-- SECTION 1: Top Level Definitions S5-AGENT-MIB DEFINITIONS ::= BEGIN -- 5000 Agent MIB Release 1.3.9 -- Revision 10/14/98 -- Copyright 1995-98 Bay Networks, Inc. -- All rights reserved. -- This Bay Networks SNMP Management Information Base Specification -- (Specification) embodies Bay Networks' confidential and -- proprietary intellectual property. Bay Networks retains all -- title and ownership in the Specification, including any -- revisions. -- This Specification is supplied "AS IS," and Bay Networks makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. -- Imports IMPORTS IpAddress, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB s5Agent FROM S5-ROOT-MIB TimeIntervalSec, IpxAddress, MacAddress FROM S5-TCS-MIB; -- Agent Groups s5AgentHw OBJECT IDENTIFIER ::= { s5Agent 1 } s5AgentInfo OBJECT IDENTIFIER ::= { s5Agent 2 } s5AgentMgmt OBJECT IDENTIFIER ::= { s5Agent 3 } -- SECTION 2: MIB Objects -- Hardware Information s5AgMyGrpIndx OBJECT-TYPE SYNTAX INTEGER (1..32767) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the group containing the agent." ::= { s5AgentHw 1 } s5AgMyComIndx OBJECT-TYPE SYNTAX INTEGER (1..32767) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the component containing the agent." ::= { s5AgentHw 2 } -- Global Information s5AgentGbl OBJECT IDENTIFIER ::= { s5AgentInfo 1 } s5AgInfoReBoot OBJECT-TYPE SYNTAX INTEGER { other(1), running(2), restart(3), reboot(4), reset(5), download(6), downloadAndRestart(7), downloadAndReboot(8), downloadAndReset(9) } ACCESS read-write STATUS mandatory DESCRIPTION "Action object to reboot the agent. The following values can only be read: other(1).....agent in unknown or other state running(2)...agent running The following values can be written: restart(3)...restart agent (i.e., jump to beginning of agent code) reboot(4)....start boot sequence for agent (i.e., jump to beginning of boot firmware) reset(5).....do a hardware reset download(6)..............activate download of a new agent downloadAndRestart(7)....activate download of a new agent and restart downloadAndReboot(8).....activate download of a new agent and reboot downloadAndReset(9)......activate download of a new agent and reset If s5AgInfoScheduleBootTime is set in the same PDU as s5AgInfoReBoot, the action specified occurs when the scheduled time reaches zero; otherwise, the action occurs immediately. The agent does best efforts to return a response before the action occurs. If any of the combined download actions are requested, neither action occurs until the expiry of s5AgInfoScheduleBootTime, if set." ::= { s5AgentGbl 1 } s5AgInfoWriteCfg OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), write(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Action object to cause current configuration settings to be written to local nonvolatile storage. The following values can only be read: other(1)...some unknown or other state valid(2)...contents valid The following value can be written: write(3)...write configuration settings to local storage (such as nonvol) If the write operation write fails, then the agent will return error 'genErr' on the SET." ::= { s5AgentGbl 2 } s5AgInfoMgmtProtocolNxtBoot OBJECT-TYPE SYNTAX INTEGER { other(1), ipOnly(2), ipxOnly(3), ipAndIpx(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The transport protocol(s) to use after the next boot of the agent. The following value is read-only: other(1)....unknown or some other protocol The following value is read-write: ipOnly(2).....only IP ipxOnly(3)....only IPX ipAndIpx(4)...IP and IPX." ::= { s5AgentGbl 3 } s5AgInfoMgmtProtocolCur OBJECT-TYPE SYNTAX INTEGER { other(1), ipOnly(2) , ipxOnly(3), ipAndIpx(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The current transport protocol(s) that are being supported by the agent. The following value is read-only: other(1)....unknown or some other protocol The following value is read-write: ipOnly(2).....only IP ipxOnly(3)....only IPX ipAndIpx(4)...IP and IPX. When the IP protocol stack is not enabled, the agent will not respond to PING or SNMP requests over IP. When the IPX protocol stack is not enabled, the agent will not respond to diagnostic SAP or SNMP requests over IPX. It is suggested that NMS not disable the transport they are using." ::= { s5AgentGbl 4 } s5AgInfoBootMode OBJECT-TYPE SYNTAX INTEGER { other(1), local(2), net(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The source for initial protocol configuration information at next boot. For IP, a setting of net(3) means that BOOTP will be used to get the agent's IP address(es), load server