_3054 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Notification Hostlist Filename Error or File empty" ::= 136003054 mngmtAgentTrap_3055 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Event Config List Object Reference Error" ::= 136003055 mngmtAgentTrap_3056 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: SC Parse File successfully uploaded" ::= 136003056 mngmtAgentTrap_3057 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: SC Parse File upload failed" ::= 136003057 mngmtAgentTrap_3058 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Contents of the uploaded parse file invalid - unexpected contents" ::= 136003058 mngmtAgentTrap_3059 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Parse file is empty" ::= 136003059 mngmtAgentTrap_3060 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system being shutdown due to a command failure." ::= 136003060 mngmtAgentTrap_3061 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Could not retrieve a storage system event" ::= 136003061 mngmtAgentTrap_3062 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Init SC Event config list failed" ::= 136003062 mngmtAgentTrap_3063 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Could not initialize Comm infrastructure for event logging to system log" ::= 136003063 mngmtAgentTrap_3064 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Storage system pointer is NULL!" ::= 136003064 mngmtAgentTrap_3065 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Failed to log event to the Appliance event log: check if log is full" ::= 136003065 mngmtAgentTrap_3066 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Description Mngr initialize storage system failed" ::= 136003066 mngmtAgentTrap_3067 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Description file too small. File read problem Or Incomplete file." ::= 136003067 mngmtAgentTrap_3068 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Can't init NT Event object pointer" ::= 136003068 mngmtAgentTrap_3069 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Can't init NT Notification object pointer" ::= 136003069 mngmtAgentTrap_3070 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Appliance Event Logging Failure - log may be full" ::= 136003070 mngmtAgentTrap_3071 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: SCMI returned bad additional events number" ::= 136003071 mngmtAgentTrap_3072 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: SCMI returned zero sized SC Event" ::= 136003072 mngmtAgentTrap_3075 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EventQueue index passed is out of bounds" ::= 136003075 mngmtAgentTrap_3076 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: An abnormal number of duplicate events logged - dropping duplicates" ::= 136003076 mngmtAgentTrap_3077 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: Update of the MLD Status Description file failed" ::= 136003077 mngmtAgentTrap_3078 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: NsaStatusDescriptions.txt open file error" ::= 136003078 mngmtAgentTrap_3079 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "EM: NsaStatusDescriptions.txt file error - file size discrepancy from mld list" ::= 136003079 mngmtAgentTrap_3080 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "SC Event Log has been cleared and restarted. Possible RAID1 Meltdown." ::= 136003080 mngmtAgentTrap_3081 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid logType parameter" ::= 136003081 mngmtAgentTrap_3083 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Log file is empty" ::= 136003083 mngmtAgentTrap_3084 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage System with this WWN is not visible to this agent or the WWN is invalid" ::= 136003084 mngmtAgentTrap_3086 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Parsefile for current firmware version not found. Upload correct parse file." ::= 136003086 mngmtAgentTrap_3090 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The contents of this file appear to be invalid" ::= 136003090 mngmtAgentTrap_3091 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The MIB failed to build due to a missing parse file." ::= 136003091 mngmtAgentTrap_3092 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "MLD description file is older than local file but system is downrev" ::= 136003092 mngmtAgentTrap_3094 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "System is initialized: can't get activeQ events" ::= 136003094 mngmtAgentTrap_3095 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Failed to write file - file could not be opened." ::= 136003095 mngmtAgentTrap_4000 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "MLD Manager Subsystem Error" ::= 136004000 mngmtAgentTrap_4001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "MLD Manager Offline" ::= 136004001 mngmtAgentTrap_4004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "MLD Manager Startup Complete" ::= 136004004 mngmtAgentTrap_4005 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "MLD Manager Abnormal Startup" ::= 136004005 mngmtAgentTrap_4007 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "MLD Manager Shutdown Complete" ::= 136004007 mngmtAgentTrap_4011 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Host IP Address specified" ::= 136004011 mngmtAgentTrap_4012 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to open the NsaMldMgr.dat file for Write" ::= 136004012 mngmtAgentTrap_4013 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to open the NsaMldMgr.dat file for Read" ::= 136004013 mngmtAgentTrap_4014 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Agent Uid does not exist" ::= 136004014 mngmtAgentTrap_4015 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to find object" ::= 136004015 mngmtAgentTrap_4016 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to store object" ::= 136004016 mngmtAgentTrap_4017 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to find storage system object" ::= 136004017 mngmtAgentTrap_4018 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to create MLD" ::= 136004018 mngmtAgentTrap_4020 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "lastSafeChoiceDelay Expired" ::= 136004020 mngmtAgentTrap_4021 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "crashDetectDelay Expired" ::= 136004021 mngmtAgentTrap_4023 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to read Copy1 of MLD" ::= 136004023 mngmtAgentTrap_4024 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Copy 1 of MLD Invalid" ::= 136004024 mngmtAgentTrap_4025 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Copy block of MLD" ::= 136004025 mngmtAgentTrap_4027 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "MLD database capacity not equal to true MLD capacity" ::= 136004027 mngmtAgentTrap_4028 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Backup range out of bounds of copy 1 range" ::= 136004028 mngmtAgentTrap_4029 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "MLD Manager Lock Crash DetectDelay has expired, just taking lock!" ::= 136004029 mngmtAgentTrap_4030 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "MLD Copy 1 Restored" ::= 136004030 mngmtAgentTrap_4031 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "MLD Copy 2 Restored" ::= 136004031 mngmtAgentTrap_4032 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to find UidAssoc Object" ::= 136004032 mngmtAgentTrap_4033 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to store UID Association Object" ::= 136004033 mngmtAgentTrap_4034 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to find UidAssoc Object" ::= 136004034 mngmtAgentTrap_4035 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to read last Fusion event read" ::= 136004035 mngmtAgentTrap_4036 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "MLD Notification Queue Empty" ::= 136004036 mngmtAgentTrap_4037 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to find Notification Object" ::= 136004037 mngmtAgentTrap_4040 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to read Event Log Pointer" ::= 136004040 mngmtAgentTrap_4041 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to read Event Log" ::= 136004041 mngmtAgentTrap_4042 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to store Event Log" ::= 136004042 mngmtAgentTrap_4043 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to read Event Log" ::= 136004043 mngmtAgentTrap_4047 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Previously Read Object Properties do not Match" ::= 136004047 mngmtAgentTrap_4048 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Previously Read Object Properties do not Match" ::= 136004048 mngmtAgentTrap_4049 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to read Notification Host List" ::= 136004049 mngmtAgentTrap_4050 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to store Notification Host List" ::= 136004050 mngmtAgentTrap_4051 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to