-- ************************************************************************** -- ************************************************************************** -- -- File : mmalert.mib -- Description : IBM Management Module traps -- MIB for traps(Alerts) -- By : Joe Bolan, IBM -- Version : 1.2 -- Date : December 20, 2002 -- -- -- Copyright (c) 2002/2003 IBM All Rights Reserved. -- -- -- Contains trap descriptions for: -- (1) Bladecenter Management Module -- -- -- Changes History -- -- Date Reason -- **** ****** -- 4/08/02 Lorrie - Created -- 12/20/02 jeb - Fix priority to include recovery, move SFF to critical, text on KVM/CD -- 05/17/04 BN - Add two new alerts (blade throttle and power management) -- 05/19/05 KS - Moved blade throttle and power management to system level alerts. -- -- -- This MIB is used by the Management Module to describe -- traps for alert conditions detected by the MM/Blades on Bladecenter hardware. -- ************************************************************************** -- ************************************************************************** BLADESPPALT-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 enterprises FROM RFC1155-SMI DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215; ibm OBJECT IDENTIFIER ::= { enterprises 2 } -- IBM products group ibmProd OBJECT IDENTIFIER ::= { ibm 6 } -- IBM Netfinity SP supportProcessor OBJECT IDENTIFIER ::= { ibmProd 158 } -- IBM Netfinity SP Alert mmRemoteSupTrapMIB OBJECT IDENTIFIER ::= { supportProcessor 3 } -- ************************************************************************** -- Start: Management Module Adapter SP Alerts -- ************************************************************************** -- the rsspalt generic trap generator group remoteSupTrapMibObjects OBJECT IDENTIFIER ::= { mmRemoteSupTrapMIB 1 } spTrapInfo OBJECT IDENTIFIER ::= { remoteSupTrapMibObjects 1 } spTrapDateTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Timestamp of Local Date and Time when alert was generated" ::= { spTrapInfo 1 } spTrapAppId OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Application ID, always 'BladeCenter Management Module'" ::= { spTrapInfo 2 } spTrapSpTxtId OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "SP System Identification - Text Identification" ::= { spTrapInfo 3 } spTrapSysUuid OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Host System UUID(Universal Unique ID)" ::= { spTrapInfo 4 } spTrapSysSern OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Host System Serial Number" ::= { spTrapInfo 5 } spTrapAppType OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Application Alert Type - Event Number ID" ::= { spTrapInfo 6 } spTrapPriority OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Alert Severity Value - Critical Alert(0) - Non-Critical Alert(2) - System Alert(4) - Recovery Alert(8) - Informational Only Alert(255)" ::= { spTrapInfo 7 } spTrapMsgText OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Alert Message Text" ::= { spTrapInfo 8 } spTrapHostContact OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Host Contact" ::= { spTrapInfo 9 } spTrapHostLocation OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Host Location" ::= { spTrapInfo 10 } spTrapBladeName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Blade Name" ::= { spTrapInfo 11 } spTrapBladeSern OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Blade Serial Number" ::= { spTrapInfo 12 } spTrapBladeUuid OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Blade UUID(Universal Unique ID)" ::= { spTrapInfo 13 } -- ************************************************************************** -- Critical Traps -- ************************************************************************** -- 4.2.1.1 mmTrapTempC TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "Critical Alert: Temperature threshold exceeded." ::= 0 -- 4.2.1.2 mmTrapVoltC TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "Critical Alert: Voltage threshold exceeded." ::= 1 -- 4.2.1.3 -- is this not supported on blades? mmTrapTampC TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "Critical Alert: Physical intrusion of system has occurred." ::= 2 -- 4.2.1.4 mmTrapMffC TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "Critical Alert: Multiple fan failure." ::= 3 -- 4.2.1.5 mmTrapPsC TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "Critical Alert: Power supply failure." ::= 4 -- 4.2.1.6 mTrapHdC TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "Critical Alert: Hard disk drive failure." ::= 5 -- 4.2.1.7 mmTrapVrmC TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "Critical Alert: Voltage Regulator Module(VRM) failure." ::= 6 -- 4.2.2.2 mmTrapSffC TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "Critical Alert: Single Fan failure." ::= 11 -- 4.2.1.8 mmTrapMsC TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "Critical Alert: Multiple switch module failure." ::= 31 -- 4.2.1.9 mmTrapIhcC TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "Critical Alert: Incompatible hardware configuration." ::= 36 -- ************************************************************************** -- Non-Critical Traps -- ************************************************************************** -- 4.2.2.1 mmTrapRdpsN TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "Non-Critical Alert: Redundant Power Supply failure." ::= 10 -- 4.2.2.3 mmTrapTempN TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "Non-Critical Alert: Temperature threshold exceeded." ::= 12 -- 4.2.2.4 mmTrapVoltN TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "Non-Critical Alert: Voltage threshold exceeded." ::= 13 -- 4.2.2.6 mmTrapRmN TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "Non-Critical Alert: Redundant module." ::= 32 -- ************************************************************************** -- System Traps -- ************************************************************************** -- 5.2.14 mmTrapSecDvS TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "System Alert: Secondary Device warning." ::= 15 -- 4.2.3.1 mmTrapPostToS TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "System Alert: Post Timeout value exceeded." ::= 20 -- 4.2.3.2 mmTrapOsToS TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "System Alert: OS Timeout value exceeded." ::= 21 -- 4.2.3.3 mmTrapAppS TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "System Alert: Application Alert." ::= 22 -- 4.2.3.4 mmTrapPoffS TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "System Alert: Power Off." ::= 23 -- 4.2.3.5 mmTrapPonS TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "System Alert: Power On." ::= 24 -- 4.2.3.6 mmTrapBootS TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "System Alert: System Boot Failure." ::= 25 -- 4.2.3.7 mmTrapLdrToS TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "System Alert: OS Loader Timeout." ::= 26 -- 4.2.3.8 mmTrapPFAS TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "System Alert: Predictive Failure Analysis(PFA) information." ::= 27 -- 4.2.3.9 mmTrapKVMSwitchS TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "System Alert: Keyboard/Video/Mouse(KVM) or Medial Tray(MT) switching failure." ::= 33 -- 4.2.3.10 mmTrapSysInvS TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "System Alert: Inventory." ::= 34 -- 4.2.3.11 mmTrapSysLogS TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "System Alert: System Log 75% full." ::= 35 -- 4.2.3.12 mmTrapNwChangeS TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "System Alert: Network change notification." ::= 37 -- 4.2.3.13 mmTrapBlThrS TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "System Alert: Blade Throttle" ::= 39 -- 4.2.3.14 mmTrapPwrMgntS TRAP-TYPE ENTERPRISE mmRemoteSupTrapMIB VARIABLES { spTrapDateTime, spTrapAppId, spTrapSpTxtId, spTrapSysUuid, spTrapSysSern, spTrapAppType, spTrapPriority, spTrapMsgText, spTrapHostContact, spTrapHostLocation, spTrapBladeName, spTrapBladeSern, spTrapBladeUuid } DESCRIPTION "System Alert: Power Management" ::= 40 END