address, and configuration file name. For IPX, a setting of net(3) means SAP will be used to get the agent's Novell network number(s), and the configuation filename will be loaded from local storage (note - the load server address is not needed in a Novell network). The following value is read-only: other(1).....not applicable or some other case The following values are read-write: local(2).....don't use the network net(3).......try using the network and if that fails then use protocol configuration information from local storage. Note: The load server address is not configurable and is not available in this MIB object on a Novell network." ::= { s5AgentGbl 5 } s5AgInfoCfgLoadMode OBJECT-TYPE SYNTAX INTEGER { other(1), local(2), net(3), locAsBk(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The source from which to load configuration information at next boot. The following value is read-only: other(1)...not applicable or some other case The following values are read-write: local(2).....get from local storage net(3).......load from the network locAsBk(4)...try using network and if it fails then use local information. When local(2) is specified, the configuration information is loaded from local storage. If the local configuration is not valid (checks for ip = 0.0.0.0), then BOOTP is used for the IP stack. (In IPX only mode, the IP address could be 0.0.0.0 and IPX does not rely on the IP address. The agent checks the IPX address, and if the network number of the IPX address is equal to 0 the agent uses SAP). When net(3) is specified, the configuration information will be downloaded from the network only. The configuration information will never be loaded from local storage, even if downloading fails and the local configuration information exists. When locAsBk(4) is specified, a download of the configuration information will be tried over the network. If the network download fails then the configuration information will be loaded from local storage." ::= { s5AgentGbl 6 } s5AgInfoImgLoadMode OBJECT-TYPE SYNTAX INTEGER { other(1), local(2), net(3), locAsBk(4), netIfNewer(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The source from which to load the agent image at next boot. The following value is read-only: other(1)...not applicable or some other case The following values are read-write: local(2)........get from local storage net(3)..........load from the network locAsBk(4)......try using network and if it fails then use local information. netIfNewer(5)...try loading image over the net. If can load image, and it is newer than the local image, then use it. Otherwise, use local image. If the local image is not valid, the setting will be net(3) and cannot be changed to local(2), or locAsBk(4) until a valid image file is loaded (i.e., error 'badValue' will be returned on SETS with value other than net(3)). When the local image is not valid and the network download of the image fails, the entire boot process will be repeated. When local(2) is specified, the image will be loaded from local storage. When net(3) is specified, the image will be downloaded from the network only. The image file will never be loaded from local storage, even if downloading fails and the local image exists. When locAsBk(4) is specified, a download of the image will be tried over the network. If the network download fails then the image is loaded from local storage. When netIfNewer(5) is specified, a download of the image will be tried over the network. If successful, it will then be compared to the image stored in local storage. The most recent version of the two will be used. If the local image is not valid, the network will always be used. If the network download fails then the image is loaded from the local storage." ::= { s5AgentGbl 7 } s5AgInfoImgSaveMode OBJECT-TYPE SYNTAX INTEGER { notAvail(1), writeIfDiff(2), writeIfNewer(3), noWrite(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates what to do with the image (when loaded from the network) on the next boot. The following value can only be read: notAvail(1)...the save operation is not available The following values can be written (and read) if the device supports this capability: writeIfDiff(2)....save image to local storage at next boot if image is different from saved contents writeIfNewer(3)...save image to local storage at next boot if image is newer than saved contents. noWrite(4)........do not save image to local storage at next boot, even if image is newer or different." ::= { s5AgentGbl 8 } s5AgInfoImgSaveStatus OBJECT-TYPE SYNTAX INTEGER { notAvail(1), noSave(2), saved(3), saveFailed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates what happened to the image file on the last boot. The following values are returned: notAvail(1).....the save operation is not available noSave(2).......image not saved since image was not asked to be saved, or image was not loaded from the network saved(3)........image saved saveFailed(4)...tried to save image, but failed" ::= { s5AgentGbl 9 } s5AgInfoVer OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "The version of the agent in the form 'major.minor.maintenance[letters]'. This is an alias for the value of the object s5ChasStoreCntntVer for the RAM of the module containing the agent." ::= { s5AgentGbl 10 } s5AgInfoLocStorVer OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "The version of the agent image saved in local storage such as flash memory in the form 'major.minor.maintenance[letters]'. If not known or not available, then the value is a zero length string. This is an alias for the value of the object s5ChasStoreCntntVer for the local storage of the module containing the agent." ::= { s5AgentGbl 11 } s5AgInfoNxtBootDfltGwAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the default gateway (router) for the agent to use after the next boot. (NOTE: the current default router is the value of object s5AgInfoCurDfltGwAddr (or ipRouteNextHop.0.0.0.0).) If not used, then this object has the value of 0.0.0.0." ::= { s5AgentGbl 12 } s5AgInfoCurDfltGwAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the current default gateway (router). (NOTE: this is an alias for the object ipRouteNextHop in the row of the table ipRouteTable which has object ipRouteDest with a value of 0.0.0.0.) If not used, then this object has the value of 0.0.0.0." ::= { s5AgentGbl 13 } s5AgInfoDramUsage OBJECT-TYPE SYNTAX INTEGER (-1..100) ACCESS read-only STATUS mandatory DESCRIPTION "An indication of the percentage of DRAM currently in use by this agent. If this information is not available the agent shall return -1, otherwise the percentage of DRAM in use is returned as an integer between 0 and 100. The percentage is defined as the DRAM currently used by this agent divided by the total DRAM available to this agent." ::= { s5AgentGbl 14 } s5AgInfoLoadProtocolNxtBoot OBJECT-TYPE SYNTAX INTEGER { other(1), ipOnly(2), ipxOnly(3), auto(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The transport protocol(s) over which the agent is to use to load the configuration information and the agent image at the next boot of the agent. The following value is read-only: other(1)....unknown or some other protocol The following values are read-write: ipOnly(2)....use load protocol over IP ipxOnly(3)...use load protocol over IPX auto(4)......try using the IP load function and if that fails then use IPX load function. If the IPX load function also fails, repeat the same process until one or the other protocol succeeds." ::= { s5AgentGbl 15 } s5AgInfoLoadProtocolLast OBJECT-TYPE SYNTAX INTEGER { reserved(1), ip(2), ipx(3), local(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The transport protocol over which the agent image and configuration information were last loaded. The following values are read-only: reserved(1)...reserved ip(2).........gotten from the network using a load protocol over IP ipx(3)........gotten from the network using a load protocol over IPX local(4)......loaded from local storage." ::= { s5AgentGbl 16 } s5AgInfoSlotScope OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "This object contains information about all the slots an agent can manage. The value is encoded in an octet string. One byte has information about 8 slots. If a bit is set then agent can manage the corresponding slot. Byte 1 will have information about slots 1-8, byte 2 will have information about slots 9-16, and so on. For example an agent that can manage slots 2-7 in a 14 slot chassis should have the value : 8d:00 (0111 1110 0000 0000) If an agent returns a string of size 0, then it can manage all slots in chassis." ::= { s5AgentGbl 17 } s5AgInfoImgType OBJECT-TYPE SYNTAX INTEGER { other(1), typeA(2), typeB(3), typeC(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the type of agent image. This object is meant to distinguish between agents having the same version number running on the same hardware, but with dissimilar functionality. Following are examples of possible values for various enumerations. other(1) ....... A unique agent eg., 5310A, 5dn310 etc typeA(2) ....... fusion basic agent. typeB(2) ....... fusion advanced agent." ::= { s5AgentGbl 18 } s5AgInfoScheduleBootTime OBJECT-TYPE SYNTAX INTEGER (0..10080) ACCESS read-write STATUS mandatory DESCRIPTION "The time, measured in minutes, remaining until the action(s) set by s5AgInfoReBoot will be performed. This value must be set in the same set request as the value of s5AgInfoReBoot; otherwise, a badValue error is returned. If this value has been set, the number returned will count down to zero, and the time remaining in minutes will be rounded up to the next whole minute. Actions set via s5AgInfoReBoot can be scheduled for up to seven days in advance. 