store Notification Host List and free Lock" ::= 136004051 mngmtAgentTrap_4052 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to read Event Configuration List" ::= 136004052 mngmtAgentTrap_4053 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to store Event Configuration List" ::= 136004053 mngmtAgentTrap_4054 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to store Event Configuration List and free Lock" ::= 136004054 mngmtAgentTrap_4058 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "MLD Manager Mutex Timeout error" ::= 136004058 mngmtAgentTrap_4059 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "MLD Manager list is empty" ::= 136004059 mngmtAgentTrap_5001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Monitor Startup Complete" ::= 136005001 mngmtAgentTrap_5002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Monitor Startup Failed" ::= 136005002 mngmtAgentTrap_5003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Monitor ShutDown Complete" ::= 136005003 mngmtAgentTrap_5004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Monitor Memory Allocation Failure" ::= 136005004 mngmtAgentTrap_5005 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Monitor Mark Agent as Inactive" ::= 136005005 mngmtAgentTrap_5006 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Monitor create thread error" ::= 136005006 mngmtAgentTrap_5007 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Monitor create timer error" ::= 136005007 mngmtAgentTrap_5008 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Monitor agent registration - Complete" ::= 136005008 mngmtAgentTrap_5010 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Monitor initiated a storage system management shutdown because of controller failures" ::= 136005010 mngmtAgentTrap_5011 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unknown storage system rediscovery complete " ::= 136005011 mngmtAgentTrap_5012 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Start monitoring thread for storage system - Complete" ::= 136005012 mngmtAgentTrap_5013 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Start monitoring thread for storage system - Fail" ::= 136005013 mngmtAgentTrap_5014 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Monitoring thread for storage system terminated" ::= 136005014 mngmtAgentTrap_5015 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Rediscover unknown storage system - Error" ::= 136005015 mngmtAgentTrap_5016 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Controller time synchronized to appliance time." ::= 136005016 mngmtAgentTrap_5017 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Appliance and controller time checked for synchronization." ::= 136005017 mngmtAgentTrap_5018 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Controller and appliance time are the same. No need to synchronize." ::= 136005018 mngmtAgentTrap_5019 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Exception caught in monitoring process." ::= 136005019 mngmtAgentTrap_6001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ready" ::= 136006001 mngmtAgentTrap_6002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Index Out of Range" ::= 136006002 mngmtAgentTrap_6003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Cannot access storage system. Communications error." ::= 136006003 mngmtAgentTrap_6004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No controllers found" ::= 136006004 mngmtAgentTrap_6005 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Index" ::= 136006005 mngmtAgentTrap_6006 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Memory allocation failure" ::= 136006006 mngmtAgentTrap_6007 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No physical stores found" ::= 136006007 mngmtAgentTrap_6008 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No storage system found" ::= 136006008 mngmtAgentTrap_6009 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No disk group found" ::= 136006009 mngmtAgentTrap_6010 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Too many disk groups" ::= 136006010 mngmtAgentTrap_6011 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No volumes found" ::= 136006011 mngmtAgentTrap_6012 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No Logical Disks Found" ::= 136006012 mngmtAgentTrap_6013 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Context ID changed during operation" ::= 136006013 mngmtAgentTrap_6014 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No Name" ::= 136006014 mngmtAgentTrap_6015 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Name Size Exceeded" ::= 136006015 mngmtAgentTrap_6016 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Shutdown Complete" ::= 136006016 mngmtAgentTrap_6017 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Mutex Creation Failure" ::= 136006017 mngmtAgentTrap_6018 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The command has timed out. Storage system is busy processing previous command." ::= 136006018 mngmtAgentTrap_6019 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No MLD Handle Set" ::= 136006019 mngmtAgentTrap_6020 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Failed Transport Layer Communication - No Such Id" ::= 136006020 mngmtAgentTrap_6021 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Failed Transport Layer Communication - TimeOut" ::= 136006021 mngmtAgentTrap_6022 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No initialized storage system objects found" ::= 136006022 mngmtAgentTrap_6023 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No Attached Port Found" ::= 136006023 mngmtAgentTrap_6024 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Failed to get SCMI Object Handle" ::= 136006024 mngmtAgentTrap_6025 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Shutdown Both Restart And Power Off Requested" ::= 136006025 mngmtAgentTrap_6026 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Shutdown Drive Shelf Power Off But No Enclosure Power Off Requested" ::= 136006026 mngmtAgentTrap_6027 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Shutdown Disable Battery But No Enclosure Power Off Requested" ::= 136006027 mngmtAgentTrap_6028 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Shutdown Disable Battery But Shutdown Unconditional Requested" ::= 136006028 mngmtAgentTrap_6029 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Shutdown Delay Out Of Range" ::= 136006029 mngmtAgentTrap_6030 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Cache Write Failure" ::= 136006030 mngmtAgentTrap_6031 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Battery Disable Failure" ::= 136006031 mngmtAgentTrap_6032 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Shelf Disable Failure" ::= 136006032 mngmtAgentTrap_6033 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Battery Disable Failed on Both Controllers Batteries" ::= 136006033 mngmtAgentTrap_6034 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Battery Disable Failed on This Controllers Battery" ::= 136006034 mngmtAgentTrap_6035 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Battery Disable Failed on the Other Controllers Battery" ::= 136006035 mngmtAgentTrap_6036 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Requested disk failure protection level is set. Actual level will change when sufficient disk space is available." ::= 136006036 mngmtAgentTrap_6037 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Physical Store Contains Stale or Foreign Volume Information." ::= 136006037 mngmtAgentTrap_6038 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Controller Resynchronization or Reboot Occurred. Context Error" ::= 136006038 mngmtAgentTrap_8001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Operation" ::= 136008001 mngmtAgentTrap_8002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system already created" ::= 136008002 mngmtAgentTrap_8003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Controller already part of storage system configuration" ::= 136008003 mngmtAgentTrap_8004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Physical Store Count Below Minimum" ::= 136008004 mngmtAgentTrap_8005 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Controller not part of storage system configuration" ::= 136008005 mngmtAgentTrap_8006 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Failed to uninitialize storage system" ::= 136008006 mngmtAgentTrap_8007 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system File Open Error" ::= 136008007 mngmtAgentTrap_8008 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system File Write Error" ::= 136008008 mngmtAgentTrap_8009 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system File Read Error" ::= 136008009 mngmtAgentTrap_8010 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Name too long" ::= 136008010 mngmtAgentTrap_8011 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No String Error" ::= 136008011 mngmtAgentTrap_8012 