#-MIBFILE: cpqups.mib CPQUPS-MIB DEFINITIONS ::= BEGIN compaq OBJECT IDENTIFIER ::= { enterprises 232 } DisplayString ::= OCTET STRING PhysAddress ::= OCTET STRING DisplayString ::= OCTET STRING PhysAddress ::= OCTET STRING mib-2 OBJECT IDENTIFIER ::= { mgmt 1 } system OBJECT IDENTIFIER ::= { mib-2 1 } sysName OBJECT IDENTIFIER ::= { system 5 } compaq OBJECT IDENTIFIER ::= { enterprises 232 } cpqHostOs OBJECT IDENTIFIER ::= { compaq 11 } cpqHoComponent OBJECT IDENTIFIER ::= { cpqHostOs 2 } cpqHoTrapInfo OBJECT IDENTIFIER ::= { cpqHoComponent 11 } cpqHoTrapFlags OBJECT IDENTIFIER ::= { cpqHoTrapInfo 1 } cpqUps OBJECT IDENTIFIER ::= { compaq 12 } cpqUpsMibRev OBJECT IDENTIFIER ::= { cpqUps 1 } cpqUpsComponent OBJECT IDENTIFIER ::= { cpqUps 2 } cpqUpsInterface OBJECT IDENTIFIER ::= { cpqUpsComponent 1 } cpqUpsBasic OBJECT IDENTIFIER ::= { cpqUpsComponent 2 } cpqUpsFamily OBJECT IDENTIFIER ::= { cpqUpsComponent 3 } cpqUpsOsCommon OBJECT IDENTIFIER ::= { cpqUpsInterface 4 } cpqUpsMibRevMajor OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The Major Revision level of the MIB. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the supported information, correct interpretation of data may require a MIB document with the same major revision level." ::= { cpqUpsMibRev 1 } cpqUpsMibRevMinor OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The Minor Revision level of the MIB. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred." ::= { cpqUpsMibRev 2 } cpqUpsMibCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The overall condition. This object represents the overall status of the UPS system represented by this MIB." ::= { cpqUpsMibRev 3 } cpqUpsOsCommonPollFreq OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The Insight Agent's polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero (0) indicates that the Insight Agent retrieves the information upon request of a management station, it does not poll the device driver at a specific interval. If the poll frequency is zero (0) all attempts to write to this object will fail. If the poll frequency is non-zero, setting this value will change the polling frequency of the Insight Agent. Setting the poll frequency to zero (0) will always fail, an agent may also choose to fail any request to change the poll frequency to a value that would severely impact system performance." ::= { cpqUpsOsCommon 1 } cpqUpsOsCommonModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqUpsOsCommonModuleEntry ACCESS read-only STATUS mandatory DESCRIPTION "A table of software modules/ that provide an interface to the device this MIB describes." ::= { cpqUpsOsCommon 2 } cpqUpsOsCommonModuleEntry OBJECT-TYPE SYNTAX CpqUpsOsCommonModuleEntry ACCESS read-only STATUS mandatory DESCRIPTION "A description of a software module that provides an interface to the device this MIB describes." INDEX { cpqUpsOsCommonModuleIndex } ::= { cpqUpsOsCommonModuleTable 1 } cpqUpsOsCommonModuleEntry ::= SEQUENCE { cpqUpsOsCommonModuleIndex INTEGER, cpqUpsOsCommonModuleName DisplayString, cpqUpsOsCommonModuleVersion DisplayString, cpqUpsOsCommonModuleDate OCTET STRING, cpqUpsOsCommonModulePurpose DisplayString } cpqUpsOsCommonModuleIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "A unique index for this module description." ::= { cpqUpsOsCommonModuleEntry 1 } cpqUpsOsCommonModuleName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The module name." ::= { cpqUpsOsCommonModuleEntry 2 } cpqUpsOsCommonModuleVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..5)) ACCESS read-only STATUS mandatory DESCRIPTION "The module version in XX.YY format. Where XX is the major version number and YY is the minor version number. This field will be a null (size 0) string if the agent cannot provide the module version." ::= { cpqUpsOsCommonModuleEntry 3 } cpqUpsOsCommonModuleDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE(7)) ACCESS read-only STATUS mandatory DESCRIPTION "The module date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the module date. The hour, minute, and second field will be set to zero (0) if they are not relevant. The year field is set with the most significant octet first." ::= { cpqUpsOsCommonModuleEntry 4 } cpqUpsOsCommonModulePurpose OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The purpose of the module described in this entry." ::= { cpqUpsOsCommonModuleEntry 5 } cpqUpsLineStatus OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the AC line input to the UPS." ::= { cpqUpsBasic 1 } cpqUpsName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..20)) ACCESS read-only STATUS mandatory DESCRIPTION "The UPS name (type)." ::= { cpqUpsBasic 2 } cpqUpsEstimatedBatteryLife OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The estimated time, in minutes, of battery power available. The value will be negative one (-1) if the agent is unable to determine this information. A UPS may not provide this information when AC power is available." ::= { cpqUpsBasic 3 } cpqUpsAutoShutdownDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of minutes of battery power remaining before the UPS driver will begin a graceful shutdown of the OS. A value of -1 indicates that no automatic shutdown will occur." ::= { cpqUpsBasic 4 } cpqUpsLaunchCommand OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..250)) ACCESS read-only STATUS mandatory DESCRIPTION "Application to launch for UPS support." ::= { cpqUpsBasic 5 } cpqUpsAlarm OBJECT-TYPE SYNTAX DisplayString (SIZE(0..250)) ACCESS read-only STATUS mandatory DESCRIPTION "This variable contains the UPS alarm text." ::= { cpqUpsBasic 6 } cpqUpsMemberTable OBJECT-TYPE SYNTAX SEQUENCE OF CpqUpsMemberEntry ACCESS read-only STATUS mandatory DESCRIPTION "A table of entries that describes the family of rack-mounted servers that a single UPS supports." ::= { cpqUpsFamily 1 } cpqUpsMemberEntry OBJECT-TYPE SYNTAX CpqUpsMemberEntry ACCESS read-only STATUS mandatory DESCRIPTION "A table of entries that describes the family of rack-mounted servers that a single UPS supports." INDEX { cpqUpsMemberIndex } ::= { cpqUpsMemberTable 1 } cpqUpsMemberEntry ::= SEQUENCE { cpqUpsMemberIndex INTEGER, cpqUpsMemberName DisplayString, cpqUpsMemberCommunityStr DisplayString } cpqUpsMemberIndex OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "A unique index for this module description." ::= { cpqUpsMemberEntry 1 } cpqUpsMemberName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The name or address of one of the individual servers that is served by the rack-mounted UPS. Set cpqUpsMemberName to 0 to delete this row." ::= { cpqUpsMemberEntry 2 } cpqUpsMemberCommunityStr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The Community string for this individual server." ::= { cpqUpsMemberEntry 3 } cpqUpsAddMemberName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "To add a row to the cpqUpsMemberTable, this variable must be set, followed immediately by the set of the cpqUpsAddMemberCommunityStr. Sets must occur in this order, or else a new row will not be added to the table. " ::= { cpqUpsFamily 2 } cpqUpsAddMemberCommunityStr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "To add a row to the cpqUpsMemberTable, the cpqUpsAddMemberName must be set, followed immediately by a set of this variable. Sets must occur in this order, or else a new row will not be added to the cpqUpsMemberTable." ::= { cpqUpsFamily 3 } cpqUpsLineFailed TRAP-TYPE ENTERPRISE compaq VARIABLES { cpqUpsEstimatedBatteryLife } --#SUMMARY "UPS has about %d minutes of power left." --#ARGUMENTS {0} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#MSG_FORMATTER "$V1V#UPS Battery Time (Min): #" --#TYPE "UPS A/C Line Failed (Ver. 1)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "AC Line power failure. The UPS reports that the AC line power has failed." ::= 12001 cpqUpsLineOk TRAP-TYPE ENTERPRISE compaq --#SUMMARY "UPS reports AC line power has returned." --#ARGUMENTS {} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL --#TYPE "UPS A/C Line OK (Ver. 1)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "AC line power ok. The UPS reports that the AC line power has returned." ::= 12002 cpqUpsShutdown TRAP-TYPE ENTERPRISE compaq --#SUMMARY "The UPS has initiated server shutdown." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE NONOPERATIONAL --#TYPE "UPS Shutdown In Progress (Ver. 1)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "UPS initiating graceful server shutdown. The UPS software is initiating a graceful server shutdown. Every attempt to preserve the state of the file system will be made. The server shutdown will be initiated due to a power anomaly." ::= 12003 cpqUpsConfirmation TRAP-TYPE ENTERPRISE compaq --#SUMMARY "Server now operational after UPS shutdown." --#ARGUMENTS {} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL --#TYPE "UPS Recovery Complete (Ver. 1)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "Server now operational after power down. This server has previously been shutdown due to a power anomaly and has just become operational again." ::= 12004 cpqUpsBatteryLow TRAP-TYPE ENTERPRISE compaq --#TYPE "UPS Battery Low" --#SUMMARY "Server will soon lose power." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#TYPE "UPS Battery Low (Ver. 1)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "UPS Battery Low. The server will soon lose power." ::= 12005 cpqUps2LineFailed TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqUpsEstimatedBatteryLife } --#SUMMARY "UPS has about %d minutes of power left." --#ARGUMENTS {2} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#MSG_FORMATTER "$V3V#UPS Battery Time (Min): #" --#TYPE "UPS A/C Line Failed (Ver. 2)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "AC Line power failure. The UPS reports that the AC line power has failed." ::= 12006 cpqUps2LineOk TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } --#TYPE "AC Line Power OK" --#SUMMARY "UPS reports AC line power has returned." --#ARGUMENTS {} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL --#TYPE "UPS A/C Line OK (Ver. 2)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "AC line power ok. The UPS reports that the AC line power has returned." ::= 12007 cpqUps2Shutdown TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } --#SUMMARY "The UPS has initiated server shutdown." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE NONOPERATIONAL --#TYPE "UPS Shutdown In Progress (Ver. 2)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "UPS initiating graceful server shutdown. The UPS software is initiating a graceful server shutdown. Every attempt to preserve the state of the file system will be made. The server shutdown will be initiated due to a power anomaly." ::= 12008 cpqUps2Confirmation TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } --#SUMMARY "Server now operational after UPS shutdown." --#ARGUMENTS {} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL --#TYPE "UPS Recovery Complete (Ver. 2)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "Server now operational after power down. This server has previously been shutdown due to a power anomaly and has just become operational again." ::= 12009 cpqUps2BatteryLow TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } --#SUMMARY "Server will soon lose power." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#TYPE "UPS Battery Low (Ver. 2)" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "UPS Battery Low. The server will soon lose power." ::= 12010 cpqUpsOverload TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } --#TYPE "UPS Overload" --#SUMMARY "The UPS has been overloaded." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "The UPS has entered an overload condition. A failure may occur unless the overload is corrected." ::= 12011 cpqUpsPendingBatteryFailure TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags } --#TYPE "UPS Pending Battery Failure" --#SUMMARY "The UPS battery is about to fail." --#ARGUMENTS {} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "The UPS battery is about to fail. Replace as soon as possible." ::= 12012 cpqUpsGenericCritical TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqUpsAlarm } --#TYPE "UPS Critical Alarm" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY CRITICAL --#TIMEINDEX 99 --#STATE DEGRADED --#MSG_FORMATTER "$V3V#Alarm: #" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "Generic UPS critical alarm." ::= 12013 cpqUpsGenericInfo TRAP-TYPE ENTERPRISE compaq VARIABLES { sysName, cpqHoTrapFlags, cpqUpsAlarm } --#TYPE "UPS Info Alarm" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL --#MSG_FORMATTER "$V3V#Alarm: #" --#ENABLE true --#CATEGORY "Proliant UPS Events" DESCRIPTION "Generic UPS informational alarm." ::= 12014 END