-- **************************************************************************** -- -- Integrity Server Trap SNMP MIB -- Management Information Base for SNMP Network Management -- -- -- Copyright 1993,2003-2004 Hewlett-Packard Development Company, L.P. -- -- Hewlett-Packard Company shall not be liable for technical or -- editorial errors or omissions contained herein. The information in -- this document is provided "as is" without warranty of any kind and -- is subject to change without notice. The warranties for HP products -- are set forth in the express limited warranty statements -- accompanying such products. Nothing herein should be construed as -- constituting an additional warranty. -- -- Confidential computer software. Valid license from HP required for -- possession, use or copying. Consistent with FAR 12.211 and 12.212, -- Commercial Computer Software, Computer Software Documentation, and -- Technical Data for Commercial Items are licensed to the U.S. -- Government under vendor's standard commercial license. -- -- The Hewlett-Packard Enterprise number is 11. -- The ASN.1 prefix to, and including the Hewlett-Packard Enterprise is: -- 1.3.6.1.4.1.11 -- -- **************************************************************************** -- -- -- * $Date: 11-24-2008$ -- * $Revision: 3.3$ -- -- IPF Trap MIB Revision -- ========================= -- -- MIB Rev of 1.0 is for ORCA time frame -- - This is the initial release of this MIB. -- 2.0 - Event Data Now taken from new E0 data base -- 2.1 - Add new Hondo events -- 2.2 - Add new events for support of Eiger, Oly -- 2.3 - Add new events for PFM, other new E0 events, and new 02 events -- 2.4 - Add new events for E0 events, and 3 new temperature 02 events -- 2.5 - Add new events for E0 events Rusa , ARc -- 2.6 - Add new events for E0 events COD, HPVM -- 2.7 - Add new events for E0 events RuSa-E, Merlion -- 2.8 - Add new events for E0 events Tahiti -- 2.9 - Add new events for E0 events Tahiti -- 3.0 - Add new events for E0 events to support Windows Server 2008 -- 3.1 - Add new events for E0 events to support Bora Bora -- 3.2 - Add new events for E0 events to support Bora Bora -- 3.3 - Add new events for E0 events to support Bora Bora -- -- **************************************************************************** HPIPF02TRAP-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises FROM RFC1155-SMI DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; hp OBJECT IDENTIFIER ::= { enterprises 11 } nm OBJECT IDENTIFIER ::= { hp 2 } hpnsa OBJECT IDENTIFIER ::= { nm 23 } hpIpfE0Events OBJECT IDENTIFIER ::= { hpnsa 35 } hpIpf02Events OBJECT IDENTIFIER ::= { hpnsa 45 } -- The following are objects defined for HP IPF Event Traps hpIpfEvtDetailStr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This string provides a detailed description of the Event along with variable information." ::= { hpIpf02Events 1 } -- Traps hpTempHighWarning752 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "One of the temperature sensors crossed its lower non-critical threshold." --#SUMMARY "Temperature sensor crossed lower non-critical threshold" --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 752 hpTempHighCritical753 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "One of the temperature sensors crossed its upper critical threshold." --#SUMMARY "A temperature inside the server went far outside the factory specified range" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 753 hpTempHighNonRecoverable754 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "One of the temperature sensors crossed its upper non-recoverable threshold." --#SUMMARY "Temperature sensor crossed upper non-recoverable threshold." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 754 hpTemperature4 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "One of the temperature sensors crossed its upper non-critical threshold." --#SUMMARY "A temperature inside the server has gone outside the factory specified range." --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 4 hpTemperature5 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "One of the temperature sensors crossed its upper critical threshold." --#SUMMARY "A temperature inside the server has gone far outside the factory specified range." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 5 hpTemperature6 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "One of the temperature sensors crossed its upper non-recoverable threshold." --#SUMMARY "Temperature sensor crossed upper non-recoverable threshold" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 6 hpTemperature755 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "A temperature inside the server has gone outside the factory specified range." --#SUMMARY "One of the temperature sensors crossed its upper non-critical threshold." --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 755 hpTemperature756 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "One of the temperature sensors crossed its upper critical threshold." --#SUMMARY "A temperature inside the server went far outside the factory specified range." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 756 hpEnvironment8 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "One of the voltage sensors crossed its lower critical threshold." --#SUMMARY "A measured voltage in the server has gone far outside the factory specified lower voltage range." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 8 hpEnvironment9 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "One of the voltage sensors crossed its lower non-recoverable threshold." --#SUMMARY "Voltage sensor crossed lower non-recoverable threshold" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 9 hpEnvironment10 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "One of the voltage sensors crossed its upper non-critical threshold." --#SUMMARY "A measured voltage in the server has gone outside the factory specified upper voltage range." --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 10 hpEnvironment12 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "One of the voltage sensors crossed its upper non-recoverable threshold - Check all boards with this voltage" --#SUMMARY "Voltage sensor crossed upper non-recoverable threshold" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 12 hpEnvironment704 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "Voltage fault - Check all boards with this voltage" --#SUMMARY "Voltage insufficient" --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 704 hpEnvironment728 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "Voltage degraded to critical level from less severe - Check all boards with this voltage" --#SUMMARY "Voltage reached critical level" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 728 hpEnvironment705 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "Voltage degraded to non-recoverable level from less severe - Check all boards