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No MLD Handle Found" ::= 136008012 mngmtAgentTrap_8013 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No Controllers Found" ::= 136008013 mngmtAgentTrap_8014 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Controller Not Found On Loop" ::= 136008014 mngmtAgentTrap_8015 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No Disk Groups Found" ::= 136008015 mngmtAgentTrap_8016 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No Volumes Found" ::= 136008016 mngmtAgentTrap_8017 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No Physical Stores Found" ::= 136008017 mngmtAgentTrap_8018 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No Vdisks Found" ::= 136008018 mngmtAgentTrap_8019 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No Hosts Found" ::= 136008019 mngmtAgentTrap_8020 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Name already exists" ::= 136008020 mngmtAgentTrap_8021 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Folder is not empty" ::= 136008021 mngmtAgentTrap_8022 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Spares goal could not be met" ::= 136008022 mngmtAgentTrap_8023 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system object found" ::= 136008023 mngmtAgentTrap_8024 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system object not found" ::= 136008024 mngmtAgentTrap_8025 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "New Physical Store Detected But Not Found In Physical Store List" ::= 136008025 mngmtAgentTrap_8026 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "MldManager Handle is NULL" ::= 136008026 mngmtAgentTrap_8027 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "NscMngrInterface Handle is NULL" ::= 136008027 mngmtAgentTrap_8028 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "ScLockMngr Handle is NULL" ::= 136008028 mngmtAgentTrap_8029 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system initialization failed" ::= 136008029 mngmtAgentTrap_8030 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "MldMngr, NscMngrInterfaceMngr, or ScLockMngr Handle is NULL" ::= 136008030 mngmtAgentTrap_8031 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system initialization failed" ::= 136008031 mngmtAgentTrap_8032 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system discovery failed" ::= 136008032 mngmtAgentTrap_8033 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system already uninitialized or does not exist" ::= 136008033 mngmtAgentTrap_8034 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Total Storage Failed" ::= 136008034 mngmtAgentTrap_8035 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system is uninitialized" ::= 136008035 mngmtAgentTrap_8036 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Total Storage Available Failed" ::= 136008036 mngmtAgentTrap_8037 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Total Storage Occupied Failed" ::= 136008037 mngmtAgentTrap_8038 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Total Storage Free Failed" ::= 136008038 mngmtAgentTrap_8039 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Disk Group Failed" ::= 136008039 mngmtAgentTrap_8040 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Disk Group List Failed" ::= 136008040 mngmtAgentTrap_8041 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Disk Group Count Failed" ::= 136008041 mngmtAgentTrap_8042 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Create Volume Failed" ::= 136008042 mngmtAgentTrap_8043 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Volume Failed" ::= 136008043 mngmtAgentTrap_8044 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Volumes Failed" ::= 136008044 mngmtAgentTrap_8045 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Volumes Count Failed" ::= 136008045 mngmtAgentTrap_8046 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Vdisk Failed" ::= 136008046 mngmtAgentTrap_8047 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Vdisk List Failed" ::= 136008047 mngmtAgentTrap_8048 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Physical Store Failed" ::= 136008048 mngmtAgentTrap_8049 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Physical Stores Failed" ::= 136008049 mngmtAgentTrap_8050 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Physical Stores Count Failed" ::= 136008050 mngmtAgentTrap_8051 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Create Vdisk Failed" ::= 136008051 mngmtAgentTrap_8052 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Delete Vdisk Failed" ::= 136008052 mngmtAgentTrap_8053 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Device Addition Policy Failed" ::= 136008053 mngmtAgentTrap_8054 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Spares Current Failed" ::= 136008054 mngmtAgentTrap_8055 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Spares Goal Failed" ::= 136008055 mngmtAgentTrap_8056 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get storage system events failed" ::= 136008056 mngmtAgentTrap_8057 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Volume Replacement Delay Failed" ::= 136008057 mngmtAgentTrap_8058 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Set Device Addition Policy Failed" ::= 136008058 mngmtAgentTrap_8059 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Set Spares Goal Failed" ::= 136008059 mngmtAgentTrap_8060 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Set Volume Replacement Delay Failed" ::= 136008060 mngmtAgentTrap_8061 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Create controller Failed" ::= 136008061 mngmtAgentTrap_8062 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Update controller Failed" ::= 136008062 mngmtAgentTrap_8063 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Create Host Failed" ::= 136008063 mngmtAgentTrap_8064 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Discard Host Failed" ::= 136008064 mngmtAgentTrap_8065 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Host Failed" ::= 136008065 mngmtAgentTrap_8066 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Host List Failed" ::= 136008066 mngmtAgentTrap_8067 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Host Count Failed" ::= 136008067 mngmtAgentTrap_8068 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Presented Unit List Failed" ::= 136008068 mngmtAgentTrap_8069 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Presented Unit Count Failed" ::= 136008069 mngmtAgentTrap_8070 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Free View Failed" ::= 136008070 mngmtAgentTrap_8071 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system shutdown Failed" ::= 136008071 mngmtAgentTrap_8073 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Derived Unit List Failed" ::= 136008073 mngmtAgentTrap_8074 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Derived Unit Count Failed" ::= 136008074 mngmtAgentTrap_8075 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Vdisk list failed" ::= 136008075 mngmtAgentTrap_8076 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Get Vdisk count failed" ::= 136008076 mngmtAgentTrap_8077 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Error while building Vdisk root view" ::= 136008077 mngmtAgentTrap_8078 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Error while building host root view" ::= 136008078 mngmtAgentTrap_8079 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Error while building disk group root view" ::= 136008079 mngmtAgentTrap_8080 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Error while building hardware root view" ::= 136008080 mngmtAgentTrap_8081 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Specified time format is incorrect" ::= 136008081 mngmtAgentTrap_8082 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Error creating/opening time synchronization file." ::= 136008082 mngmtAgentTrap_8083 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "NSCList reordered." ::= 136008083 mngmtAgentTrap_8084 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "NscList mutex Get error" ::= 136008084 mngmtAgentTrap_8085 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage System is managed by another agent" ::= 136008085 mngmtAgentTrap_8086 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Memory allocation failure" ::= 136008086 mngmtAgentTrap_8087 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Failed to obtain list of DR Groups" ::= 136008087 mngmtAgentTrap_8088 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Failed to obtain count of DR Groups" ::= 136008088 mngmtAgentTrap_8089 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Failed to build DR Group view" ::= 136008089 mngmtAgentTrap_8090 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No Devices found on Controller Back End Loops" ::= 136008090 mngmtAgentTrap_9001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk File Open Error" ::= 136009001 mngmtAgentTrap_9002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk File Write Error" ::= 136009002 mngmtAgentTrap_9003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk File Read Error" ::= 136009003 mngmtAgentTrap_9004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk name too long" ::= 136009004 mngmtAgentTrap_9005 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk No String Error" ::= 136009005 mngmtAgentTrap_9006 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk No Object Error" ::= 136009006 mngmtAgentTrap_9007 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk still exists" ::= 136009007 mngmtAgentTrap_9008 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk Invalid Value" ::= 136009008 mngmtAgentTrap_9009 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "An outstanding command is still in progress for the Vdisk" ::= 136009009 mngmtAgentTrap_9010 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Requested Vdisk size exceeds the available size" ::= 136009010 mngmtAgentTrap_9011 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk size may be expanded but not reduced" ::= 136009011 mngmtAgentTrap_9012 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Operation on a fast Vdisk deletion completed" ::= 136009012 mngmtAgentTrap_9013 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Operation on a fast Vdisk creation completed" ::= 136009013 mngmtAgentTrap_9014 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Operation on a fast Vdisk size expansion completed" ::= 136009014 mngmtAgentTrap_9015 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk cache data lost error" ::= 136009015 mngmtAgentTrap_9016 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk data lost error resolved" ::= 136009016 mngmtAgentTrap_9017 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Operation rejected - The Vdisk has a sharing relationship with another object " ::= 136009017 mngmtAgentTrap_9018 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Operation on this Vdisk was rejected due to its degraded condition" ::= 136009018 mngmtAgentTrap_9019 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Operation on this Vdisk can only be performed if it is presented to a host" ::= 136009019 mngmtAgentTrap_9020 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Cache policies cannot be modified if Vdisk is presented to a host" ::= 136009020 mngmtAgentTrap_9021 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Allowed property changes successful. (Cache policy changes not allowed while Vdisk is presented to a host.)" ::= 136009021 mngmtAgentTrap_9022 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Requested redundancy type cannot be implemented with the current disk group condition." ::= 136009022 mngmtAgentTrap_9023 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Your Vdisk was created but cannot be presented at this time. It can be presented when it is fully allocated." ::= 136009023 mngmtAgentTrap_9025 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk device data lost error" ::= 136009025 mngmtAgentTrap_9026 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The most significant hex character in a World Wide LUN Name must be a 6." ::= 136009026 mngmtAgentTrap_9027 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Virtual disk cache and inoperative data lost error" ::= 136009027 mngmtAgentTrap_9028 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Virtual disk inoperative data lost error" ::= 136009028 mngmtAgentTrap_9029 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Virtual disk condition failed because of an inoperative data lost error." ::= 136009029 mngmtAgentTrap_9030 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk is a snapshot. The following properties cannot be changed: Preferred Path, Requested Size, Write-Back Cache Policy." ::= 136009030 mngmtAgentTrap_9031 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The World Wide LUN Name cannot be changed for a presented Vdisk Active member or snapshot." ::= 136009031 mngmtAgentTrap_9032 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unknown property, request rejected" ::= 136009032 mngmtAgentTrap_9033 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "This Vdisk was deleted as the indirect result of another user command." ::= 136009033 mngmtAgentTrap_9034 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The requested allocation policy cannot be satisfied. A different allocation policy is already in use by another snapshot in the same family." ::= 136009034 mngmtAgentTrap_9035 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The deletion of this Vdisk cannot take place. The original Vdisk that this is being snapcloned from is in a VRaid1 Meltdown state which must first be resolved." ::= 136009035 mngmtAgentTrap_9036 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Synchronous creation of virtual disk has been aborted due to an internal error. Switching to asynchronous mode to complete the virtual disk creation." ::= 136009036 mngmtAgentTrap_10001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage Object Broker Ready" ::= 136010001 mngmtAgentTrap_10004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage system is not initialized" ::= 136010004 mngmtAgentTrap_10006 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "SOB Memory Allocation Failure" ::= 136010006 mngmtAgentTrap_10010 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Your initialized system must have at least one disk group" ::= 136010010 mngmtAgentTrap_10011 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Cannot talk to all available controllers" ::= 136010011 mngmtAgentTrap_10012 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Command rejected - Folder is not empty" ::= 136010012 mngmtAgentTrap_10013 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Command rejected - Vdisk(s) or a data replication log are contained in this disk group" ::= 136010013 mngmtAgentTrap_10014 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Command rejected - Vdisk(s) are presented to this host" ::= 136010014 mngmtAgentTrap_10015 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Command rejected - This Vdisk has a sharing relationship with another object " ::= 136010015 mngmtAgentTrap_10017 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Command rejected - Number of disk groups will exceed the maximum allowable number " ::= 136010017 mngmtAgentTrap_10018 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Cannot access the password file " ::= 136010018 mngmtAgentTrap_10019 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Enterprise Login - Complete" ::= 136010019 mngmtAgentTrap_10020 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Command rejected - Disks in the group would go below the minimum required number." ::= 136010020 mngmtAgentTrap_10021 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Rediscovery of controllers - Complete" ::= 136010021 mngmtAgentTrap_10022 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to establish communication with controller, check all connections. " ::= 136010022 mngmtAgentTrap_10023 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Disk Group Data Lost Error Resolution Sequence 3 - Disk group resolved to normal" ::= 136010023 mngmtAgentTrap_10024 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Disk Group Data Lost Error Resolution Sequence 1 - Failed Vdisks marked for deletion" ::= 136010024 mngmtAgentTrap_10025 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Disk Group Data Lost Error Resolution Sequence 2 - Failed Vdisks deleted" ::= 136010025 mngmtAgentTrap_10026 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Disk Group Data Lost Error Resolution Sequence 3 - Disk group deleted" ::= 136010026 mngmtAgentTrap_10027 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Creating the Vdisk would exceed the maximum allowable Vdisk count" ::= 136010027 mngmtAgentTrap_10028 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Volume insufficient resources" ::= 136010028 mngmtAgentTrap_10029 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Process mutex is locked" ::= 136010029 mngmtAgentTrap_10030 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid URL request type" ::= 136010030 mngmtAgentTrap_10031 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid URL object type" ::= 136010031 mngmtAgentTrap_10035 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The snapshot/Snapclone license cannot be validated. Either the license key has not been entered, or there is a system communication failure." ::= 136010035 mngmtAgentTrap_10036 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "A data replication license cannot be validated. Either the license key has not been entered, or there is a system communication failure." ::= 136010036 mngmtAgentTrap_10037 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Object name should not be empty or exceed its maximum length" ::= 136010037 mngmtAgentTrap_10038 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Object