7 * 24 * 60 equals the maximum settable value of 10080. If this attribute has not been set, a value of zero should be returned." ::= { s5AgentGbl 19 } s5AgInfoScheduleBootCancel OBJECT-TYPE SYNTAX INTEGER { other(1), cancel(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Cancel a scheduled s5AgInfoReboot action. The following value is read-only: other(1)...not applicable or some other case This is always the value that return when read. The following values are read-write: cancel(2)...cancel a scheduled boot. Setting this attribute to cancel(2) sets s5AgInfoReBoot to running(2) and s5AgInfoScheduleBootTime to zero." ::= { s5AgentGbl 20 } s5AgInfoNumBootBanks OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The number of local storage locations (or flash memory banks) available on this device for operational code images. Devices without local image capability or not supporting this attribute shall return a value of 0." ::= { s5AgentGbl 21 } s5AgInfoNextBootBank OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The source of the image to be loaded upon the next boot of the device. If a value is set larger than s5AgInfoNumBootBanks, a badValue error should be returned. Devices without local image capability or not supporting this attribute shall return a value of 0." ::= { s5AgentGbl 22 } s5AgInfoDstLoadBank OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The local storage bank where the next system image image is downloaded to. Devices without local image capability or not supporting this attribute shall return a value of 0." ::= { s5AgentGbl 23 } s5AgInfoFileAction OBJECT-TYPE SYNTAX INTEGER { other(1), dnldConfig(2), dnldImg(3), upldConfig(4), upldImg(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to download or upload a config file or an image file. In read operation, if no action taken since the boot up, it will return other(1). Otherwise it will return the latest action such as dnldConfig(2), dnldImg(3), upldConfig(4) and upldImg(5). In write operation, the values that can be written are: dnldConfig(2) ... download a config file to a device. The new config file will not take effect until the next boot cycle of the device. dnldImg(3) ...... download an image to a device. upldConfig(4) ... upload a config file to a server from a device. The config file contains the current MIB object values of the device. upldImg(5) ...... upload a image from a device to a server" ::= {s5AgentGbl 24} s5AgInfoFileStatus OBJECT-TYPE SYNTAX INTEGER { other(1), inProgress (2), success (3), fail (4) } ACCESS read-only STATUS mandatory DESCRIPTION "This object is used to get the status of the latest action as shown by s5AgInfoFileAction. The values that can be read are: other(1) ......... if no action taken since the boot up inProgress (2) ... the operation is in progress success (3) ...... the operation succeeds. fail (4) ......... the operation is failed." ::= {s5AgentGbl 25} -- Agent's Interface Information Table s5AgMyIfTable OBJECT-TYPE SYNTAX SEQUENCE OF S5AgMyIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that provides additional information about the agent's interfaces. The number of entries in the table is determined by the number of interfaces on the agent." ::= { s5AgentInfo 2 } s5AgMyIfEntry OBJECT-TYPE SYNTAX S5AgMyIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row in the table of additional information about the agent's interfaces. Entries can not be created or deleted via SNMP requests." INDEX { s5AgMyIfIndx } ::= { s5AgMyIfTable 1 } S5AgMyIfEntry ::= SEQUENCE { s5AgMyIfIndx INTEGER, s5AgMyIfNxtBootIpAddr IpAddress, s5AgMyIfNxtBootNetMask IpAddress, s5AgMyIfCfgFname DisplayString, s5AgMyIfLdSvrAddr IpAddress, s5AgMyIfImgFname DisplayString, s5AgMyIfValidFlag INTEGER, s5AgMyIfNxtBootIpxAddr IpxAddress, s5AgMyIfBootRouterAddr IpAddress, s5AgMyIfMacAddr MacAddress } s5AgMyIfIndx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the interface. This has the same value as ifIndex for the interface." ::= { s5AgMyIfEntry 1 } s5AgMyIfNxtBootIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "For the next boot, the IP address of the the interface. If not used, then the value is 0.0.0.0. (NOTE: the current IP address for the interface is found in table ipAddrTable and in table s5AgOthIfTable.)" ::= { s5AgMyIfEntry 2 } s5AgMyIfNxtBootNetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "For the next boot, the subnet mask for the interface. If not used, then the value is 0.0.0.0. (NOTE: the current subnet mask for the interface is found in table ipAddrTable.)" ::= { s5AgMyIfEntry 3 } s5AgMyIfCfgFname OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Name of the configuration file currently associated with the interface. When not used, the value is a zero length string." ::= { s5AgMyIfEntry 4 } s5AgMyIfLdSvrAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the load server for the configuration file and/or the image file. If not used, then the value is 0.0.0.0" ::= { s5AgMyIfEntry 5 } s5AgMyIfImgFname OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) ACCESS read-write STATUS mandatory DESCRIPTION "Name of the image file(s) currently associated with the interface. Some agents in special situations may support a value which contains multiple file names instead of a single file name. Multiple names are specified as a list of file names separated by semicolons (;). When the object is not used, the value is a zero length string." ::= { s5AgMyIfEntry 6 } s5AgMyIfValidFlag OBJECT-TYPE SYNTAX INTEGER { valid(1), invalid(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if the configuration and/or image file(s) were downloaded from this interface and if the file names have not been changed. The following values can be read: valid(1).....configuration and/or image file(s) downloaded from this interface are currently in use invalid(2)...cfg and/or image files downloaded from this interface are not in use (this may also mean that there are no files downloaded from this interface)." ::= { s5AgMyIfEntry 7 } s5AgMyIfNxtBootIpxAddr OBJECT-TYPE SYNTAX IpxAddress ACCESS read-only STATUS mandatory DESCRIPTION "For the next boot, the IPX address of the the interface. If the IPX protocol is not used, then the value is 00000000:000000000000. NOTE: The current IPX address for the interface is found in table s5AgOthIfTable." ::= { s5AgMyIfEntry 8 } s5AgMyIfBootRouterAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the boot router for the configuration file and/or the image file. If not used, then the value is 0.0.0.0" ::= { s5AgMyIfEntry 9 } s5AgMyIfMacAddr OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address of the interface. The value is 00:00:00:00:00:00 if there is no interface." ::= { s5AgMyIfEntry 10} -- Other Agents' Interface Information Table s5AgOthIfTable OBJECT-TYPE SYNTAX SEQUENCE OF S5AgOthIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table that provides information about each interface for each agent in the chassis. The number of entries in the table is determined by the number of agents in the chassis and their configuration." ::= { s5AgentInfo 3 } s5AgOthIfEntry OBJECT-TYPE SYNTAX S5AgOthIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row in the table of information about interface information for all agents in the chassis. Entries can not be created or deleted via SNMP requests." INDEX { s5AgOthIfGrpIndx, s5AgOthIfComIndx, s5AgOthIfIndx } ::= { s5AgOthIfTable 1 } S5AgOthIfEntry ::= SEQUENCE { s5AgOthIfGrpIndx INTEGER, s5AgOthIfComIndx INTEGER, s5AgOthIfIndx INTEGER, s5AgOthIfIpAddr IpAddress, s5AgOthIfIpxAddr IpxAddress } s5AgOthIfGrpIndx OBJECT-TYPE SYNTAX INTEGER (1..32767) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the group containing the component containing the agent." ::= { s5AgOthIfEntry 1 } s5AgOthIfComIndx OBJECT-TYPE SYNTAX INTEGER (1..32767) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the component in the group containing the agent." ::= { s5AgOthIfEntry 2 } s5AgOthIfIndx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the interface. This is the same value as ifIndex." ::= { s5AgOthIfEntry 3 } s5AgOthIfIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of the interface. If not used, then the value is 0.0.0.0." ::= { s5AgOthIfEntry 4 } s5AgOthIfIpxAddr OBJECT-TYPE SYNTAX IpxAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IPX address of the interface. If the IPX protocol is not used, then the value is 00000000:000000000000." ::= { s5AgOthIfEntry 5 } -- IP Router Aging And Default Router Selection Information s5AgIpRtrDefaultTimeToLive OBJECT-TYPE SYNTAX