with this voltage" --#SUMMARY "Voltage reached critical level" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 705 hpEnvironment706 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "Voltage becomes non-recoverable from either critical level or less severe level - Check all boards with this voltage" --#SUMMARY "Power Pod Voltage Fault" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 706 hpEnvironment707 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "Voltage absent" --#SUMMARY "Voltage absent" --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 707 hpFan710 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "Fan speed lags" --#SUMMARY "Fan speed lags" --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 710 hpChassis26 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "The chassis has been opened." --#SUMMARY "The server's built-in sensors have detected an open chassis door." --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 26 hpBmcFirmware730 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "The BMC firmware did not detect the system firmware boot." --#SUMMARY "The BMC firmware did not detect the system firmware boot" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 730 hpRedundantPower720 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "Power supply failed or disconnected" --#SUMMARY "Power supply failure" --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 720 hpRedundantPower732 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "The Power supply's sensors detect possible problems" --#SUMMARY "The power supply sensors detect a possible problem" --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 732 hpRedundantPower722 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "Power supply AC lost" --#SUMMARY "Power supply AC lost" --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 722 hpRedundantPower757 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "The Power Supply AC voltage was lost or is out of range." --#SUMMARY "The AC voltage to the power supply was lost or is out of range." --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 757 hpRedundantPower758 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "The AC voltage connected to the power supply is out of range." --#SUMMARY "The power supply AC voltage is out of range." --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 758 hpPowerSupply731 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "A/C Failed, disconnected, or out of range" --#SUMMARY "A/C Power failed, disconnected, or out of range" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 731 hpPowerSupply726 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "A/C Failed, disconnected, or out of range" --#SUMMARY "Power failure in power supply" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 726 hpSystemHW733 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "Cooling unit warning" --#SUMMARY "Cooling unit warning" --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 733 hpSystemHW734 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "Cooling unit failure" --#SUMMARY "Cooling unit failure" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 734 hpECCMemory518 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "Uncorrectable multi-bit ECC error has occurred in memory module" --#SUMMARY "Uncorrectable multi-bit ECC error has occurred" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 518 hpSystemFW700 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "System firmware error" --#SUMMARY "Generic trap for Critical or Fatal type E0 event from system firmware" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 700 hpSystemHW744 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "System event log almost full" --#SUMMARY "System event log almost full" --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 744 hpSystemHW735 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "BMC entering special mode" --#SUMMARY "BMC entering special mode" --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 735 hpSystemHW729 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "System shut-down or reset caused by sensor reading. " --#SUMMARY "System shut-down or reset caused by sensor reading" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 729 hpSystemHW745 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "TOC interrupt (crash dump)" --#SUMMARY "TOC interrupt (crash dump)" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 745 hpSystemHW746 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "INIT Initiated" --#SUMMARY "INIT Initiated" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 746 hpSystemHW751 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "PCI parity error detected" --#SUMMARY "PCI parity error detected" --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 751 hpSystemHW747 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "PCI system error detected" --#SUMMARY "PCI system error detected" --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 747 hpSystemFW699 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "Machine Check Initiated" --#SUMMARY "Machine Check Initiated" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 699 hpSystemHW113 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "A SCSI cable has been removed from the hot swap cage." --#SUMMARY "Hot Swap Cage: SCSI cable removed" --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 113 hpSystemHW748 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "OS run-time critical shutdown" --#SUMMARY "OS run-time critical shutdown" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 748 hpSystemHW749 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "ACPI state S5 (soft-off, entered by override)" --#SUMMARY "ACPI state S5 (soft-off, entered by override)" --#ARGUMENTS {} --#SEVERITY WARNING --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 749 hpSystemHW736 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "Watchdog timer expired - hard reset" --#SUMMARY "Watchdog timer expired - hard reset" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 736 hpSystemHW737 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "Watchdog timer expired - power-off" --#SUMMARY "Watchdog timer expired - power-off" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 737 hpSystemHW738 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "Watchdog timer expired - power-cycle" --#SUMMARY "Watchdog timer expired - power-cycle" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 738 hpSystemHW739 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "Missing FRU device" --#SUMMARY "Missing FRU device" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 739 hpSystemHW740 TRAP-TYPE ENTERPRISE hpIpf02Events VARIABLES { hpIpfEvtDetailStr } DESCRIPTION "Missing Entity" --#SUMMARY "Missing Entity" --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 100 --#STATE OPERATIONAL ::= 740 END