comments exceeds maximum length" ::= 136010038 mngmtAgentTrap_10039 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Vdisk does not meet the requirements to be part of a DR group." ::= 136010039 mngmtAgentTrap_10040 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The Eva selected as the Destination for the DR group is invalid. Either it has a DR relationship with another EVA or it is not the same EVA that the source EVA presently has a DR relationship with." ::= 136010040 mngmtAgentTrap_10041 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Cannot group the specified disk device because the disk is already in a disk group." ::= 136010041 mngmtAgentTrap_10042 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Cannot ungroup the specified disk device because the disk is not grouped." ::= 136010042 mngmtAgentTrap_10043 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Object ID provided, or object type, is invalid for the requested operation." ::= 136010043 mngmtAgentTrap_10044 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Specified remote disk group does not exist." ::= 136010044 mngmtAgentTrap_11001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Agent startup complete" ::= 136011001 mngmtAgentTrap_11002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Agent shutdown complete" ::= 136011002 mngmtAgentTrap_11003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Insufficient memory to create a new object, Heap may be full!" ::= 136011003 mngmtAgentTrap_11004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Agent Startup Failed" ::= 136011004 mngmtAgentTrap_12001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Nsc Manager Interface No controllers Found" ::= 136012001 mngmtAgentTrap_12002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Nsc Manager Interface Index Out Of Range" ::= 136012002 mngmtAgentTrap_12003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Unable to process command at this time. Retry the command or check all connections. " ::= 136012003 mngmtAgentTrap_12004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Nsc Manager Interface Initialization Complete" ::= 136012004 mngmtAgentTrap_12005 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Nsc Manager Interface Initialization Failed" ::= 136012005 mngmtAgentTrap_12008 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No Disk Groups Available For Access" ::= 136012008 mngmtAgentTrap_13002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Notification Mngr Online" ::= 136013002 mngmtAgentTrap_13003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Notification Mngr Offline" ::= 136013003 mngmtAgentTrap_13004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "NM Startup Complete" ::= 136013004 mngmtAgentTrap_13007 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Notification Failed" ::= 136013007 mngmtAgentTrap_13009 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Notification Failed - Network Error" ::= 136013009 mngmtAgentTrap_13012 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "NM Prev Failed Notification Successfully Notified" ::= 136013012 mngmtAgentTrap_13015 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "NM SNMP Packet Failed" ::= 136013015 mngmtAgentTrap_13017 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "NM Memory Allocation Error" ::= 136013017 mngmtAgentTrap_13018 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "NM StorageCell handle is NULL" ::= 136013018 mngmtAgentTrap_13019 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "NM User defined event state file is empty" ::= 136013019 mngmtAgentTrap_13020 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "NM Notification Failed - Notification Matrix is NULL " ::= 136013020 mngmtAgentTrap_14001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "View Already Exists" ::= 136014001 mngmtAgentTrap_14002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "View Is Not Set" ::= 136014002 mngmtAgentTrap_14003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No View Object(s) Found" ::= 136014003 mngmtAgentTrap_14004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "View Index Is Out Of Range" ::= 136014004 mngmtAgentTrap_14005 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "View Object - Invalid Object Condition" ::= 136014005 mngmtAgentTrap_14006 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "View Object - Invalid Object Type" ::= 136014006 mngmtAgentTrap_14007 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "View List Pointer is NULL" ::= 136014007 mngmtAgentTrap_14008 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "View Object Pointer is NULL" ::= 136014008 mngmtAgentTrap_14009 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Building View List Object - Complete" ::= 136014009 mngmtAgentTrap_14010 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Building View List Object - Failed" ::= 136014010 mngmtAgentTrap_14012 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "View Find by UID Failed" ::= 136014012 mngmtAgentTrap_14013 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "View Find by Type Failed" ::= 136014013 mngmtAgentTrap_14017 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "View Find by Type by Name Failed" ::= 136014017 mngmtAgentTrap_15001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Tree View Symbol Not Found" ::= 136015001 mngmtAgentTrap_15002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Tree View Id Symbol Not Found" ::= 136015002 mngmtAgentTrap_15003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Tree Cursor Symbol Not Found" ::= 136015003 mngmtAgentTrap_15004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Tree Cursor Id Symbol Not Found" ::= 136015004 mngmtAgentTrap_15005 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Tree Sibling Symbol Not Found" ::= 136015005 mngmtAgentTrap_15006 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Tree Total Children Symbol Not Found" ::= 136015006 mngmtAgentTrap_15007 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Tree Expansion Symbol Not Found" ::= 136015007 mngmtAgentTrap_15008 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Tree Contraction Symbol Not Found" ::= 136015008 mngmtAgentTrap_15009 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Tree Invalid Descriptor String" ::= 136015009 mngmtAgentTrap_16001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Short Status - Reissue Command" ::= 136016001 mngmtAgentTrap_16004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Invalid Handle Set In Request Packet" ::= 136016004 mngmtAgentTrap_16005 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema No Pstore At Referenced Location" ::= 136016005 mngmtAgentTrap_16008 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema No Device Found" ::= 136016008 mngmtAgentTrap_16010 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Could Not Find SubEnclosure in Configuration List" ::= 136016010 mngmtAgentTrap_16012 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Non-specific error occurred " ::= 136016012 mngmtAgentTrap_16013 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Shelf WWN Could Not Be Accessed Through A Drive" ::= 136016013 mngmtAgentTrap_16014 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema EMU Failed To Enter Primary Mode" ::= 136016014 mngmtAgentTrap_16015 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema EMU Failed To Exit Primary Mode" ::= 136016015 mngmtAgentTrap_16016 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Downloaded File Does Not Contain Valid Fibre Channel Loader [status:1]" ::= 136016016 mngmtAgentTrap_16017 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Downloaded File Format Is Not Recognized [status:2]" ::= 136016017 mngmtAgentTrap_16018 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Incorrect Firmware In Downloaded File [status:3]" ::= 136016018 mngmtAgentTrap_16019 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Downloaded Loader is Too Large [status:4]" ::= 136016019 mngmtAgentTrap_16020 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Invalid Checksum [status:5]" ::= 136016020 mngmtAgentTrap_16021 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Previous Offset Plus Previous Length Not Equal To Current Offset [status:6]" ::= 136016021 mngmtAgentTrap_16022 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Downloaded Loader Terminated Incorrectly [status:7]" ::= 136016022 mngmtAgentTrap_16023 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema EMU Out Of Memory [status:8]" ::= 136016023 mngmtAgentTrap_16024 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema EMU CDB Timeout -- Download Aborted [status:9]" ::= 136016024 mngmtAgentTrap_16025 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema EMU Internal State Machine Error [status:10]" ::= 136016025 mngmtAgentTrap_16026 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema EMU Flash Erasure Failure [status:11]" ::= 136016026 mngmtAgentTrap_16027 