TimeIntervalSec (60..3600) ACCESS read-write STATUS mandatory DESCRIPTION "The lifetime of IP router entries in seconds. The maximum length of time that a IP router is to be considered alive in the absence of further positive advice. The default lifetime is used for routers learned through IP router protocols that do not specify a lifetime (e.g. statically configured, ICMP redirects)." DEFVAL { 540 } -- 9 minutes ::= { s5AgentInfo 4 } s5AgIpDefaultRtrSelectionMode OBJECT-TYPE SYNTAX INTEGER { other(1), config(2), static(3), dynamic(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The method used to select a default IP router. The following value is read-only: other(1).......not applicable or other case The following values are read-write: config(2).....use configured primary default router. If no primary default router is specified, there will be no default IP route. static(3).....A default router will be chose from the routers known to be up and that have been configured. dynamic(4)....ICMP router discovery as per RFC 1256 is performed and the router with the highest preference level is chosen as default router." DEFVAL { dynamic } ::= { s5AgentInfo 5 } s5AgIpRtrDiscoverySolicitMode OBJECT-TYPE SYNTAX INTEGER { multicast(1), broadcast(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The router discovery solicitation mode to use when the default router selection mode is dynamic. This solicitation mode determines the IP address for ICMP router solicitations (see RFC 1256): multicast(1)..router solicitations are sent to the all-routers multicast address (224.0.0.2) broadcast(2)..router solicitations are sent to the limited broadcast address (255.255.255.255)." DEFVAL { broadcast} ::= { s5AgentInfo 6 } -- Agent's Data Collection Table s5AgDataCollectTable OBJECT-TYPE SYNTAX SEQUENCE OF S5AgDataCollectEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of control information and statistics for the data collection (promiscuous data capturing) per source of detection." ::= { s5AgentInfo 7 } s5AgDataCollectEntry OBJECT-TYPE SYNTAX S5AgDataCollectEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row in the data collection table. Entries can not be created or deleted via SNMP." INDEX { s5AgDataCollectIfIndex } ::= { s5AgDataCollectTable 1 } S5AgDataCollectEntry ::= SEQUENCE { s5AgDataCollectIfIndex INTEGER, s5AgDataCollectSnTimeStamp TimeTicks, s5AgDataCollectNetworkAddrStatus INTEGER } s5AgDataCollectIfIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "An integer value representing the source that collects data from the network. A value greater than zero is the index of the agent's interface on the NMM. This is the same value as ifIndex for the interface. A value of zero indicates data collection via best available efforts (other than NMM's interfaces)." ::= { s5AgDataCollectEntry 1 } s5AgDataCollectSnTimeStamp OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime at the last time a node was added or deleted from the Show Node table." ::= { s5AgDataCollectEntry 2 } s5AgDataCollectNetworkAddrStatus OBJECT-TYPE SYNTAX INTEGER { alwaysOff(1), on(2), off(3) } ACCESS read-write STATUS mandatory DESCRIPTION "A switch to enable or disable the collecting of network layer addresses for the network address mapping table (s5CmNetAddrTable ). The following value is read-only: alwaysOff(1)..data source is not capable of collecting or decoding network addresses The following values are read-write if the data source is capable of collecting network addresses: on(2).........packet decoding is enabled off(3)........packet decoding is disabled or not supported." DEFVAL { on } -- if packet collection is possible ::= { s5AgDataCollectEntry 3 } -- Authentication Trap VarBinds s5AgUnAuthIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the IP address of the last station that tried to access this agent with an invalid community string. This object is used as a VarBind in an Authentication Trap PDU. A get request will return the last value used, and will return the null address 0.0.0.0 if no IP authentication traps have been sent." ::= { s5AgentInfo 8 } s5AgUnAuthIpxAddr OBJECT-TYPE SYNTAX IpxAddress ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the IPX address of the last station that tried to access this agent with an invalid community string. This object is used as a VarBind in an Authentication Trap PDU. A get request will return the last value used, and will return the null address of all zeros if no IPX authentication traps have been sent." ::= { s5AgentInfo 9 } s5AgUnAuthComm OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the