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema EMU In Primary Mode - Cannot Download To Primary EMU [status:12]" ::= 136016027 mngmtAgentTrap_16028 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Previous Offset Plus Previous Length Greater Than Total Size [status:13]" ::= 136016028 mngmtAgentTrap_16029 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Current Total Size Different From Previous Total Size [status:14]" ::= 136016029 mngmtAgentTrap_16030 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Could Not Restore Reporting Group Number. Final Download Record Error" ::= 136016030 mngmtAgentTrap_16031 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Could Not Recovery From Invop. Invop Retries Exhausted" ::= 136016031 mngmtAgentTrap_16032 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Requested WWN Does Not Match Enclosure WWN" ::= 136016032 mngmtAgentTrap_16033 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema EMU Enclosure Services Error Occurred. EMU May Be Unavailable or Not Installed" ::= 136016033 mngmtAgentTrap_16034 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema SCSI Error Occurred While Trying To Communicate With EMU" ::= 136016034 mngmtAgentTrap_16035 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema Could Not Open EMU Firmware File" ::= 136016035 mngmtAgentTrap_16036 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema EMU Firmware File Name Is Null" ::= 136016036 mngmtAgentTrap_16037 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema EMU Firmware Download Retries Exhausted. Manual Download May Be Required" ::= 136016037 mngmtAgentTrap_16038 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema EMU Current Firmware Version Matches Upgrade Firmware Version. No Upgrade Will Be Performed." ::= 136016038 mngmtAgentTrap_16039 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema EMU Firmware Upgrade Success" ::= 136016039 mngmtAgentTrap_16040 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Ema EMU In Load State. Do Not Power Off. Reload EMU Firmware " ::= 136016040 mngmtAgentTrap_17001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Code Load Descriptor File Open Error" ::= 136017001 mngmtAgentTrap_17002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Code Load Descriptor File Parsing Error - Invalid Line" ::= 136017002 mngmtAgentTrap_17003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Code Load Image File Open Error, " ::= 136017003 mngmtAgentTrap_17004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Code Load Image File Error Getting File Size" ::= 136017004 mngmtAgentTrap_17005 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Code Load Image File Buffer Allocation Error" ::= 136017005 mngmtAgentTrap_17006 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Code Load Image File Read Error" ::= 136017006 mngmtAgentTrap_17007 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Code Load Drive Firmware Update Failed " ::= 136017007 mngmtAgentTrap_17008 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Code Load Drive Inquiry Failed" ::= 136017008 mngmtAgentTrap_17009 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Code Load Format Command Failed" ::= 136017009 mngmtAgentTrap_17012 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Code Load Get Physical Store Condition Failed" ::= 136017012 mngmtAgentTrap_17013 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Code Load Get Volume Condition Failed" ::= 136017013 mngmtAgentTrap_17014 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Code Load Drive Spin Up Error" ::= 136017014 mngmtAgentTrap_17015 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Code Load - Complete" ::= 136017015 mngmtAgentTrap_17016 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Code Load Disk Group Migration In Progress" ::= 136017016 mngmtAgentTrap_17017 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Code Load Unable To Code Load Disks Part Of A Group " ::= 136017017 mngmtAgentTrap_18001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Created Element Success" ::= 136018001 mngmtAgentTrap_18002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Created Storage Success" ::= 136018002 mngmtAgentTrap_18003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Created Storage Client Success" ::= 136018003 mngmtAgentTrap_18004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Set Storage Success" ::= 136018004 mngmtAgentTrap_18005 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Set Element Success" ::= 136018005 mngmtAgentTrap_18006 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Deleted Element Success" ::= 136018006 mngmtAgentTrap_18007 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Deleted Storage Success" ::= 136018007 mngmtAgentTrap_18008 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Deleted Storage Client Success" ::= 136018008 mngmtAgentTrap_18009 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Created Snapshot Success " ::= 136018009 mngmtAgentTrap_18010 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Created Clone Success" ::= 136018010 mngmtAgentTrap_18018 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Unable To Get The Lock" ::= 136018018 mngmtAgentTrap_18019 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Created PresentedUnit Success" ::= 136018019 mngmtAgentTrap_18022 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Create DiskGroup Success" ::= 136018022 mngmtAgentTrap_18024 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Create Folder Success" ::= 136018024 mngmtAgentTrap_18025 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Delete Folder Success" ::= 136018025 mngmtAgentTrap_18028 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Set Folder Success" ::= 136018028 mngmtAgentTrap_18034 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Invalid User Name Or Password Error" ::= 136018034 mngmtAgentTrap_18036 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Delete Presented Unit Success" ::= 136018036 mngmtAgentTrap_18038 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Set Diskgroup Success " ::= 136018038 mngmtAgentTrap_18039 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Set Disk Success" ::= 136018039 mngmtAgentTrap_18040 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Delete Storage Family Success " ::= 136018040 mngmtAgentTrap_18041 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Set Storage Family Success" ::= 136018041 mngmtAgentTrap_18042 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Control Memory Allocation Failure" ::= 136018042 mngmtAgentTrap_18045 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Element Codeload Success " ::= 136018045 mngmtAgentTrap_18047 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Disk Codeload Success" ::= 136018047 mngmtAgentTrap_18048 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Monitor Codeload Success" ::= 136018048 mngmtAgentTrap_18049 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Added Port WWID Success" ::= 136018049 mngmtAgentTrap_18050 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Set Storage Client Success" ::= 136018050 mngmtAgentTrap_18051 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Invalid Operation" ::= 136018051 mngmtAgentTrap_18052 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Deleted Port WWID Success" ::= 136018052 mngmtAgentTrap_18059 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Set Power Success" ::= 136018059 mngmtAgentTrap_18060 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Element Is Not Initialized" ::= 136018060 mngmtAgentTrap_18063 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Error trying to delete a disk group" ::= 136018063 mngmtAgentTrap_18065 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api A storage (Vdisk) operation is in progress. Try again later." ::= 136018065 mngmtAgentTrap_18066 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api The storage (Vdisk) condition is invalid. The storage may be in error. Try again later." ::= 136018066 mngmtAgentTrap_18067 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Error calling get Vdisk condition. Vdisk may be deleted. Try again later." ::= 136018067 mngmtAgentTrap_18068 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Invalid initialization of the API. Cannot start monitoring process. Storage system management limited." ::= 136018068 mngmtAgentTrap_18070 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api A command is currently under execution from another API call. Try again later." ::= 136018070 mngmtAgentTrap_18071 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api The server has not completed initialization, cannot process the request." ::= 136018071 mngmtAgentTrap_18073 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Removal of disk from disk group successful" ::= 136018073 mngmtAgentTrap_18074 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Disk(s) added to disk group successfully" ::= 136018074 mngmtAgentTrap_18075 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Modify monitor properties successful" ::= 136018075 mngmtAgentTrap_18076 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api Element name too long. Maximum is 20 characters." ::= 136018076 mngmtAgentTrap_18080 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api The snapshot/Snapclone license cannot be validated. Either the license key has not been entered, or there is a system communication failure." ::= 136018080 mngmtAgentTrap_18081 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Api The folder operation is not valid for the specified folder. Either the folder is a root folder and cannot be modified, or it is a disk group folder for which you should use 'Set Group' command." ::= 136018081 mngmtAgentTrap_20001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "LicMngr Memory Allocation Failure" ::= 136020001 mngmtAgentTrap_20002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "LicMngr Startup Complete" ::= 136020002 mngmtAgentTrap_20003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "LicMngr Startup Failed" ::= 136020003 mngmtAgentTrap_20004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "License successfully checked out" ::= 136020004 mngmtAgentTrap_20005 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "License checkout failed" ::= 136020005 mngmtAgentTrap_20011 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "License Line has an incorrect format" ::= 136020011 mngmtAgentTrap_20013 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "License Library runtime error" ::= 136020013 mngmtAgentTrap_20015 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Failed to retrieve Node WWN from storage system" ::= 136020015 mngmtAgentTrap_20016 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Failed to retrieve license list from MLD" ::= 136020016 mngmtAgentTrap_20017 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Failed to write license list to MLD" ::= 136020017 mngmtAgentTrap_20018 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "This license line appears to be invalid" ::= 136020018 mngmtAgentTrap_20019 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "MLD Manager Handle is NULL - unable to update MLD License List" ::= 136020019 mngmtAgentTrap_20020 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "LicMngr: Storage system handle is NULL" ::= 136020020 mngmtAgentTrap_20021 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The license you entered is a valid license but not for the Node WWN and/or firmware version on this controller pair" ::= 136020021 mngmtAgentTrap_20022 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Function name string is null or in an incorrect format" ::= 136020022 mngmtAgentTrap_20023 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Version string is null or in an incorrect format" ::= 136020023 mngmtAgentTrap_21001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager Image File Open Error" ::= 136021001 mngmtAgentTrap_21002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager Image File Buffer Allocation Error" ::= 136021002 mngmtAgentTrap_21003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager Image File Read Error" ::= 136021003 mngmtAgentTrap_21004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager Event File Write Error" ::= 136021004 mngmtAgentTrap_21006 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager Global Header Edc Compute Error" ::= 136021006 mngmtAgentTrap_21007 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager Image Header Edc Compute Error" ::= 136021007 mngmtAgentTrap_21008 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager Image Type Exceeds Max Image Count" ::= 136021008 mngmtAgentTrap_21009 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager Image Type Not Controller Image" ::= 136021009 mngmtAgentTrap_21010 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager Image Size Exceeded" ::= 136021010 mngmtAgentTrap_21011 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager Event File Open Error" ::= 136021011 mngmtAgentTrap_21012 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager Image Edc Compute Error" ::= 136021012 mngmtAgentTrap_21013 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager Begin Text Not Found" ::= 136021013 mngmtAgentTrap_21014 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager After Text Not Found" ::= 136021014 mngmtAgentTrap_21015 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager File Format Version Mismatch" ::= 136021015 mngmtAgentTrap_21016 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager Global Header Format Version Mismatch" ::= 136021016 mngmtAgentTrap_21017 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager Product Information Was Not Found" ::= 136021017 mngmtAgentTrap_21018 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager Event File Was Not Found" ::= 136021018 mngmtAgentTrap_21019 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "HSV Upgrade Manager All Images Match Versions Already Loaded" ::= 136021019 mngmtAgentTrap_22001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Trace: Unable to write management agent trace file" ::= 136022001 mngmtAgentTrap_22002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Trace: file write succeeded" ::= 136022002 mngmtAgentTrap_23002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY MINOR --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Diagnostic The view list has errors" ::= 136023002 mngmtAgentTrap_23003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY CRITICAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Diagnostic Memory allocation failure" ::= 136023003 mngmtAgentTrap_24001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Windows system error" ::= 136024001 mngmtAgentTrap_24002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Lock is already taken" ::= 136024002 mngmtAgentTrap_24003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Lock is not taken" ::= 136024003 mngmtAgentTrap_24004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Request timed out" ::= 136024004 mngmtAgentTrap_25001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No path to controller" ::= 136025001 mngmtAgentTrap_25002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Thread is not running" ::= 136025002 mngmtAgentTrap_25003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No physical stores" ::= 136025003 mngmtAgentTrap_25004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Loop context ID changed" ::= 136025004 mngmtAgentTrap_25005 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage Cell context ID changed" ::= 136025005 mngmtAgentTrap_25006 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Cache Write Failure" ::= 136025006 mngmtAgentTrap_25007 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Battery Disable Failure" ::= 136025007 mngmtAgentTrap_25008 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Drive Shelf Disable Failure" ::= 136025008 mngmtAgentTrap_25009 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Shutdown Both Restart And Power Off Requested" ::= 136025009 mngmtAgentTrap_25010 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Shutdown Drive Shelf Power Off But No Enclosure Power Off Requested" ::= 136025010 mngmtAgentTrap_25011 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Shutdown Disable Battery But No Enclosure Power Off Requested" ::= 136025011 mngmtAgentTrap_25012 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Shutdown Disable Battery But Shutdown Unconditional Requested" ::= 136025012 mngmtAgentTrap_25013 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Shutdown Delay Out Of Range" ::= 136025013 mngmtAgentTrap_25014 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid Storage Cell name" ::= 136025014 mngmtAgentTrap_25015 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Requested spares goal cannot be satisfied" ::= 136025015 mngmtAgentTrap_25016 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "No valid LDAD found" ::= 136025016 mngmtAgentTrap_25017 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Mismatched MLD size" ::= 136025017 mngmtAgentTrap_25018 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Codeload image file error" ::= 136025018 mngmtAgentTrap_25019 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Storage System is not initialized" ::= 136025019 mngmtAgentTrap_26002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Invalid data replication operation" ::= 136026002 mngmtAgentTrap_26005 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "DR group name exceeds maximum length" ::= 136026005 mngmtAgentTrap_26006 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "DR group created successfully" ::= 136026006 mngmtAgentTrap_26007 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Data replication invalid mode for DR Group create " ::= 136026007 mngmtAgentTrap_26008 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "A duplicate DR group name exists in the