community string of the last unauthenticated attempt to access this agent. This object is used as a VarBind in an Authentication Trap PDU. A get request will return the last value used, and will return the null string if no authentication traps have been sent." ::= { s5AgentInfo 10 } s5AgTrapFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF S5AgTrapFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Agent Trap filter configuration table." ::= { s5AgentInfo 11 } s5AgTrapFilterEntry OBJECT-TYPE SYNTAX S5AgTrapFilterEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of trap filter entries that determine the filtering of traps. For example, an instance of the s5AgtTrapFilterStatus will be named s5AgTrapFilterStatus.8" INDEX { s5AgTrapFilterIndex } ::= { s5AgTrapFilterTable 1 } S5AgTrapFilterEntry ::= SEQUENCE { s5AgTrapFilterIndex INTEGER, s5AgTrapFilterTrapOID OBJECT IDENTIFIER, s5AgTrapFilterTrapInitiator1 INTEGER, s5AgTrapFilterTrapInitiator2 INTEGER, s5AgTrapFilterTrapInitiator3 INTEGER, s5AgTrapFilterStatus INTEGER, s5AgTrapFilterDelayTime INTEGER, s5AgTrapEntryStatus INTEGER } s5AgTrapFilterIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies an entry in the s5AgTrapFilterTable." ::= { s5AgTrapFilterEntry 1 } s5AgTrapFilterTrapOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "The OID of the trap. This variable is requried for row creation." ::= { s5AgTrapFilterEntry 2 } s5AgTrapFilterTrapInitiator1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A value that determines the first condition for filtering a trap.This entry is the value of the first varbind for a particular trap in most cases. We need to specify every initiator that represents the corresponding trap variable for each trap. If the value of this initiator is 0 (wildcard or don't care), it means that it can represent all possible values for this initiator. The trap-filter design and functional spec. provides a more detailed explanation on this subject." ::= { s5AgTrapFilterEntry 3 } s5AgTrapFilterTrapInitiator2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A value that determines the second condition for filtering a trap. This entry is the value of the second varbind for most traps. If the value of this initiator is 0 (wildcard or don't care), it means that it can represent all possible values for this initiator. If a trap has only one varbind, this entry should be set to 0." ::= { s5AgTrapFilterEntry 4 } s5AgTrapFilterTrapInitiator3 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A value that determines the third condition for filtering a trap. This entry is the value of the third varbind for most traps. If the value of this initiator is 0(wildcard or don't care), it means that it can represent all possible values for this initiator. If a trap has only one or two varbinds, this entry should be set to 0." ::= { s5AgTrapFilterEntry 5 } s5AgTrapFilterStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether this trap is enabled or not. enabled(1) indicates that if this type of event occurs, a trap that is generated will be queued for transmit. disabled(2) indicates that if this trap if generated, it will not be queued for transmit and s5AgTrapFilterDelayTime is not valid." ::= { s5AgTrapFilterEntry 6 } s5AgTrapFilterDelayTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The time delay period required to be met, between each consecutive occurences of this event. Traps recieved within this period will be dropped." ::= { s5AgTrapFilterEntry 7 } s5AgTrapEntryStatus OBJECT-TYPE SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) } ACCESS read-write STATUS mandatory DESCRIPTION "A manager is restricted to change the state of an entry base on the following table: create under To: valid Request Creation invalid From: valid OK NO OK OK createRequest N/A N/A N/A N/A underCreation OK NO OK OK invalid NO NO NO OK nonExistent NO OK NO OK In the table above, it is not applicable to change the state from createRequest to any other states. When the status of a table entry is set to the value of invalid(4), the entry will be removed from the table. If an entry has been in the underCreation(3) state for more than 10 minutes, it will be set to invalid(4) and subsequently removed from the table. This variable is requried for row creation." ::= { s5AgTrapFilterEntry 8 } -- change '_' to '-' for enum named label -- yyang 11/30/98 s5AgTrapFilterGlobalStatus OBJECT-TYPE SYNTAX INTEGER{ enable-all(1), disable-all(2), enable-all-and-use-table(3), disable-all-and-use-table(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This