specified source or destination DR group." ::= 136026008 mngmtAgentTrap_26009 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Data replication invalid operation while DR Groups exist" ::= 136026009 mngmtAgentTrap_26010 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Data replication root folder does not exist" ::= 136026010 mngmtAgentTrap_26011 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "DR group discarded" ::= 136026011 mngmtAgentTrap_26012 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Data replication unknown remote storage system" ::= 136026012 mngmtAgentTrap_26013 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Data replication Error. A conflicting Vdisk name exists on the remote storage system." ::= 136026013 mngmtAgentTrap_26014 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Data Replication Error. Invalid Remote Vdisk Name specified." ::= 136026014 mngmtAgentTrap_26015 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Data Replication Error. Remote Vdisk size cannot be modified." ::= 136026015 mngmtAgentTrap_26016 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "Data Replication Error. Remote Vdisk should be unpresented to proceed with the discard/detach operation." ::= 136026016 mngmtAgentTrap_27001 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully initialized storage system. Command issued through XML Interface." ::= 136027001 mngmtAgentTrap_27002 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully created a virtual disk. Command issued through the XML Interface." ::= 136027002 mngmtAgentTrap_27003 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully created a disk group. Command issued through the XML Interface." ::= 136027003 mngmtAgentTrap_27004 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully created a DRM group. Command issued through the XML Interface." ::= 136027004 mngmtAgentTrap_27005 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully created a host. Command issued through the XML Interface." ::= 136027005 mngmtAgentTrap_27006 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully created a presented unit. Command issued through the XML Interface." ::= 136027006 mngmtAgentTrap_27007 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully created a virtual disk folder. Command issued through the XML Interface." ::= 136027007 mngmtAgentTrap_27008 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully created a host folder. Command issued through the XML Interface." ::= 136027008 mngmtAgentTrap_27009 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully created a disk group folder. Command issued through the XML Interface." ::= 136027009 mngmtAgentTrap_27010 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully created a DRM group folder. Command issued through the XML Interface." ::= 136027010 mngmtAgentTrap_27011 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully created a folder. Command issued through the XML Interface." ::= 136027011 mngmtAgentTrap_27012 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully created a snapshot. Command issued through the XML Interface." ::= 136027012 mngmtAgentTrap_27013 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully created a snapclone. Command issued through the XML Interface." ::= 136027013 mngmtAgentTrap_27014 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully uninitialized the storage system. Command issued through the XML Interface." ::= 136027014 mngmtAgentTrap_27015 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully deleted a virtual disk. Command issued through the XML Interface." ::= 136027015 mngmtAgentTrap_27016 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully deleted a disk group. Command issued through the XML Interface." ::= 136027016 mngmtAgentTrap_27017 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully deleted a DRM group. Command issued through the XML Interface." ::= 136027017 mngmtAgentTrap_27018 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully deleted a host. Command issued through the XML Interface." ::= 136027018 mngmtAgentTrap_27019 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully deleted a presented unit. Command issued through the XML Interface." ::= 136027019 mngmtAgentTrap_27020 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully deleted a virtual disk folder. Command issued through the XML Interface." ::= 136027020 mngmtAgentTrap_27021 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully deleted a host folder. Command issued through the XML Interface." ::= 136027021 mngmtAgentTrap_27022 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully deleted a disk group folder. Command issued through the XML Interface." ::= 136027022 mngmtAgentTrap_27023 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully deleted a DRM group folder. Command issued through the XML Interface." ::= 136027023 mngmtAgentTrap_27024 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully deleted a folder. Command issued through the XML Interface." ::= 136027024 mngmtAgentTrap_27025 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully deleted a snapshot. Command issued through the XML Interface." ::= 136027025 mngmtAgentTrap_27026 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a storage system. Command issued through the XML Interface." ::= 136027026 mngmtAgentTrap_27027 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a virtual disk. Command issued through the XML Interface." ::= 136027027 mngmtAgentTrap_27028 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a disk group. Command issued through the XML Interface." ::= 136027028 mngmtAgentTrap_27029 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a DRM group. Command issued through the XML Interface." ::= 136027029 mngmtAgentTrap_27030 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a host. Command issued through the XML Interface." ::= 136027030 mngmtAgentTrap_27031 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a presented unit. Command issued through the XML Interface." ::= 136027031 mngmtAgentTrap_27032 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a virtual disk folder. Command issued through the XML Interface." ::= 136027032 mngmtAgentTrap_27033 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a host folder. Command issued through the XML Interface." ::= 136027033 mngmtAgentTrap_27034 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a hardware root folder. Command issued through the XML Interface." ::= 136027034 mngmtAgentTrap_27035 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a disk group folder. Command issued through the XML Interface." ::= 136027035 mngmtAgentTrap_27036 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a DRM group folder. Command issued through the XML Interface." ::= 136027036 mngmtAgentTrap_27037 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a DRM group root folder. Command issued through the XML Interface." ::= 136027037 mngmtAgentTrap_27038 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a folder. Command issued through the XML Interface." ::= 136027038 mngmtAgentTrap_27039 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a snapshot. Command issued through the XML Interface." ::= 136027039 mngmtAgentTrap_27040 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a disk. Command issued through the XML Interface." ::= 136027040 mngmtAgentTrap_27041 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a disk shelf. Command issued through the XML Interface." ::= 136027041 mngmtAgentTrap_27042 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a controller. Command issued through the XML Interface." ::= 136027042 mngmtAgentTrap_27043 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a controller shelf. Command issued through the XML Interface." ::= 136027043 mngmtAgentTrap_27044 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully modified the properties of a cabinet. Command issued through the XML Interface." ::= 136027044 mngmtAgentTrap_27045 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully reserved an object. Command issued through the XML Interface." ::= 136027045 mngmtAgentTrap_27046 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "The element manager has successfully released an object. Command issued through the XML Interface." ::= 136027046 mngmtAgentTrap_27047 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "XML cache mutex timeout." ::= 136027047 mngmtAgentTrap_27048 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "XML cache memory allocation error." ::= 136027048 mngmtAgentTrap_27049 TRAP-TYPE ENTERPRISE compaq VARIABLES { hostName, scellNameDateTime, agentEventCode, agentEventDescription } --#TYPE "Management Agent Event" --#SUMMARY "Host %s : SCellNameTimeDate %s : EventCode %d : Description %s" --#MSG_FORMATTER "$V3V#Event Code: #" --#SEVERITY INFORMATIONAL --#CATEGORY "HP StorageWorks HSV Controller Events" DESCRIPTION "XML subsystem unknown error." ::= 136027049 END