value is the status of all the traps that supported by this trap-filter system. If the value is 1 (enable all) , all traps in the system are enabled. If the value is 2 (disable all), all traps in the system are disabled. If the value is 3 (enable-all-and-use-table) all traps are enabled except for traps that are disabled in the s5AgTrapFilterTable are disabled. If the value is 4 (disable-all-and-use-table) all traps are disabled except for traps that are enabled in the s5AgTrapFilterTable are enabled." ::= { s5AgentInfo 12 } -- Trap Receiver Table s5AgTrpRcvrMaxEnt OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of rows in the trap receiver table." ::= { s5AgentMgmt 1 } s5AgTrpRcvrCurEnt OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The current number of rows in the trap receiver table." ::= { s5AgentMgmt 2 } s5AgTrpRcvrNext OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the next available row to be created in the trap receiver table. A value of zero means that the table is full and no more rows can be added." ::= { s5AgentMgmt 3 } s5AgTrpRcvrTable OBJECT-TYPE SYNTAX SEQUENCE OF S5AgTrpRcvrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of managers which to send traps." ::= { s5AgentMgmt 4 } s5AgTrpRcvrEntry OBJECT-TYPE SYNTAX S5AgTrpRcvrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row in the trap receiver table. The column s5AgTrpRcvrStatus is used to create and delete rows in the table. Creation requires a SET PDU with objects s5AgTrpRcvrStatus, s5AgTrpRcvrAddrType, s5AgTrpRcvrNetAddr, and s5AgTrpRcvrComm for the new row." INDEX { s5AgTrpRcvrIndx } ::= { s5AgTrpRcvrTable 1 } S5AgTrpRcvrEntry ::= SEQUENCE { s5AgTrpRcvrIndx INTEGER, s5AgTrpRcvrStatus INTEGER, s5AgTrpRcvrAddrType INTEGER, s5AgTrpRcvrNetAddr OCTET STRING, s5AgTrpRcvrComm OCTET STRING, s5AgTrpRcvrAgeTime TimeIntervalSec } s5AgTrpRcvrIndx OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the row in the table." ::= { s5AgTrpRcvrEntry 1 } s5AgTrpRcvrStatus OBJECT-TYPE SYNTAX INTEGER { other(1), valid(2), ignore(3), delete(4), create(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to create and delete rows in the table and control if they are used. The values that can be written are: valid(2)....makes an existing row valid - can only be written to change the value from ignore(3) ignore(3)...don't use this entry to send traps to at this time delete(4)...deletes the row create(5)...creates a new row - only value that can be used to create a row in the table If the row exists, then a SET with value of create(5) returns error 'badValue'. Deleted rows go away immediately. The following values can be returned on reads: other(1)....some other case valid(2)....the row exists and is valid ignore(3)...don't use this entry to send traps to at this time" ::= { s5AgTrpRcvrEntry 2 } s5AgTrpRcvrAddrType OBJECT-TYPE SYNTAX INTEGER { ip(1), ipx(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of address that is stored in the object s5AgTrpRcvrNetAddr. The value is: ip(1)....IP address ipx(2)...IPX address. Note: When changing the value of this object with an SNMP SET request, the SET PDU must also specify a value for the s5AgTrpRcvrNetAddr object." ::= { s5AgTrpRcvrEntry 3 } s5AgTrpRcvrNetAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The network address (in network order) for SNMP manager that is to receive the trap." ::= { s5AgTrpRcvrEntry 4 } s5AgTrpRcvrComm OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) ACCESS read-write STATUS mandatory DESCRIPTION "Community string to use." ::= { s5AgTrpRcvrEntry 5 } s5AgTrpRcvrAgeTime OBJECT-TYPE SYNTAX TimeIntervalSec ACCESS read-write STATUS mandatory DESCRIPTION "The time interval used to age entries out of the trap receiver table. The default value if not specified will be 0, or infinite, never to be aged out." DEFVAL { 0 } ::= { s5AgTrpRcvrEntry 6 } -- Last Remote Login Management s5AgRemoteLoginMgmt OBJECT IDENTIFIER ::= { s5AgentMgmt 5 } s5AgRemoteLoginIp OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "This value indicates the last IP address remote login to this system. " ::= { s5AgRemoteLoginMgmt 1 } s5AgRemoteLoginStatus OBJECT-TYPE SYNTAX INTEGER { statusUnknown (1), successful (2), passwordFail (3), loginTimeout (4), loginInactivityTimeout(5), telnetSessionExisted (6), nonAllowedIPaddr (7), localConsoleBusy (8), excessiveLoginFail (9), accessPermissionOff (10), loginLogout (11) } ACCESS read-only STATUS mandatory DESCRIPTION "This value indicates the status of remote login to this system. " ::= { s5AgRemoteLoginMgmt 2 } END